Pre-Application - 2000CITY OF CAMPBELL
Community Development Department. Current Planning
March 15,2000
Mr. Bob Hughes
The Building Works
2998 S. Bascom Avenue
San Jose, CA 95124
Subject:
Pre-application: New office building at 2075 Winchester Blvd
PRE 2000-13
Dear Mr. Hughes,
Thank you for your preliminary application for a new two-story commercial/office building at 2075
Winchester Boulevard. The plans were distributed to the City's Architectural Advisor, Public
Works Department, Building Division, Planning Division, and County Fire Department. The
comments ITom the Public Works Department and the County Fire Department are attached. The
Building Division did not have any comments at this time. Below, please find comments ITom the
Planning Division.
Zoning
The project site is zoned C-2-S (General Commercial). The General Plan designation is
Commercial. The proposed use is consistent with the zoning and general plan designation. The
proposed project will require a Site and Architecture Review Permit. This Permit is approved by the
Planning Commission at a public hearing.
Use
The existing buildings are approved for commercial, retail, and office uses only. The proposed
project provides one parking space per 200 square feet of building floor space, meeting the parking
requirement for retail stores or speculative commercial buildings. Since the proposed building will
not have disabled access to the second floor, this floor will be restricted to office uses only.
Landscaping
All applications for development within the C-2-S zoning district are required to provide a
minimum often percent of the net site area in landscaping. The landscaping areas should be shown
on the site plan. This should include landscaping for the entire site, not just the rear portion. The
existing landscaping on site is minimal and needs to be upgraded. Additional requirements include:
1. Continuous landscaped areas along the public street frontages of all developments. This ITontage
landscape must comply with the City's Streetscape Standards (included). Since this project will add
70 North First Street. Campbell, California 95008.1423 . TEL 408.866.2140 . FAX 408.866.8381 . TDD 408.866.2790
T!
Bob Hughes - 2075 Winchester Blvd PRE 2000-13
Page 2
March 15,2000
33% new square footage to the site, the full Streetscape treatment is required (insofar as possible
given the placement of the existing buildings). These Standards require a 10' wide sidewalk with 4'
x 4' tree wells adjacent to the curb. The property owner will be required to dedicate the necessary
land to the City to incorporate the sidewalk into the public right-of-way. Landscaping behind the
sidewalk shall be a minimum of five feet in width, measured at right angles to the street, and
exclusive of any parking overhang. Frontage landscaping shall consist of turf, groundcover, shrubs,
trees, and boulders in combination to provide attractive screening of paved areas. You are
encouraged to contact me to discuss how this request may be implemented on your site.
2. A minimum foUr-foot planter strip shall be provided along abutting property lines.
3. Where the ITontage and perimeter landscaping requirement does not provide the minimum
coverage often percent ofthe site area, additional landscaping areas in an amount which makes up
the difference shall be provided.
4. Where twenty-five or more parking spaces are provided, an interior landscaping area is required
in addition to the perimeter and frontage landscaping areas. The interior landscaping is to be
provided at a rate of twenty square feet for each additional uncovered parking space over twenty-
five. For the amount of parking provided in the proposed site plan for this project, an additional 720
square feet of interior landscaping would be required. This landscaping should be in the form of tree
wells, planting islands, and other landscaping in the parking lot area.
Parking
While the parking requirement is currently met, the number of parking spaces may decrease when
the required landscaping is included in the site plan.
Building Design/Site Layout
Architectural and site evaluation has been performed by the Planning staff and the City's
Architectural Advisor. These are the comments concerning the site plan and the architecture of the
proposed buildings.
The new plans indicate an exterior stairway and walkway for the second floor of the new building.
It is recommended that the exterior stairway and walkway be incorporated into the interior of the
building.
The plans indicate that access to the rear parking area will be provided via a l2-foot wide driveway.
The opening is not wide enough to accommodate two-way traffic and will not be supported by staff.
You are requested to redesign the project to provide adequate two-way access to the rear parking
lot.
