Loading...
Pre-Application - 2000 Of'CA.'4 ...' ;t>~ ¡.. ~ ... t'" ~ l"'" - -:." .,' r; '-' RCH"'O' -----. .~...._-_._--_._~-_.~-- CITY OF CAMPBELL Community Development Department December 1, 2000 Ami Molaie 1311 Camden Avenue Campbell, CA 95008 Subject: PRE 2000-38(Revised) 1311 Camden Avenue Dear Mr. Molaie: Please frrst let me apologize for the delayed response to your revised submittal. The revised plan incorporates architectural features that are more consistent with other recent approvals for commercial building. However, the Planning Division still has significant concerns regarding the proposed remodel. The significant areas of concern are as follows; . The size of the building relative to the number of parking spaces or parking ratio of 1 :635 square feet of building area. Retail buildings provide a parking ratio of 1 :200 and the recent Carpeteria proposal had a parking ration of 1:355.A parking variation of this magnitude is not supported. The location of a service door facing the public right-of-way is not considered acceptable. It is recommended that an alternative location/orientation be pursued and The landscaping space between the parking area and the sidewalk is considered minimal. It is recommended that an 8' to 10' foot planting strip be provided to buffer the appearance of the parking area. . . Please contact me at (408) 866-2144 to schedule a meeting to discuss these comments and your proposal. ~~ Tim 1. Haley Associate Planner cc: ARCWEST 6768 Normandy, Newark,CA 94560 70 North First Street Campbell, California 95008,1423 TEL 408.866.2140 . FAX 408.866.8381 . TDO 408,866.2790 r' Of'CA.'4 ...' þ~ ¡.. ~ ... . r'" U .' l"'" ... ... -:. ... '" .' . '-' 'JRCH"'O' ..... -.-"".....-.---.- CITY OF CAMPBELL Community Development Department. Current Planning June 27, 2000 Chad Engstrom 6768 Normandy Drive Newark, CA 94560 Subject: PRE 2000-38 - 1311 Camden Avenue - Dear Mr. Engstrom: The Planning Division has reviewed your preliminary application to remodel an existing commercial building on the above referenced property. The subject property is located in a C-2-S (General Commercial) Zoning District. The proposed remodel will require approval of a site and architectural application that would be considered by the Planning Commission at a public hearing. The processing time for such an application is 45- 60 days. Planning Division Comments: 1. The application submittal is significantly incomplete. All four elevations of the building as well as a dimension site plan need to be submitted for a proper review. A site utilization in terms of building, landscaping and paving coverage has not been provided. 2. The functional placement of the retail area and the warehousing area seems awkward due to the shape of the lot. It is recommended that the warehousing portion be considered towards the westerly side of the property. 3. The proposed parking ratio of 1 :376 varies substantially from the standard of 1 :200 for general retail .uses. Your application will have to demonstrate adequacy of the proposed parking ratio and alleviate the planning commission's concern regarding the limited use of this commercial building in the future due to limited parking facilities. 4. The architectural style and materials need to be more clearly defined. 70 North First Street' Campbell, California 95008.1423 ' TEL 408,866,2140 . FAX 408,379,2572 . TOO 408.866,2790 ~..".......~_.".."." .. T' Mr. Chad Engstrom - 131: ...-àIIlden Avenue June 27,2000 Page 2 The plans were distributed to the City's Architectural Advisor, the Public Works Department, Redevelopment Agency, Building Division and the County Fire Department through the development review committee process. The following comments are offered: Architectural Advisor's Comments 1. Building Design: Found the design to be somewhat dated. 2. Materials/Color Board: The proposed exterior materials should be noted on the drawings and a materials/color board provided. Public Works Comments 1. Incomplete Plans: The application and plans are incomplete and not presented in the form to allow proper review. 2. Lack of Dimensions/Scale: The plan is devoid of dimensions and does not appear to be to the scale that is indicated on the drawing. For example, the frontage along Camden Avenue, according to the Assessor's map, is approximately 221 feet but it scales at 237 feet in these plans. 3. Excessive Number & Widths of Driveways: There are two proposed driveways. A concern is expressed regarding the width of the driveways as well as the number. Fire Department Comments Review of a proposed 4,242 square foot addition to an existing retail building. The new total floor area will become 6,407 square feet. 1. Site Access and Water Supply: Review of this development proposal is limited to acceptability of site access and water supply as they pertain to fire department operations and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work, the applicant shall make application to, and receive from, the Building Department, all applicable construction permits. 2.. Required Fire Flow: Required fire flow for this project is 2,250 GPM at 20 psi residual pressure. The required fire flow is available from area water mains and fire hydrant(s) which are spaced at the required spacing. 