Loading...
PLN2016-34, 35, 36, & 37 ~ 1323 Parsons Avenue - Council Report (signed) (all Attachments) v2 ______________________________________________________________ TITLE Public Hearing to consider the application of Omid Shakeri for a Planned Development Permit (PLN2016-34) for the approval of site configuration resulting in the development of four units, architectural design, and to create lots which do not have frontage on a public street, Tentative Subdivision Map (PLN2016-36) to create four single family lots and one commonly owned lot, Zoning Map Amendment (PLN2016-35) to change the zoning from R-1-6 (Single-Family Residential) to P-D (Planned Development), and Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of covered on property located at 1323 Parsons Avenue. The Planning Commission is recommending that a Mitigated Negative Declaration (PLN2016-37) be adopted for this project. RECOMMENDATION The Planning Commission recommends that the City Council take the following actions: 1. Adopt a Resolution, adopting a Mitigated Negative Declaration (PLN2016-37); 2. Introduce an Ordinance, approving a Zoning Map Amendment (PLN2016-35) to change the zoning district designation from R-1-6 (Single-Family Residential) to P-D (Planned Development); 3. Adopt a Resolution, approving a Tentative Subdivision Map (PLN2016-36) to create four single family lots and one commonly owned lot, subject to the attached Conditions of Approval; 4. Adopt a Resolution, approving a Planned Development Permit (PLN2016-34) for site configuration resulting in the development of four units, architectural design, and creation of lots which do not have frontage on a public street; and 5. Adopt a Resolution, approving a Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of covered, subject to the attached Conditions of Approval. BACKGROUND Property Description: The project site is a 33,263 square-foot property located on the west side of Parsons Avenue, south of Camden Avenue, and north of Sharp Avenue in the R-1-6 (Single-Family Residential) Zoning District (reference Attachment 10 – Location Map). The site is currently developed with a 1,615 sq. ft. single-story single- family residence and 480 sq. ft. garage (reference Attachment 8 – Project Plans & City Council Report Item: Category: Public Hearing Date: September 6, 2016 City Council Report ~ September 6, 2016 Page 2 of 3 PLN2015-34 to 37 & PLN2016-222 ~ 1323 Parsons Avenue Tentative Subdivision Map; Sheet A1.2). Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. Applicant’s Proposal: The applicant is seeking approval of a Planned Development Permit to allow the construction of four new two-story single-family residences, a Zone Change to allow a zone district change from R-1-6 (Single Family Residential) to P-D (Planned Development), Vesting Tentative Subdivision Map to allow the creation of five lots (four developable) from a single parcel and Parking Exception Permit to allow uncovered parking spaces to be provided in lieu of required covered parking. As the project includes a Zone Change, an Initial Study and Mitigated Negative Declaration (PLN2016-37) was prepared. DISCUSSION Planning Commission Review: At its meeting of August 23, 2016, the Planning Commission held a public hearing on the applicant’s request. During the public comment period, the Commission took comment from Thais Ott (resident of 225 Sharp Avenue) expressing concerns about the proximity of the barbeque/park bench area on the common lot to her property and Alvin Hieb (resident of 256 Sharp Avenue) expressing concerns with commercial parking in the neighborhood unrelated to the subject permit. The Commission’s discussion focused on the project’s barbeque/amenity area, adequacy of parking, coordination of utility undergrounding with adjacent uses, proposed tree species, and considering adding requirements for Home Owners Associations to register their contact information with utility companies to assist with communications in the event of emergencies. After due consideration, the Planning Commission voted unanimously to recommend the City Council approve the item, modifying conditions of approval to 1) remove the requirement to provide a barbeque, 2) allowing the selection of Crape Myrtle trees to be provided in lieu of evergreen trees, 3) allowing a 9-foot high acoustically effective barrier to be constructed behind a segment of Lot 4 in compliance with the recommendations of the project acoustic report (reference Attachment 11), 4) adding a requirement for the applicant and staff to discern the connection requirements for adjacent properties which may result from undergrounding, 5) adding a provision to the project CC&R’s which requires the HOA to register their contact information with local utility companies, and 6) requiring that the five guest parking spaces, located on the common lot, be restricted only to guests and include adequate signage to convey this restriction to future owners. FISCAL IMPACTS In addition to the entitlement application fees already paid, and permits fees required for building permit and off-site improvement review, the developer will contribute approximately $54,453 in Park Impact Fees. ALTERNATIVES 1. Approve the proposed project subject to additional and/or modified Conditions of Approval. 2. Continue for further review. 3. Deny the proposed project. City Council Report ~ September 6, 2016 Page 3 of 3 PLN2015-34 to 37 & PLN2016-222 ~ 1323 Parsons Avenue Prepared by: Stephen Rose, Associate Planner Reviewed by: Paul Kermoyan, Community Development Director Approved by: Mark Linder, City Manager Attachments: 1. Draft City Council Resolution (Mitigated Negative Declaration) 2. Draft City Council Ordinance (Zoning Map Amendment) 3. Draft City Council Resolution (Vesting Tentative Subdivision Map) 4. Draft City Council Resolution (Planned Development Permit) 5. Draft City Council Resolution (Parking Modification Permit) 6. Location Map 7. Revised Project Plans & Tentative Subdivision Map 8. Initial Study, Draft Mitigated Negative Declaration & MMRP 9. SARC Memo – July 26, 2016 10. Planning Commission Staff Report ~ August 23, 2016 11. Acoustic Report prepared by Edward L. Pack Associates RESOLUTION NO. ______ BEING A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CAMPBELL ADOPTING A MITIGATED NEGATIVE DECLARATION (PLN2016-37) FOR A ZONING MAP AMENDMENT (PLN2016-35); TENTATIVE SUBDIVISION MAP (PLN2016-36); PLANNED DEVELOPMENT PERMIT (PLN2015-34), AND PARKING MODIFICATION PERMIT (PLN2016-222); TO ALLOW THE DEVELOPMENT OF FOUR UNITS ON PROPERTY LOCATED AT 1323 PARSONS AVENUE. After notification and public hearing, as specified by law, and after presentation by the Community Development Director, proponents and opponents, the City Council did determine that the adoption of a Mitigated Negative Declaration provides full and adequate environmental review for approval of a Zoning Map Amendment (PLN2016-35); Tentative Subdivision Map (PLN2016-36); Planned Development Permit (PLN2016-35); and a Parking Modification Permit (PLN2016-222); to allow the development of four units on property located at 1323 Parsons Avenue. The City Council finds as follows with regard to recommended adoption of a Mitigated Negative Declaration (PLN2016-37): Environmental Finding 1. An Initial Study has been prepared for the project which provides documentation for the factual basis for concluding that a Mitigated Negative Declaration (PLN2016-37) may be adopted since no substantial evidence exists, in light of the whole record, that the project may have a significant effect on the environment as conditioned. Evidentiary Findings 2. The proposed project ("project") includes a Planned Development Permit (PLN2016- 34) for the approval of site configuration, architectural design and to create residential lots which do not have frontage on a public street, Tentative Subdivision Map (PLN2016-36) to create four developable single family lots and one commonly owned lot, Zoning Map Amendment (PLN2016-35) to change the zoning from R-1-6 (Single- Family Residential) to P-D (Planned Development), and Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of covered. 3. The project site is a 33,263 square-foot property located on the west side of Parsons Avenue, south of Camden Avenue, and north of Sharp Avenue. 4. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. 5. The lot is currently developed with one single-family residence that will be demolished as part of the proposed subdivision. 6. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. City Council Resolution PLN2016-36 – 1323 Parsons Avenue Adopting a Mitigated Negative Declaration (PLN2016-37) Page 2 of 4 7. The project site is zoned R-1-6 (Residential Single-Family) as shown on the Campbell Zoning Map and will be rezoned to P-D (Planned Development). 8. The project site is designated Low Density Residential (<6 Units / Gr. Acre) as shown on the Campbell General Plan Map. 9. The proposed residential land use, at a density of approximately 5 units/gr. acre, is consistent with the allowable land use and maximum density permitted by the Low Density Residential (< 6 units per gross acre) General Plan land use designation. 10. The proposed Tentative Subdivision Map may be approved concurrently, and subject to a Planned Development Permit, and Zoning Map Amendment. 11. The project would be consistent with the following General Plan policies and strategies: Policy LUT-3.1: Variety of Residential Densities: Provide land use categories for and maintenance of a variety of residential densities to offer existing and future residents of all income levels, age groups and special needs sufficient opportunities and choices for locating in Campbell. Strategy LUT-5.2a: Neighborhood Compatibility: Promote new residential development and substantial additions that are designed to maintain and support the existing character and development pattern of the surrounding neighborhood, especially in historic neighborhoods and neighborhoods with consistent design characteristics. Strategy LUT-9.3e: Building Materials: Encourage the use of long-lasting, high quality building materials on all buildings to ensure the long-term quality of the built environment. Strategy LUT-17.1b: Landscaping: Ensure that new developments provide new tree plantings, shrubs, greenery and other landscaping materials, and preserve existing trees and shrubs. 12. The project proposes 13 parking spaces (8 covered, 5 uncovered), where 12 parking spaces (10 covered, 2 uncovered) are required which is allowed with the approval of the associated Parking Modification Permit (PLN2016-68). 13. A draft Mitigation Monitoring and Reporting Program has been provided demonstrating the responsible party and phase of the project that each Mitigation Measure shall be carried out. City Council Resolution PLN2016-36 – 1323 Parsons Avenue Adopting a Mitigated Negative Declaration (PLN2016-37) Page 3 of 4 14. There are no responsible agencies or trustee agencies responsible for resources affected by the project. 15. On the basis of the Initial Study, and as supported by substantial evidence, the project will not have a significant effect on the environment due to the application of uniformly applicable development policies, and incorporation of project-specific mitigation measures agreed to by the project proponent, as specified by the draft Mitigated Negative Declaration. 16. The City of Campbell provided a Notice of Intent to adopt a Mitigated Negative Declaration to the public via the Campbell Express, the County Clerk, and on the City website. 17. The City of Campbell provided a 20-day public review period of the Mitigated Negative Declaration pursuant to the California Environmental Quality Act Guidelines. The 20-day public review period was from August 3, 2016 to August 23, 2016. 18. The mitigation measures identified in the Mitigated Negative Declaration are included as Conditions of Approval of the Planned Development Permit and/or Tentative Subdivision Map. Based upon the foregoing findings of fact, the City Council further finds and concludes that: 19. The proposed development will clearly result in a more desirable environment and use of the land than would be possible under any other zoning district classification. 20. The proposed development will be compatible with the General Plan of the City and will aid in the harmonious development of the immediate area. 21. The proposed development will not result in allowing more residential units than would be allowed by other residential zoning districts, which are consistent with the General Plan designation of the property. 22. The proposed development will not be detrimental to the health, safety or welfare of the neighborhood or the City as a whole. 23. There is a reasonable relationship and a rough proportionality between the conditions of approval and the impacts of the project. 24. There is a reasonable relationship between the use of the fees imposed upon the project and the type of development project. 25. No substantial evidence has been presented from which a reasonable argument could be made that shows that the project, as currently presented and subject to the City Council Resolution PLN2016-36 – 1323 Parsons Avenue Adopting a Mitigated Negative Declaration (PLN2016-37) Page 4 of 4 required conditions of approval, will have a significant adverse impact on the environment. 26. The Mitigated Negative Declaration reflects the independent judgment and analysis of the City Council upon recommendation of the Planning Commission. 27. The Custodian of the Record for the Mitigated Negative Declaration and Initial Study is the Community Development Department of the City of Campbell, located at 70 North First Street, Campbell, California. NOW, THEREFORE, BE IT RESOLVED that the City Council adopts a Mitigated Negative Declaration (PLN2016-37) (attached Exhibit “A”) for a Zoning Map Amendment (PLN2016- 35); Tentative Subdivision Map (PLN2016-36); Planned Development Permit (PLN2016- 34); and a Parking Modification Permit (PLN2016-222); to allow the development of four units on property located at 1323 Parsons Avenue. PASSED AND ADOPTED this _____ day of ___________, 2016, by the following roll call vote: AYES: COUNCILMEMBERS: NOES: COUNCILMEMBERS: ABSENT: COUNCILMEMBERS: ABSTAIN: COUNCILMEMBERS: APPROVED: Jason T. Baker, Mayor ATTEST: Wendy Wood, City Clerk ORDINANCE NO. _____ BEING AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF CAMPBELL APPROVING A ZONING MAP AMENDMENT (PLN2016- 35) TO CHANGE THE ZONING DISTRICT DESIGNATION FROM R-1-6 (SINGLE-FAMILY RESIDENTIAL) TO P-D (PLANNED DEVELOPMENT) FOR THE PROJECT LOCATED AT 1323 PARSONS AVENUE. After notification and public hearing, as specified by law and after presentation by the Community Development Director, proponents and opponents, the hearing was closed. The City Council finds as follows with regard to the recommended approval of a Zoning Map Amendment (PLN2016-35): Environmental Finding 1. An Initial Study has been prepared for the project which provides documentation for the factual basis for concluding that a Mitigated Negative Declaration (PLN2016-37) may be adopted since no substantial evidence exists, in light of the whole record, that the project may have a significant effect on the environment as conditioned. Evidentiary Findings 2. The proposed project ("project") includes a Planned Development Permit (PLN2016- 34) for the approval of site configuration, architectural design and to create residential lots which do not have frontage on a public street, Tentative Subdivision Map (PLN2016-36) to create four developable single family lots and one commonly owned lot, Zoning Map Amendment (PLN2016-35) to change the zoning from R-1-6 (Single- Family Residential) to P-D (Planned Development), and Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of covered. 3. The project site is a 33,263 square-foot property located on the west side of Parsons Avenue, south of Camden Avenue, and north of Sharp Avenue. 4. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. 5. The lot is currently developed with one single-family residence that will be demolished as part of the proposed subdivision. 6. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. 7. The project site is zoned R-1-6 (Residential Single-Family) as shown on the Campbell Zoning Map and will be rezoned to P-D (Planned Development). City Council Ordinance PLN2016-35 – 1323 Parsons Avenue – Approving a Zoning Map Amendment Page 2 of 4 8. The project site is designated Low Density Residential (<6 Units / Gr. Acre) as shown on the Campbell General Plan Map. 9. The proposed residential land use, at a density of approximately 5 units/gr. acre, is consistent with the allowable land use and maximum density permitted by the Low Density Residential (< 6 units per gross acre) General Plan land use designation. 10. The proposed Tentative Subdivision Map may be approved concurrently, and subject to a Planned Development Permit, and Zoning Map Amendment. 11. The project would be consistent with the following General Plan policies and strategies: Policy LUT-3.1: Variety of Residential Densities: Provide land use categories for and maintenance of a variety of residential densities to offer existing and future residents of all income levels, age groups and special needs sufficient opportunities and choices for locating in Campbell. Strategy LUT-5.2a: Neighborhood Compatibility: Promote new residential development and substantial additions that are designed to maintain and support the existing character and development pattern of the surrounding neighborhood, especially in historic neighborhoods and neighborhoods with consistent design characteristics. Strategy LUT-9.3e: Building Materials: Encourage the use of long-lasting, high quality building materials on all buildings to ensure the long-term quality of the built environment. Strategy LUT-17.1b: Landscaping: Ensure that new developments provide new tree plantings, shrubs, greenery and other landscaping materials, and preserve existing trees and shrubs. 12. The project proposes 13 parking spaces (8 covered, 5 uncovered), where 12 parking spaces (10 covered, 2 uncovered) are required which is allowed with the approval of the associated Parking Modification Permit (PLN2016-68). 13. A draft Mitigation Monitoring and Reporting Program has been provided demonstrating the responsible party and phase of the project that each Mitigation Measure shall be carried out. 14. There are no responsible agencies or trustee agencies responsible for resources affected by the project. 15. On the basis of the Initial Study, and as supported by substantial evidence, the project will not have a significant effect on the environment due to the application of uniformly applicable development policies, and incorporation of project-specific mitigation City Council Ordinance PLN2016-35 – 1323 Parsons Avenue – Approving a Zoning Map Amendment Page 3 of 4 measures agreed to by the project proponent, as specified by the draft Mitigated Negative Declaration. 16. The City of Campbell provided a Notice of Intent to adopt a Mitigated Negative Declaration to the public via the Campbell Express, the County Clerk, and on the City website. 17. The City of Campbell provided a 20-day public review period of the Mitigated Negative Declaration pursuant to the California Environmental Quality Act Guidelines. The 20- day public review period was from August 3, 2016 to August 23, 2016. 18. The mitigation measures identified in the Mitigated Negative Declaration are included as Conditions of Approval of the Planned Development Permit and/or Tentative Subdivision Map. Based upon the foregoing findings of fact, the City Council further finds and concludes that: 19. The proposed amendment is consistent with the goals, policies, and actions of the General Plan. 20. The proposed amendment would not be detrimental to the public interest, health, safety, convenience, or general welfare of the city. 21. The proposed amendment is internally consistent with other applicable provisions of this Zoning Code. 22. The parcel is physically suitable (including absence of physical constraints, access, compatibility with adjoining land uses, and provision of utilities) for the requested zoning designation(s) and anticipated land uses/project. After due consideration of all evidence presented, the City Council of the City of Campbell does ordain as follows: SECTION ONE: That this Ordinance be adopted to approve a Zoning Map Amendment (PLN2016-35) to amend the Zoning Map designation from R-1-6 (Residential Single-Family) to P-D (Planned Development) for property located at 1323 Parsons Avenue, as depicted by Exhibit A. SECTION TWO: This Ordinance shall become effective thirty (30) days following its passage and adoption and shall be published, one time within fifteen (15) days upon passage and adoption in the Campbell Express, a newspaper of general circulation in the City of Campbell, County of Santa Clara. City Council Ordinance PLN2016-35 – 1323 Parsons Avenue – Approving a Zoning Map Amendment Page 4 of 4 PASSED AND ADOPTED this _______day of ___________, 2016, by the following roll call vote: AYES: COUNCILMEMBERS: NOES: COUNCILMEMBERS: ABSENT: COUNCILMEMBERS: ABSTAIN: COUNCILMEMBERS: APPROVED: Jason T. Baker, Mayor ATTEST: Wendy Wood, City Clerk EXHIBIT A Project Location Map RESOLUTION NO. _____ BEING A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CAMPBELL APPROVING A TENTATIVE SUBDIVISION MAP (PLN2016-36) TO CREATE FOUR SINGLE-FAMILY LOTS AND ONE COMMONLY-OWNED LOT ON PROPERTY LOCATED AT 1323 PARSONS AVENUE. After notification and public hearing, as specified by law and after presentation by the Community Development Director, proponents and opponents, the hearing was closed. The City Council finds as follows with regard to the approval of a Tentative Subdivision Map (PLN2016-36): Environmental Finding 1. An Initial Study has been prepared for the project which provides documentation for the factual basis for concluding that a Mitigated Negative Declaration (PLN2016-37) may be adopted since no substantial evidence exists, in light of the whole record, that the project may have a significant effect on the environment as conditioned. Evidentiary Findings 2. The proposed project ("project") includes a Planned Development Permit (PLN2016- 34) for the approval of site configuration, architectural design and to create residential lots which do not have frontage on a public street, Tentative Subdivision Map (PLN2016-36) to create four developable single family lots and one commonly owned lot, Zoning Map Amendment (PLN2016-35) to change the zoning from R-1-6 (Single- Family Residential) to P-D (Planned Development), and Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of covered. 3. The project site is a 33,263 square-foot property located on the west side of Parsons Avenue, south of Camden Avenue, and north of Sharp Avenue. 4. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. 5. The lot is currently developed with one single-family residence that will be demolished as part of the proposed subdivision. 6. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. 7. The project site is zoned R-1-6 (Residential Single-Family) as shown on the Campbell Zoning Map and will be rezoned to P-D (Planned Development). 8. The project site is designated Low Density Residential (<6 Units / Gr. Acre) as shown on the Campbell General Plan Map. City Council Resolution PLN2016-34 – Approving a Tentative Subdivision Map –1323 Parsons Avenue Page 2 of 4 9. The proposed residential land use, at a density of approximately 5 units/gr. acre, is consistent with the allowable land use and maximum density permitted by the Low Density Residential (< 6 units per gross acre) General Plan land use designation. 10. The proposed Tentative Subdivision Map may be approved concurrently, and subject to a Planned Development Permit, and Zoning Map Amendment. 11. The project would be consistent with the following General Plan policies and strategies: Policy LUT-3.1: Variety of Residential Densities: Provide land use categories for and maintenance of a variety of residential densities to offer existing and future residents of all income levels, age groups and special needs sufficient opportunities and choices for locating in Campbell. Strategy LUT-5.2a: Neighborhood Compatibility: Promote new residential development and substantial additions that are designed to maintain and support the existing character and development pattern of the surrounding neighborhood, especially in historic neighborhoods and neighborhoods with consistent design characteristics. Strategy LUT-9.3e: Building Materials: Encourage the use of long-lasting, high quality building materials on all buildings to ensure the long- term quality of the built environment. Strategy LUT-17.1b: Landscaping: Ensure that new developments provide new tree plantings, shrubs, greenery and other landscaping materials, and preserve existing trees and shrubs. 12. The project proposes 13 parking spaces (8 covered, 5 uncovered), where 12 parking spaces (10 covered, 2 uncovered) are required which is allowed with the approval of the associated Parking Modification Permit (PLN2016-68). 13. A draft Mitigation Monitoring and Reporting Program has been provided demonstrating the responsible party and phase of the project that each Mitigation Measure shall be carried out. 14. There are no responsible agencies or trustee agencies responsible for resources affected by the project. 15. On the basis of the Initial Study, and as supported by substantial evidence, the project will not have a significant effect on the environment due to the application of uniformly applicable development policies, and incorporation of project-specific mitigation measures agreed to by the project proponent, as specified by the draft Mitigated Negative Declaration. City Council Resolution PLN2016-34 – Approving a Tentative Subdivision Map –1323 Parsons Avenue Page 3 of 4 16. The City of Campbell provided a Notice of Intent to adopt a Mitigated Negative Declaration to the public via the Campbell Express, the County Clerk, and on the City website. 17. The City of Campbell provided a 20-day public review period of the Mitigated Negative Declaration pursuant to the California Environmental Quality Act Guidelines. The 20-day public review period was from August 3, 2016 to August 23, 2016. 18. The mitigation measures identified in the Mitigated Negative Declaration are included as Conditions of Approval of the Planned Development Permit and/or Tentative Subdivision Map. Based upon the foregoing findings of fact, the City Council further finds and concludes that: 19. The proposed Tentative Subdivision Map is consistent with the General Plan and Zoning Ordinance of the City. 20. The proposed Tentative Subdivision Map does not impair the balance between the housing needs of the region and the public service needs of its residents and available fiscal and environmental resources. 21. The design of the Tentative Subdivision Map provides, to the extent feasible, for future passive or natural heating and cooling opportunities. 22. The development and uses will be compatible with the General Plan of the City and will aid in the harmonious development of the immediate area. 23. There is a reasonable relationship and a rough proportionality between the Conditions of Approval and the impacts of the project. 24. There is a reasonable relationship between the use of the fees imposed upon the project and the type of development project. 25. No substantial evidence has been presented from which a reasonable argument could be made that shows that the project, as currently presented and subject to the required Conditions of Approval, will have a significant adverse impact on the environment. THEREFORE, BE IT RESOLVED that the City Council approves a Tentative Parcel Map (PLN2016-36) for the Project located at 1323 Parsons Avenue, subject to the attached Conditions of Approval (attached Exhibit “A”). PASSED AND ADOPTED this _______day of ___________, 2016, by the following roll call vote: City Council Resolution PLN2016-34 – Approving a Tentative Subdivision Map –1323 Parsons Avenue Page 4 of 4 AYES: COUNCILMEMBERS: NOES: COUNCILMEMBERS: ABSENT: COUNCILMEMBERS: ABSTAIN: COUNCILMEMBERS: APPROVED: Jason T. Baker, Mayor ATTEST: Wendy Wood, City Clerk EXHIBIT A CONDITIONS OF APPROVAL Tentative Subdivision Map (PLN2016-36) Where approval by the Director of Community Development, City Engineer, Public Works Director, City Attorney or Fire Department is required, that review shall be for compliance with all applicable conditions of approval, adopted policies and guidelines, ordinances, laws and regulations and accepted engineering practices for the item under review. Additionally, the applicant is hereby notified that he/she is required to comply with all applicable Codes or Ordinances of the City of Campbell and the State of California that pertain to this development and are not herein specified. COMMUNITY DEVELOPMENT DEPARTMENT Planning Division 1. Approved Project: Approval is granted for a Tentative Subdivision Map (PLN2016-36) to subdivide a parcel into four developable parcels and one common lot, subject to approval of a Zoning Map Amendment (PLN2016-35) to allow a P-D zoning designation, on property located at 1323 Parsons Avenue. The project shall substantially conform to the Revised Project Plans & Tentative Subdivision Map dated August 9, 2016 except as may be modified by the Conditions of Approval herein. 2. Plan Revisions: Prior to Tract Map submittal, the plans shall reflect the inclusion of the small sliver of driveway over Lot 2 into the Common Lot. Compliance with this requirement shall be to the satisfaction of the Director of Community Development. 3. Approval Expiration: The Tentative Subdivision Map approval is valid for a period of two years from the date of final City Council approval unless an extension is granted prior to the expiration date. Recordation of a Tract Map must occur within this two-year period. 4. Tract Map: The Planned Development Permit approval is contingent upon recordation of the Tract Map to divide the subject property. The Tract Map shall be recorded prior to the issuance of building or grading permits. 5. Indemnity: If determined necessary by the Community Development Director, the applicant shall enter into an agreement satisfactory to the City Attorney to indemnify and defend the City of Campbell, its officers, officials, employees, and agents from any and all actions, liabilities, losses, and torts, including attorney’s fees arising out of or connected unto any challenge to the decision of the City Council on this application. Such agreement shall be executed within the 30 days of the Community Development Director's decision to require it. 6. Planned Development Permit: The Tentative Subdivision Map is contingent upon approval of the Planned Development Permit (PLN2015-34). A Tract Map may not be recorded if the Planned Development Permit expires or is revoked by the City Council. 