The existing buildings were constructed in the 1970's and it appears that the new building has been
designed to mirror that style. It is recommended that a more contemporary building design be used
- ..-
. TI
Bob Hughes - 2075 Winchester Blvd PRE 2000-13
Page 3
March 15,2000
and that the existing buildings be remodeled to reflect the new design concept. It is suggested that
the new building be incorporated into the floor plan of the existing building. I've attached a copy of
similar projects recently approved by the Planning Commission. I hope you find them helpful in .
understanding what the Commission expects in terms of architectural design.
Screening
Any use conducted in a C-2 district shall be effectively screened at the property line ITom any
abutting residentially zoned property. The screening required shall include a masonry wall a
minimum of six feet in height. Such screening shall also include trees and plants to effectively
screen such use ITom the adjoining residentially zoned property.
Lighting
Any lighting for any use within the C-2 district shall be so arranged and shielded so that light will
be reflected away ITom adjacent property in a residential district, and so that there will be no glare
which will cause unreasonable annoyance to occupants of properties in such residential district, or
otherwise interfere with the public health, safety or welfare.
These comments are intended as preliminary only. Additional comments and requirements may be
forthcoming.
Please do not hesitate to contact me at (408) 866-2193 to discuss the application process and for
further assistance with this project.
Sincerely,
8CL~~
Darcy Smith
Planner I
Enclosure: Public Works Department Comments and Preliminary Conditions of Approval,
3/1312000
Fire Department Preliminary Development Review Comments, 3/6/2000
Campbell Streetscape Standards
cc:
Sharon Fierro, Interim Community Development Director
Harold Housley, Land Development Engineer
Bill Bruckart, Building Official
- ..-
TI
FIRE D EP ARTMENT
SANTA ClARA COUNTY
CONTROL NUMBER
14700 Winchester Blvd., Los Gatos, CA 95032-1818
(408) 378-4010 (phone) . (408) 378-9342 (fax)
BLDG PERMIT NUMBER
PLAN REVIEW NUMBER 00- 0425
ALE NUMBER PRE 20-13
DEVELOPMENT
REVIEW
COMMENTS
CODE/SEC.
I SHEET n REQUIREMENT
I Pre-application review of a proposed new 4,015 square foot office building.
I
UFC
Appendix
III-A
1 Review of this Developmental proposal is limited to acceptability of site access
and water supply as they pertain to fire department operations, and shall not be
construed as a substitute for formal plan review to determine compliance with
adopted model codes. Prior to performing any work the applicant shall make
application to, and receive from, the Building Department all applicable
construction permits.
2 Required Fire Flow: Required fire flow for this project is 1,750 GPM at 20 psi
residual pressure. The required fire flow is available from area water mains and
fire hydrant(s) which are spaced at the required spacing.
UFC
903.2
3 Required Access to Water Supply (Hydrants): Portions of the structure(s) are
greater than 150 feet of travel distance from the centerline of the roadway
containing public fire hydrants. Provide an on-site fire hydrant OR provide an
approved fire sprinkler system throughout all portions of the building.
UFC
902.2.2
I 4 Fire Apparatus (Engine) Access Roads Required: Provide access roadways with
, a paved all weather surface, a minimum unobstructed width of 20 feet, vertical
clearance of 13 feet 6 inches, minimum circulating turning radius of 36 feet
outside and 23 feet inside, and a maximum slope of 15%. Installations shall
conform with Fire Department Standard Details and Specifications sheet A-I.
I
I
I
City PLANS SPECS NEW RMDL AS OCCUPANCY CONST. TYPE PERMITTEE DATE I PAGE
CBL D D D D D LAMAR HENDERSON, AlA 3/6/2000 ~OF~
SECJFLOOR I AREA LOAD DESCRIPTION BY
Commercial Development Hokanson, Wayne
NAME OF PROJECT LOCATION
OFFICE BUILDING 2075 Winchester Bl
A California Fire Protection District serving Santa Clara County and the communities of
Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and Saratoga
""'--".-'--"--'"
-. -.. rr-'" .
CODE/SEC.
