Loading...
Pre-Application - 1997 CITY OF CAMPBELL Mr. Tim Juif Proj ect Manager SEMCO 1217 South 7th Street Modesto, CA 95351 Community Development Department. Current PlanningApri130, 1997 RE: Pre-application (P A 97-23) for proposed above ground tank installation 720 Camden Avenue-Economy Lumber Dear Mr. Juif: The City of Campbell Planning Division has reviewed your Pre-application (P A 97-23) for the installation of an above ground fuel tank to be located at 720 Camden Avenue and is supportive of conditionally approving your plans subject to the following conditions: Planning Division: 1. The proposed above ground tank shall be 11 feet 3 inches in length, 8 feet in width and 5 feet 6 inches in height and shall be located as specified by the site plan submitted by the. applicant on April 3, 1997. The tank shall have an aggregate look with a natural stone color. 2. Screening slats shall be installed prior to installation of the tank in a portion of the existing chain link fence located south of the proposed location for the above ground fuel tank as indicated on the enclosed site plan. The slats shall be made of non-combustible material an? shall be painted to match the color of slats currently found at the subject site. Building Division: 1. Applicant shall comply with all Building Code requirements and obtain necessary pennits as detennined by the Building Division. 2. All electrical installations shall confonn to NEC Section 514 for electrical supply to the gasoline dispensers. Public Works Department: 1. Applicant shall insure that the proposed above ground fuel tank does not conflict with any existing easements. Central Fire District: 1. Prior to perfonning any grading, demolition, construction or building modifications, the applicant shall make an application to, and obtain from the Building and Fire Departments all necessary pennits. The requirements for conditions if stated above shall be incorporated into the project drawings submitted for the Building and Fire Department Pennits. 70 North First Street. Campbell, California 95008.1423 . TEL 408.866.2140 . FAX 408.866.8381 . TOO 408.866.2790 11 Page 2 PA 97-23-720 Camden Avenue 2. Applicant shall comply with all Fire Department requirements as stated in the attached Plan Review Comment sheet dated 4/25/97 prepared by Richard Baker. Should you have any questions regarding the above referenced matter or need additional infonnation, please do not hesitate to contact me at the Community Development Department at (408) 866-2142. Sincerely, t2/â . ~~ Aki R. Irani Planner I enclosure cc: S & W Lumber Company, Property Owner Frank Cauthorn, Building Official Harold Housley, Land Development Engineer Richard Baker, Central Fire District Tim Haley, Associate Planner File 11 FIRe DEPARTMENT SANTA CLARA COUNTY CONTROL NUMBER 14700 Winchester Blvd., Los Gatos, CA 95030-18 ~§ILDING PERMIT NUMBER (408) 378-4010 (phone) . (408) 378-9342 (fax) PLAN REVIEW NUMBER 9 7 - 0 8 4 5 PLAN REVIEW COMMENTS NO. REQUIREMENT CODE/SEC. SHEET CFC 105.3 CFC 7902.2.2. 1 I I CFC J 7902.1.1 .8.1 I i I I CFC Apdx lIF 4.4.2 CFC Apdx lIF 5.5 CBL DISTRICT PLANS SECJFLOOR NAME OF PROJECT This installation shall comply with the following: 1. 1995 California Fire Code (CFC), as adopted by the City of Campbell, 2. Chapter 17.06 of the Campbell Municipal Code (CMC) 1 Obtain approval from City of Campbell Building Department (for electrical permit) and the City of Campbell Planning Department for this installation. 2 The storage of flammable/ combustible liquids in aboveground tanks outside of buildings is permitted only in areas zoned as "Industrial" or as approved by the Chief. Additionally tank locations relative to buildings and property lines shall be approved by the Chief. Note: Tank installation has been approved by the Fire Marshal. Tank location has been approved by the Fire Marshal. 3 Normal vent shall be at least as large as the fill or withdrawal connection, whichever is larger, but not less than (1.25) inch nominal inside diameter. 4 Approved flame arresters shall be installed in normal vents. 