7. Park Impact Fee: A park impact fee is due upon development of the site, based on the development density ranging from <6 Units per Gross Acre (Low Density), less credit for one legally constructed unit. Prior to recordation of the Tract Map, 75% of this fee Exhibit A - Conditions of Approval Tentative Subdivision Map (PLN2016-36) - 1323 Parsons Avenue Page 2 of 9 is due. The remaining 25% is due prior to issuance of a certificate of building occupancy. The fee is currently set at $18,151 per unit. This fee is subject to change and the fee in effect at the time of payment shall be the fee due. 8. Planning Mitigation Monitoring Fee: Prior to issuance of a demolition permit, the applicant shall pay a $1,000.00 deposit to cover the actual staff cost to ensure compliance with the mitigation monitoring. 9. Equal Access: As codified within the project's CC&Rs, the Home Owners Association shall maintain equal access to all common facilities and amenities for all residents (renters and homeowners) of the project. 10. CEQA Mitigation Measures: The following measures shall be implemented pursuant to the Mitigated Negative Declaration: Mitigation Measure AIR-1: The project applicant shall ensure that construction plans include the BAAQMD Best Management Practices for fugitive dust control. The following will be required for all construction activities within the project area. These measures will reduce fugitive dust emissions primarily during soil movement, grading and demolition activities, but also during vehicle and equipment movement on unpaved project sites: a. Use dust-proof chutes for loading construction debris onto trucks. b. Water or cover stockpiles of debris, soil, and other materials that can be blown by the wind. c. Cover all trucks hauling soil, sand, and other loose materials or require all trucks to maintain at least two feet of freeboard. d. Sweep daily (with water sweepers) all paved access roads, parking areas, and staging areas at the construction site. e. Sweep streets daily (with water sweepers) if visible soil material is carried onto adjacent public streets, as directed by the City Engineer. f. Enclose, cover, water twice daily or, or apply (non-toxic) soil stabilizers to exposed stockpiles (dirt, sand, etc.). g. Install erosion control measures to prevent runoff from the project site. Mitigation Measure CUL-1: If archaeological or paleontological resources are encountered during excavation or construction, construction personnel shall be instructed to immediately suspend all activity in the immediate vicinity of the suspected resources and the City and a licensed archeologist or paleontologist shall be contacted to evaluate the situation. A licensed archeologist or paleontologist shall be retained to inspect the discovery and make any necessary recommendations to evaluate the find under current CEQA guidelines prior to the submittal of a resource mitigation plan and monitoring program to the City for review and approval prior to the continuation of any on-site construction activity. Exhibit A - Conditions of Approval Tentative Subdivision Map (PLN2016-36) - 1323 Parsons Avenue Page 3 of 9 Mitigation Measure GEO-1: The applicant shall comply with the recommendations in the Geotechnical Investigation, dated January 7, 2016 by Wayne L. Ting C.E. (No. C46276) of Wayne Ting & Associates Incorporated. Such recommendations shall be incorporated into the project’s final engineering design to minimize the damage from seismic shaking, unsuitable fill, and other geological deficiencies. The project shall use standard engineering techniques and conform to the requirements of the International Building Code to reduce the potential for seismic damage and risk to future occupants. Mitigation Measure HAZ-1: Prior to issuance of a demolition permit, a qualified contractor shall asses the property for presence of Lead-based paint (LBP) and Asbestos containing building materials (ACBM), and if present, prepare a plan, to the satisfaction of the Building Official, to properly manage and dispose of such materials. Mitigation Measure NOI-1: Mechanical ventilation (HVAC) shall be included in all residences constructed to allow occupants to close doors and windows as desired to achieve additional acoustic isolation. Further, the project building plans shall incorporate dual pane thermal windows and acoustically effective doors with a rated minimum Sound Transmission Class (STC) as recommended by the acoustical study. Mitigation Measure NOI-2: An acoustical study shall be prepared for the project which will study existing noise conditions, the project plans, and provide specific structural recommendations to comply with the noise exposure limits identified in the Campbell General Plan. The project building plans shall incorporate the recommendations as mitigation measures. 11. Utility Boxes and Back-Flow Preventers: The applicant shall submit a plan prior to installation of the underground PG&E utility (transformer) boxes and San Jose Water Company back-flow preventers, indicating the location of the boxes for approval by the Community Development Director. 12. Pad Certification: Following site grading and prior to preparation of individual building pad forms, the following improvements shall be certified by a licensed land surveyor and reviewed by the Community Development Director to determine consistency with the approved plan (grade, pad and drainage). 13. Residential Address Identification: The applicant shall submit a detail sheet showing uniform residential address identification material type and location on the building wall for review and approval by the Community Development prior to the issuance of Building Permits. In order to obtain approval, numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Additionally, number material and color is required to contrast with their background. Exhibit A - Conditions of Approval Tentative Subdivision Map (PLN2016-36) - 1323 Parsons Avenue Page 4 of 9 14. Property Maintenance: The property is to be maintained free of any combustible trash, debris, and weeds until the time that actual construction commences. Any vacant existing structures shall be secured, by having windows boarded up and doors sealed shut, or be demolished or removed from the property (California Fire Code, 2013 Edition). 15. Stormwater and Grading Requirements: The project shall comply with City stormwater and grading requirements (CMC Sec. 20.80.020, 21.16.100, and 14.02), as more specifically itemized in the Public Works Department Conditions of Approval for the Tentative Subdivision Map. 16. Covenants, Codes and Restrictions (CC&R’s): Prior to issuance of recordation of the Tract Map, the applicant shall submit for review and approval by the City a copy of the draft CC&R’s which shall include the following: a. Formation of a Homeowner’s Association to ensure the long-term maintenance of buildings and property. b. Continued architectural controls to ensure the architectural integrity of the project. c. Definition of common areas to be maintained and provision of maintenance for these areas. d. Provision which shall define the rights of use, allowable landscape or open space improvements. e. Provision of a funding mechanism to ensure maintenance and upkeep of common areas. f. Provision to provide ongoing maintenance of the required private roadways, landscaping, and sound walls as necessary. Graffiti removal from sound walls and fences within a reasonable period of time. g. Provision that requires ongoing maintenance of the landscaped park strip and tree wells in the public right of way. This includes, but is not limited to: trees, lawn, plantings, irrigation, etc. Trees shall not be pruned in a manner that would not allow the tree to grow to a mature height. h. Provision for regular monitoring and maintenance of the stormwater system, in accordance with the manufacturer’s recommendations. i. Provision for regular monitoring and maintenance of the private sanitary system as described by the designing engineering, and as approved by the City Engineer. j. Provision for the availability of interior garage space for the parking of vehicles at all times. k. Provision to prohibit the use of outside parking spaces for storage purposes, including boats, trailers, and recreational vehicles. l. Provision to prohibit vehicle washing, and vehicle repair and maintenance activities in the project site, including, but not limited to garages and common parking areas. m. Provision that requires that all landscaping, including but not limited infiltration plantings, be maintained as depicted on the final landscaping plan. n. Provision guaranteeing equal access to all common facilities and amenities by all residents (renters and homeowners) of the project. Exhibit A - Conditions of Approval Tentative Subdivision Map (PLN2016-36) - 1323 Parsons Avenue Page 5 of 9 o. Provision to contact local utility companies and register contact information for HOA to assist with communications in the event of utility service emergencies. 17. Compliance with Other Regulations: The applicant shall comply with other state, county, and city ordinances that pertain to the proposed project. 18. Construction Activity: The following standards shall apply to construction of the project: • Construction Hours (CMC 18.04.052): Construction activity shall be limited to the hours of eight a.m. and five p.m. daily, Monday through Friday. Saturday hours of construction shall be nine a.m. and four p.m. There shall be no construction activity on Sundays or National Holidays. • Construction Noise (CMC 18.04.052): No loud environmentally disruptive noise over fifty dbs., such as air compressors without mufflers, continuously running motors or generators, loud playing musical instruments or radios will be allowed during the authorized hours of construction, Monday through Saturday, where such noise may be a nuisance to adjacent residential neighbors. Such nuisances shall be discontinued. • Contractor Contact Information Posting: The project site shall be posted with the name and contact number of the lead contractor in a location visible from the public street prior to issuance of building permits. PUBLIC WORKS DEPARTMENT 19. Response Letter: Upon submittal of the Final Map, the Street Improvement Plans and the Grading and Drainage Plans, the applicant shall provide an itemized response letter verifying that all the Public Works Conditions of Approval have been met or addressed. 20. Final Map: Prior to issuance of any grading or building permits for the project, the applicant shall submit a Final Map for review by the City and recordation, upon approval by the City Council, pay various fees/deposits and submit the map in a digital format acceptable to the City. 21. Covenants, Conditions, and Restrictions: Provide copies of CC&Rs for review by the City prior to recordation of the Final Map and CC&Rs. A maintenance plan of the storm drain facilities and the pervious concrete on Lot A shall be part of the CC&Rs. If the proposed use of pervious concrete in Lot A is to be removed in the future, this removal if replaced with an impervious material will require stormwater treatment for the entire subdivision and will then be subject to C.3 requirements. Removal of the pervious concrete requires City approval. 22. Preliminary Title Report: Upon submittal of the Final Map, the applicant shall provide a current (within the past 6 months) Preliminary Title Report. Exhibit A - Conditions of Approval Tentative Subdivision Map (PLN2016-36) - 1323 Parsons Avenue Page 6 of 9 23. Right-of-Way for Public Street Purposes: Upon recordation of the Final Map, the applicant shall fully complete the process to cause additional right-of-way to be granted in fee for public street purposes along the Parsons Avenue frontage to accommodate a 30-foot half street width, unless otherwise approved by the City Engineer. The applicant shall submit the necessary documents for approval by the City Engineer, process the submittal with City staff’s comments and fully complete the right-of-way process. The applicant shall cause all documents to be prepared by a registered civil engineer/land surveyor, as necessary, for the City’s review and recordation. 24. Public Service Easement: Upon recordation of the Final Map, the applicant shall grant a 5-ft public service easement on private property contiguous with the public right-of- way along the Parsons Avenue frontage, unless otherwise approved by the City Engineer. The applicant shall cause all documents to be prepared by a registered civil engineer/land surveyor, as necessary, for the City’s review and recordation. Private utilities such as the PG&E joint trench depicted in the park strip shall be relocated so as not to interfere with the future public street trees root system. The private utilities (JT and private water meters) shall not be placed in areas designated as public service easements. 25. Monumentation for Final Map: Prior to recordation of the Final Map, the applicant shall provide a cash deposit of $10,000.00 for setting all monuments required to be shown on the Final Map and as set forth per section 20.76.010 of the Campbell Municipal Code including but not limited to setting permanent pipe monuments (three-fourths inch galvanized steel pipe two feet long approximately six inches below finished grade) at each boundary of all lot corners within a subdivision, along the exterior boundary lines at intervals of approximately five hundred feet and at all beginning of curves and ending of curves on property lines, and monument boxes at intersections of all street monument line tangents. 26. Demolition: Prior to recording of the Final Map the applicant shall obtain a demolition permit and remove any nonconforming structures. 27. Soils Report: Upon submittal of the Final Map, applicant shall provide a soils report prepared by a registered geotechnical or civil engineer. 28. Grading and Drainage Plan: Prior to recordation of the Final Map, the applicant shall conduct hydrology studies based on a ten-year storm frequency, prepare an engineered grading and drainage plan, and pay fees required to obtain necessary grading permits. Prior to occupancy, the design engineer shall provide written certification that the development has been built per the engineered grading and drainage plans. In addition, a plan review letter will be required of the Geotechnical engineer for the entire grading and drainage system which should include but is not limited to a review of the subsurface of the non-compacted biotreatment material that may have potential for subsurface failure and surface failure due to vehicle loads. Exhibit A - Conditions of Approval Tentative Subdivision Map (PLN2016-36) - 1323 Parsons Avenue Page 7 of 9 29. Storm Drain Area Fee: Prior to recordation of the Final Map, the applicant shall pay the required Storm Drain Area fee, currently set at $2,120.00 per net acre, which is $1,717.00. 30. Stormwater Pollution Prevention Measures: Prior to issuance of any grading or building permits, the applicant shall comply with the National Pollution Discharge Elimination System (NPDES) permit requirements, Santa Clara Valley Water District requirements, and the Campbell Municipal Code regarding stormwater pollution prevention. The primary objectives are to improve the quality and reduce the quantity of stormwater runoff to the bay. Resources to achieve these objectives include Stormwater Best Management Practices Handbook for New Development and Redevelopment (“CA BMP Handbook”) by the California Stormwater Quality Association (CASQA), 2003; Start at the Source: A Design Guidance Manual for Stormwater Quality Protection (“Start at the Source”) by the Bay Area Stormwater Management Agencies Association (BASMAA), 1999; and Using Site Design Techniques to Meet Development Standards for Stormwater Quality: A Companion Document to Start at the Source (“Using Site Design Techniques”) by BASMAA, 2003. 31. Utilities: All on-site utilities shall be installed underground per Section 21.18.140 of the Campbell Municipal Code for any new or remodeled buildings or additions. Applicant shall comply with all plan submittals, permitting, and fee requirements of the serving utility companies. Utility locations shall not cause damage to any existing street trees. Where there are utility conflicts due to established tree roots or where a new tree will be installed, alternate locations for utilities shall be explored. Include utility trench details where necessary. The proposed joint trench (JT) depicted in the Preliminary Utility Plans shall be relocated outside of the public right of way so as to avoid conflicts in the park strip area. Staff shall work with the applicant and local utility companies to discern connection requirements for adjacent properties as part of the requirement to underground utilities. 32. Water Meter(s) and Sewer Cleanout(s): Proposed water meter(s) and sewer cleanout(s) shall be relocated or installed on private property behind the public right-of-way line. 33. Utility Coordination Plan: Prior to issuance of building permits for the site, the applicant shall submit a utility coordination plan and schedule for approval by the City Engineer for installation and/or abandonment of all utilities. The plan shall clearly show the location and size of all existing utilities and the associated main lines; indicate which utilities and services are to remain; which utilities and services are to be Exhibit A - Conditions of Approval Tentative Subdivision Map (PLN2016-36) - 1323 Parsons Avenue Page 8 of 9 abandoned, and where new utilities and services will be installed. Joint trenches for new utilities shall be used whenever possible. 34. Pavement Restoration: Based on the utility coordination plan, the applicant shall prepare a pavement restoration plan for approval by the City Engineer prior to any utility installation or abandonment. Streets that have been reconstructed or overlaid within the previous five years will require boring and jacking for all new utility installations. Parsons Avenue has not been reconstructed or overlaid in the last 5 years. The pavement restoration plan shall indicate how the street pavement shall be restored following the installation or abandonment of all utilities necessary for the project. All pavement work shall extend to the most distant utility trench and pavement restoration shall encompass all utility trenches creating one rectangle. 35. Street Improvement Agreements / Plans / Encroachment Permit / Fees / Deposits: Prior to recordation of the Final Map, the applicant shall execute a street improvement agreement, cause plans for public street improvements to be prepared by a registered civil engineer, pay various encroachment permit fees and deposits, post security and provide insurance necessary to obtain an encroachment permit for construction of the standard public street improvements, as required by the City Engineer. The plans shall include the following, unless otherwise approved by the City Engineer: a. Show location of all existing utilities within the new and existing public right of way. b. Relocation of all existing utilities including utility boxes, covers, poles, etc. outside of sidewalk area. No utility boxes, covers, etc. will be allowed in the sidewalk area. c. Removal of existing driveway approach and necessary sidewalk, curb and gutter. d. Removal of existing street section to centerline or as required by the City Engineer. e. Installation of City approved street trees and irrigation at 30 feet on center. f. Installation of City standard curb, gutter, sidewalk and ADA compliant driveway approach. g. Installation of asphalt concrete overlay per street pavement restoration plan for utility installation and/or abandonment, as required by the City Engineer. h. Installation of traffic control, stripes and signs. i. Construction of conforms to existing public and private improvements, as necessary. j. Submit final plans in a digital format acceptable to the City. 36. Street Improvements Completed for Occupancy and Building Permit Final: Prior to allowing occupancy and/or final building permit signoff for any and/or all buildings, the applicant shall have the required street improvements and pavement restoration Exhibit A - Conditions of Approval Tentative Subdivision Map (PLN2016-36) - 1323 Parsons Avenue Page 9 of 9 installed and accepted by the City, and the design engineer shall submit as-built drawings to the City. 37. Utility Encroachment Permit: Separate encroachment permits for the installation of utilities to serve the development will be required (including water, sewer, gas, electric, etc.). Applicant shall apply for and pay all necessary fees for utility permits for sanitary sewer, gas, water, electric and all other utility work. 38. Additional Street Improvements: Should it be discovered after the approval process that new utility main lines, extra utility work or other work is required to service the development, and should those facilities or other work affect any public improvements, the City may add conditions to the development/project/permit, at the discretion of the City Engineer, to restore pavement or other public improvements to the satisfaction of the City. RESOLUTION NO. ______ BEING A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CAMPBELL APPROVING A PLANNED DEVELOPMENT PERMIT (PLN2016-34) FOR SITE CONFIGURATION RESULTING IN THE DEVELOPMENT OF FOUR UNITS, ARCHITECTURAL DESIGN, AND CREATION OF LOTS WHICH DO NOT HAVE FRONTAGE ON A PUBLIC STREET ON PROPERTY LOCATED AT 1323 PARSONS AVENUE. After notification and public hearing, as specified by law and after presentation by the Community Development Director, proponents and opponents, the hearing was closed. The City Council finds as follows with regard to the recommended approval of a Planned Development Permit (PLN2016-34): Environmental Finding 1. An Initial Study has been prepared for the project which provides documentation for the factual basis for concluding that a Mitigated Negative Declaration (PLN2016-37) may be adopted since no substantial evidence exists, in light of the whole record, that the project may have a significant effect on the environment as conditioned. Evidentiary Findings 2. The proposed project ("project") includes a Planned Development Permit (PLN2016- 34) for the approval of site configuration, architectural design and to create residential lots which do not have frontage on a public street, Tentative Subdivision Map (PLN2016-36) to create four developable single family lots and one commonly owned lot, Zoning Map Amendment (PLN2016-35) to change the zoning from R-1-6 (Single- Family Residential) to P-D (Planned Development), and Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of covered. 3. The project site is a 33,263 square-foot property located on the west side of Parsons Avenue, south of Camden Avenue, and north of Sharp Avenue. 4. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. 5. The lot is currently developed with one single-family residence that will be demolished as part of the proposed subdivision. 6. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. 7. The project site is zoned R-1-6 (Residential Single-Family) as shown on the Campbell Zoning Map and will be rezoned to P-D (Planned Development). 8. The project site is designated Low Density Residential (<6 Units / Gr. Acre) as shown on the Campbell General Plan Map. City Council Resolution PLN2016-34 – Approving a Planned Development Permit –1323 Parsons Avenue Page 2 of 4 9. The proposed residential land use, at a density of approximately 5 units/gr. acre, is consistent with the allowable land use and maximum density permitted by the Low Density Residential (< 6 units per gross acre) General Plan land use designation. 10. The proposed Tentative Subdivision Map may be approved concurrently, and subject to a Planned Development Permit, and Zoning Map Amendment. 11. The project would be consistent with the following General Plan policies and strategies: Policy LUT-3.1: Variety of Residential Densities: Provide land use categories for and maintenance of a variety of residential densities to offer existing and future residents of all income levels, age groups and special needs sufficient opportunities and choices for locating in Campbell. Strategy LUT-5.2a: Neighborhood Compatibility: Promote new residential development and substantial additions that are designed to maintain and support the existing character and development pattern of the surrounding neighborhood, especially in historic neighborhoods and neighborhoods with consistent design characteristics. Strategy LUT-9.3e: Building Materials: Encourage the use of long-lasting, high quality building materials on all buildings to ensure the long-term quality of the built environment. Strategy LUT-17.1b: Landscaping: Ensure that new developments provide new tree plantings, shrubs, greenery and other landscaping materials, and preserve existing trees and shrubs. 12. The project proposes 13 parking spaces (8 covered, 5 uncovered), where 12 parking spaces (10 covered, 2 uncovered) are required which is allowed with the approval of the associated Parking Modification Permit (PLN2016-68). 13. A draft Mitigation Monitoring and Reporting Program has been provided demonstrating the responsible party and phase of the project that each Mitigation Measure shall be carried out. 14. There are no responsible agencies or trustee agencies responsible for resources affected by the project. 15. On the basis of the Initial Study, and as supported by substantial evidence, the project will not have a significant effect on the environment due to the application of uniformly applicable development policies, and incorporation of project-specific mitigation measures agreed to by the project proponent, as specified by the draft Mitigated Negative Declaration. City Council Resolution PLN2016-34 – Approving a Planned Development Permit –1323 Parsons Avenue Page 3 of 4 16. The City of Campbell provided a Notice of Intent to adopt a Mitigated Negative Declaration to the public via the Campbell Express, the County Clerk, and on the City website. 17. The City of Campbell provided a 20-day public review period of the Mitigated Negative Declaration pursuant to the California Environmental Quality Act Guidelines. The 20- day public review period was from August 3, 2016 to August 23, 2016. 18. The mitigation measures identified in the Mitigated Negative Declaration are included as Conditions of Approval of the Planned Development Permit and/or Tentative Subdivision Map. Based upon the foregoing findings of fact, the City Council further finds and concludes that: 19. The proposed development will clearly result in a more desirable environment and use of the land than would be possible under any other zoning district classification. 20. The proposed development will be compatible with the General Plan of the City and will aid in the harmonious development of the immediate area. 21. The proposed development will not result in allowing more residential units than would be allowed by other residential zoning districts, which are consistent with the General Plan designation of the property. 22. The proposed development will not be detrimental to the health, safety or welfare of the neighborhood or the City as a whole. 23. There is a reasonable relationship and a rough proportionality between the Conditions of Approval and the impacts of the project. 24. There is a reasonable relationship between the use of the fees imposed upon the project and the type of development project. 25. No substantial evidence has been presented from which a reasonable argument could be made that shows that the project, as currently presented and subject to the required conditions of approval, will have a significant adverse impact on the environment. City Council Resolution PLN2016-34 – Approving a Planned Development Permit –1323 Parsons Avenue Page 4 of 4 THEREFORE, BE IT RESOLVED that the City Council approves a Planned Development Permit (PLN2016-34) for the Project located at 1323 Parsons Avenue, subject to the attached Conditions of Approval (attached Exhibit “A”). PASSED AND ADOPTED this _______day of ___________, 2016, by the following roll call vote: AYES: COUNCILMEMBERS: NOES: COUNCILMEMBERS: ABSENT: COUNCILMEMBERS: ABSTAIN: COUNCILMEMBERS: APPROVED: Jason T. Baker, Mayor ATTEST: Wendy Wood, City Clerk EXHIBIT A CONDITIONS OF APPROVAL Planned Development Permit (PLN2016-34) Where approval by the Director of Community Development, City Engineer, Public Works Director, City Attorney or Fire Department is required, that review shall be for compliance with all applicable conditions of approval, adopted policies and guidelines, ordinances, laws and regulations and accepted engineering practices for the item under review. Additionally, the applicant is hereby notified that he/she is required to comply with all applicable Codes or Ordinances of the City of Campbell and the State of California that pertain to this development and are not herein specified. COMMUNITY DEVELOPMENT DEPARTMENT Planning Division 1. Approved Project: Approval is granted for a Planned Development Permit (PLN2016- 34) approving site configuration, architectural design, and the creation of four residential lots/units which do not have frontage on a public street, in conjunction with and subject to a Zoning Map Amendment (PLN2016-34) to rezone the property from R-1-6 (Single-Family Residential) to P-D (Planned Development), Tentative Subdivision Map (PLN2016-36), and Parking Modification Permit (PLN2016-222) on property located at 1323 Parsons Avenue. The project shall substantially conform to the Revised Project Plans dated August 9, 2016 except as may be modified by the Conditions of Approval herein. 2. Planning Final Required: Planning Division clearance is required prior to Building Permit final. 3. Plan Revisions: Prior to Building Permit submittal, the project plans shall reflect the following changes: a. Conditions of Approval: The conditions of approval shall be stated in full in the construction plans. b. Fence/Wall: The applicant shall coordinate the construction of a new or reconstructed wooden fence or masonry wall that shall be between six and nine feet in height with enhanced landscaping (e.g. Italian cypress) placed in the landscape strip between the driveway and the offsite commercial uses to the east (i.e. Jiffy Lube). The final design/specifications of the wall shall incorporate recommendations of the project acoustical analysis. c. Barbeque: The proposed barbeque, on the common lot, shall be removed from the plans. d. Parking: Prior to occupancy, thirteen (eight covered and five uncovered) residential parking spaces shall be provided. Uncovered parking spaces shall be adequately striped in the locations shown on the Project Plans and incorporate wheel stops as well as signage to signify the total number and availability to guests of all units at all times. e. Trees: The project plans shall note reflect a minimum of two trees per lot (including two for the common lot located near the guest parking spaces). The tree species selected shall be a Crape Myrtle. Where trees are proposed for Exhibit A - Conditions of Approval PLN2016-34 – 1323 Parsons Avenue - Planned Development Permit Page 2 of 8 removal, the project plans will clearly note that the root stump shall be removed as well. The incorporation of these revisions shall be subject to the satisfaction and approval of the Director of Community Development. 