UFC
902.2.2.4
UFC
902.2.4.1
UFC
901.4.2
CBL
SECJFLOOR
FIRE D EP ARTMENT
SANTA ClARA COUNTY
CONTROL NUMBER
14700 Winchester Blvd., Los Gatos, CA 95032-1818
(408) 378-4010 (phone) . (408) 378-9342 (fax)
BLDG PERMIT NUMBER
PLAN REVIEW NUMBER 00- 0425
RLENUMBER PRE 20-13
DEVELOPMENT
I SHEET ~ REQUIREMENT
! I i
5 Fire Department (Engine) Roadway Turn-arounq Requ~ Provide an
approved fire department engine roadway turnaround with a minimum radius
of 36 feet outside and 23 feet inside. Installations shall conform with Fire
Department Standard Details and Specification sheet A-I. Cul-De-Sac Diameters
shall be no less than 72 feet.
REVIEW
COMMENTS
6 Parking Along Roadways: The required width of fire access roadways shall not
be obstructed in any manner. Parking shall not be allowed along roadways less
than 28 feet in width. Parking will be allowed along one side of the street for
roadways 28-35 feet in width. For roadways equal to or greater than 36 feet
parking will be allowed on both sides of the roadway. Roadway widths shall be
measured face to face of curb. Parking spaces are based on an 8 ft wide space.
7 Fire Lane Marking Required: Provide marking for all roadways within the
project. Markings shall be per fire department specifications. Installations
shall also conform to Local Government Standards and Fire Department
Standard Details and Specifications A-6.
City PLANS SPECS NEW RMDL AS
OCCUPANCY CONST. TYPE
PERMITTEE
DATE
PAGE
0 0 0001
LAMAR HENDERSON, AlA
3/6/2000 ~ OF~
BY
AREA
LOAD
DESCRIPTION
Commercial Development
LOCATION
Hokanson, Wayne
NAME OF PROJECT
OFFICE BUILDING
2075
Winchester Bl
A California Fire Protection District serving Santa Clara County and the communities of
Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and Saratoga
. ----_'____0'00 '00'00__"" .....-... _"00 ,_oo,----"o_,-"---".,,o_,.,,-,--------_oo_--'T'"o__o,
MEMORANDUM
CITY OF CAMPBELL PUBLIC WORKS DEPARTMENT
TO: Darcy Smith, Project Planner DATE:
FROM: kill Helms, Land Development Manager . ~ /
~:arold Housley, Land Development Engineer{r
3/10/00
Site Address: 2075 Winchester Boulevard
For File No(s): PRE 2000-13
Project Description: New office building at rear of site with two existing buildings
Applicant: Annette Martin-Pettyjohn
PUBLIC WORKS DEPARTMENT COMMENTS AND PRELIMINARY CONDITIONS
OF APPROV AL
In 1974, an application was processed and approved for construction of Building 2 as shown
on the applicant's current site plan. Building 1 was already in existence. In 1977, the
applicant processed another application to construct two freestanding, one-story buildings on
the westerly portion of the site. The buildings were not constructed.
The current application is for a new, two-story building also on the westerly portion of the
property. An auto passageway is proposed thru to lower level to access the new parking area
at the rear of the site. The traffic engineer has expressed concern about the traffic circulation
as summarized in his attached memo.
The existing on-site parking lot pavement should be replaced.
Potential conditions of approval for construction of a new building are summarized below.
Street Improvements: Prior to issuance of any grading or building permits for the site,
the applicant shall execute a street improvement agreement and shall cause plans for
public Street Improvements to be prepared by a registered civil engineer, pay fees, post
security and provide insurance necessary to obtain an encroachment permit for
construction of the public improvements, as required by the City Engineer. The plans
shall include the following:
. Removal of the existing driveway approach and construction of a new ADA compliant
driveway approach.
. Repair of existing sidewalk as needed.
Utility Installation Plan: Prior to issuance of building permits for the site, the applicant
shall submit a Utility Installation Coordination Plan and Schedule for approval by the City
Engineer for installation of street improvements and/or abandonment of all utilities.