3. Automatic Fire Sprinkler System Required: Buildings requiring a fire flow in excess of 2,000 GPM, or in excess of two stories or 35 feet in height, shall be equipped throughout with an automatic fire sprinkler system, hydraulically designed per National Fire Protection Association (NFP A) Standard #13. *See additional underground fire service comment. 4. Underground Fire Service: A copy of the fire department "approved" underground fire service drawings shall be provided to the appropriate water company for record purposes, prior to installation. To prevent engineering delays, the underground contractor shall submit to the fire department, three sets of shop drawings designed per NFP A Std. 24, a completed pennit application and applicable fees for review and approval ASAP. --".~~.. .. T" . Mr. Chad Engstrom - 1311 _àIIlden Avenue June 27, 2000 Page 3 5. Conditions on Building Permit Plan Submittals: To prevent plan review and inspection delays, the above noted Development Review Comments shall be restated on all pending and forthcoming building permit submittals. Review of these plans does not release the Developer, Architect or Contractor of the responsibility for the corrections or mistakes, errors or omissions contained therein. Please do not hesitate to contact me at (408) 866-2144 to schedule a meeting to discuss these comments and the application process. Sincerely, ~~ Tim J. Haley Associate Planner cc: Sharon Fierro, Community Development Director Bill Bruckart, Building Official Harold Housley, Land Development Engineer Chris Veargason, County Fire Department .'.........-- ..-""...,. . ,.. 'T" FIRE D EP ARTMENT SANTA CLARA COUNTY CONTROL NUMBER 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 (phone) . (408) 378-9342 (fax) BLDG PERMIT NUMBER PLAN REVIEW NUMBER 00- 1 384 ALE NUMBER DEVELOPMENT REVIEW COMMENTS CODE/SEC, I SHEET I, REQUIREMENT Review of a proposed 4,242 square foot addition to an existing retail building. The new total floor area will become 6,407 square feet. UK Appendix III-A 1 Review of this Developmental proposal is limited to acceptability of site access and water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall make application to, and receive from, the Building Department all applicable construction permits. 2 Required Fire Flow: Required fire flow for this project is 2,250 GPM at 20 psi residual pressure. The required fire flow is available from area water mains and fire hydrant(s) which are spaced at the required spacing. UFC 1003,2.2 as amended by CMC 17.04.040 3 Automatic Fire Sprinkler System Required: Buildings requiring a fire flow in excess of 2,000 GPM, or in excess of two stories or 35 feet in height, shall be equipped throughout with an automatic fire sprinkler system, hydraulically designed per National Fire Protection Association (NFPA) Standard #13. * see additional additional underground fire service comment * 4 A copy of the fire department "approved" underground fire service drawings shall be provided to the appropriate water company for record purposes, prior to installation. To prevent engineering delays, the underground contractor shall submit to the fire department 3 sets of shop drawings designed per NFP A Std. 24, a completed permit application, and applicable fee's for review and approval ASAP. City PLANS SPECS NEW RMDL AS OCCUPANCY CON ST. TYPE PERMITTEE DATE PAGE CBL 0 0 0 0 0 ARCWEST 6/5/2000 ~OF~ SECJFLOOR I AREA LOAD DESCRIPTION BY Commercial Development Hokanson, Wayne NAME OF PROJECT LOCATION THE FLOOR CENTER RETAIL BUILDING 1311 Camden A v A California Fire Protection District serving Santa Clara County and the communities of Campbell, Cupertino. Los Altos, Los Altos Hills, Los Gatos, Monte Sereno. Morgan Hill. and Saratoga '--'-""--"""" .. .............~,............ .......-...,..."...... .. .._.~ FIRE 0 EP ARTMENT SANTA CLARA COUNTY CONTROL NUMBER 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 (phone) . (408) 378-9342 (fax) BLDG PERMIT NUMBER PLAN REVIEW NUMBER 00- 1 384 FILE NUMBER DEVELOPMENT REVIEW COMMENTS CODE/SEC, I SHEET 11 REQUIREMENT 5 To prevent plan review and inspection delays, the above noted Developmental Review Conditions shall be restated on all pending and forthcoming building permit submittals. Review of these plans does not release the Developer, Architect or Contractor of the responsibility for the corrections of mistakes, errors or omissions contained therein. City PLANS SPECS NEW RMDL AS OCCUPANCY CaNST. TYPE PERMITTEE DATE PAGE CBL 0 0 0 0 0 ARCWEST 6/5/2000 ~oF2 SEC./FLOOR I AREA LOAD DESCRIPTION BY Commercial Development Hokanson, Wayne NAME OF PROJECT LOCATION THE FLOOR CENTER RETAIL BUILDING 1311 CamdenAv A California Fire Protection District serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos. Monte Sereno, Morgan Hill. and Saratoga ~""'-'~'~'--'-"""'" ARCWEST 6768 Normandy Drive, Newark, California, 94560 Phone 510-790-2405 Re; Pre Application Review Application Description. May 24, 2000 Description of proposed project. The proposed project is a expansion of an existing carpet retail store located on 1311 Carndon Avenue, Campbell, California. The project is located in the County of Santa Clara in the City of Campbell with a zoneing of C2S - General Commercial District. 