4. Permit Expiration: The Planned Development Permit is valid for a period of two years from the date of final City Council approval. A building permit must be obtained within this two-year period or the Planned Development Permit shall be void. 5. Tract Map: The Planned Development Permit approval is contingent upon recordation of the Tract Map to divide the subject property. The Tract Map shall be recorded prior to the issuance of building or grading permits. 6. Equal Access: As codified within the project's CC&Rs, the Home Owners Association shall maintain equal access to all common facilities and amenities by all residents (renters and homeowners) of the project. 7. Contractor Contact Information Posting: The project site shall be posted with the name and contact number of the lead contractor in a location visible from the public street prior to the issuance of building permits. 8. Parking and Driveways: All parking and driveway areas shall be developed and maintained in compliance chapter 21.28 (Parking and Loading Ordinance) of the Campbell Municipal Code. 9. Indemnity: If determined necessary by the Community Development Director, the applicant shall enter into an agreement satisfactory to the City Attorney to indemnify and defend the City of Campbell, its officers, officials, employees, and agents from any and all actions, liabilities, losses, and torts, including attorney’s fees arising out of or connected unto any challenge to the decision of the City Council on this application. Such agreement shall be executed within the 30 days of the Community Development Director's decision to require it. 10. Planned Development Permit: The Planned Development Permit (PLN2016-34) is contingent upon approval of the Tentative Subdivision Map (PLN2016-36). A Tract Map may not be recorded if the Planned Development Permit expires or is revoked by the City Council. 11. CEQA Mitigation Measures: The following measures shall be implemented pursuant to the Mitigated Negative Declaration: Mitigation Measure AIR-1: The project applicant shall ensure that construction plans include the BAAQMD Best Management Practices for fugitive dust control. The following will be required for all construction activities within the project area. These measures will reduce fugitive dust emissions primarily during soil movement, Exhibit A - Conditions of Approval PLN2016-34 – 1323 Parsons Avenue - Planned Development Permit Page 3 of 8 grading and demolition activities, but also during vehicle and equipment movement on unpaved project sites: a. Use dust-proof chutes for loading construction debris onto trucks. b. Water or cover stockpiles of debris, soil, and other materials that can be blown by the wind. c. Cover all trucks hauling soil, sand, and other loose materials or require all trucks to maintain at least two feet of freeboard. d. Sweep daily (with water sweepers) all paved access roads, parking areas, and staging areas at the construction site. e. Sweep streets daily (with water sweepers) if visible soil material is carried onto adjacent public streets, as directed by the City Engineer. f. Enclose, cover, water twice daily or, or apply (non-toxic) soil stabilizers to exposed stockpiles (dirt, sand, etc.). g. Install erosion control measures to prevent runoff from the project site. Mitigation Measure CUL-1: If archaeological or paleontological resources are encountered during excavation or construction, construction personnel shall be instructed to immediately suspend all activity in the immediate vicinity of the suspected resources and the City and a licensed archeologist or paleontologist shall be contacted to evaluate the situation. A licensed archeologist or paleontologist shall be retained to inspect the discovery and make any necessary recommendations to evaluate the find under current CEQA guidelines prior to the submittal of a resource mitigation plan and monitoring program to the City for review and approval prior to the continuation of any on-site construction activity. Mitigation Measure GEO-1: The applicant shall comply with the recommendations in the Geotechnical Investigation, dated January 7, 2016 by Wayne L. Ting C.E. (No. C46276) of Wayne Ting & Associates Incorporated. Such recommendations shall be incorporated into the project’s final engineering design to minimize the damage from seismic shaking, unsuitable fill, and other geological deficiencies. The project shall use standard engineering techniques and conform to the requirements of the International Building Code to reduce the potential for seismic damage and risk to future occupants. Mitigation Measure HAZ-1: Prior to issuance of a demolition permit, a qualified contractor shall asses the property for presence of Lead-based paint (LBP) and Asbestos containing building materials (ACBM), and if present, prepare a plan, to the satisfaction of the Building Official, to properly manage and dispose of such materials. Mitigation Measure NOI-1: Mechanical ventilation (HVAC) shall be included in all residences constructed to allow occupants to close doors and windows as desired to achieve additional acoustic isolation. Further, the project building plans shall incorporate dual pane thermal windows and acoustically effective doors with a rated minimum Sound Transmission Class (STC) as recommended by the acoustical study. Exhibit A - Conditions of Approval PLN2016-34 – 1323 Parsons Avenue - Planned Development Permit Page 4 of 8 Mitigation Measure NOI-2: An acoustical study shall be prepared for the project which will study existing noise conditions, the project plans, and provide specific structural recommendations to comply with the noise exposure limits identified in the Campbell General Plan. The project building plans shall incorporate the recommendations as mitigation measures. 12. Pest Control: Prior to issuance of a demolition and/or building permit, the applicant shall be required to hire a pest control company to inspect the site for rodents and provide a report on the inspection to the City for review. If it has determined that rodents exist, a remediation plan shall be prepared by the pest control company and provided to the City for review and approval, and the remediation plan shall be implemented to rid the site of rodents prior to issuance of a demolition and/or building permit. 13. Sound Attenuation: The project shall comply with the City Residential Noise Standards (CMC 21.16.070.E). 14. Roof Vents: The applicant shall coordinate mechanical and plumbing plans to minimize the number of roof vents that are visible from the street frontage. The applicant shall provide the location of such vents on the building plan elevations and roof plans, to the satisfaction of the Community Development Director, prior to issuance of a building permit. 15. Utility Boxes and Back-Flow Preventers: The applicant shall submit a plan prior to installation of the underground PG&E utility (transformer) boxes and San Jose Water Company back-flow preventers, indicating the location of the boxes for approval by the Community Development Director. 16. Pad Certification: Following site grading and prior to preparation of individual building pad forms, the following improvements shall be certified by a licensed land surveyor and reviewed by the Community Development Director to determine consistency with the approved plan (grade, pad and drainage). 17. Residential Address Identification: The applicant shall submit a detail sheet showing uniform residential address identification material type and location on the building wall for review and approval by the Community Development prior to the issuance of Building Permits. In order to obtain approval, numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Additionally, number material and color is required to contrast with their background. 18. Property Maintenance: The property is to be maintained free of any combustible trash, debris, and weeds until the time that actual construction commences. Any vacant existing structures shall be secured, by having windows boarded up and doors sealed Exhibit A - Conditions of Approval PLN2016-34 – 1323 Parsons Avenue - Planned Development Permit Page 5 of 8 shut, or be demolished or removed from the property (California Fire Code, 2013 Edition). 19. Stormwater and Grading Requirements: The project shall comply with City stormwater and grading requirements (CMC Sec. 20.80.020, 21.16.100, and 14.02), as more specifically itemized in the Public Works Department Conditions of Approval for the Tentative Subdivision Map. 20. Construction Activity: The following standards shall apply to construction of the project: • Construction Hours (CMC 18.04.052): Construction activity shall be limited to the hours of eight a.m. and five p.m. daily, Monday through Friday. Saturday hours of construction shall be nine a.m. and four p.m. There shall be no construction activity on Sundays or National Holidays. • Construction Noise (CMC 18.04.052): No loud environmentally disruptive noise over fifty dbs., such as air compressors without mufflers, continuously running motors or generators, loud playing musical instruments or radios will be allowed during the authorized hours of construction, Monday through Saturday, where such noise may be a nuisance to adjacent residential neighbors. Such nuisances shall be discontinued. • Contractor Contact Information Posting: The project site shall be posted with the name and contact number of the lead contractor in a location visible from the public street prior to issuance of building permits. Building Division 21. Permits Required: A building permit application shall be required for the proposed new dwelling structures. The building permit shall include Electrical/Plumbing/Mechanical fees when such work is part of the permit. 22. Plan Preparation: This project requires plans prepared under the direction and oversight of a California licensed Engineer or Architect. Plans submitted for building permits shall be “wet stamped” and signed by the qualifying professional person. 23. Construction Plans: The conditions of Approval shall be stated in full on the cover sheet of construction plans submitted for building permit. 24. Size Of Plans: The minimum size of construction plans submitted for building permits shall be 24 in. X 36 in. 25. Soils Report: Two copies of a current soils report, prepared to the satisfaction of the Building Official, containing foundation and retaining wall design recommendations shall be submitted with the building permit application. This report shall be prepared by a licensed engineer specializing in soils mechanics. Exhibit A - Conditions of Approval PLN2016-34 – 1323 Parsons Avenue - Planned Development Permit Page 6 of 8 26. Site Plan: Application for building permit shall include a competent site plan that identifies property and proposed structures with dimensions and elevations as appropriate. Site plan shall also include site drainage details. Elevation bench marks shall be called out at all locations that are identified as “natural grade” and intended for use to determine the height of the proposed structure. 27. Foundation Inspections: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project building inspector upon foundation inspection. This certificate shall certify compliance with the recommendations as specified in the soils report and the building pad elevation and on-site retaining wall locations and elevations are prepared according to approved plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered civil engineer for the following items: a. pad elevation b. finish floor elevation (first floor) c. foundation corner locations 28. Special Inspections: When a special inspection is required by C.B.C. Chapter 17, the architect or engineer of record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the building permits, in accordance with C.B.C Chapter 1, Section 106. Please obtain City of Campbell, Special Inspection forms from the Building Inspection Division Counter. 29. Non-Point Source Pollution: The City of Campbell, standard Santa Clara Valley Non- point Source Pollution Control Program specification sheet shall be part of plan submittal. The specification sheet (size 24” X 36”) is available at the Building Division service counter. 30. Approvals Required: The project requires the following agency approval or consultation prior to issuance of the building permit: a. West Valley Sanitation District (378-2407) b. Santa Clara County Fire Department (378-4010) c. San Jose Water Company (408) 279-7900 (Customer Service) d. School District: i. Campbell Union School District (378-3405) ii. Campbell Union High School District (371-0960) iii. Moreland School District (379-1370) iv. Cambrian School District (377-2103) Note: To Determine your district, contact the offices identified above. Obtain the School District payment form from the City Building Division, after the Division has approved the building permit application. 31. P.G.& E.: Applicant is advised that Secondary Dwelling Units on Residential lots are not able to have separate electrical and gas service. Gas and Electric service must be provided from the services associated with the main residential structure. Exhibit A - Conditions of Approval PLN2016-34 – 1323 Parsons Avenue - Planned Development Permit Page 7 of 8 32. California Green Building Code: This project is subject to the mandatory requirements for new residential structures (Chapter 4) under the California Green Building Code, 2013 edition. Exhibit A - Conditions of Approval PLN2016-34 – 1323 Parsons Avenue - Planned Development Permit Page 8 of 8 33. Construction Fencing: This project shall be properly enclosed with construction fencing to prevent unauthorized access to the site during construction. The construction site shall be secured to prevent vandalism and/or theft during hours when no work is being done. All protected trees shall be fenced to prevent damage to root systems. 34. Build It Green: Applicant shall complete and submit a “Build it Green” inventory of the proposed new single family project prior to issuance of building permit. 35. Automatic Fire Sprinkler Systems: This project shall comply with Section R313 of the California Residential building Code 2013 edition, and be equipped with a complying Fire Sprinkler system. 36. Storm Water Requirements: Storm water run-off from impervious surface created by this permitted project shall be directed to vegetated areas on the project parcel. Storm water shall not drain onto neighboring parcels. RESOLUTION NO. ______ BEING A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF CAMPBELL APPROVING A PARKING MODIFICATION PERMIT (PLN2016-222) TO ALLOW UNCOVERED PARKING IN LIEU OF COVERED ON PROPERTY LOCATED AT 1323 PARSONS AVENUE. After notification and public hearing, as specified by law and after presentation by the Community Development Director, proponents and opponents, the hearing was closed. The City Council finds as follows with regard to File No. PLN2016-222: Environmental Finding 1. An Initial Study has been prepared for the project which provides documentation for the factual basis for concluding that a Mitigated Negative Declaration (PLN2016-37) may be adopted since no substantial evidence exists, in light of the whole record, that the project may have a significant effect on the environment as conditioned. Evidentiary Findings 2. The proposed project ("project") includes a Planned Development Permit (PLN2016- 34) for the approval of site configuration, architectural design and to create residential lots which do not have frontage on a public street, Tentative Subdivision Map (PLN2016-36) to create four developable single family lots and one commonly owned lot, Zoning Map Amendment (PLN2016-35) to change the zoning from R-1-6 (Single- Family Residential) to P-D (Planned Development), and Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of covered. 3. The project site is a 33,263 square-foot property located on the west side of Parsons Avenue, south of Camden Avenue, and north of Sharp Avenue. 4. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. 5. The lot is currently developed with one single-family residence that will be demolished as part of the proposed subdivision. 6. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. 7. The project site is zoned R-1-6 (Residential Single-Family) as shown on the Campbell Zoning Map and will be rezoned to P-D (Planned Development). City Council Resolution PLN2016-222 – Approving a Parking Modification Permit –1323 Parsons Avenue Page 2 of 4 8. The project site is designated Low Density Residential (<6 Units / Gr. Acre) as shown on the Campbell General Plan Map. 9. The proposed residential land use, at a density of approximately 5 units/gr. acre, is consistent with the allowable land use and maximum density permitted by the Low Density Residential (< 6 units per gross acre) General Plan land use designation. 10. The proposed Tentative Subdivision Map may be approved concurrently, and subject to a Planned Development Permit, and Zoning Map Amendment. 11. The project would be consistent with the following General Plan policies and strategies: Policy LUT-3.1: Variety of Residential Densities: Provide land use categories for and maintenance of a variety of residential densities to offer existing and future residents of all income levels, age groups and special needs sufficient opportunities and choices for locating in Campbell. Strategy LUT-5.2a: Neighborhood Compatibility: Promote new residential development and substantial additions that are designed to maintain and support the existing character and development pattern of the surrounding neighborhood, especially in historic neighborhoods and neighborhoods with consistent design characteristics. Strategy LUT-9.3e: Building Materials: Encourage the use of long-lasting, high quality building materials on all buildings to ensure the long- term quality of the built environment. Strategy LUT-17.1b: Landscaping: Ensure that new developments provide new tree plantings, shrubs, greenery and other landscaping materials, and preserve existing trees and shrubs. 12. The project proposes 13 parking spaces (8 covered, 5 uncovered), where 12 parking spaces (10 covered, 2 uncovered) are required which is allowed with the approval of the associated Parking Modification Permit (PLN2016-68). 13. A draft Mitigation Monitoring and Reporting Program has been provided demonstrating the responsible party and phase of the project that each Mitigation Measure shall be carried out. 14. There are no responsible agencies or trustee agencies responsible for resources affected by the project. 15. On the basis of the Initial Study, and as supported by substantial evidence, the project will not have a significant effect on the environment due to the application of City Council Resolution PLN2016-222 – Approving a Parking Modification Permit –1323 Parsons Avenue Page 3 of 4 uniformly applicable development policies, and incorporation of project-specific mitigation measures agreed to by the project proponent, as specified by the draft Mitigated Negative Declaration. 16. The City of Campbell provided a Notice of Intent to adopt a Mitigated Negative Declaration to the public via the Campbell Express, the County Clerk, and on the City website. 17. The City of Campbell provided a 20-day public review period of the Mitigated Negative Declaration pursuant to the California Environmental Quality Act Guidelines. The 20-day public review period was from August 3, 2016 to August 23, 2016. 18. The mitigation measures identified in the Mitigated Negative Declaration are included as Conditions of Approval of the Planned Development Permit and/or Tentative Subdivision Map. Based upon the foregoing findings of fact, the City Council further finds and concludes that: 19. Due to the unique nature and circumstances of the project, or special development features, the anticipated number (type) of parking spaces necessary to serve the use or structure is less than that required by the applicable off-street parking standards, and would be satisfied by the proposed number (type) of parking spaces. 20. Conditions of approval have been incorporated into the project to ensure the long-term adequacy of the provided off-street parking. 21. Approval of the parking modification permit will further the purpose of Campbell Municipal Code Chapter 21.28 (Parking and Loading). 22. There is a reasonable relationship and a rough proportionality between the Conditions of Approval and the impacts of the project. 23. No substantial evidence has been presented from which a reasonable argument could be made that shows that the project, as currently presented and subject to the required conditions of approval, will have a significant adverse impact on the environment. THEREFORE, BE IT RESOLVED that the City Council approves a Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of covered, subject to the attached recommended Conditions of Approval (attached Exhibit A). PASSED AND ADOPTED this _______day of ___________, 2016, by the following roll call vote: AYES: COUNCILMEMBERS: NOES: COUNCILMEMBERS: City Council Resolution PLN2016-222 – Approving a Parking Modification Permit –1323 Parsons Avenue Page 4 of 4 ABSENT: COUNCILMEMBERS: ABSTAIN: COUNCILMEMBERS: APPROVED: Jason T. Baker, Mayor ATTEST: Wendy Wood, City Clerk EXHIBIT A CONDITIONS OF APPROVAL Parking Modification Permit (PLN2016-222) Where approval by the Director of Community Development, City Engineer, Public Works Director, City Attorney or Fire Department is required, that review shall be for compliance with all applicable conditions of approval, adopted policies and guidelines, ordinances, laws and regulations and accepted engineering practices for the item under review. Additionally, the applicant is hereby notified that he/she is required to comply with all applicable Codes or Ordinances of the City of Campbell and the State of California that pertain to this development and are not herein specified. COMMUNITY DEVELOPMENT DEPARTMENT Planning Division 1. Approved Project: Approval is granted for a Parking Modification Permit (PLN2016- 222) to allow uncovered parking in lieu of covered, in conjunction with and subject to a Planned Development Permit (PLN2016-34) approving site configuration, architectural design, and the creation of four residential lots/units which do not have frontage on a public street, in conjunction with and subject to a Zoning Map Amendment (PLN2016- 34) to rezone the property from R-1-6 (Single-Family Residential) to P-D (Planned Development), Tentative Subdivision Map (PLN2016-36), and Parking Modification Permit (PLN2016-222) on property located at 1323 Parsons Avenue. The project shall substantially conform to the Revised Project Plans and Tentative Subdivision Map dated August 9, 2016 except as may be modified by the Conditions of Approval herein. 2. Planning Final Required: Planning Division clearance is required prior to Building Permit final. 3. Approval Expiration: The Parking Modification Permit approval is valid for a period of two years from the date of final City Council approval unless an extension is granted prior to the expiration date. A building permit must be obtained within this two-year period or the Parking Modification Permit shall be void. 4. Parking: Prior to occupancy, thirteen (eight covered and five uncovered) residential parking spaces shall be provided. Uncovered parking spaces shall be adequately striped in the locations shown on the Project Plans and incorporate wheel stops as well as signage to signify the total number and availability to guests of all units at all times to the satisfaction of the Director of Community Development. Attachment #6 Location Map Project Address: 1323 Parsons Avenue, Campbell CA 95008 PRELIMINARY IMPROVEMENT PLANSFIVE LOT SUBDIVISION1323 PARSONS AVE., CAMPBELL, CALIFORNIAAPN: 414-37-0081323 PARSONS AVE., CAMPBELL, CALIFORNIAPRELIMINARY IMPROVEMENT PLANSFIVE LOT SUBDIVISIONCOVER SHEET/DETALS / NOTESAPN: 414-37-008SECTION Z-ZZSECTION W-WWPLANWZXPLANYXYSECTION Y-YSECTION X-X GRAPHIC SCALE1"=10'APN: 414-37-0081323 PARSONS AVE., CAMPBELL, CALIFORNIAPRELIMINARY IMPROVEMENT PLANSFIVE LOT SUBDIVISIONPRELIMINARY GRADING AND DRAINAGE PLAN GRAPHIC SCALE1"=10'APN: 414-37-0081323 PARSONS AVE., CAMPBELL, CALIFORNIAPRELIMINARY IMPROVEMENT PLANSFIVE LOT SUBDIVISION PRELIMINARY UTILITY PLAN11 GRAPHIC SCALE1"=10'APN: 414-37-0081323 PARSONS AVE., CAMPBELL, CALIFORNIAPRELIMINARY IMPROVEMENT PLANSFIVE LOT SUBDIVISIONPRELIMINARY STREET FRONTAGE IMPROVEMENT PLAN GRAPHIC SCALE1"=10'APN: 414-37-0081323 PARSONS AVE., CAMPBELL, CALIFORNIAPRELIMINARY IMPROVEMENT PLANSFIVE LOT SUBDIVISIONSTORMWATER CONTROL PLAN/ MEASURESCompliance with NPDES Permit Provision C.3:1Source Control Measures:Stormwater Treatment Measures:3Site Design Measures:2CONCRETE PAVEMENT MAINTENANCE : APN: 414-37-0081323 PARSONS AVE., CAMPBELL, CALIFORNIATENTATIVE MAPFIVE LOT SUBDIVISIONTENTATIVE MAPLEGEND AND ABBREVIATIONSGENERAL NOTESFIVE (5) LOT SUBDIVISIONLOT AREA TABLE CITY OF CAMPBELL Community Development Department 70 North First Street • Campbell, CA 95008-1423 • TEL (408) 866-2140 • FAX (408) 866-5140 • E-MAIL planning@cityofcampbell.com DRAFT MITIGATED NEGATIVE DECLARATION The Community Development Director has reviewed the proposed project described below to determine whether it could have a significant effect on the environment as a result of the project completion. “Significant effect on the environment” means a substantial, or potentially substantial, adverse change in any of the physical conditions within the area affected by the project including land, air, water, minerals, flora, fauna, ambient noise, and objects of historic or aesthetic significance. Project Title: 1323 Parsons Avenue Subdivision File Number(s): Planned Development Permit (PLN2016-34) | Tentative Subdivision Map (PLN2016-36) | Zoning Map Amendment (PLN2016-35) | CEQA Review (PLN2016-37) | Parking Modification Permit (PLN2016-222) Project Address: 1323 Parsons Avenue, Campbell CA 95008 Project Sponsor: Omid Shakeri, The Ridgecrest Group 2383 Joseph Avenue, Campbell, CA 95008 Existing Zoning: R-1-6 (Single-Family Residential) Proposed Zoning: P-D (Planned Development) General Plan Low-Medium Density Residential (6-13 units/gr. acre) Lead Agency: City of Campbell, Community Development Department 70 N. First Street, Campbell, CA 95008 Contact Person: Stephen Rose, Associate Planner (408) 866-2142 | stephenr@cityofcampbell.com Date Posted: August 3, 2016 Other public agencies whose approval is required: None Surrounding Land Uses / General Plan / Zoning: North: Jiffy Lube & Convalescent Care / Professional Office / P-O (Professional Office) South: Single-Family Residential / Low Den. Res. / R-1-6 (Single-Family Residential) East: Head to Toe Salon & H&R Block / Professional Office / P-O (Professional Office) West: Single-Family Residential / Low Den. Res. / R-1-6 (Single-Family Residential) Mitigated Negative Declaration ~ 1323 Parsons Avenue Page 2 of 3 Project Description: The applicant is seeking approval of a Planned Development Permit to allow the construction of four new two-story single-family residences, a Zone Change to allow a zone district change from R-1-6 (Single Family Residential) to P-D (Planned Development), Vesting Tentative Subdivision Map to allow the creation of five lots (four developable) from a single parcel and Parking Exception Permit to allow uncovered parking spaces to be provided in lieu of required covered parking. Finding: The Community Development Director finds that the project described above will not have a significant effect on the environment in that the attached Initial Study identifies one or more potentially significant effects on the environment for which the project proponent, before public release of this draft Mitigated Negative Declaration, has made or agrees to make project revisions that clearly mitigate the effects to a less than significant level. Mitigation Measures Included in the Project to Reduce Potentially Significant Environmental Effects to a Less Than Significant Level: Mitigation Measure AIR-1: The project applicant shall ensure that construction plans include the BAAQMD Best Management Practices for fugitive dust control. The following will be required for all construction activities within the project area. These measures will reduce fugitive dust emissions primarily during soil movement, grading and demolition activities, but also during vehicle and equipment movement on unpaved project sites: a. Use dust-proof chutes for loading construction debris onto trucks. b. Water or cover stockpiles of debris, soil, and other materials that can be blown by the wind. c. Cover all trucks hauling soil, sand, and other loose materials or require all trucks to maintain at least two feet of freeboard. d. Sweep daily (with water sweepers) all paved access roads, parking areas, and staging areas at the construction site. e. Sweep streets daily (with water sweepers) if visible soil material is carried onto adjacent public streets, as directed by the City Engineer. f. Enclose, cover, water twice daily or, or apply (non-toxic) soil stabilizers to exposed stockpiles (dirt, sand, etc.). g. Install erosion control measures to prevent runoff from the project site. Mitigation Measure CUL-1: If archaeological or paleontological resources are encountered during excavation or construction, construction personnel shall be instructed to immediately suspend all activity in the immediate vicinity of the suspected resources and the City and a licensed archeologist or paleontologist shall be contacted to evaluate the situation. A licensed archeologist or paleontologist shall be retained to inspect the discovery and make any necessary recommendations to evaluate the find under current CEQA guidelines prior to the submittal of a resource mitigation plan and monitoring program to the City for review and approval prior to the continuation of any on-site construction activity. Mitigation Measure GEO-1: The applicant shall comply with the recommendations (Pages 12 through 14) in the Soil and Foundation Investigation of Proposed 4 Single Family Residences, dated April 29, 2016. Such recommendations shall be incorporated into the project’s final engineering design to minimize the damage from seismic shaking, unsuitable fill, and other geological deficiencies. The project shall use standard engineering techniques Mitigated Negative Declaration ~ 1323 Parsons Avenue Page 3 of 3 and conform to the requirements of the International Building Code to reduce the potential for seismic damage and risk to future occupants. Mitigation Measure HAZ-1: Prior to issuance of a demolition permit, a qualified contractor shall asses the property for presence of Lead-based paint (LBP) and Asbestos containing building materials (ACBM), and if present, prepare a plan, to the satisfaction of the Building Official, to properly manage and dispose of such materials. Mitigation Measure NOI-1: Mechanical ventilation (HVAC) shall be included in all residences constructed to allow occupants to close doors and windows as desired to achieve additional acoustic isolation. Further, the project building plans shall incorporate dual pane thermal windows and acoustically effective doors with a rated minimum Sound Transmission Class (STC) as recommended by the acoustical study. Mitigation Measure NOI-2: An acoustical study shall be prepared for the project which will study existing noise conditions, the project plans, and provide specific structural recommendations to comply with the noise exposure limits identified in the Campbell General Plan. The project building plans shall incorporate the recommendations as mitigation measures. PUBLIC REVIEW PERIOD Any person may file a written protest of the draft Mitigated Negative Declaration before 5:00 p.m. on August 23, 2016. Such protest must be filed at the Community Development Department, City Hall, 70 North First Street, Campbell, California. The written protest should make a "fair argument" that the project will have one or more significant effects on the environment based on substantial evidence. July 29, 2016 Signature Date Stephen Rose, Associate Planner City of Campbell Printed Name Agency Encl: Initial Study Mitigation Monitoring and Reporting Program INITIAL STUDY 1323 Parsons Avenue Subdivision An environmental evaluation prepared in compliance with the California Environmental Quality Act Prepared by Stephen Rose Associate Planner City of Campbell Community Development Department Planning Division 70 N. First Street Campbell, CA 95008 Public Review Period August 3, 2016 – August 23, 2016 Project Overview Page No. 2 I. PROJECT OVERVIEW Project Title: 1323 Parsons Avenue Subdivision File Number(s): Planned Development Permit (PLN2016-34) Zoning Map Amendment (PLN2016-35) Tentative Subdivision Map (PLN2016-36) CEQA Review (PLN2016-37) Parking Modification Permit (PLN2016-222) Project Address: 1323 Parsons Avenue, Campbell CA 95008 Project Sponsor: Omid Shakeri, The Ridgecrest Group 2383 Joseph Avenue, Campbell CA 95008 (408) 666-6556 Existing Zoning: R-1-6 (Single-Family Residential) Proposed Zoning: P-D (Planned Development) General Plan Low-Medium Density Residential (6-13 units/gr. acre) Lead Agency: City of Campbell, Community Development Department 70 N. First Street, Campbell, CA 95008 Contact Person: Stephen Rose, Associate Planner (408) 866-2142 | stephenr@cityofcampbell.com Date Posted: August 3, 2016 Project Location and Surrounding Land Use: The project site is a 33,263 square-foot property located on the west side of Parsons Avenue, south of Camden Avenue, and north of Sharp Avenue in the R-1-6 (Single-Family Residential) Zoning District. The site is currently developed with a 1,615 sq. ft. single-story single-family residence and 480 sq. ft. garage. Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. Project Description: The applicant is seeking approval of a Planned Development Permit to allow the construction of four new two-story single-family residences, a Zone Change to allow a zone district change from R-1-6 (Single Family Residential) to P-D (Planned Development), Vesting Tentative Subdivision Map to allow the creation of five lots (four developable) from a single parcel and Parking Exception Permit to allow uncovered parking spaces to be provided in lieu of required covered parking. Project Overview Page No. 3 Project Data Gross Lot Area: 34,766 square feet (including 25 foot street half-width) Net Lot Area: 33,263 square feet (32,963 sq. ft. after 300 sq. ft. dedication) Building Height: 25 feet, 4-inches Floor Area Ratio (FAR): 37.2% Building (Lot) Coverage: 23% Parking Spaces: 13 (8 covered; 5 uncovered) Proposed Density: 5.1 units/gr. acre (4 units / 0.775 gross acres) Maximum Density Allowed: 6 units/gr. acre File Number(s): Planned Development Permit (PLN2016-34) Zoning Map Amendment (PLN2016-35) Tentative Subdivision Map (PLN2016-36) CEQA Review (PLN2016-37) Parking Modification Permit (PLN2016-222) Project Entitlements: Required land use entitlements for the proposed project include a Planned Development Permit (PLN2016-34) for the approval of site configuration, architectural design and to create lots which do not have frontage on a public street, Tentative Subdivision Map (PLN2015-36) to create four single family lots and one commonly owned lot, Zoning Map Amendment (PLN2016-35) to change the zoning from R-1-6 (Single-Family Residential) to P-D (Planned Development), and Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of required covered parking. Other public agencies whose approval is required: None Project Exhibits – Location Map Page No. 4 Project Location Figure 1: Regional Setting Figure 2: Project Site Project Address: 1323 Parsons Avenue, Campbell CA 95008 Project Exhibits – Preliminary Site Plan Page No. 5 Existing Site Configuration Project Overview Page No. 6 Preliminary Vesting Tentative Subdivision Map Project Overview Page No. 7 Preliminary Site Plan Project Exhibits – Preliminary Grading and Drainage Plan Page No. 8 Preliminary Grading and Drainage Plan Project Exhibits – Preliminary Stormwater Treatment Plan Page No. 9 Preliminary Stormwater Treatment Plan Project Exhibits – Preliminary Landscaping Plan Page No. 10 Preliminary Landscaping Plan Environmental Impact Evaluation – Overview Page No. 11 II. ENVIRONMENTAL IMPACT EVALUATION: The following evaluation has been prepared to determine if the proposed project may result in a “significant impact” on the environment. For the purposes of this study, a significant impact means a substantial or potentially substantial change in the physical environment. The following terms used in the evaluation are defined as specified below: "Potentially Significant Impact" means that there is either substantial evidence that an effect may be significant or, due to lack of existing information, may have potential to be a significant effect. "Less than Significant With Mitigation Incorporated" means the incorporation of one or more mitigation measures can reduce the effect from potentially significant to a less than significant level. "Less Than Significant Impact" means that there is sufficient evidence available to determine that the effect is less than significant and no mitigation is necessary to reduce the impact to a lesser level. "No Impact" means that the effect does not apply to the proposed project, or clearly will not impact nor be impacted by the project. A description of the proposed mitigation measures and the factual data or evidence used to reach conclusions regarding impact significance follows each section. The environmental factors checked below would be potentially affected by this project, involving at least one impact that is a "Less Than Significant with Mitigation Incorporation" as indicated by the checklist on the following pages. The impacts of the project, as well as a recommended mitigation measures, are summarized in Section III: Recommendation and Determination. (1) Aesthetics (2) Agriculture Resources (3) Air Quality (Page 12) (Page 13) (Page 14) (4) Biological Resources (5) Cultural Resources (6) Geology/Soils (Page 19) (Page 20) (Page 21) (7) Greenhouse Gas Emissions (8) Hazards & Hazardous (9) Hydrology/Water (Page 23) Material (Page 21) Quality (Page 26) (10) Land Use/Planning (11) Mineral Resources (12) Noise (Page 28) (Page 29) (Page 30) (13) Population/Housing (14) Public Services (15) Recreation (Page 32) (Page 33) (Page 34) (16) Transportation/Traffic (17) Utilities/Service System (18) Mandatory Findings (Page 35) (Page 37) of Significance (Page 38) Environmental Impact Evaluation – Aesthetics Page No. 12 1. AESTHETICS Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Have a substantial adverse effect on a scenic vista? (b) Substantially damage scenic resources, including, but not limited to, trees, rock outcroppings, and historic buildings within a state scenic highway? (c) Substantially degrade the existing visual character or quality of the site and its surroundings? (d) Create a new source of substantial light or glare which would adversely affect day or nighttime views in the area? Discussion: (a to c): The project will alter the existing visual character of the site and its surroundings through demolition of existing structures and eventual development of a four-unit planned residential development. However, since the project site, nor any area, roadway or view-corridor in vicinity of the project site, is a recognized scenic vista or scenic resource, these activities will not result in an adverse environmental affect. Further, the project is subject to various policies and strategies of the Campbell General Plan and the Zoning Ordinance, intended to facilitate development that improves the visual character of the community through good design and site planning through an iterative design review and approval process which takes into account public input. (d): Currently, the project site has very limited lighting associated with the existing single-family residence. New site lighting is anticipated to include down-lit fixtures for new residences and lighting fixtures along the new public pathway. As all new lighting is subject to the City’s Lighting Design Standards (CMC Sec. 21.18.090)—which requires lighting to be designed and installed so that light rays are not emitted across property lines—the project would not result in new sources of substantial light or glare. Mitigation Measures(s): None Required. Environmental Impact Evaluation – Agricultural Resources Page No. 13 2. AGRICULTURAL RESOURCES Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Convert Prime Farmland, Unique Farmland, or Farmland of Statewide Importance (Farmland), as shown on the maps prepared pursuant to the Farmland Mapping and Monitoring Program of the California Resources Agency, to non-agricultural use? (b) Conflict with existing zoning for agricultural use, or a Williamson Act contract? (c) Involve other changes in the existing environment which, due to their location or nature, could result in conversion of Farmland, to non-agricultural use? Discussion: (a to c): The project site had historically been used for agricultural production, but is no longer used for, nor zoned for farmland or other agricultural or horticultural purpose. Neither the project site nor surrounding properties contain farmland or support agricultural activity that could be impacted by the project. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Air Quality Page No. 14 3. AIR QUALITY Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Conflict with or obstruct implementation of the applicable air quality plan? (b) Violate any air quality standard or contribute substantially to an existing or projected air quality violation? (c) Result in a cumulatively considerable net increase of any criteria pollutant for which the project region is non-attainment under an applicable federal or state ambient air quality standard (including releasing emissions which exceed quantitative thresholds for ozone precursors)? (d) Expose sensitive receptors to substantial concentrations of toxic air contaminants (TAC)? (e) Create objectionable odors affecting a substantial number of people? Portions of the following is excerpted from the 'Air Quality Report, prepared by The Cohen Group for this project, and has been expanded upon by staff for content, and edited for brevity and clarity. The complete document, including tables and figures, is included as Attachment 3. Discussion: (a to c): The City of Campbell is located within the southern region of the San Francisco Bay Area air basin. The California Air Resources Board coordinates and oversees both state and federal air quality control programs in California. The management of air quality in the basin is the responsibility of the Bay Area Air Quality Management District (BAAQMD). Specifically, the BAAQMD is responsible for monitoring ambient air pollutant levels throughout the basin, and developing and implementing attainment strategies to ensure that future emissions will be within Federal and State standards. The Bay Area Air Basin is currently classified as a “non-attainment” area for the state ozone standard, meaning that the level of ozone during a one-hour period exceeds the standard of 0.09 parts per million (ppm) on more than one day per year, excluding those occasions when a violation was caused by an exceptional event. For particulate matter less than 10 micrometers in diameter (PM10), the Bay Area Air Basin is currently designated as a “non-attainment” area for the state standard. All other pollutants are designated as “attainment” or “unclassified” for federal standards and as an “attainment” area for the state standard. The BAAQMD has established thresholds for determining whether a given project has the potential for a significant impact upon air quality. If a project exceeds the threshold(s), detailed air quality analyses are typically required, as well as review by BAAQMD staff. If a project does not exceed the thresholds, then it is assumed to have a less than significant impact upon air quality, unless there are special circumstances. For single-family residential developments, the BAAQMD has established 325- and 114- unit thresholds for operational- and construction-related air pollutants, respectively. As the project would result in creation of four developable residential parcels, it is below the minimum thresholds for air quality analysis and therefore is in compliance with the implementation of the applicable air quality plan. Per the BAAQMD, such a determination is subject to the project incorporating Best Management Practices (BMPs) in demolition and construction, as is required by City ordinances and reiterated through project specific conditions of approval and Mitigation Measure AIR-1. Environmental Impact Evaluation – Air Quality Page No. 15 Construction activities associated with the proposed project are expected to occur from August 2016 to May 2017. Excavation will be conducted over approximately one month with construction beginning shortly thereafter. Approximately 12-18 inches of soil will be excavated over the 32,200 square foot site and likely reused on site. Construction of the 4 residences including pouring of concrete foundations will occur shortly after excavation. Minimal diesel powered equipment will be used during the grading and underground work (electrical, plumbing, landscaping) the use of a single backhoe, sheeps foot compactor, excavator and bobcat excavator. Because of the construction time frame, overlapping of building phases, and the normal day-to-day variability in construction activities, the consultant did not find it possible to quantify the daily emissions associated with each phase of the proposed construction activities. Project construction would potentially only generate short-term emissions of air pollutants. The emissions generated from the construction activities include: • Dust (including PM10 and PM2.5) primarily form "fugitive" emission sources such as material handling and travel on unpaved surfaces; and • Construction emissions of criteria air pollutants (Nitrous oxides, Carbon monoxide, PM10, and PM2.5) primarily from operation of construction equipment as referenced above (primarily diesel- operated). It is anticipated that due to the small scale of the project, all construction-related emissions would be below the BAAQMD significance threshold levels. However, the construction contractor will reduce construction related air pollutant emissions by implementing basic fugitive dust control and exhaust emission measures including: • During active excavation all exposed surfaces will be watered at least one time per day. • All haul trucks transporting soil or other loose material shall be covered. • Idling times on equipment will be minimized by either shutting equipment off when not in use or reducing the maximum idling time to 5 minutes (as required by the California airborne taxies control measured Title 13, Section 2485 of California Code of Regulations). • Construction equipment will be maintained and properly tuned in accordance with manufacturer's specifications. As follows is the estimated short-term construction emissions that may be associated with the proposed project and comparisons of those emissions to the BAAQMD's significance thresholds for construction emission. The CalEEMod (California Emissions Estimator Model, Version 2013.2.2) was used to estimate construction-related emissions. Due to the small scale of this project, defaults for Santa Clara County were used. Therefore, it is anticipated that the model provides "worst case" emissions. Environmental Impact Evaluation – Air Quality Page No. 16 (d): The BAAQMD defines sensitive receptors as facilities where sensitive receptor population groups (e.g., children, the elderly, the acutely ill and the chronically ill) are likely to be located. These land uses can include residences, hospitals, schools, child-care centers, retirement centers, convalescent homes, and medical clinics. The closest off-site sensitive receptors include the Camden Convalescent Hospital (1131 Camden Avenue, Campbell) and Farnham Elementary School (15711 Woodard Road, San Jose). Air pollutant emissions are generated by stationary and mobile sources. Stationary sources include point sources and area sources. Point sources are usually subject to a permit to operate from the BAAQMD and occur at specific identified locations and are usually associated with manufacturing and industry. Area sources are widely distributed and typically produce small emissions and they do not require permits to operate from the BAAQMD. According to BAAQMD CEQA Air Quality Guidelines and Air Toxics New Source Review Program Health Risk Screening Analysis Guidelines, health effects form carcinogenic air toxics are usually described in terms of individual cancer risk. Individual cancer risk is the likelihood that a person exposed to concentrations of TACs over a 70-year lifetime will contract cancer. Environmental Impact Evaluation – Air Quality Page No. 17 The following shows the cumulative cancer risk index and PM2.5 impacting the proposed residences from BAAQMD permitted stationary sources and major roadways within 1,000 feet of the proposed project. For the purposes of the calculation the consultant used a distance of 745 feet from Highway 17 at Camden Avenue to proposed residents assuming 149,000 average daily vehicle traffic (based on BAAQMD data). Calculations are derived from Bay Area Air Quality Management District's Roadway Screening Analysis Calculator which provides screening level PM2.5 annual average concentrations and the cancer risk. This modeling guideline is based on standard procedures developed by the California Office of Environmental Health Hazard Assessment (OEHHA) for toxicity values and age sensitivity, and are consistent with the most current risk assessment methodology and toxicity factors used in the District's Regulation 2, Rule 5: New Source Review of Toxic Air Contaminant. Calculations are based on the assumption that residents are experiencing outdoor concentrations for the entire exposure period. The cumulative cancer risk is well below the BAAQMD cumulative cancer threshold risk of 100 per million for new residential receptors. Thus the proposed project would be a less than significant health impact on proposed receptors. No known BAAQMD permitted stationary emission sources other than possible automotive service facilities were determined within ¼ mile of the proposed residences and should provide no significant sources of toxic air contaminants to the proposed residences. According to the California Air Resources Board, most PM2.5 is derived from combustion, such as use of gasoline and diesel fuels by motor vehicles, burning of natural gas to generate electricity, and wood burning. PM2.5 is the size of ambient particulate matter air pollution most associated with adverse health effects of the air pollutants that have ambient air quality standards. These health effects include cardiovascular and respiratory hospitalizations, and premature death. As a California statewide average, DPM (as diesel particulate matter, including gasoline, etc.) comprises about 8% of PM2.5 in outdoor air, although DPM levels vary regionally due to the non-uniform distribution of sources throughout the state. Adverse chronic health impacts unrelated to cancer are measured against a hazard impact index which is defined as the particulate matter impact to a reference exposure levels as determined by OEHHA. The chronic reference exposure level for particulate matter (as diesel particulate matter) is 5ug/m³. Therefore assuming the PM2.5 is 0.116 ug/m³, compared to the OEHHA reference exposure level the hazard impact index is 0.23. Thus, the health hazard impact from Highway 17 to the proposed residences is less than the BAAQMD threshold of 1 and therefore the proposed project would be a less than significant health impact on proposed receptors. Environmental Impact Evaluation – Air Quality Page No. 18 (e): No element of construction or normal activities associated with single-family residences would result in creation of objectionable odors. Mitigation Measure(s): AIR – 1: The project applicant shall ensure that construction plans include the BAAQMD Best Management Practices for fugitive dust control. The following will be required for all construction activities within the project area. These measures will reduce fugitive dust emissions primarily during soil movement, grading and demolition activities, but also during vehicle and equipment movement on unpaved project sites: a. Use dust-proof chutes for loading construction debris onto trucks. b. Water or cover stockpiles of debris, soil, and other materials that can be blown by the wind. c. Cover all trucks hauling soil, sand, and other loose materials or require all trucks to maintain at least two feet of freeboard. d. Sweep daily (with water sweepers) all paved access roads, parking areas, and staging areas at the construction site. e. Sweep streets daily (with water sweepers) if visible soil material is carried onto adjacent public streets, as directed by the City Engineer. f. Enclose, cover, water twice daily or, or apply (non-toxic) soil stabilizers to exposed stockpiles (dirt, sand, etc.). g. Install erosion control measures to prevent runoff from the project site. Environmental Impact Evaluation – Biological Resource Page No. 19 4. BIOLOGICAL RESOURCES Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Have a substantial adverse effect, either directly or through habitat modifications, on any species identified as a candidate, sensitive, or special status species in local or regional plans, policies, or regulations, or by the California Department of Fish and Game or U.S. Fish and Wildlife Service? (b) Have a substantial adverse effect on any riparian habitat or other sensitive natural community identified in local or regional plans, policies, regulations or by the California Department of Fish and Game or U.S. Fish and Wildlife Service? (c) Have a substantial adverse effect on federally protected wetlands as defined by Section 404 of the Clean Water Act (including, but not limited to, marsh, vernal pool, coastal, etc.) through direct removal, filling, hydrological interruption, or other means? (d) Interfere substantially with the movement of any native resident or migratory fish or wildlife species or with established native resident or migratory wildlife corridors, or impede the use of native wildlife nursery sites? (e) Conflict with any local policies or ordinances protecting biological resources, such as a tree preservation policy or ordinance? (f) Conflict with the provisions of an adopted Habitat Conservation Plan, Natural Community Conservation Plan, or other approved local, regional, or state habitat conservation plan? Discussion: (a to d): According to the California Natural Diversity Database and the City’s General Plan, no species identified as a candidate, sensitive or special status species, or habitat for such species are known to occupy the project site. (e) The applicant shall be required to provide a detailed landscape and irrigation plan which conforms to the City’s Water Efficient Landscaping Standards (WELS). The landscaping will be designed to minimize irrigation and runoff, and promote surface infiltration where appropriate. While the applicant is proposing to remove several trees, the trees proposed for removal are not considered protected by virtue of their species and size pursuant to the City’s Tree Protection requirements (CMC Sec. 21.32) and as such, no replacement trees or other mitigation measures are required to comply with local policies or ordinances. Therefore, the project will incur a less than significant impact. (f): No adopted Habitat Conservation Plan, Natural Community Conservation Plan or approved local, regional or state habitat conservation plans apply to the project or the project site. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Cultural Resource Page No. 20 5. CULTURAL RESOURCES Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Cause a substantial adverse change in the significance of a historical resource as defined in §15064.5? (b) Cause a substantial adverse change in the significance of an archaeological resource pursuant to §15064.5? (c) Directly or indirectly destroy a unique paleontological resource or site or unique geologic feature? (d) Disturb any human remains, including those interred outside of formal cemeteries? Discussion: (a): The Phase I Environmental Site Assessment prepared for the project identified the historic of use of the property as agricultural production (orchards) by the 1930’s and remained agricultural into the 1950’s. The house on the subject property was constructed circa 1950 and the original sewer connection permit was issued in 1958. Previous known uses would be associated with indigenous populations with no recorded records. As a result, no archaeological or other cultural resources are known to exist on the project site. If archaeological, paleontological, or cultural resources or human remains are discovered, a standard City Condition of Approval will require proper handling of any discovered archeological or paleontological resources, per General Plan Strategy CNR-1.1b. Archaeological Resources: In accordance with CEQA and the State Public Resources Code, require the discontinuation of all work in the immediate vicinity and the preparation of a resource mitigation plan and monitoring program by a licensed archaeologist if archaeological resources are found on any sites within the City. Should human remains be discovered during excavation or construction, such remains shall be handled pursuant to § 7050.5 of the California Health and Safety Code and § 5097.94 of the California Public Resources Code. Specifically, in the event a human burial or skeletal element is identified during excavation or construction, work in that location shall stop immediately until the find can be properly treated. The Santa Clara County Coroner shall be notified and shall make a determination as to whether remains are Native American in origin and take such actions as required by law. Mitigation Measures(s): CUL – 1: If archaeological or paleontological resources are encountered during excavation or construction, construction personnel shall be instructed to immediately suspend all activity in the immediate vicinity of the suspected resources and the City and a licensed archeologist or paleontologist shall be contacted to evaluate the situation. A licensed archeologist or paleontologist shall be retained to inspect the discovery and make any necessary recommendations to evaluate the find under current CEQA guidelines prior to the submittal of a resource mitigation plan and monitoring program to the City for review and approval prior to the continuation of any on-site construction activity. Environmental Impact Evaluation – Geology and Soils Page No. 21 6. GEOLOGY AND SOILS Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Expose people or structures to potential substantial adverse effects, including the risk of loss, injury, or death involving: i) Rupture of a known earthquake fault, as delineated on the most recent Alquist-Priolo Earthquake Fault Zoning Map issued by the State Geologist for the area or based on other substantial evidence of a known fault? Refer to Division of Mines and Geology Special Publication 42. ii) Strong seismic ground shaking? iii) Seismic-related ground failure, including liquefaction? iv) Landslides? (b) Result in substantial soil erosion or the loss of topsoil? (c) Be located on a geologic unit or soil that is unstable, or that would become unstable as a result of the project, and potentially result in on- or off-site landslide, lateral spreading, subsidence, liquefaction or collapse? (d) Be located on expansive soil, as defined in Table 18-1-B of the Uniform Building Code (1994), creating substantial risks to life or property? (e) Have soils incapable of adequately supporting the use of septic tanks or alternative waste water disposal systems where sewers are not available for the disposal of waste water? (f) Directly or indirectly destroy a unique paleontological resource or site or unique geological feature? Discussion: (a): The project site is located within the seismically active San Francisco Bay Area. According to maps prepared under the Alquist-Priolo Earthquake Fault Zone Act, there are no zoned active faults within the City of Campbell. Therefore, ground rupture is not likely to occur at the site. The nearest major earthquake faults are the Monte Vista Shannon Fault, San Andreas Fault, the Hayward-Rogers Creek Fault and the Calaveras Fault, all of which pose the greatest earthquake threat because of their high quake potential. The project will likely be subjected to at least one moderate to severe earthquake that will cause moderate to severe ground shaking during the useful life of the building. Because construction practices in the State of California—pursuant to the California Building Code—take into account that earthquakes could potentially damage buildings, they are designed to withstand moderate ground- shaking, resulting in a less than significant impact. In regard to liquefaction, the geotechnical evaluation concluded that the property of liquefaction of the site is low due to the dense sandy gravel. Lastly, according to the State Seismic Hazard Zones Map, the project site is not located in any hazard zone and therefore does not have the potential for liquefaction or earthquake-induced landslides. (b): The project does not involve any grading, which would not result in substantial soil erosion or the loss of topsoil. (c): According to the Santa Clara County Geologic Hazard Zones Map, the project site is not geologically unstable and would not pose a risk of landslide, lateral spreading, subsidence, liquefaction or collapse. (d): A Geotechnical Investigation report prepared for this project evaluated the geotechnical conditions of the site. The review included three borings drilled to depths of 9 to 10 feet to obtain samples for laboratory tests. Based on the results of the investigation the subject site was determined to be Environmental Impact Evaluation – Geology and Soils Page No. 22 geotechnical suitable for the proposed development. With incorporation of Mitigation Measure GEO-1 —requiring compliance with all measures identified by the geotechnical report—the project would not be located soil that is unstable, or that would become unstable as a result of the project. (e): The project would not involve the use of septic tanks or alternative waste water disposal systems. (f): As discussed in Section 5 (Cultural Resources), no unique paleontological resources or unique geological features are known to exist on the project site. However, should such resources exist, their disturbance would be a potentially significant impact. Incorporation of Mitigation Measure CUL-1 will ensure that in such event, treatment of paleontological resources or unique geological features, would be conducted in an appropriate manner as to preserve their integrity. Mitigation Measures(s): GEO – 1: The applicant shall comply with the recommendations (Pages 12 through 14) in the Soil and Foundation Investigation of Proposed 4 Single Family Residences, dated April 29, 2016. Such recommendations shall be incorporated into the project’s final engineering design to minimize the damage from seismic shaking, unsuitable fill, and other geological deficiencies. The project shall use standard engineering techniques and conform to the requirements of the International Building Code to reduce the potential for seismic damage and risk to future occupants. Environmental Impact Evaluation – Greenhouse Gas Emissions Page No. 23 7. GREENHOUSE GAS EMISSIONS Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Generate greenhouse gas emissions, either directly or indirectly, that may have a significant effect on the environment? (b) Conflict with an applicable plan, policy or regulation adopted for the purpose of reducing the emissions of greenhouse gases? Discussion: (a): The BAAQMD May 2011 CEQA Guidelines included GHG emissions-based significance thresholds and established a “bright-line” emissions level of 1,100 metric tons per year for residential land-use type projects. On March 5, 2012 the Alameda County Superior Court issued a judgment finding that the Air District had failed to comply with CEQA when it adopted the Thresholds. The Air District had been ordered to set aside the Thresholds and is no longer recommending that these Thresholds be used as a general measure of project’s significant air quality impacts. Instead, the BAAQMD indicated that Lead agencies may continue to rely on the Air District’s 1999 Thresholds of Significance and make determinations regarding the significance of an individual project’s air quality impacts based on the substantial evidence in the record for that project. As such, the project was evaluated under both thresholds of significance as discussed below: In review of the Air District’s 1999 Thresholds of Significance for Housing, projects with over 320 single-family units were considered to potentially result in significant emissions. As the Project relates to a single family home, it is well below the 1999 Air District’s Thresholds of Significance. Under the May 2011 CEQA Guidelines, the potential project source greenhouse gas emissions come from vehicle traffic trips to and from the site. According to the screening threshold prepared by BAAQMD to determine what size of projects would likely result in significant greenhouse gas emissions, which is 1,100 meter metric tons, a single-family residential project would need to encompass 56 houses to achieve a greenhouse gas impact. As such, the proposed project, which pertains to the construction of four single-family residential units, is well below the May 2011 CEQA Guidelines significance thresholds. (b): The City of Campbell has not adopted a Climate Action Plan or any comparable policy or regulation pertaining to the reduction or monitoring of greenhouse gases. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Hazards and Hazardous Materials Page No. 24 8. HAZARDS AND HAZARDOUS MATERIALS Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Create a significant hazard to the public or the environment through the routine transport, use or disposal of hazardous materials? (b) Create a significant hazard to the public or the environment through reasonable foreseeable upset and accident conditions involving the release of hazardous materials into the environment? (c) Emit hazardous emissions or handle hazardous or acutely hazardous materials, substances, or waste within one-quarter mile of an existing or proposed school? (d) Be located on a site which is included on a list of hazardous materials sites complied pursuant to Government Code Section 65962.5 and, as a result, would it create a significant hazard to the public or the environment? (e) For a project located within an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project result in a safety hazard for people residing or working in the project area? (f) For a project within the vicinity of a private airstrip, would the project result in a safety hazard for people residing or working in the project area? (g) Impair implementation of or physically interfere with an adopted emergency response plan or emergency evacuation plan? (h) Expose people or structures to a significant risk of loss, injury or death involving wildland fires, including where wildlands are adjacent to urbanized areas or where residences are intermixed with wildlands? Discussion: (a and b): No routine transport, use or disposal of hazardous materials would be associated with the project. A slight hazardous potential would exist during the demolition of the existing home (which was built in the 1950’s and therefore may have lead or asbestos) and project construction when materials and construction equipment are at the site; however, long-term hazard risk is very low. With incorporation of Mitigation Measure HAZ-1 , which requires qualified contractors assess the presence of the lead and asbestos in order to property manage and dispose of such materials, the project would not create a significant hazard to the public or the environment through reasonable foreseeable upset and accident conditions involving the release of hazardous materials into the environment. Hazard risks during construction would be regulated by the City’s standard conditions of approval and will be required to be performed in accordance with state and federal hazardous materials regulations and current Best Management Practices (BMP’s) for construction activities. The use of toxic chemicals for landscaping (pesticides, herbicides, etc.) will not be above what is generally required for landscape maintenance and is not considered significant. (c): The project site is within ½ mile of the Farnham Elementary School, located southwest of the project site. However, the operation of the project will not include hazardous emission or handling of hazardous or acutely hazardous materials, substances. Further, as discussed in Section 3 (Air Quality), construction and demolition related air pollutants that may constitute a hazard are regulated through Best Management Practices as required by City Ordinances and reiterated through Mitigation Measure AIR – 1. Environmental Impact Evaluation – Hazards and Hazardous Materials Page No. 25 (d): The project site is not listed on the Hazardous Waste and Substances Sites List (available at http://www.dtsc.ca.gov/SiteCleanup/Cortese_List.cfm) compiled pursuant to Government Code Section 65962.5, therefore it would not create a significant hazard to the public or the environment. (e to f): The project site is not located within the Santa Clara County Airport Land Use Commission jurisdiction, within two miles of a public airport or within the vicinity of a private airstrip. (g): The project would not interfere with emergency response or evacuation plans. Sufficient emergency access and emergency services staff would be provided for the project site in compliance with the State of California Building Code Standards and requirements of the Santa Clara County Fire and Health Departments. (h): The project site is not located near any wildland areas and would not cause an increase in wildland fire hazard. Mitigation Measure(s): HAZ-1: Prior to issuance of a demolition permit, a qualified contractor shall assess the property for presence of Lead-based paint (LBP) and Asbestos containing building materials (ACBM), and if present, prepare a plan, to the satisfaction of the Building Official, to properly manage and dispose of such materials. Environmental Impact Evaluation – Hydrology and Water Quality Page No. 26 9. HYDROLOGY AND WATER QUALITY Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Substantially deplete groundwater supplies or interfere substantially with groundwater recharge such that there would be a net deficit in aquifer volume or a lowering of the local groundwater table level (e.g., the production rate of pre-existing nearby wells would drop to a level which would not support existing land uses or planned uses for which permits have been granted)? (b) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river, in a manner which would result in a substantial erosion or siltation on- or off-site. (c) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river, or substantially increase the rate or amount of surface runoff in a manner which would result in flooding on- or off-site? (d) Create the potential for significant changes in the flow velocity or volume of stormwater runoff to cause environmental harm? (e) Create significant increases in erosion of the project site or surrounding areas? (f) Create or contribute runoff water which would exceed the capacity of existing or planned storm water drainage systems or provide substantial additional sources of polluted runoff? (g) Otherwise substantially degrade water quality? (h) Place housing within a 100-year flood hazard area as mapped on a federal Flood Hazard Boundary or Flood Insurance Rate Map or other flood hazard delineation map? (i) Place within a 100-year flood hazard area structures which would impede or redirect flood flows? (j) Expose people or structures to a significant risk of loss, injury or death involving flooding, including flooding as a result of the failure of a levee or dam? (k) Inundation by seiche, tsunami, or mudflow? (l) Potentially impact stormwater runoff from construction activities? (m) Potentially impact stormwater runoff from post-construction activities? (n) Result in a potential for discharge of stormwater pollutants from areas of material storage, vehicle or equipment fueling, vehicle or equipment maintenance (including washing), waste handling, hazardous materials handling or storage, delivery areas, loading docks or other outdoor work areas? (o) Result in the potential for discharge of stormwater to affect the beneficial uses of the receiving waters? (p) Violate any water quality standards or waste discharge requirements? Discussion: (a and b): The project will be adequately served by existing water supplies, and will be served by the local area water utility as confirmed in written correspondence (“will serve” letter) by the San Jose Water Company. No violations of any water quality standards are expected from the project. The project would not directly deplete groundwater supplies (no wells) or interfere substantially with groundwater recharge (the project is evaluated for the amount of proposed pervious and impervious area to maintain or improve upon existing conditions) such that there would be a net deficit in aquifer volume or a lowering of the local groundwater table level. Environmental Impact Evaluation – Hydrology and Water Quality Page No. 27 (c to g): No significant increase in impervious surface area of the lot would result from the project. However, all additional runoff would be conveyed into the public storm drain system. These changes to the Project site would not substantially alter the existing drainage pattern of the area due to the small size of the site. Storm water would be conveyed into the public storm drain system. The course of streams or rivers would not be affected by the proposed Project. The runoff from construction of the proposed Project would not exceed the capacity of existing or planned stormwater drainage systems, provide substantial additional sources of polluted runoff, or substantially degrade water quality. (h and i): The entire project site is located in Flood Zone X, according to the Federal Emergency Management Agency (FEMA) Flood Insurance Rate Maps. Flood Zone X is defined as an areas determined to be outside the 0.2% annual chance floodplain. (j and k): The project site is located downstream of Lexington Reservoir, in an area defined by the Association of Bay Area Governments as a dam failure inundation area. However, as the units are located outside of the .02% annual chance floodplain the project would not expose a significant number of additional people or structures to a significant risk of loss, injury, or death involving flooding as the risk of dam failure is low. Furthermore, as the project is not modifying flood protection measures or creating a condition where adjacent properties are exposed to a new significant risk of loss, injury or death involving flooding, no additional exposure to water-related hazards is expected as a result of the project construction or operation. (l): As discussed in Section 3 (Air Quality), construction and demolition activities are regulated through Best Management Practices as required by City ordinances and reiterated by Mitigation Measure AIR – 1, which is designed to limit air and water contamination related to construction activity. With the implementation of this measure, as well as Mitigation Measure HAZ-1 which requires qualified contractors assess the presence of the lead and asbestos in order to property manage and dispose of such materials, the project would not create a significant hazard to the public or the environment through reasonable foreseeable upset and accident conditions involving the release of hazardous materials into the environment. (n): The project will not include uses that would include vehicle fueling, waste handling, hazardous material storage, or other outdoor work areas that could result in the potential discharge of stormwater pollutants. (o and p): The Project had been reviewed for compliance with Provision C.3 of the National Pollution Discharge Elimination System (NPDES) and had been determined to be below the required thresholds to trigger pollution prevention measures. Furthermore, as the project site does not include any material storage, vehicle or equipment fueling, vehicle or equipment maintenance, waste handling, hazardous materials handling or storage, delivery areas, loading docks, or other outdoor work areas, the project would not violate any water quality standards as it would not result in the potential for stormwater pollutants. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Land Use and Planning Page No. 28 10. LAND USE and PLANNING Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Physically divide an established community? (b) Conflict with any applicable land use plan, policy, or regulation of an agency with jurisdiction over the project (including, but not limited to the general plan, specific plan, local coastal program, or zoning ordinance) adopted for the purpose of avoiding or mitigating an environmental effect? (c) Conflict with any applicable habitat conservation plan or natural community conservation plan? Discussion: (a): Projects that have the potential to physically divide an established community typically include construction that would eliminate formal or informal travel ways through a property. No such pathways or other forms of informal access through the project site currently exist. Therefore, the project would not physically divide an established community. (b): The Campbell General Plan Land Use Element Diagram and Campbell Zoning Map designate the project site as Low Density Residential (less than 6 units/gr. acre) and R-1-6 (Single-Family Residential), respectively. The project would result in the creation of four residential parcels, and a common lot, at an approximate density of 5.1 units per gross acre and rezone the property to P-D (Planned Development) which allows for residential development within this density range. As such, the proposed subdivision would be consistent with the City of Campbell General Plan and Zoning Ordinance. (c): No habitat conservation plan or natural community conservation plans are applicable to the project site. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Mineral Resources Page No. 29 11. MINERAL RESOURCES Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Result in the loss of availability of a known mineral resource that would be of value to the region and the residents of the state? (b) Result in the loss of availability of a locally-important mineral resource recovery site delineated on a local general plan, specific plan or other land use plan? Discussion: (a to b): No known mineral resources are present at the project site. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Noise Page No. 30 12. NOISE Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Exposure of persons to or generation of noise levels in excess of standards established in the local general plan or noise ordinance, or applicable standards of other agencies? (b) Exposure of persons to or generation of excessive groundborne vibration or groundborne noise levels? (c) A substantial permanent increase in ambient noise levels in the project vicinity above levels existing without the project? (d) A substantial temporary or periodic increase in ambient noise levels in the project vicinity above levels existing without the project? (e) For a project located within an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project expose people residing or working in the project area to excessive noise levels? (f) For a project within the vicinity of a private airstrip, would the project expose people residing or working in the project area to excessive noise levels? Discussion: (a to b): The City's Noise Ordinance (CMC Sec. 21.16.070.E) provides the following noise exposure standards for new residential development: • Noise from stationary sources. New residential development shall conform to a stationary source noise exposure standard of 65 dBA for exterior noise levels and 45 dBA for interior noise levels. • Traffic-related noise. New residential development shall conform to a traffic-related noise exposure standard of 60 dBA CNEL for outdoor noise in noise-sensitive outdoor activity areas and 45 dBA CNEL for indoor noise. Acoustical studies are required for all new noise-sensitive projects that may be affected by existing noise, including all new residential developments with a noise exposure greater than 60 dBA CNEL. As the project site is located within the vicinity of a noise contour area (Camden Avenue) identified in the General Plan (reference Pg. CNR-9 – Figure CNR-2) as having noise-related conditions in excess of 60 dBA CNEL, the residential units could be exposed to noise in excess of local standards. The proposed mitigation measures, which require an acoustical study, sound rated windows and doors, and the provision of HVAC units for all new houses to allow occupants to achieve the desired amount of acoustical isolation, will reduce potential noise impacts and exposure for future residents to a less than significant level. (c): Single-family residences are classified as sensitive receptors of noise, and to this extent do not themselves generate noise of any appreciable level. As such, the project would not result in increase in ambient noise within the vicinity of the project site. (d): Construction of single-family residences that will eventually result from the project will temporarily increase ambient noise levels in the project vicinity. However, future construction is governed by CMC Sec. 18.04.052, which limits construction activity from 8 AM to 5 PM., Monday through Friday, 9 AM to 4 PM on Saturday, and prohibits construction on Sunday or National Holidays. Additionally, loud environmentally disruptive noise over 50dBA (e.g., air compressors without mufflers, continuously running motors or generators, loud playing musical instruments or Environmental Impact Evaluation – Noise Page No. 31 radios) is prohibited. As such, temporary ambient noise level increases associated with construction will be less than significant. (e and f): The project is not located within the vicinity of an airport land use plan or within two miles of an airport. The project is not located within the vicinity of a private airstrip. Mitigation Measure(s): NOI-1: Mechanical ventilation (HVAC) shall be included in all residences constructed to allow occupants to close doors and windows as desired to achieve additional acoustic isolation. Further, the project building plans shall incorporate dual pane thermal windows and acoustically effective doors with a rated minimum Sound Transmission Class (STC) as recommended by the acoustical study. NOI-2: An acoustical study shall be prepared for the project which will study existing noise conditions, the project plans, and provide specific structural recommendations to comply with the noise exposure limits identified in the Campbell General Plan. The project building plans shall incorporate the recommendations as mitigation measures. Environmental Impact Evaluation – Population and Housing Page No. 32 13. POPULATION AND HOUSING Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Induce substantial population growth in an area, either directly (for example, by proposing new homes and businesses) or indirectly (for example, through extension of roads or other infrastructure)? (b) Displace substantial numbers of existing housing, necessitating the construction of replacement housing elsewhere? (c) Displace substantial numbers of people, necessitating the construction of replacement housing elsewhere? Discussion: (a): The project will eventually result in the construction of four single-family residential units on a property identified by the Campbell General Plan Housing Element as being suitable and appropriate for housing. The introduction of four single-family residences in a predominantly developed residential neighborhood represents only a nominal increase of population growth. There is no foreseeable indirect population growth associated with the project. The infrastructure provided to service the project site is designed to serve only the proposed residential units. (b and c): The project will require the demolition of the existing residence, and build four new residential units. Therefore the project will not result in the displacement of any people or housing units, which would necessitate the construction of replacement housing elsewhere. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Public Services Page No. 33 14. PUBLIC SERVICES Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Would the project result in substantial adverse physical impacts associated with the provision of or need for new or physically altered governmental facilities, the construction of which could cause significant environmental impacts, in order to maintain acceptable service ratios, response times or other performance objectives for any of the public services: i) Fire Protection? ii) Police Protection? iii) Schools? iv) Parks? v) Other public facilities? Discussion: (a): The project will require public services such as fire, police services, schools, open space, and street maintenance, commensurate with the scale of the project. The County Fire District, Campbell Police Department, City stakeholder agencies, and area school districts reviewed the project and determined services could be provided at an acceptable level. Existing parkland is sufficient to serve the residents of the project, as discussed in Section 15 (Recreation) and the developer will be required to pay park fees for the creation of new residential units less a credit for the removal of an existing unit. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Recreation Page No. 34 15. RECREATION Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Would the project increase the use of existing neighborhood and regional parks or other recreational facilities such that substantial physical deterioration of the facility would occur or be accelerated? (b) Does the project include recreational facilities or require the construction or expansion of recreational facilities which might have an adverse physical effect on the environment? Discussion: (a): Residents of the project are likely to access Campbell Technology Park located roughly a mile north of the project site or Los Gatos County Park located roughly half a mile to the west of the project site. Due to the limited scope and scale of the project, only a nominal increase in the use of City and regional parks and other recreational facilities can be expected as a result of the project. (b): The project does not any include recreational facilities. The project shall be required to pay park fees less the credit for one existing unit. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Transportation and Traffic Page No. 35 16. TRANSPORTATION and TRAFFIC Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Cause an increase in traffic which is substantial in relation to the existing traffic load and capacity of the street system (i.e., result in a substantial increase in either the number of vehicle trips, the volume to capacity ratio on roads, or congestion at intersections)? (b) Exceed, either individually or cumulatively, a level of service standard established by the county congestion management agency for designated roads or highways? (c) Result in a change in air traffic patterns, including either an increase in traffic levels or a change in location that results in substantial safety risks? (d) Substantially increase hazards due to a design feature (e. g., sharp curves or dangerous intersections) or incompatible uses (e.g., farm equipment)? (e) Result in inadequate emergency access? (f) Result in inadequate parking capacity? (g) Conflict with adopted policies, plans, or programs supporting alternative transportation (e.g., bus turnouts, bicycle racks)? Discussion: (a and b): A trip generation analysis based on the Institute of Transportation Engineers (ITE) Trip Generation Manual, prepared by the City Traffic Engineer anticipates that the project (net) would result in a an average of 29 daily trips, including 2 AM peak hour (7:00 – 9:00) trips and 3 PM peak hour (4:00 – 6:00) trips. This nominal increase in trips would not result in a substantial increase in either the number of vehicle trips, the volume to capacity ratio on roads, or congestion at area intersections. Net Project Trips Land Use Qty Units AM Peak PM Peak Total Inbound Outbound Total Inbound Outbound ADT Existing Unit (Removed) -1 DU -1 0 -1 -1 -1 0 -9 Proposed Unit (5 Added) 4 DU 3 1 2 4 3 1 38 Net Trips 3 DU 2 1 1 3 2 1 29 (c): The project will not result in a change in air traffic patterns, including either an increase in traffic levels or a change in location that results in substantial safety risks. (d): The proposed public roadway is designed consistent with public roadway standards for residential streets as determined by the City Engineer and would not result in hazards due to a design features or incompatible uses. (e): The project has been designed to comply with emergency access requirements of the Santa Clara Fire Department. The project plans include an emergency vehicle access plan that illustrates compliance with said standards. The County Fire Department has reviewed the project during the City’s department review committee process and will again review the access routes during review of construction drawings. Environmental Impact Evaluation – Transportation and Traffic Page No. 36 (f): The proposed single-family development is subject to the City’s parking standard of two and a half covered spaces per unit plus half a space designated for guest parking per unit (eight covered, two uncovered). The applicant is proposing to provide uncovered parking in lieu of required covered which will result in adequate parking capacity (eight covered parking spaces, 5 uncovered parking spaces). (g): The project site is not in vicinity of any light-rail or comparable bus rapid transit (BRT) line (the closest bus stops occur at Bascom and Shelley and Bascom and Camden), and as a result is not subject to City policies encouraging alternative transporting solutions (e.g., provision of transit-passes, incorporation of bicycle parking, etc.). Additionally, the City’s adopted requirements for alternative transportation solutions per CMC Sec. 21.28.070 require provision bicycle and clean-air vehicle parking only for non-residential development subject to the Green Building Standards Code (CALGreen). The project, therefore, will not conflict with adopted policies, plans, or programs supporting alternative transportation. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Utilities and Service Systems Page No. 37 17. UTILITIES and SERVICE SYSTEMS Issues Would the project: Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Exceed wastewater treatment requirements of the applicable Regional Water Quality Control Board? (b) Require or result in the construction of new water or wastewater treatment or collection facilities or expansion of existing facilities, the construction of which could cause significant environmental effects? (c) Require or result in the construction of new storm water drainage facilities or expansion of existing facilities, the construction of which could cause significant environmental effects? (d) Have sufficient water supplies available to serve the project from existing entitlements and resources, or are new or expanded entitlements needed? (e) Result in a determination by the wastewater treatment provider which serves or may serve the project that it has adequate capacity to serve the project’s projected demand in addition to the provider’s existing commitments? (f) Be served by a landfill with insufficient permitted capacity to accommodate the project’s solid waste disposal needs? (g) Comply with federal, state, and local statutes and regulations related to solid wastes. Discussion: (a and b): The project would not exceed wastewater treatment requirements of the applicable Regional Water Quality Control Board; require or result in the construction of new water or wastewater treatment facilities or expansion of existing facilities. The West Valley Sanitation District has provided written correspondence (“will serve” letter) which indicates that the sewer facilities are adequate to support the site. (c): The stormwater runoff generated by the project site would be collected and treated on-site in compliance with Provision C.3 of the National Pollution Discharge Elimination System (NPDES) requirements as discussed in Section 9 (Hydrology and Water Quality) and will not require expansion or construction of new stormwater treatment facilities. (d): The project will be adequately served by the existing water supplies, as confirmed in written correspondence (“will serve” letter) by San Jose Water Company, the local area water utility. (e): The project would connect to the existing waste water treatment system, which currently has sufficient capacity to receive the additional waste water generated from the proposed project. Therefore, the project would not impact the ability of the waste water treatment provider (West Valley Sanitation District) to meet its current commitments for service. (f to g): Existing capacity at local landfills can accommodate the amount of waste generated as a result of project operation. The project would comply with Federal, State and local statutes and regulations related to solid waste. Mitigation Measure(s): None Required. Environmental Impact Evaluation – Mandatory Findings of Significance Page No. 38 18. MANDATORY FINDINGS OF SIGNIFICANCE Issues Potentially Significant Impact Less than Significant With Mitigation Incorporated Less Than Significant Impact No Impact (a) Does the project have the potential to degrade the quality of the environment, substantially reduce the habitat of a fish or wildlife species, cause a fish or wildlife population to drop below self-sustaining levels, threaten to eliminate a plant or animal community, reduce the number or restrict the range of a rare or endangered plant or animal or eliminate important examples of the major periods of California history or prehistory? (b) Does the project have impacts that are individually limited, but cumulatively considerable? (“Cumulatively considerable” means that the incremental effects of a project are considerable when viewed in connection with the effects of past projects, the effects of other current projects, and the effects of probable future projects?) (c) Does the project have environmental effects which will cause substantial adverse effects on human beings, either directly or indirectly? Discussion: (a): Based on the findings of the Initial Study, construction and operation of the project, with mitigation, would not substantially degrade the quality the environment; reduce the habitat, population, or range of species; nor eliminate important examples of California history or prehistory. (b): Based on the findings of this Initial Study, the project would not have individual or cumulative environmental impacts that cannot be mitigated to a less than significant level. (c): Based on the findings of the Initial Study, there is no evidence to demonstrate that the project would cause a substantial adverse effect on human beings, either directly or indirectly. Mitigation Measure(s): None Required. Recommendation and Determination Page No. 39 III. RECOMMENDATION and DETERMINATION Recommendation: On the basis of this initial evaluation, the following measures are recommended to reduce potentially significant effects on the environment to a less than significant level: 1. Aesthetics: None Required 2. Agricultural Resources: None Required 3. Air Quality: AIR – 1: The project applicant shall ensure that construction plans include the BAAQMD Best Management Practices for fugitive dust control. The following will be required for all construction activities within the project area. These measures will reduce fugitive dust emissions primarily during soil movement, grading and demolition activities, but also during vehicle and equipment movement on unpaved project sites: a. Use dust-proof chutes for loading construction debris onto trucks. b. Water or cover stockpiles of debris, soil, and other materials that can be blown by the wind. c. Cover all trucks hauling soil, sand, and other loose materials or require all trucks to maintain at least two feet of freeboard. d. Sweep daily (with water sweepers) all paved access roads, parking areas, and staging areas at the construction site. e. Sweep streets daily (with water sweepers) if visible soil material is carried onto adjacent public streets, as directed by the City Engineer. f. Enclose, cover, water twice daily or, or apply (non-toxic) soil stabilizers to exposed stockpiles (dirt, sand, etc.). g. Install erosion control measures to prevent runoff from the project site. 4. Biological Resources: None Required 5. Cultural Resources: CUL-1: If archaeological or paleontological resources are encountered during excavation or construction, construction personnel shall be instructed to immediately suspend all activity in the immediate vicinity of the suspected resources and the City and a licensed archeologist or paleontologist shall be contacted to evaluate the situation. A licensed archeologist or paleontologist shall be retained to inspect the discovery and make any necessary recommendations to evaluate the find under current CEQA guidelines prior to the submittal of a resource mitigation plan and monitoring program to the City for review and approval prior to the continuation of any on-site construction activity. 6. Geology and Soils: GEO – 1: The applicant shall comply with the recommendations (Pages 12 through 14) in the Soil and Foundation Investigation of Proposed 4 Single Family Residences, dated April 29, 2016. Such recommendations shall be incorporated into the project’s final engineering design to minimize the damage from seismic shaking, unsuitable fill, and other geological deficiencies. The project shall use standard engineering techniques and Recommendation and Determination Page No. 40 conform to the requirements of the International Building Code to reduce the potential for seismic damage and risk to future occupants. 7. Greenhouse Gas Emissions: None Required 8. Hazards and Hazardous Materials: HAZ-1: Prior to issuance of a demolition permit, a qualified contractor shall asses the property for presence of Lead-based paint (LBP) and Asbestos containing building materials (ACBM), and if present, prepare a plan, to the satisfaction of the Building Official, to properly manage and dispose of such materials. 9. Hydrology and Water Quality: None Required 10. Land Use and Planning: None Required 11. Mineral Resources: None Required 12. Noise: NOI-1: Mechanical ventilation (HVAC) shall be included in all residences constructed to allow occupants to close doors and windows as desired to achieve additional acoustic isolation. Further, the project building plans shall incorporate dual pane thermal windows and acoustically effective doors with a rated minimum Sound Transmission Class (STC) as recommended by the acoustical study. NOI-2: An acoustical study shall be prepared for the project which will study existing noise conditions, the project plans, and provide specific structural recommendations to comply with the noise exposure limits identified in the Campbell General Plan. The project building plans shall incorporate the recommendations as mitigation measures. 13. Population and Housing: None Required 14. Public Services: None Required 15. Recreation: None Required 16. Transportation and Traffic: None Required 17. Utilities and Service Systems: None Required 18. Mandatory Findings of Significance: None Required Recommendation and Determination Page No. 41 Determination: On the basis of this initial evaluation, and incorporation of the recommended mitigation measures into the project design: 1. I find that the project could not have a significant effect on the environment, and a NEGATIVE DECLARATION will be prepared. 2. I find that although the proposed project could have a significant effect on the environment, there will not be a significant effect in this case because revisions in the project have been made by or agreed to by the project proponent. A MITIGATED NEGATIVE DECLARATION will be prepared. 3. I find the proposed project may have a significant effect on the environment, and an ENVIRONMENTAL IMPACT REPORT is required. 4. I find that the proposed project may have a “potentially significant impact” or “potentially significant unless mitigated impact” on the environment, but at least one effect 1) has been adequately analyzed in an earlier document pursuant to applicable legal standards, and 2) has been addressed by mitigation measures based on the earlier analysis as described on attached sheets. An ENVIRONMENTAL IMPACT REPORT is required, but it must analyze only the effects that remain to be addressed. 5. I find that although the proposed project could have a significant effect on the environment, because all potentially significant effects (a) have been analyzed adequately in an earlier EIR or Negative Declaration pursuant to applicable standards, and (b) have been avoided or mitigated pursuant to that earlier EIR or Negative Declaration, including revisions or mitigation measures that are imposed upon the proposed project, nothing further is required. Stephen Rose PROJECT PLANNER Associate Planner TITLE City of Campbell AGENCY _____________________________ July 29, 2016 SIGNATURE DATE Environmental Impact Evaluation – Reference Materials Page No. 42 IV. REFERENCE MATERIALS Exhibits (May be viewed at http://www.cityofcampbell.com/General/PublicNotices.htm): 1. Geotechnical Investigation by American Soil Testing, Inc. dated April 29, 2016. 2. Phase I Environmental Site Assessment by IRC Environmental Consulting, dated April 20, 2016. 3. Air Quality Report by The Cohen Group, dated June 7, 2016. 4. Tree Inventory and Assessment by Saratoga Tree Service, dated May 4, 2016. 5. Will Serve Letters Reference Documents: 1. Bay Area Air Quality Management District (BAAQMD), June 2010, CEQA Air Quality Guidelines. 2. Bay Area Air Quality Management District (BAAQMD), December 2008, Source Inventory of Bay Area Greenhouse Gas Emissions. 3. California Environmental Protection Agency (CEPA) California Air Resources Board (CARB), April 2005, Air Quality and Land Use Handbook: A Community Health Perspective. 4. California Environmental Protection Agency (CEPA) California Air Resources Board (CARB), November 16, 2007, Staff Report: California 1990 Greenhouse Gas Emissions Level and 2020 Emissions Limit. 5. California Natural Diversity Database, 2000. 6. California Office of Planning and Research (OPR), June 19, 2008, Technical Advisory: CEQA and Climate Change: Addressing Climate Change through California Environmental Quality Act (CEQA) Review. 7. CEQA Guidelines, 2012 version. 8. City of Campbell General Plan. 9. City of Campbell Zoning Code. 10. Federal Emergency Management Agency (FEMA) Flood Insurance Rate Map, Community Map Number 06085C0239H, Effective Date May 18, 2009. 11. State of California, Seismic Hazard Zones Map, San Jose West Quadrangle, February 7, 2002. 12. U.S. Environmental Protection Agency, April 15, 2009, Inventory of U.S. Greenhouse Gas Emissions and Sinks: 1990-2007. EXHIBIT 1 GEOTECHNICAL INVESTIGATION Soil and Foundation Investigation of Proposed 4 Single Family Residences 1323 Parsons Avenue Campbell, California Prepared for Mr. Omid Shakeri 12280 Saratoga Sunnyvale Rd. Suite 109 Saratoga, CA 95070 American Soil Testing, Inc. 2734 S. Bascom Avenue San Jose, CA 95124 (408) 559-6400 File No. 16-4006-S American Soil Testing, Inc. 1 American Soil Testing, Inc. Soil, Foundation and Environmental Engineers 2734 S. Bascom Avenue, San Jose, CA 95124 408-559-6400 - Fax 408-559-6688 www.americansoiltestinginc.com File No. 16-4006-S April 29, 2016 Mr. Omid Shakeri 12280 Saratoga Sunnyvale Rd. Suite 109 Saratoga, CA 95070 Subject: Proposed4 single family residences 1323 Parsons Avenue, APN: 414-37-008 Campbell, California Soil and Foundation Investigation Gentlemen Per your request and authorization, our firm has performed a Soil and Foundation Investigation for the above-mentioned project. The site is located at 1323 Parsons Avenue in Campbell, California. Our findings indicated that the proposed 4 one or two story wood framed single family residences may be constructed on the above mentioned property provided the recommendations contained in this report are carefully followed and implemented during construction. This report presents our findings on the surface and subsurface soil investigation, laboratory test results, field and office studies. File No. 16-4006-S American Soil Testing, Inc. 2 We are pleased to have been of service to you in this matter. Should you have any question or require additional information, please feel free to call our office at your convenience. Very truly yours, American Soil Testing, Inc. Ben Rahimi, MSCE, EP Senior Project Engineer Andrew A. Ghofrani, P.E. R.C.E. # 38159 Expire: 3-31-17 California Code of Regulations, Title 16, Division 5, 400-476 Article 1. General Provisions 411. Seal and Signature. (Partial) (e) The Seal shall be capable of leaving an electronically-generated representation on the documents. The signature may be applied to the documents electronically. Please contact American Soil Testing if Authenticity is questionable: 408-559-6400 File No. 16-4006-S American Soil Testing, Inc. 3 TABLE OF CONTENTS PAGE INTRODUCTION SITE DESCRIPTION AND LOCATION FIELD INVESTIGATION LABORATORY INVESTIGATION SUBSURFACE CONDITIONS SEISMIC DESIGN GRADING SPECIFICATIONS FOUNDATIONS DESIGN CRITERIA CONCRETE SLABS-0N-GRADE RETAINING WALLS GENERAL CONSTRUCTION SUB DRAIN PLAN REVIEW AND CONCLUSIONS LIMITATIONS APPENDIX A VICINITY MAP SITE PLAN APPENDIX B LOGS OF BORINGS PLASTICITY INDEX KEY TO EXPLORATORY BORING LOGS _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ _________________ 4 4 4 5 5 6 12 15 18 20 21 23 24 25 26 27 28 29 30-33 34 35 File No. 16-4006-S American Soil Testing, Inc. 4 SOIL INVESTIGATION Introduction The purpose of the soil investigation was to gather sufficient data to provide recommendations for foundation engineering. This report presents an explanation of how we conducted that investigation, the results of the testing program, our conclusions based upon their results, and our recommendations for earthwork and foundation design to best suit the proposed development to the existing natural conditions. Site Description and Location of Project The site is located at1323 Parsons Avenue in Campbell, California. APN: 414-37-008 At the time of our investigation the subject property was an existing one story single-family dwelling with an attached two car garage. The Structure was built in 1950. The lot was approximately 32,155 SF irregular shaped parcel of land. The site is flat and slightly higher than the street level. The proposed structures will be constructed at designated pads, which will be located at later date. We observed a few small to midsize trees limited landscaped areas inside of the property. At the time of our site visit, the property access was through Parsons Avenue. Field Investigation After consideration of the nature of the proposed development, review of available data on the area, and discussion with the client, a field investigation was conducted at the project site. It included a surface site reconnaissance to detect any unusual surface features and drilling of four borings on 4-13-2016 to determine subsurface soil characteristics. The approximate boring location is shown on Appendix A, Figure 2. The soil encountered was logged in the field. Relatively undisturbed subsurface samples File No. 16-4006-S American Soil Testing, Inc. 5 were obtained by hammering a split tube sampler into the natural ground. The boring log, Figures 1-4 (Appendix B) is graphic representation of the soil profile, showing the depths at which the samples were obtained. Laboratory Testing Parameters Samples were reviewed along with field logs to determine which would be analyzed further. Those chosen for laboratory analysis were considered representative of soil that would be exposed and used during grading. And those deemed to be within the influence of the proposed structure. Liquid limit and plasticity index (Atterberg limits) indicate the plasticity Characteristics of a soil, ASTM D 4318. The estimates are based on test data from the survey area or field examination. Maximum density was performed to estimate the moisture-density relationship of typical soil materials. The tests were performed in accordance with ASTM designation D 1557-12. Classification of the soils is determined according to the Unified soil classification System (ASTM, D2487) American Society for Testing and Materials (ASTM). 2011. Standard classification of soils for engineering purposes. ASTM Standard D2487. The Unified system classifies soils according to properties that affect their use as construction material. Soils are classified according to particle-size distribution of the fraction less than 3 inches in diameter and according to plasticity index, Liquid Limit and organic matter content. Silty and clayey soils as CL Two groups can have a dual classification, for example, ML-CL. The results of laboratory tests are summarized on Appendix "B". File No. 16-4006-S American Soil Testing, Inc. 6 Subsurface Conditions After reviewing the laboratory test data, boring logs and examination of the soil samples collected in different depths, the subsurface soils underlying the project site appears to be relatively uniform throughout the area. The upper silty clay has a low to moderate expansion potential. The surface and near surface soils consist of very stiff brown Sandy Silty Clay with large gravel and cobbles at the lower depth. Seismic Design Criteria The subject site is located in the seismically active San Francisco Bay region; therefore any structure within this area will most likely be subjected to strong ground shaking sometime during its actual lifetime. Major Faults like San Andreas Faults, Calaveras Faults and Hayward Faults have produced large magnitude earthquake in the past and can be expected to do so within the next 50 years. It is reasonable to assume that the proposed building will be subjected to at least one moderate to severe earthquake during the 50 years period following construction. During such an earthquake, severe ground shaking will occur at the site. The proposed residence is to be designed in accordance with the applicable provisions set forth in the current edition of the California Building Code (CBC). The following may be used from the California Building Code, CBC, 2013 Edition: Conterminous 48 States 2009 NEHRP Seismic Design Provisions 2010 ASCE 7 Standard Address: 1323 Parsons Avenue in Campbell, California from geocoder.ca latitude longitude altitude decimal 37.268111 -121.944583 deg-min-sec 37° 16' 5.1996" -121° 56' 40.4988" File No. 16-4006-S American Soil Testing, Inc. 7 User–Specified Input Report Title: 1323 Parsons Avenue Campbell, CA, 95008 Building Code Reference Document: ASCE 7-10 Standard(which utilizes USGS hazard data available in 2008) Site Coordinates: 37.26811°N, 121.94458°W Site Soil Classification: Site Class D – “Stiff Soil” Risk Category: I/II/III USGS–Provided Output SS = 1.904 g SMS = 1.904 g SDS = 1.269 g S1 = 0.652 g SM1 = 0.977 g SD1 = 0.652 g File No. 16-4006-S American Soil Testing, Inc. 8 Structure Engineer for this project should make his own independent evaluation as to the applicability of the seismic design criteria presented in the CBC, 2013 Edition. Consideration should also be given to anchoring or otherwise stabilizing freestanding appliances or home furnishings, which may be prone to toppling during seismic vibrations. Potential Geologic and Geotechnical Hazards: Secondary effects of seismic activity, which are normally considered as potential hazard to the site, include several types of ground failure. Various general types of ground failures, which might occur as a consequence of several ground shaking including land sliding, ground subsidence, ground lurching, shallow ground rupture, and liquefaction. The probability of occurrence of each type of these ground failures depends on the severity of the earthquake, distance from faults, topography, subsurface conditions, ground water elevation, and other factors. Seismic Shaking: Ground Shaking, this hazard is common to all properties in California. Mitigate by proper structural design and by following the recommendations presented in our Soil and Foundation Investigation Report. File No. 16-4006-S American Soil Testing, Inc. 9 The site is located in the seismically active San Francisco Bay Area. Several major earthquakes, which have been produced by movement on one of the principal active faults, affected the region during historic time. These earthquakes include the 1868 earthquake on the Hayward Fault and the 1906 San Francisco and recent 1989 Loma Prierta earthquakes originating on the San Andreas Fault. Considering the past seismic history of the region, the site will be affected by strong seismic shaking during the expected lifetime of the proposed building. The intensity of shaking is determined by the distance of the site to the seismic source and the properties of the material along the path of the transmitted energy. To mitigate the shaking effects, all structures should be designed using engineering judgement and the latest Building Code requirements and the latest standards of practice design methods. Seismic design provisions of current building codes generally prescribe minimum forces applied statically to the structure, combined with the gravity forces of dead and live loads. The code- prescribed lateral forces are generally considered to be substantially smaller than the forces that would be associated with major earthquake. Therefore, structures should be able: (1) Resist minor earthquake without damage. (2) Resist moderate earthquakes without structural damage but with some nonstructural damage and (3) Resist major earthquakes without collapse but with some structural as well as nonstructural damage. Conformance to building code recommendations does not constitute any kind of guarantee that significant structural damage would not occur in the event of a maximum magnitude earthquake. However, it is reasonable to assume that a well-designed and well-constructed structure will not collapse or cause loss of life in a major earthquake. Lurching: Ground lurching is a result of the rolling imparted to the ground during File No. 16-4006-S American Soil Testing, Inc. 10 energy released by an earthquake. Such rolling motion causes ground cracks to form. The potential for the formation of these cracks is considered greater at contacts between deep alluvium and bedrock. Such an occurrence is possible at other locations in the Bay Area, but based on the site location; it is our opinion that the offset is expected to be nil. Liquefaction: Soil liquefaction is a phenomenon in which saturated, cohesionless, loose soil experience a temporary, but essentially total loss of shear strength when subjected to reversing cyclic shear stresses caused by earthquake ground shaking. The soil material encountered in the borings drilled consist of stiff to very stiff silty clay. Groundwater was not encountered. The clayey material encountered has no potential for liquefaction. Lateral Spreading: Such seismically generated movements are induced in areas with weak soils near open cuts or slopes or in the areas of moderate to high liquefaction potential. The subject site is level-ground at the building pad and pool area and moderate slope at the easterly side. Exploratory borings on the property encountered well- consolidated soil at shallow depths. The potential for ground failure from liquefaction, lateral spreading or other seismically activated ground failure appears low. File No. 16-4006-S American Soil Testing, Inc. 11 URL http://quake.wr.usgs.gov/seismology/wg02 Earthquake Probability Map Figure 1. The threat of earthquakes extends across the entire San Francisco Bay region, and a major quake is likely before 2030. Knowing this will help people make informed decisions as they continue to prepare for future quakes. File No. 16-4006-S American Soil Testing, Inc. 12 RECOMMENDATIONS Grading Specifications 1. The placement of fill and control of any grading operations at the site shall be done in accordance with the recommendations of this report prepared by American Soil Testing Inc. These recommendations set forth the minimum standards to satisfy all requirements of this report. 2. All existing surface and subsurface structures that will not be incorporated in the final development shall be removed prior to any grading operations. These objects shall be accurately located on the grading plans (prepared by the project Civil Engineer) to assist the Field Engineer in establishing proper control over their removal. This is to include but not be limited to any basements, utility lines, underground tanks, and any other improvements. A representative of American Soil Testing Inc. shall be present during the demolition operation. 3. All organic surface material and debris, including organically rich top soil estimated to be 2-4 inches deep, shall be stripped prior to any other grading operations and transported away from all areas that are to receive improvements or structural fill. These organically contaminated soils may be stockpiled for later use in landscaping areas. This material is not suitable for use as structural fill. In addition, any trees that are not being included in the final development must be removed. This removal is to include a thorough cleaning of all underground roots. 4. The depressions left by the removal of any surface and subsurface structures shall be cleaned of all debris and backfilled with clean, native, on-site soil. This backfill shall be compacted to not less than 90% relative compaction in accordance with ASTM test procedure D1557- 12. ASTM D1557-12 Standard Test Methods for Laboratory Compaction 5. Following the stripping operations, the exposed surface shall be scarified to a depth of not less than 12 inches, conditioned as necessary (3 to 4 percent above optimum moisture content) and compacted to 90% relative compaction according File No. 16-4006-S American Soil Testing, Inc. 13 to ASTM test procedure D1557- 12. At this point, the pad area will be in condition to receive compacted fill. Based on exposed field condition if deemed necessary, Soil Engineer may provide additional recommendation in the field. 6. All structural fill whether imported or native soil shall be placed in uniform horizontal lifts of not more than 6 to 8 inches in uncomplicated thickness and compacted to not less than 90% relative compaction using the ASTM test procedure D1557-12. Five feet around the entire perimeter of the building pad shall also be compacted to not less than 90% relative compaction using the above- mentioned procedure. Before compaction begins, the fill shall be brought to a water content that will permit proper compaction by either: 1) Aerating the material if it is too wet, or 2) spraying the material with water if it is too dry. Each lift shall be thoroughly mixed before compaction to assure a uniform distribution of water content. When fill material includes rocks, nesting of rocks will not be permitted, and all voids shall be carefully filled and properly compacted, No rocks larger than 4 inches in diameter shall be used in the construction of the building pad. 7. The Soil Engineer shall be notified at least 48 hours prior to commencement of any grading operations so that he may coordinate the work in the field with the Grading Contractor. 8. All imported borrow must be sampled, tested and approved by the Soil Engineer prior to being brought to the site. Import soil must have a plasticity index no greater than (12) and an "R" value greater than (25). 9. All grading work shall be observed and approved by a Soil Engineer from American Soil Testing Inc. 10. In the event that any unusual condition not covered by the special provisions is encountered during the grading operations, the Soil Engineer shall be immediately notified for further recommendation. File No. 16-4006-S American Soil Testing, Inc. 14 Trench and over excavation area backfill Utility, pipeline trenches and over excavation areas should be backfilled with compacted structural fill. If on-site soil is used, the material should be placed in lifts not exceeding 8 inches in uncompacted thickness and compacted to at least 90 percent relative compaction by mechanical means only. Imported sand may also be used for backfilling trenches provided the sand is compacted to at list 90 percent relative compaction. In all Building pad areas and pavements, the upper 3 feet of trench backfill should be compacted to at least 95 percent relative compaction where imported sand backfill is used. In addition the upper 8 inches of all trench backfill in pavement area should be compacted to at least 95 percent relative compaction (ASTM D1557-12. Water Wells All water wells (if any) on the site, which are to be abandoned, shall be capped according to the requirements of the Santa Clara Valley Water District. The final elevation of the top of the well casing must be a minimum of 3 feet below any adjacent grade prior to any grading operations. In no case shall a building foundation be placed over a capped well. File No. 16-4006-S American Soil Testing, Inc. 15 FOUNDATION DESIGN CRITERIA The proposed structure may be supported on continuous perimeter footings with isolated interior spread footings or piers and grade beam type of foundation. 1. All continuous perimeter and isolated interior spread footings shall be founded a minimum 24 inches below the pad or 18 inches below the lowest adjacent grade. For the above conditions, the footings may be designed for an allowable bearing value of 1800 p.s.f. for both continuous strip footing and isolated interior spread footings. This bearing value is for dead plus live loads and may be increased by one-third to include short-term seismic and wind effects. 2. All footing located adjacent to utility trenches should have their bearing surfaces below an imaginary 2:1 (horizontal to vertical) plane projected upward from the bottom of the trench. All continuous footing should be designed with adequate top and bottom reinforcement to provide structural continuity and to permit spanning of local irregularities. 3. The final design of the foundations and reinforcing required shall be determined by the project Structural Engineer responsible for the foundation design. It is suggested that the foundation design be reviewed by American Soil Testing Inc. prior to construction. Pier & Grade Beam Friction piers and grade beam construction is another type of foundation. As alternative type of foundation, the proposed structure may be supported on drilled, cast-in-place, straight-shaft piers and grade beam type foundation. 1. The piers should be at least 16 inches in diameter and should penetrate a minimum of 6 feet below the bottom of the grade beams. The piers shall be designed based on skin friction acting between the soil and the piers using the design friction value of 450 p.s.f. for dead plus live loads. File No. 16-4006-S American Soil Testing, Inc. 16 A coefficient of friction of 0.30 and a passive pressure equal to an equivalent fluid weighing 250 pounds per cubic foot starting at the top of the lowest adjacent grade can be used. To assure that the passive resistance is developed, the footings either should be poured directly against undisturbed materials 2. The upper 24 inches of pier depth should be ignored when computing skin friction, which is due to seasonal moisture changes in the top layer. 3. The depth and spacing of friction piers will depend upon the structure loads transmitted to the piers and based on the surface friction value. 4. All piers should be reinforced with minimum of four #4 bars for their full length with the reinforcement of the pier tied at least 12 inches to the top reinforcement of the grade beam. The piers should have a minimum spacing of three pier diameters. 