Streets which have been resurfaced within the previous 5 years will require boring and
jacking for all new utility installations. Applicant shall also prepare pavement restoration
plans for approval by the City Engineer prior to any utility installation or abandonment.
Page 1 of 2
TI
Site Address: 2075 Winchester Boulevard
For File No(s): PRE 2000-13
Project Description: New office building at rear of site with two existing buildings
Applicant: Annette Martin-Pettyjohn
PUBLIC WORKS DEPARTMENT
CONDITIONS OF APPROVAL
COMMENTS
AND
PRELIMINARY
Maintenance Security: Prior to issuance of occupancy approval for the site, all public
street improvements required by the street improvement agreement and the encroachment
permit must be completed and accepted by the City and the applicant must provide a one-
year Maintenance Security in an amount of 25 % of the Faithful Performance Bond.
Storm Drain Area Fee: Prior to issuance of any grading or building permits for the site,
the applicant shall pay the required Storm Drain Area fee which is $2,219.
Storm Water Pollution Prevention Measures: Prior to issuance of any grading or
building permits, the applicant shall comply with the National Pollution Discharge
Elimination System (NPDES) permitting requirements and the California Storm Water
Best Management Practices handbook prepared by the Storm Water Quality Task Force,
Santa Clara Valley Water District and the City of Campbell Municipal Code regarding
Storm Water Pollution Prevention.
Site Plan: The applicant shall submit a complete and accurate Site Plan in accordance
with the Planning Division's checklist.
j : \landdev\207 5WIN C
Page 2 of 2
rt
Page 1 of 1
Harold Housley
From: Harold Housley
Sent: Tuesday, March 14,200011 :21 AM
To: Matthew Jue
Cc: Harold Housley; Darcy Smith
Subject: RE: Comments on 2029 S. Bascom Ave. and 2075 S. Winchester Blvd.
Mathew, these are onsite issues which I will forward to Planning for their consideration.
Thanks, Harold
-----Original Message-----
From: Matthew Jue
Sent: Tuesday, March 14,2000 11:14 AM
To: Harold Housley
Subject: Comments on 2029 S. Bascom Ave. and 2075 S. Winchester Blvd.
Here are my comments.
2029 S. Bascom Avenue:
1. Show signs and pavement markings for car wash and convenience store drive through aisles,
respectively.
2075 S. Winchester Blvd.:
1. Recommend against 12' aisle width for two directions of traffic. This will lead to poor circulation
especially if new back lot is full.
2. Recommend against parallel parking spaces at parking lot entrance. Existing 90-degree parking
provides same number or more spaces, and parallel parking may result in congestion at driveway and
onto Winchester Boulevard.
03/14/2000
. T!
THE BUILDING WORKS
A CORPORATION
MEMORANDUM
DATE:
February 18, 2000
TO:
CITY OF CAMPBELL
Attention: Planning Department
FROM:
Robert O. Hughes
SUBJECT:
2075 WINCHESTER BLVD. PROJECT
Owner proposes to construct a new two story building consisting of
approximately four thousand, fifteen square feet at the rear 0 n currently
unused space of the above described property. Parking is consistent with
the required spaces.
The property is presently improved with two (2) one story buildings
totaling approximately eight thousand, one hundred s quare feet. The total
building space with the new construction will be approximately twelve
thousand, one hundred square feet. The proposed new construction will
be similar and/or complimentary to the existing structures.
There is existing one story commercial usage to the north and south of the
subject project. To the rear is a two story apartment building.
The added space will be for general offices-commercial use, some of which
will be Owner occupied.
ROHlbs
Submitted
G WORKS
2998 SOUTH BASCOM AVENUE / SAN JOSE, CALIFORNIA 95124 / (408) 559-8850/ FAX (408) 559-3075
CALIFORNIA LICENSE #442850
","'",0""""""""""----'--""""""""""""'" """""'~"---'--"-'-___'_'M'-¡r-""_-""""--""""M"'" ,.M""""""'"