0 5 The tanks shall not be filled in excess of (90) percent of their capacity. An overfill prevention system shall be provided. The system shall: 1. notify the filling person that the tank is (85) percent full by providing an audible or visual alarm, or other approved means, and 2. automatically shut off the flow of fuel to the tank at (90) percent capacity. A sign shall be provided at the fill point which describes the filling procedure and provides a tank calibration chart. The filling procedure shall require the person filling the tank to determine the gallonage required to fill the tank ~cs;w ~L ~ OCCUPANCY I CaNST. TYPE PERMITTEE Semco 0:/25/97 PA~E OF~ I AREA I LOAD I DESCRIPTION AG HazMat Installation I BY Baker, Richard ECONOMY LUMBER I LOCATION 720 Camden A v A California Fire Protection District serving Santa Clara County and the communities of Campbell. Cupertino. Los Altos. Los Altos Hills. Los Gatos. Monte Sereno. Morgan Hill. and Saratoga 11 CODE/SEC. SHEET CFC 5201.8 ~~dx 5.5 CFC 5201.5.3 CFC 5201.5.3 CFC I 5201.6.3 CFC I 7902.1.10 .4 CFC 7902.2.7. 2 CONTROL NUMBER BUILDING PERMIT NUMBER PLAN REVIEW NUMBER 97- 0845 PLAN REVIEW COMMENTS NO. I REQUIREMENT to (90) percent before commencing the fill operation. 6 Signs prohibiting dispensing into unapproved containers and requiring vehicle engines to be stopped during fueling shall be conspicuously posted within sight of each dispenser. Conspicuous signs prohibiting simultaneous tank filling and fuel dispensing shall be posted. 7 A portable fire extinguisher (minimum 2A:20B:C) shall be provided and located such that it is not more than (75) feet from any pump, dispenser, or fill pipe openIng. S IEmergency shut down device for fuel dispenser shall be located within (75) feet of, but not less than (25) feet from dispensers. Such device shall be labeled "EMERGENCY FUEL SHUTDOWN DEVICE". 9 A sign shall be posted in a conspicuous location stating: IN CASE OF FIRE OR SPILL 1. Use emergency pump shutoff! 2. Report the accident! Fire Department No. 911 Facility Address: 720 Camden Ave. Campbell, CA 10 Vent pipe outlets for tanks shall be located such that vapors are released at a safe point outside of buildings and not less than (12) feet above the adjacent ground level. 11 Metallic fill pipes shall be designed and installed to minimize the generation of static electricity by terminating the pipe within (6) inches of the bottom of the tank and shall be installed to prevent excessive vibration. ~L ~ I OCCUPANCY CONST. TYPE I LOAD DESCRIPTION DATE PAGE DISTRICT PLANS SPECS NEW PERMITTEE Semco 04/25/97 ~OF~ CBL 0 0 0 SECJFLOOR I AREA NAME OF PROJECT BY AG HazMat Installation Baker, Richard LOCATION ECONOMY LUMBER 720 Camden Av n CODE/SEC. SHEET CFC 5201.5.4 CFC 5201.10 CFC 5202.3.9 I CMC I 17.06.400 ! ! I i I CFC I 8001.9.3 I I I I I CONTROL NUMBER BUILDING PERMIT NUMBER PLAN REVIEW NUMBER 9 7 - 0 8 4 5 PLAN REVIEW COMMENTS NO. REQUIREMENT 12 An electrical disconnect switch shall be provided for all dispensers in accordance with the Electrical Code. The disconnect shall be placed in the OFF position before repairing dispensers and before closing a motor vehicle fuel-dispensing station. 13 Weeds, grass, brush, trash and other combustibles shall be kept not less than (10) feet from fuel storage vessels and fuel handling equipment. 14 Accurate daily inventory records shall be maintained and reconciled for each tank for indication of possible leakage from the tanks. The records shall be kept on site and available for review upon request and shall include records showing, for each product, daily reconciliation between each product on hand and the amount of product dispensed. A consistent or or accidental loss of product shall be immediately reported to the fire department. 15 The Hazardous Materials Management Plan shall be updated. The hazardous materials inventory statement, storage map, and separation, containment, and monitoring page shall be updated to include the above ground tank. A Hazardous Materials Management Plan is enclosed. 