3 blocks off highway 17. The new retail store is to expand the current business as it exists, with expanded office space, warehouse, and store sales area. The square footages are listed on the project information sheet on the included site plan. There are planed an average of 1.5 employees during and average working days (Monday - Friday), and an average of 2 employees on Saturday. The typical store hours will be from 8:30 a.m. to 7:00 p.m. during the working week (Monday - Friday) and from 10:00 a.m. to 4:00 p.m. on Saturday. The store is planed to be closed on Sundays and holidays. The adjacent business includes a convalescent home to the rear, a fast food restaurant ljack-in-the-box) driveup and sit down restaurant to the side. Other business across the street include a number of restaurants, including a Wenches hotdog stand, a Foster Freeze hamburger stand, the Royal Taz, a sit down restaurant, and The Embassy Hotel. t' Of'CA.'4 ¡.....'~. þ~~ ... t'" ~ " . ~ '" , ... -:. ... ", ~' 'JRCH"'O' CITY OF CAMPBELL Community Development Department. Current Planning June 11, 1998 Ahmad(Ami) A & B Floor Designer 1610 Dell avenue, Unit K Campbell, CA 95008 FAX (408) 866-0615 PH (408) 866-0605 RE: Use of site at 1311 Camden Avenue as a Retail Flooring Store You have requested from the Campbell Community Development Department an evaluation of the potential use of the former 4-day Tire Store site at 1311 Camden Avenue for your flooring business. You indicated that you plan to make improvements in two stages, with store front changes in the first stage when you move in, and building additions in the second stage after a few years on the site. The Community Development Department offers the following evaluation comments: General The plans for the site in the first stage should consider the second stage improvements for efficiency and economy. This will avoid the need to remove many first stage improvements when second stage ones are later added. First Stage You indicated that the first stage, occupancy plans, would include replacement of the west two garage bays with glass retail windows. A Site & Architectural Review Permit is required in this zone for any changes to the building and site. The Director has indicated that the first stage permit could be approved by staff, rather than by the Planning Commission at a public hearing, provided the following criteria could be met: I. The design of the building exterior changes result in the elimination of the auto building appearance, and produce an attractive retail appearance. This would include the addition of landscaping next to the building. 2. The major safety issues be eliminated in the first stage. The City Traffic Engineer has identified the major safety problems as: A. the parking arrangement which presently has vehicles on the far left oriented so they back into the sidewalk. These should be striped so they are parallel to the sidewalk (see diagram); and B. the circulation arrangement. The east driveway should be signed for "entrance only", and the west driveway for "exit only" . 70 North First Street' Campbell, California 95008.1423 ' TEL 408,866,2140 ' FAX 408,866,8381 'TOO 408,866,2790 ~ . ... f' C. The trash enclosure be reconstructed. This enclosure should meet the following design provIsIOns: i. larger in size, with the size to accommodate the special size and amount of your flooring business trash needs; ii. a concrete floor and staging pad to prevent the wheels from sinking into the pavement on hot days; iii. Walls a minimum 6' height, of sight-obscuring masonry, and a sight- obscuring gate; iv. Landscaping around the trash enclosure, with the use of a vine to grow on the walls recommended. D. The landscape areas be brought back to life. This will include the repair or replacement of the irrigation system, trees added or replaced, including the one missing street tree, and shrubs and groundcover. Please refer to the attached diagram for where trees should be added. Second Stage With the addition of building square footage, the following changes should be planned for: 1. The driveways be narrowed. The present driveways are 40 feet to over 50 feet. One- way commercial driveways, that are generous in size for trucks and the traffic speed on Camden, would be 25 feet wide 2. The amount of pavement be reduced, and landscaping increased. This should include landscaping adjacent to the building, and an increase in the size of the planter between the new, narrower driveways. Business Operation At all stages, the business would need to be operated to meet the following standards: 1. No work done outside. 2. No outside storage. 3. Business engaged in selling new merchandise and products at retail. 4. No storage of industrial vehicles, except for the purposes of loading and unloading. 5. No storage or warehousing of merchandise or products for sale other than by retail. 6. No lightning which produces glare for neighbors or drivers of vehicles along the street. 7. All signage to have City permits, and to meet City sign code.] 8. No work which creates a nuisance for the neighboring uses such as excessive noise, dust, fumes, vibration, etc. If you have any questions, please do not hesitate to call me at 866-2193. Sincerely, '\1'/7-- Barbara Ryan, AICP Planner I ~ ..- , T'