16 ¡Guard posts shall be constructed of steel not less than (4) inches thick and concrete filled, spaced not more than (4) feet between post on center, set not less than (3) feet deep in a concrete footing of not less than (15) inch diameter, set with the top of the posts not less than (3) feet above ground, and located not less than (3) feet from the tank. Note: The height of the guard post shall be no higher than the distance between the guard post and the tank. The ,(3) foot clearance from tank has been approved by the Fire Marshal per code Ivariance request. I ! : ¡TeSting and Inspection: DISTRICT PLANS SPECS NEW RMDL AS OCCUPANCY CONST. TYPE PERMITTEE I DATE PAGE 04/25/97 ~ OF ~ BY CBL 0 0 0 0 0 SECJFLOOR I AREA LOAD NAME OF PROJECT Semco I DESCRIPTION Baker, Richard AG HazMat Installation ECONOMY LUMBER I LOCATION 720 Camden A v 'n CONTROL NUMBER BUILDING PERMIT NUMBER PLAN REVIEW NUMBER 97- 0845 PLAN REVIEW COMMENTS CODE/SEC. SHEET NO. REQUIREMENT CFC 7902.1.8. 2.5 17 The tank shall pass a pneumatic or hydrostatic pressure test of 5 psig for 30 minutes, with soap testing, to verify tank integrity. Please prepare for and call to arrange for an inspection to perform this test. CFC 7902.1.8. 2.5 18 The secondary containment shall pass a 3 psig pneumatic pressure test for 30 minutes, with soap testing, or a 24-hour standing water test. Please prepare for and call to arrange for an inspection to perform this test. CMC 17.06.09~ 17.06.351 CMC I 17.06.09g 17.06.350 19 Overfill device shall be demonstrated during inspection. Please prepare and arrange for this testing to be conducted during the inspection. 20 Secondary con tainmen t monitoring methods- and / or device shall be demonstra ted during inspection. Please prepare and arrange for this testing to be conducted during the inspection. CFC 105.4 21 A final inspection, which will include a review of the remaining plan review items, is required for sign-off by Hazmat. APPROVED subject to conditions noted above. I I Please call to schedule inspections at least 48 hours in advance. CFC 105.4 No hazardous materials are allowed in tanks until written approval is obtained from HAZ MAT. CFC I 105.2.3 The applicant and applicant's agents shall carry out the proposed activity in compliance with all laws and regulations applicable thereto, whether specified or not, and in complete accordance with approved plans and specifications. DISTRICT PLANS SPECS NEW RMDL AS I OCCUPANCY CONST. TYPE PERMmEE CBL D D D D D SECJFLOOR I AREA LOAD Semco I DATE PAGE 04/25/97 ~OF~ I BY Baker, Richard DESCRIPTION AG HazMat Installation NAME OF PROJECT ECONOMY LUMBER I ~O;;TION Camden A v II CODE/SEC. SHEET CFC 103.3.2.1 CBL DISTRICT PLANS SPECS NEW 0 SECJFLOOR NAME OF PROJECT 0 CONTROL NUMBER BUILDING PERMIT NUMBER PLAN REVIEW NUMBER 97- 0845 PLAN REVIEW COMMENTS NO. REQUIREMENT This approval shall not be construed to be an approval of a violation of the provisions of the Uniform Fire Code or of other laws or regulations of the jurisdiction. Any inspections presuming to give authority to violate or waive provisions of such laws or regulations shall not be valid. 0 ~L ~ I OCCUPANCY CONST. TYPE , LOAD DESCRIPTION ìPERMrrTEE Semco I DATE I PAGE 04/25/97 ~OF~ BY AREA AG HazMat Installation Baker, Richard LOCATION 720 ECONOMY LUMBER Camden A v , tl FIR!:. 0 EP ARTMENT SANTA CLARA COUNTY CONTROL NUMBER 14700 Winchester Blvd., Los Gatos, CA 95030-1818 (408) 378-4010 (phone). (408) 378-9342 (fax) BUILDING PERMIT NUMBER PLAN REVIEW NUMBER 9 7 - 0 8 4 4 FILE NUMBER D EVELO PMENT REVIEW COMMENTS CODE/SEC. SHEET NO, REQUIREMENT Review of a Pre-application for a Use Permit Modification to allow the installation of an above ground fuel storage tank. 1. Prior to performing any grading, demolition, construction or building modifications, the applicant shall make an application to, and obtain from the Building and Fire Department all necessary permits. The requirements or conditions if stated above shall be incorporated into the project drawings submitted for Building and Fire Department Permits. 2. Hazardous Materials Compliance Review: Hazardous Materials Compliance review is not completed in the Development Review Process. Questions regarding Hazardous Materials may be directed to 408-378-4010x20. DISTRICT PLANS SPECS NEW RMDL AS OCCUPANCY CON ST. TYPE I PERMITTEE SEMCO DATE I PAGE 04/04/97 ~ OF ~ BY CBL D DDDD I AREA LOAD DESCRIPTION SEC.lFLOOR ECONOMY LUMBER Commercial Development ¡LOCATION 720 Camden A v Veargason, Chris NAME OF PROJECT A California Fire Protection District serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and Saratoga -" ,- --.... ,.., ..,.. ,..,-.-.-,-".."..,.,..-..,..,.-"......,........,...,,"....., ""'Tr .-].. ,..,-_....,..