5. The grade beam should be found a minimum of 12-inches below adjacent pad grade and should be reinforced with a minimum of four # 4 bars, two near the top and two near the bottom. The steel from the piers should extend sufficient distance into the grade beams to develop its full strength in bond. If the grade beam is to be cast directly on the compacted pad, grade beams should be constructed on a firm, moist sub grade and all drying cracks in the sub grade must be closed by sprinkling, flooding, or other methods. 6. All pier holes should be inspected by our firm representative to ascertain that proper penetration has been achieved, and the supporting soils should not be allowed to dry before the hole is filled with concrete. 7. Should unusual or unexpected soil conditions be encountered, the AST Project Engineer may alter the depth of the piers at time of the construction. 8. At the time of placing of concrete for pier foundation, the pier tops should not be allowed to mushroom out or have spillage at the side of the grade beams, the excess concrete should be trimmed to the design size. File No. 16-4006-S American Soil Testing, Inc. 17 9. The bottoms of the pier should be dry and reasonably free of loose soils prior to installing reinforcing steel and placing concrete. 10. This recommendation is not a substitute for structural design of the friction piers; therefore the final design of the foundations and reinforcing required shall be determined by the Structural Engineer responsible for foundation design. Settlements Since all foundations will be extended into competent materials total and differential settlements under spread and continuous footing are expected to be within tolerable limits. Vertical movements are not expected to exceed 1 inch, and differential movements should be within the normal range (3/4 inch) for the anticipated column spacing and loads. Slight settlements should be considered in the design of foundations and proposed structures File No. 16-4006-S American Soil Testing, Inc. 18 CONCRETE SLABS-ON-GRADE CONSTRUCTION We recommend the following for all slab-on-grade construction: All slab-on-grade shall be supported on a minimum of 6 inches thick capillary break material such as, 3/4” clean crushed rock or permeable aggregate and 2 inches of sand should be used between the finished Sub grade and concrete slab for all interior slabs along with a minimum of 10 mil thick polyethylene or its equivalent vapor membrane which shall be placed between the crushed rock and the sand. Minimum reinforcement should consist of at least #4 rebar, 18 inches on center both ways for shrinkage control to minimize the impact of expansion. However, slab reinforcing could exceed the minimum requirements depending on the anticipated usage and loading conditions. Proper expansion and contraction joints shall be provided in the slab to minimize the cracks in the slab. Concrete slabs around the landscaping area should be protected from water seepage. The water seepage from these areas usually creates over-saturation of the base rock and the sub grade, thereby causing unstable conditions. Henceforth, we recommend the following: Provide vertical cut-off or a deep vertical curb section all along the landscaping areas. The vertical cut-off should extend through the base rock and a minimum of six inches into the sub grade. This will limit the water seepage into the adjacent concrete slabs. Positive surface drainage (minimum 2%) shall provide at all times adjacent to the building to direct water away from the foundations and slabs to suitable discharge facility, during and after the construction phase of the project. If deemed necessary by the Soil Engineer, prior to placing the vapor membrane or pouring concrete, the sub grade shall be moistened with water to reduce the swell potential. The sub grade soils under the slabs area should be water conditioned to File No. 16-4006-S American Soil Testing, Inc. 19 raise the water content; spraying the water at least a day prior the concrete is poured can do this. Minor cracking of the concrete slabs on grade should be anticipated due to long-term differential movement of any underlying fill or natural soil. The project Structural Engineer should be determined the exact thickness and reinforcements based on the design live load and dead load. Garage slab Construction For the slab construction in garages, the slabs should be underlain by a minimum of 12 inches layer of permeable aggregate base or 3/4” clean crushed rock and should be poured structurally independent of the foundations or any fixed members. Expansion joints shall be constructed in the slab at least 10 feet from the interior face of the walls. If deemed necessary by the Soil Engineer, prior to pouring concrete, the sub grade shall be moistened with water to reduce the swell potential. The sub grade soils under the slabs area should be water conditioned to raise the water content; spraying the water at least a day prior the concrete is poured can do this. Minor cracking of the concrete slabs on grade should be anticipated due to long-term differential movement of any underlying fill or natural soil. The project Structural Engineer should be determined the exact thickness and reinforcements based on the design live load and dead load. File No. 16-4006-S American Soil Testing, Inc. 20 RETAINING WALLS 1. Retaining walls (if any) should be designed for a lateral earth pressure (active) of 50 pounds equivalent fluid pressure, plus surcharge loads for sloping surfaces flatter than 4:1. If the retaining walls are restrained from free movement at both ends, or have 3:1 back slopes, they shall be designed for the earth pressure resulting from 65 pounds equivalent fluid pressure, to which shall be added any surcharge loads. 2. The effects of earthquakes my be simulated by applying a horizontal line load surcharge to the stem of the wall at a rate of 18x H² lb/ horizontal foot of wall, where H is the height of the surface of the backfill above the base of the wall. This surcharge should be applied at a height of 0.6 H above the base of the wall. 3. A coefficient of “friction” of 0.30 may be used to calculate the ultimate resistance to horizontal sliding of the wall base over the ground beneath the base. 4. An equivalent fluid pressure of 250 p.s.f./ft may be used to calculate the ultimate passive resistance to lateral movement of the ground in front of the toe of the wall and in front of any “key” beneath the toe or stem of the wall. It is recommended that upslope retaining walls have freeboard to provide catchments for debris flows and minimize the potential for overtopping of the wall surficial slough. Gradient of the back slope Unrestrained equivalent fluid pressure (p.c.f.) Passive Resistance Coefficient of friction Flat to 4:1 50 250 0.30 3:1or Restrained 65 250 0.30 5. The above values assume a drained condition and moisture content compatible with those encountered during our investigation. To promote proper drainage, a File No. 16-4006-S American Soil Testing, Inc. 21 layer of at least 12 inches of ¾” clean crushed rock or drain rock up to ¾ of the height of the wall should be placed between the facility and the retained material. Minimum 4-inch (schedule 40 or better) perforated pipes (perforation down) shall be included in the design to conduct excess water from behind the retaining structure. 6. All retaining walls shall be swale protected with at least a concrete lining. Surface waters shall not be allowed to flow into retaining wall sub drain, to approach the foundation, or to approach the crests. 7. Sub drain placed behind retaining walls should be approved and inspected by American Soil testing representative prior to the placement of fill. 8. The walls should be supported on pier foundations designed in accordance with the recommendations presented previously under Foundation Design criteria. 9. We should have the opportunity for a general review of all designs pertaining to facilities retaining a soil mass prepared for this project. General Construction Requirements 1. Where utility lines cross under or through perimeter footings and sand is used as backfill material, the trench shall be completely sealed by at least 3' concrete plug, to prevent moisture intrusion into the areas under the slabs and/or by compacting soil material for 5 feet on both sides of the exterior footings. 2. Rain water discharge at down spouts must be directed into solid pipe to carry away the excess water and prevent water from collecting in the soil adjacent to the foundation. The connection could be in a closed conduit which discharges at an approved location away from the structure. 3. If utility trenches are parallel to the sides of the building, they should not extend below a line sloping down and away at a 2 to 1(horizontal to vertical) slope from the bottom outside edge of all footings File No. 16-4006-S American Soil Testing, Inc. 22 4. All trenches may be backfilled with the native material provided they are free of organic material and rocks over 4 inches in diameter or with approved imported granular material with the soil compacted to a 95% minimum relative compaction in paved areas and a 90% in other area. Site Drainage In order to prevent water seeping beneath footings, positive surface drainage should be provided at all times. To accomplish this it is recommended that the site be graded to provide for the positive removal of surface water and to prevent ponding, both during and after construction. Where area drains are required, such as in depressed planter beds adjacent to foundation or the edges of slabs, the area drains can be connected to a solid pipe. Sub drain Extensive landscaping may seriously alter the surface drainage pattern. When landscaping, homeowners should avoid disrupting flow patterns created when the property was originally graded. If the building pad should be sub excavated in order to create the crawl space beneath the structure, we recommend that the sub drain be provided and connected to the catch basin or nearest appropriate receptacle. The sub drain shall consist of a 36-inches deep and 12 inches wide trench. A continuous minimum 4- inch diameter perforated plastic pipe (perforations down) shall be graded such that the water will flow toward the catch basin. The pipe should be encapsulated in filter fabric over a minimum of 4 inches of bedding. The trench should be backfilled using maximum 1- inch diameter concrete aggregate or drain rock up to 18 inches, the top portion of the trench should be backfilled by on site soil and compacted to not less than 90% relative compaction. Figure "A" shows schematically the installation of sub drain recommended. A proper outlet should File No. 16-4006-S American Soil Testing, Inc. 23 be provided at the lower end of each segment of sub drain. The outlet should consist of an unperforated pipe of the same diameter, connected to the perforated pipe and extended to a protected outlet at a lower elevation, on a continuous gradient of at least one percent. A cleanout pipe should be provided at the high point of the pipe. A representative of our firm should be present during the sub drain installation, at this time additional recommendations based on exposed field condition and other grading adjustments may be given as deemed necessary by Soil Engineer. 8" 24" 4" 12" 36" Trench cross section Subdrain Detail FIGURE A Native Drain Rock 4" Dia. Perforated pipe with holes down File No. 16-4006-S American Soil Testing, Inc. 24 Plan Review and Observation We should have the opportunity for a general review of the final grading and foundation plans prepared for this project. Our firm should also be retained to provide testing and inspection services during the grading and foundation installation portion of the work. American Soil Testing, Inc. is not responsible for compliance with design recommendations for grading or foundation plans controlled, inspected and approved by others. Conclusions 1. The Site covered by this investigation is suitable for the proposed four single family residences provided the recommendations set forth in this report are incorporated into the design considerations and the project plans and specifications. 2. The native soil with the exception of the organically contaminated surface soil, are suitable for engineered fill. The organically contaminated soil may be used for landscaping only. 3. The native surface and near surface soil at the project site have been found to have low to moderate expansion potential when subjected to fluctuations in moisture. 4. On the bases of our experience during this investigation, it is our opinion that trenches to 5 feet below the existing ground surface do not need shoring. Below 5 feet shoring will be required. File No. 16-4006-S American Soil Testing, Inc. 25 LIMITATIONS AND UNIFORMITY OF CONDITIONS 1. The recommendations presented in this report are based on the soil conditions revealed by our test borings and evaluated for the proposed construction planned at the present time. If any unusual soil conditions are encountered during the construction, or if the proposed construction will differ from that planned at the present time, American Soil Testing, Inc. should be notified immediately for the supplemental recommendations. 2. This report is issued with the understanding that it is the responsibility of the owner, or his representative, to ensure that the recommendations and information contained herein are called to the attention of the Architect, Structural Engineer and Civil Engineer for the project and are incorporated into the Plans and Specifications of project. Also to ensure that the necessary steps are taken to see that the contractors carries out the recommendations of this report in the field. 3. The findings of this report are valid as of the present time. However, the passing of the time will change the conditions of the existing property due to natural processes, or works of man. In addition, legislation or the broadening of knowledge may require other recommendations. Accordingly, the findings of this report may be invalid, wholly or partly, by changes outside of our control. Therefore, this report is subjected to review and should not be relied upon after a period of three years. 4. This report is not a recommendation to purchase or not to purchase the property and shall be for the exclusive use of the client whose name appears above. 5. The conclusions and recommendations contained herein are professional opinions derived in accordance with the current standards of professional practice and no warranty is intended, expressed or implied. File No. 16-4006-S American Soil Testing, Inc. 26 APPENDIX " A " PHYSIOGRAPHY FIGURE 1 VICINITY MAP FIGURE 2 SITE PLAN File No. 16-4006-S American Soil Testing, Inc. 27 FIGURE 1 VICINITY MAP Site File No. 16-4006-S American Soil Testing, Inc. 28 FIGURE 2 SITE PLAN SITE B-3 B-1 B-2 B-4 File No. 16-4006-S American Soil Testing, Inc. 29 APPENDIX " B " SUBSURFACE DATA FIGURE 1-4 Log of test boring FIGURE 5 Plasticity Index FIGURE 6 Key to exploratory boring logs File No. 16-4006-S American Soil Testing, Inc. 30 EXPLORATORY BORING LOG Dated Drilled: 4-13-2016 Hole No. B - 1 Figure No. 1 Project Name: 1323 Parsons Avenue Campbell, California Boring Diameter: 4” Logged by: BR SOIL DESCRIPTION Boring Log Depth in Feet Sampler Number Penetration Resist. Blows/Foot U.S.C.S. Soil -group Moisture Content (%) Dry Density P.C.F. Sandy Silty Clay, light brown, large gravel, dry, firm Sandy Silty Clay, light brown, 2-3” gravel and cobbles, dry, very stiff Sandy Silty Clay, light brown, larger gravel, damp, very stiff Silty Sandy Clay, brown, large gravel damp, very stiff ___________________________________ Boring terminated @ 10’ blg No groundwater encountered 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1-1 1-2 1-3 29 45 51 CL CL/ SC CL/ GC 7.5 9 11.5 104 108 114 File No. 16-4006-S American Soil Testing, Inc. 31 EXPLORATORY BORING LOG Dated Drilled: 4-13-2016 Hole No. B - 2 Figure No. 2 Project Name: 1323 Parsons Avenue Campbell, California Boring Diameter: 4” Logged by: BR SOIL DESCRIPTION Boring Log Depth in Feet Sampler Number Penetration Resist. Blows/Foot U.S.C.S. Soil -group Moisture Content (%) Dry Density P.C.F. Sandy Silty Clay. brown, some organic, damp, firm Sandy Silty Clay, brown, 1-3” dia gravel, dry, very stiff Sandy Silty Clay, light brown, 3”dia. gravel, cobbles, damp, very stiff Gravely Sandy Silty Clay , brown, damp, large cobbles, dense-refusal on gravel ___________________________________ Boring terminated @ 9’ bgl No groundwater encountered 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2-1 2-2 2-3 33 41 50/2” CL CL/ SC No Recovery 9 12 104 109 File No. 16-4006-S American Soil Testing, Inc. 32 EXPLORATORY BORING LOG Dated Drilled: 4-13-2016 Hole No. B - 3 Figure No. 3 Project Name: 1323 Parsons Avenue Campbell, California Boring Diameter: 4” Logged by: BR SOIL DESCRIPTION Boring Log Depth in Feet Sampler Number Penetration Resist. Blows/Foot U.S.C.S. Soil -group Moisture Content (%) Dry Density P.C.F. Sandy Silty Clay, light brown, 1”dia gravel, dry, roots & organic, firm Sandy Silty Clay, light brown, 1-2” gravel and cobbles, dry, very stiff Sandy Silty Clay, light brown, larger gravel, damp, very stiff Silty Sandy Clay, brown, large gravel damp, very stiff ___________________________________ Boring terminated @ 10’ bgl No groundwater encountered 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 3-1 3-2 3-3 29 41 54 CL CL/ SC CL/ GC 11.5 13 11 109 111 114 File No. 16-4006-S American Soil Testing, Inc. 33 EXPLORATORY BORING LOG Dated Drilled: 4-13-2016 Hole No. B - 4 Figure No. 4 Project Name: 1323 Parsons Avenue Campbell, California Boring Diameter: 4” Logged by: BR SOIL DESCRIPTION Boring Log Depth in Feet Sampler Number Penetration Resist. Blows/Foot U.S.C.S. Soil -group Moisture Content (%) Dry Density P.C.F. Sandy Silty Clay, light brown, large gravel, dry, firm Sandy Silty Clay, light brown, 2-3” gravel and cobbles, dry, very stiff Sandy Silty Clay, light brown, larger gravel, damp, very stiff Silty Sandy Clay, brown, large gravel damp, very stiff ___________________________________ Boring terminated @ 10’ bgl No groundwater encountered 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1-1 1-2 1-3 38 48 52 CL CL/ SC CL/ GC 7.5 9 11.5 104 108 112 File No. 16-4006-S American Soil Testing, Inc. 34 PLASTICITY CHART 0 10 20 30 40 50 60 70 80 90 100 LIQUID LIMIT (%) Key Symbol Sample Number Sample depth (ft) Liquid Limit (%) Plasticity Index (%) Unified Soil Classification Symbol B-2-1 1 - 2 34 17 CL Figure 5 PLASTICITY INDEX (%) 50 40 30 20 10 7 4 0 CL CH “A” Line CL or ML ML ML or OL File No. 16-4006-S American Soil Testing, Inc. 35 MAJOR DIVISIONS GROUP SYMBOLS SOIL DESCRIPTION COARSE GRAINED SOILS More than half material is larger than # 200 sieve GRAVELS (More than 50 % material larger than # 4 sieve) CLEAN GRAVEL Less than 5%fines GW Well Graded Gravels, Gravel-Sand Mixtures, little or Fines GP Poorly Graded Gravels or Gravel- Sand Mixtures, little or No Fines GRAVEL With Fines (More than 12% fines) GM Silty Gravels, Gravel-Sand-Silt Mixtures, Non-Plastic Fines. GC Clayey Gravels, Gravel-Sand-Clay Mixtures, Plastic Fines. SANDS (More than 50 % material smaller than # 4 sieve) CLEAN SAND (Less than 5% fines) SW Well Graded Sands, Gravelly Sands, Little or No Fines. SP Poorly Graded Sands or Gravelly Sands, Little or No Fines. SAND With Fines (More than 12% fines) SM Salty Sands, Sand-Silt Mixtures, Non-Plastic Fines. SC Clayey Sands, Sand-Clay Mixtures, Plastic Fines. FINE GRAINED SOILS More than half material is smaller than the #200 sieve SILTS & CLAYS Liquid Limit is less than 50% ML Inorganic Silts, Sandy or Clayey Silts, Low to no Plasticity. CL Inorganic Clay, Sandy or Silty Clay, Low to Medium Plasticity. OL Organic Silt or Organic Silty Clay, Low to Medium Plasticity. SILTS & CLAYS Liquid limit is greater than 50% MH Inorganic Silts, Diatomaceous or Micaceous, Fine Sandy or Silty Soils. CH Inorganic Clays of High Plasticity, Fat Clays. OH Organic Clays of Medium to High Plasticity, Organic Silts. HIGHLY ORGANIC SOILS PT Peat and Other Highly Organic Soils. PARTICLE SIZE LIMITS (Sieve Openings in mm.) .074 .425 2.00 4.17 19.0 75.0 300.0 SILT OR CLAY SAND GRAVEL COBBLES BOULDERS FINE MEDIUM COARSE FINE COARSE (U.S. Standard sieve Sizes) # 200 # 40 # 10 # 4 .75 in 3 in 12 in RELATIVE DENSITY CONSISTENCY SANDS, GRAVELS AND NON- PLASTIC SILTS BLOWS / FOOT * VERY DENSE ERY LOOSE LOOSE MEDIUM DENSE DENSE 0 - 4 4 - 10 10 - 30 30 - 50 OVER 50 CLAYS AND PLASTIC SILTS STRENGTH + BLOWS / FOOT * VERY SOFT SOFT FIRM STIFF VERY STIFF HARD 0 - 1/ 4 1/4 - 1/2 1/2 - 1 1 - 2 2 - 4 OVER 4 0 – 2 2 – 4 4 – 8 8 – 16 16 – 32 OVER 32 * Numbers of blows of 140 pound hammer falling 30 inches to drive a 2-inch O.D. (1 – 3 / 8 inch I. D.) split spoon (ASTM D -1586). + Unconfined compressive strength in tons/sq. ft. as determined by laboratory testing or approximated by the Standard Penetration test (ASTM D – 1586), pocket penetrometer, torvane or visual observation. FIGURE NO. 6 KEY TO EXPLORATORY BORING LOGS UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D-2487) END EXHIBIT 2 PHASE I ENVIRONMENTAL SITE ASSESSMENT IRC Environmental Consulting, LLC www.irc-enviro.com IRC ENVIRONMENTAL CONSULTING, LLC 430 South Fourth Street, San Jose, CA 95112 (408) 313 - 9376 ircenvironmental@gmail.com PHASE I ENVIRONMENTAL SITE ASSESSMENT REPORT 1323 Parsons Avenue Campbell, California April 20, 2016 Project Number 3325 Prepared For The Ridgecrest Group 12280 Saratoga Sunnyvale Road, Suite 109 Saratoga, CA 95070 Prepared By IRC Environmental Consulting, LLC 430 South 4th Street San Jose, California 95112-5730 (408) 313 - 9376 ircenvironmental@gmail.com IRC Environmental Consulting, LLC www.irc-enviro.com IRC ENVIRONMENTAL CONSULTING, LLC 430 South 4th Street, San Jose, CA 95112-5730 (408) 313 - 9376 ircenvironmental@gmail.com April 20, 2016 Project Number 3325 The Ridgecrest Group 12280 Saratoga Sunnyvale Road, Suite 109 Saratoga, Ca 95070 Via Email to: omidshakeri@comcast.net Attn: Omid Shakeri Subject: PHASE I ENVIRONMENTAL SITE ASSESSMENT REPORT SITE: 1323 PARSONS AVENUE, CAMPBELL, CALIFORNIA SANTA CLARA COUNTY ASSESSOR’S PARCEL NUMBER (APN): 414 - 37 - 008 (Book 414, Page 37, Parcel 008) Dear Mr. Shakeri: IRC is pleased to present the accompanying final report of the Phase I Environmental Site Assessment (ESA) prepared for the subject Site. IRC appreciates the opportunity to have been of service. Should you have any questions or require additional information or services please contact me at (408) 313 - 9376 or ircenvironmental@gmail.com. Sincerely, Benjamin Berman Project Manager IRC Environmental Consulting, LLC (IRC) TABLE OF CONTENTS 1.0 EXECUTIVE SUMMARY, CONCLUSIONS, RECOMMENDATIONS 1 2.0 PURPOSE AND SCOPE 4 2.1 Purpose ................................................................................................ 4 2.2 Scope of Services ................................................................................ 4 2.3 Limitations ............................................................................................ 5 3.0 PHYSICAL AND ENVIRONMENTAL SETTING 6 3.1 Topography .......................................................................................... 6 3.2 Regional Geology ................................................................................. 6 4.0 LAND USE HISTORY 7 4.1 Historical Topographic Maps ................................................................ 7 4.2 Review of Aerial Photographs .............................................................. 7 4.3 Historical Fire Insurance Maps ............................................................. 8 4.4 City Directories ..................................................................................... 8 4.5 User Provided Data, Data From Non-Public Sources, Questionnaire, Interviews ..................................................................... 9 5.0 SITE RECONNAISSANCE 10 5.1 Site Description and General Observations ....................................... 10 5.2 Additional Non-Scope Services .......................................................... 10 5.3 Adjoining and Neighboring Properties Description ............................. 11 6.0 RECORDS AND CORRESPONDENCE REVIEW 12 6.1 Federal and State Records Sources .................................................. 12 6.2 Contamination Migration .................................................................... 13 6.3 Summary of Radius Map Report Findings .......................................... 14 6.4 Environmental Liens and Activity and Use Limitations ....................... 14 6.5 Summary of State and Local Agency Records and Correspondence 14 6.6 Data Gaps and Data Failure ............................................................... 16 7.0 SIGNATURES OF ENVIRONMENTAL PROFESSIONALS 17 8.0 REFERENCES 18 FIGURES FIGURE 1 SITE LOCATION & VICINITY MAP, TOPOGRAPHIC BASE FIGURE 2 SUBJECT SITE AND ADJACENT PROPERTIES, GOOGLE EARTH IMAGE FIGURE 3 SUBJECT SITE, GOOGLE EARTH IMAGE FIGURE 4 SUBJECT SITE FEATURES TABLES TABLE 1 SUMMARY OF AERIAL PHOTOGRAPH REVIEWS TABLE 2 SUMMARY OF CITY DIRECTORIES REVIEWS PHTOGRAPHS PHOTOGRAPHS SITE PHOTOGRAPHS (SUBJECT PROPERTY) APPENDICES (ON CD) APPENDIX A STATEMENT OF QUALIFICATIONS APPENDIX B HISTORICAL TOPOGRAPHIC MAPS APPENDIX C CITY DIRECTORIES APPENDIX D AERIAL PHOTOGRAPHS APPENDIX E SANBORN MAPS APPENDIX F ENVIRONMENTAL LIEN SEARCH APPENDIX G RADIUS MAP REPORT APPENDIX H PHYSICAL SETTINGS MAPS APPENDIX I WATER WELL REPORT APPENDIX J OIL & GAS REPORT APPENDIX K WEST VALLEY SANITATION DISTRICT Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 1 1.0 EXECUTIVE SUMMARY, CONCLUSIONS, RECOMMENDATIONS IRC Environmental Consulting (IRC) has completed a Phase I Environmental Site Assessment (ESA) of the property located at address 1323 Parsons Avenue, Campbell, California (referred to hereinafter as the Site, subject Site, or subject property). This Site assessment was prepared for The Ridgecrest Group in April 2016. This assessment included the visual survey of the Site, exterior inspection of immediately adjacent properties, review of historical documentation, review of local agency files specific to the Site, and a review of regulatory databases that identify nearby sites of potential environmental concern. The purpose of this assessment was to evaluate the Site for real and potential environmental impairments, or risks of impairments, that may represent existing or potential financial and legal liabilities to The Ridgecrest Group and / or their agents. Based on our review of available records, site inspection, and / or interviews, no Recognized Environmental Conditions (RECs) were identified. Business Environmental Risks and Non- Scope Considerations were identified. See below for details. Findings, Opinions Subject Property, Location, Description, Current Uses The subject property is identified as Santa Clara County Assessor's Parcel Number 414-37-008, and is associated with 1323 Parsons Avenue, Santa Clara County, in the City of Campbell, California. The property consists of a +/- 0.75 acre parcel of land developed with one single family residence proximate to Parsons Avenue. The majority of the land area of the subject property consists of a large undeveloped back yard. Subject Property, Historical Uses Review of available information indicated that the subject property was primarily undeveloped or agricultural (orchards) by the 1930s and remained agricultural into the 1950s. The house on the subject property was constructed circa 1950 and the original sewer connection permit was issued in 1958. Adjacent Properties, Historical and Current Uses Adjoining / surrounding properties were primarily undeveloped / agricultural (orchards) by the 1930s and were mostly all developed by the 1960s for commercial and residential uses. The immediately adjoining property to the east at 1387 Camden Avenue was formally a gasoline service station and is currently a Jiffy Lube (automotive oil change shop). There are several other historical and current gasoline service stations and current automotive repair shops in the immediately surrounding area. Subject Property, Potential Concerns Originating from Onsite No Recognized Environmental Conditions (RECs) originating from onsite were identified. Potential Business Environmental Risks and Non-Scope Considerations were identified (see below). Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 2 Adjoining / Nearby Properties, Potential Concerns No Recognized Environmental Conditions (RECs) originating from adjoining / nearby sites were identified. However, the immediately adjoining property to the east at 1387 Camden Avenue was formally a gasoline service station and is currently a Jiffy Lube (automotive oil change shop). Three gasoline underground storage tanks (USTs) and gasoline impacted soil were removed from the 1387 Camden Avenue site in 1988. A leaking underground storage tank (LUST) case was opened, subsurface sampling investigations were conducted circa 1997 - 2003 and groundwater sampling and monitoring was conducted circa 2003 - 2013. Soil and groundwater sample results at locations proximate to the subject property were almost all below laboratory detection / reporting limits other than a few low trace level detections. Thus it does not appear likely that there would be soil gas / vapor transmission to the subject property of sufficient magnitude to create a significant environmental concern. In our opinion the likelihood of significant impact to the subject property is low. The LUST case was closed (granted no further action) in December 2015. Although not identified as a REC for the subject property, the 1387 Camden Avenue site is considered a Business Environmental Risk for the subject property (see below). Business Environmental Risk The immediately adjoining property at 1387 Camden Avenue was a former gasoline service station and LUST case and is currently used for automotive purposes (Jiffy Lube). Automotive use is associated with use, storage and generation of hazardous materials / wastes such as new and used motor oil, solvents, and other substances. The current Jiffy Lube has a basement / underground pit used to facilitate work on cars and may have an aboveground used oil tank. These conditions have been identified as potential Business Environmental Risks for the subject property, although neither the pit nor the aboveground tank (if currently exists) are likely to result in a significant environmental risk for the subject property. In our opinion the likelihood of significant impact to the subject property is low. The subject property was historically agricultural (orchards) and it is possible that residual pesticides or other substances associated with agricultural use might remain in the subject property soils / subsurface. Non-Scope Considerations • There may be a potential for vapor intrusion into structures on the subject property from off-site sources, although in our opinion the likelihood of significant impact to the subject property is low. • Given the age of the residence on the subject property (circa 1950) it is possible that Asbestos Containing Building Materials (ACBM) may have been used in construction and / or Lead-Based Paint (LBP) may have been used on painted surfaces. • The residence on the subject property was built circa 1950 and the original sewer connection permit was issued in 1958. It is unknown although likely that there was a functioning septic system on the subject property, and assuming there was at one time a septic system, it is unknown whether or not it was ever removed. Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 3 Conclusions IRC Environmental Consulting, LLC has performed a Phase I Environmental Site Assessment in conformance with the scope and limitations of ASTM Standard Practice E 1527 of 1323 Parsons Avenue in the City of Campbell, California, the property. Any exceptions to, or deletions from, this practice are described in Section 2.0 of this report. This assessment has revealed no evidence of recognized environmental conditions in connection with the property. However, the following should be considered: • Potential Business Environmental Risks and Non-Scope Considerations were identified (see above). Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 4 2.0 PURPOSE AND SCOPE This report presents the results, conclusions, and recommendations from the Phase I Environmental Site Assessment (ESA) for the property located at 1323 Parsons Avenue in the City of Campbell, California (hereinafter referred to as the “Site”, “subject Site”, or “subject property”). 2.1 Purpose The purpose of this investigation was to conduct an environmental assessment that would address real and potential environmental impairments, or risks of impairments, that may represent financial and legal liabilities to The Ridgecrest Group and / or their agents. IRC assumes the purpose of this ESA is to qualify for Landowner Liability Protections (LLP) to Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) liability, to understand potential environmental conditions that could materially impact the operation of the business(es) associated with the parcel(s) of commercial real estate, and / or for other purposes associated with business environmental risk (we were not informed of any other purpose). 2.2 Scope of Services The Scope of Services for the performance of this Phase I ESA included the following tasks: ♦ Research and review available geologic and hydrogeologic information concerning the Site and its environment. ♦ Review available historical documentation of the property to determine what activities have occurred at the Site and immediately adjacent sites since the Site’s first developed use or since 1940 (whichever is earlier). ♦ Generally survey current uses of immediately adjacent properties. ♦ Inspect the Site to determine current on-Site activities and past uses. ♦ Review available files / records, request public records, submit an inquiry to, and or obtain online information from the following state or local regulatory agencies for the subject Site address(es): • State / Regional Water Quality Control Board (S/RWQCB) • Santa Clara Valley Water District (SCVWD) • Santa Clara County Department of Environmental Health (SCCDEH) • Santa Clara County Fire Department (SCCFD) • West Valley Sanitation District (WVSD) • City of Campbell (COC) • Santa Clara County Assessor’s Office (SCCAO) ♦ Acquire a review of federal, state and county publications (radius report) to identify the Site and nearby sites (if any) included on more than 50 databases, including (but not limited to) the following databases or current equivalents: • National Priority List (NPL) Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 5 • Resource Conservation and Recovery Act (RCRAInfo) • Region 9, Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) • RCRA Treatment, Storage and Disposal (TSD) Facilities • Emergency Response Notification System (ERNS) • Leaking Underground Storage Tanks (LUST) sites • Registered underground storage tank (UST) sites ♦ Review available reports concerning on-going investigations at nearby agency-listed sites. ♦ Prepare this report in general accordance with the document entitled Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessments Process (The American Society for Testing and Materials [ASTM], E 1527-13). 2.3 Limitations Assessments are performed on subject property identification information (street addresses and parcel numbers) provided by the client / user at the initiation and authorization of the work. The conclusions of this report are based solely on the Scope of Services outlined above, and on the sources of information referenced in this report. Any additional information that becomes available concerning this Site should be submitted to IRC Environmental Consulting so that our conclusions may be reviewed and modified, if necessary. Conducting environmental sampling (i.e. soil, groundwater, vapor / air, building materials) is outside the scope of this Phase 1 ESA. Other Non-scope considerations outside the scope of this Phase 1 ESA include, but are not limited to, considerations such as the following: screening for the possibility of vapor intrusion into buildings or structures, indoor air quality, asbestos containing building materials, lead-based paint, mold, radon, and wetlands. Note regarding potential vapor intrusion / indoor air quality; the possibility of / potential for subsurface contaminant migration via subsurface vapor, along with potential contaminant migration in subsurface soil and groundwater, are considered as part of this Phase I ESA. The accompanying report presents a description of the work performed by IRC Environmental Consulting and was prepared using guidelines presented in the document entitled, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process (The American Society for Testing and Materials [ASTM], E 1527-13). Note that all limitations in ASTM E 1527-13 apply, such as those in sections 4.5.1 through 4.5.4 (and other sections), and user’s responsibilities in ASTM E 1527-13 apply (section 6). It should be noted that this report has been prepared to generally accepted industry standards and may need to be modified to meet specific lender requirements. This document has been prepared according to generally accepted practices. No other warranty, either expressed or implied as to the methods, results, conclusions or recommendations is made. The user is notified that uncertainty is not eliminated, assessments are not exhaustive, reasonable time and cost constraints and other limitations are inherent, certain conditions may not be detected during an assessment of this type, and no level of assessment can guarantee that a site is completely free of hazardous substances. This assessment was based on a specific scope of work with a defined budget, was not intended to be comprehensive, identify all potential concerns, or eliminate the possibility of any environmental impacts to the subject property. The results of all assessments are subject to Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 6 differing professional interpretations and opinions, the conclusions of others may differ. If you wish to reduce the level of uncertainty associated with this study, we should be contacted for additional consultation. Regulatory agency environmental regulations, priorities, and enforcement change over time and tend to get stricter / more conservative; potential impacts previously unknown or of little concern, such as but not limited to vapor intrusion, tend to become more important environmental regulatory concerns over time. The findings, analysis, opinions, conclusions and recommendations contained in this report are based on site conditions as they existed at the time of our assessment and review of practically reviewable information relevant to the site conditions that was reasonably available and ascertainable at the time of this assessment. Changes in the information or data gained from any of these sources could result in changes in our conclusions or recommendations. If such changes do occur, we should be advised so that we can review our report in light of those changes. This assessment and report are for the sole use of the client, reliance upon the information in this report by others is solely at their own risk. Nothing in this report shall be construed as a legal opinion, this assessment / report may be based in part upon verbal or written information possessed by the client / user or other non-public privately owned information, and all of IRC Environmental Consulting LLC’s Standard Terms and Conditions and Limitations apply at all times to this report and all reports by IRC Environmental Consulting. 3.0 PHYSICAL AND ENVIRONMENTAL SETTING 3.1 Topography The Site's physical location was researched employing the current United States Geological Survey (USGS) 7.5-Minute Topographic Quadrangle Map section relevant to the Site. The 7.5- Minute Map has an approximate scale of 1 inch to 24,000 inches, and shows physical features such as wetlands, water bodies, railways and roadways, mines, wells, and buildings. The physical and natural features illustrated on the topographic map serve as areas of visual emphasis to note when conducting the on-Site visit. The San Jose West Quadrangle Topographic Map (dated 1961, photo-revised in 1980) shows no physical features that would likely environmentally impact the Site. The map reveals no storage tanks, mines, or wells in the immediate area. This topographic map shows the elevation of the Site to be approximately 225 to 230 feet above mean sea level with an approximate northeasterly topographic gradient direction. Los Gatos Creek lies approximately 0.2 miles west of the subject property (the creek is located immediately west of and proximate to State Highway 17). 3.2 Regional Geology Soils and geology in the vicinity of the subject property are included in Appendix H, Physical Settings Maps. The geology map / report in Appendix H includes the following information from the United States Geological Survey (USGS): • Geology Symbol: Q; Unit Name: Quaternary Alluvium and Marine Deposits; • Unit Description: Alluvium, lake, playa, and terrace deposits, unconsolidated and semi-consolidated. Mostly non-marine, but includes marine deposits near the coast; and • Rocktype/s: Alluvium; Terrace; Lake Or Marine Deposit (Non-Glacial). Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 7 4.0 LAND USE HISTORY A review of readily available, standard historical sources (as defined in ASTM E 1527-13) was performed to assist in establishing any significant past uses of the Site and immediately adjacent properties. The review attempted (to the extent of readily available sources) to encompass the years since the first obvious developed use of the Site, or since 1940, whichever is earlier. The following subsections present a summary of our findings from our review of each source. Review of available building and fire department records, city directories, historical aerial photographs, historical topographic maps, interviews and / or other information indicated that the subject Site was primarily undeveloped or agricultural (orchards) by the 1930s and remained agricultural into the 1950s. The house on the subject property was constructed circa 1950 and the original sewer connection permit was issued in 1958. Adjoining / surrounding properties were primarily undeveloped / agricultural (orchards) by the 1930s and were mostly all developed by the 1960s for commercial and residential uses. 4.1 Historical Topographic Maps Historical Topographic Maps from 1899, 1943, 1953, 1961, 1968, 1973, 1980 and 2012 were reviewed. The Topographic Maps from 1968, 1973, and 1980 were photo revised from the 1961 map. The scale, resolution and / or quality of the 1899 map was inadequate to reliably determine the location / details in the vicinity of the subject property. The 1943 and 1953 maps appeared to show the subject property and vicinity as agricultural / orchards. The 1961 through 2012 maps showed the subject property and vicinity as within the area of urban / suburban development. Historical Topographic Maps are presented in Appendix B. 4.2 Review of Aerial Photographs Historical aerial photographs supplied by GeoSearch were reviewed to help evaluate past land uses on the Site and surrounding properties. In addition, the photographs were reviewed for evidence of hazardous materials and features that may have impacted the Site and general vicinity. These features may have included, but were not limited to, landfills, ponds, pits, staining or distressed vegetation, aboveground storage tanks, lagoons, exterior storage of hazardous materials, and general land use practices. Aerial photographs taken in 1939, 1948, 1956, 1960, 1968, 1974, 1982, 1987, 1993, 2003 and 2014 were reviewed (Appendix D). A summary of aerial photography review is provided in Table 1 in the Tables section. Limited additional useable information was obtained from the aerial photography review, partially due to the general poor quality of the 1974, 1982, 1987 and 2003 photographs and partially because some of the same information was obtained from the historical topographic maps. The 1939, 1948, and 1956 photographs show the subject property and adjoining properties as agricultural (orchards). The house on the subject property did not appear evident on the 1956 or earlier photographs; it did appear on the 1960 and subsequent photographs (other information indicated the house was built circa 1950). The adjoining property at 1387 Camden Avenue (current Jiffy Lube) had three different structures, each replacing the previous, in the 1956, 1968 ("L" shaped building, possible gas station?), and 1993 photographs (current Jiffy Lube building). Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 8 4.3 Historical Fire Insurance Maps Fire Insurance Maps (FIM) / fire maps produced by the Sanborn Fire Insurance Company for major cities and towns depict structures, building materials, uses, USTs, gas lines, etc. These maps were typically produced beginning prior to 1900 and were often updated into the 1970s. These maps are valuable sources of information in determining prior usage, provided the site's location is within city limits as they were defined in the early to mid-1900s. The results of the FIM / Sanborn Map search are presented in Appendix E. The subject Site at 1323 Parsons Avenue did not have FIM / Sanborn map coverage, indicating that there was no urban development at the site during the period of coverage. 4.4 City Directories City directories have been published for major cities and towns across the United States since the 19th century. City directories published in the 20th century also included a street index for each street address during a given year. City directories are a valuable source of historical information with regard to Site tenancy and use. IRC reviewed city directories as provided by GeoSearch for the subject Site address(es) (Appendix C). Information is provided in Table 2, in the Tables section, for those years where city directory information for the subject property (and adjoining and nearby properties) was found. For the subject property the city directories appeared to list the name of the individual property owner / occupant from circa 1970 to 2007 (George Slough). For the immediately adjoining site to the east at 1387 Camden Avenue (current Jiffy Lube), the city directories listed a gas station from circa 1970 to 1980, automotive in 1985, and Jiffy Lube from circa 1990 to 2002. Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 9 4.5 User Provided Data, Data from Non-Public Sources, Questionnaire, Interviews During this Phase I Environmental Site Assessment no previous reports on the subject Site property of significant relevance to the performance of this Phase I Environmental Site Assessment were made available for our review by Site contacts, potential users of this Phase I Environmental Site Assessment, or other non-public sources of information. The users did provide a title report and drawings of existing Site and planned new development of four new single-family residences. Questionnaire IRC’s standard Phase I assessment Questionnaire, which includes questions in accordance with the ASTM Standard Practice E 1527-13, was completed on March 22, 2016 by Mr. John Maesumi of The Ridgecrest Group, the current owners planning re-development of the subject property. Little or no additional information was obtained from the completed questionnaire that was not available or already obtained from other sources. The completed questionnaire indicated that the existing single-family house on the subject property was constructed circa 1950. Interviews Except where indicated otherwise all interviews were conducted via telephone by Mr. Benjamin Berman of IRC. On April 7 , 2016, an in-person interview was conducted with the tenant, Mario, during the Site inspection. Mario indicated the following. He has lived with his family in the house on the subject property for about two years; he has no knowledge of the previous occupants. He built all the wooden bicycle ramps on the subject property, they were used for bicycles only (not motorcycles). The motorcycles are stored, no repair or maintenance activities are performed on the motorcycles. He has no knowledge of any past or present storage, use or generation of hazardous materials / wastes or other toxic substances, underground or aboveground storage tanks, spills, leaks or releases on the subject property or adjoining properties. He has not encountered any concern with the adjoining Jiffy Lube auto oil change shop. Various county and city public agencies were contacted by email and telephone in March and April 2016, see section 6.5. Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 10 5.0 SITE RECONNAISSANCE Benjamin Berman of IRC Environmental Consulting, conducted a Site visit and inspection on April 7, 2016. Mr. Berman was unaccompanied during the Site inspection. All observations are valid as of the date of the Site inspection. 5.1 Site Description and General Observations A Site Location & Vicinity Map (on topographic base, Figure 1), Subject Site and Adjacent Properties – Google Earth Image™ (Figure 2), Subject Site – Google Earth Image™ (Figure 3), and Subject Site Features (Figure 4) are provided in the Figures section of this report. Site photographs (and photographic notes) are provided in the Photographs section of this report. Figure 4 shows the approximate locations and directions of the photographs. The Site is identified as Santa Clara County Assessor's Parcel Number 414-37-008, and is associated with 1323 Parsons Avenue, Santa Clara County, in the City of Campbell, California. The property consists of a +/- 0.75 acre parcel of land developed with one single family residence proximate to Parsons Avenue. The majority of the land area of the subject property consists of a large undeveloped back lot yard. At the time of the Site inspection the house on the subject property was occupied by a tenant. The user should note that much of the ground surface of the subject property was not visible due to vegetation. Exterior Observations (see Figure 4 and Photographic Notes / Photographs) • A pole mounted transformer was observed near the front of the subject property proximate to Parsons Avenue (Photograph No. 1). Note that electrical transformers typically contain petroleum-based cooling oil, which is a potential source of contamination if a spill, leak, or other release occurs. The transformer cooling oil may contain PCBs (another potential contaminant), although PCBs have been removed from most utility owned transformers in California. No obvious signs of a leak, such as stained soil, were observed. • Two storage sheds were observed containing empty 1 to 2 gallon gas containers, one 1-gallon container of oil and gas for a lawn mower, fertilizers and gardening tools (Photographs No. 16 and 17). Soil in the vicinity of the sheds was not visible due to vegetation. • Approximately a half dozen motorcycles were stored on an unpaved surface (Photograph No. 18). No soil staining was observed. Interior Observations • No items of concern were observed inside the house. 5.2 Additional Non-Scope Services No additional non-scope services were performed as part of this Phase I ESA and no detailed observations / investigation of non-scope conditions was made. However, with regards to Non-Scope Considerations, the following should be noted with regards to Asbestos Containing Building Materials (ACBM) and Lead-Based Paint (LBP). Given the age of the residence on the subject property (circa 1950) it is possible that ACBM may have been used in construction and / or LBP may have been used on painted surfaces. Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 11 5.3 Adjoining and Neighboring Properties Description See Figure 2, Subject Site and Adjacent Properties. IRC performed a limited visual inspection of immediately adjoining properties to evaluate their potential environmental significance to the Site. The properties immediately adjoining / surrounding the Site include the Jiffy Lube at 1387 Camden Avenue immediately east of and adjoining the subject property. The 1387 Camden Avenue site is a former gasoline service station and a former leaking underground storage tank (LUST) site (see section 6.5, S/RWQCB for more information about this site). Several other gasoline service stations and automotive repair shops were observed nearby (Figure 2). These sites are of potential environmental concern for the subject property (see section 6.3 for more information). Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 12 6.0 RECORDS AND CORRESPONDENCE REVIEW To further evaluate potential sources of contamination originating from on and/or off-site sources, a review of published agency documents, agency files, and other pertinent documents was performed. Generally, information regarding potential off-site sources is obtained from federal and state agency listings, while local agencies offer more site-specific information. 6.1 Federal and State Records Sources IRC Environmental Consulting contracted with GeoSearch for the performance of an environmental database search to identify agency-listed sites of potential environmental significance located within a one-mile radius of the Site. The GeoSearch Radius Map report is presented in Appendix G. The GeoSearch radius report identifies sites on more than 50 databases including all or most of the following or equivalent / current categories: NPL: National Priority List (Federal Superfund Sites) CERCLIS/NFRAP: EPA State Superfund Sites CORRACTS: EPA Corrective action facilities RCRA GEN: Small and large quantity generators of hazardous waste ERNS: Emergency Response Notification System Sites HMIRS: Hazardous Materials Information Reporting System TRIS: Toxic Release Inventory System TSCA: Toxic Substance Control Act FTTS: Federal Insecticide, Fungicide, & Rodenticide Act/TSCA SSTS: Section 7 Tracking System PADS: PCB Activity Database System MLTS: Material Licensing Tracking System MINES: Mines Master Index File FINDS: Facility Index System RAATS: RCRA Administrative Action Tracking System CAL-SITES: Potential or confirmed hazardous release properties REF: Unconfirmed Properties Referred to Another Agency LUST: Sites with Leaking Underground Storage Tanks SWLF/State Landfill: Permitted solid waste State landfills, incinerators, or transfer stations DEED: Deed restriction sites CORTESE: Hazardous Waste Substance Sites TOXIC Pits: Toxic pits cleanup facilities UST/AST: Registered Underground or Aboveground Storage Tank Sites CHMIRS: California Hazardous Materials Information Reporting System CA WDS: Waste Discharge System CA SLIC: Statewide Spills, Leaks, Investigations and Cleanups SWEEPS UST: Statewide Environmental Evaluation and Planning System NOTIFY 65: Proposition 65 Records DRYCLEANERS: Drycleaner related facilities with EPA ID numbers HAZNET: Facility and Manifest Data EMI: Emissions Inventory Data Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 13 6.2 Contamination Migration Fuel Leak Attenuation In fuel leak cases, research conducted at the Lawrence Livermore National Laboratory (LLNL) indicates that attenuation and degradation play major roles in reducing hydrocarbon contamination in groundwater to non-detectable levels within several hundred feet of the contaminant source. Moreover, this research indicates that in over 90% of the petroleum hydrocarbon contamination cases, groundwater contaminant plumes do not extend more than 250-feet from the source; however, a gasoline additive called Methyl Tertiary Butyl Ether (MTBE) has been found to be more mobile in groundwater compared to gasoline and gasoline break-down products. Findings indicate that MTBE is highly soluble in water and moves easily through soil particles and into groundwater where it may spread over a distance greater than 250 feet. MTBE will transfer to groundwater from gasoline leaking from USTs, pipelines, car emissions into the atmosphere, and other components of gasoline vapor distribution. MTBE has been an additive to gasoline since approximately 1985. Toxic-Leak Attenuation In the case of toxic substances in the groundwater, namely the more mobile Volatile Organic Compounds (VOCs), detectable levels may extend several thousand feet or more from the source. In most VOC groundwater plume cases, however, attenuation will act to reduce the contamination to non-detectable levels within one-half mile of the source. Groundwater Flow Site-specific information on groundwater flow direction, depth and quality can only be confirmed through the installation and survey of a minimum of three on-Site or near Site groundwater- monitoring wells for measuring depth to groundwater. No indication was found that groundwater monitoring wells ever existed on the subject Site, however, there were groundwater monitoring wells on the immediately adjoining site at 1387 Camden Avenue (current Jiffy Lube) (CR&A, October 30, 2013). Data from former groundwater monitoring wells at the 1387 Camden Avenue site from circa 2003 to 2013 indicated groundwater ranging in depth from approximately 44 to 68 feet below the ground surface (bgs) with two predominate groundwater flow directions, towards the east - southeast and towards the south-southwest. Additional information from groundwater monitoring wells from circa 2001 to 2013 was found for a gas station site at 1370 Camden Avenue, Campbell, California, located approximately 150 feet northeast of the subject property (Horizon, June 26, 2013). Data from the 1370 Camden Avenue site indicated perched (seasonal) shallow groundwater ranging in depth from approximately 34 to 49 feet bgs (A zone) and from approximately 54 to 62 feet bgs (B zone) with no definitive groundwater flow direction (variable groundwater flow directions). Shallow regional groundwater flow directions can typically be assumed to follow topographic gradients. The San Jose West Quadrangle Topographic Map (dated 1961, photo-revised in 1980) shows an approximate topographic gradient direction to the northeast in the vicinity of the subject property. It should be noted that groundwater flow directions and depths are variable and subject to site-specific influences, such as groundwater pumping, and perched / seasonal groundwater may occur. Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 14 6.3 Summary of Radius Map Report Findings The GeoSearch Radius Map Report is presented in Appendix G. The subject property was not identified in any database searches in the GeoSearch Radius Report. A review of the radius report indicated several leaking underground storage tank (LUST) sites in the surrounding area, including at an immediately adjoining site to the east (1387 Camden Avenue, current Jiffy Lube, see section 6.5 (S/RWQCB) for more information about this site). The listed sites were typically for former underground storage tanks (USTs) containing gasoline or other fuels / petroleum hydrocarbons. IRC concludes that based on the media affected (e.g. soil only), the substance released (e.g. petroleum hydrocarbons), distances from the subject Site, the age of the releases, the regulatory / cleanup status, the inferred down / cross gradient orientation (with regards to groundwater flow) relative to the subject Site, and / or other potential ‘de minimus’ condition (ASTM, November 1, 2005 [Section 1.1.1]), the likelihood that the subject Site is impacted at levels of regulatory concern by these listed sites is low. These former offsite releases have not been determined to be a Recognized Environmental Conditions (RECs) for the subject property. However, the user is cautioned that the former subsurface releases from one or more of the listed sites have the potential to adversely impact the subject property; therefore, these offsite releases are considered to be business environmental risks for the subject property, although in our opinion the likelihood of significant impact is low. 6.4 Environmental Liens and Activity and Use Limitations An environmental lien search provided by GeoSearch indicated environmental liens for the subject Site were “Not Found”. The lien search report can be found in Appendix F. 6.5 Summary of State and Local Agency Records and Correspondence During the review of standard environmental records, IRC Environmental Consulting used the following information sources: • State / Regional Water Quality Control Board (S/RWQCB) • Santa Clara Valley Water District (SCVWD) • Santa Clara County Department of Environmental Health (SCCDEH) • Santa Clara County Fire Department (SCCFD) • West Valley Sanitation District (WVSD) • City of Campbell (COC) • Santa Clara County Assessor’s Office (SCCAO) Synopses of records and correspondence reviewed for the Site at the following agencies are presented below: State / Regional Water Quality Control Board (S/RWQCB) / GeoTracker IRC Environmental Consulting searched the S/RWQCB GeoTracker online files on March 29, 2016, for information regarding Leaking Underground Storage Tanks (LUSTs) and hazardous Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 15 materials spills or other potential concerns that may significantly adversely affect the subsurface of the subject Site. No records were found for the subject property. Online files were found for the immediately adjoining site to the east, the current Jiffy Lube at 1387 Camden Avenue, Campbell, California (CR&A, January 11 and October 30, 2013 and SCCDEH, July 10, 2014). The 1387 Camden Avenue site was formally a gasoline service station, three gasoline underground storage tanks (USTs) and gasoline impacted soil were removed from the site in 1988. A leaking underground storage tank (LUST) case was opened under the local oversight of the Santa Clara County Department of Environmental Health (SCCDEH). Subsurface sampling investigations were conducted circa 1997 - 2003 and groundwater sampling and monitoring was conducted circa 2003 - 2013. Samples were typically analyzed for the constituents of concern including total petroleum hydrocarbons as gasoline (TPHG), benzene, toluene, ethyl benzene, and total xylenes (BTEX compounds) and methyl tert butyl ethane (MTBE). Soil and groundwater sample results at locations proximate to the subject property were almost all below laboratory detection / reporting limits other than a few low trace level detections. The LUST case was closed (granted no further action) in December 2015. No additional items indicating potential significant environmental concerns for the subject property were identified from S/RWQCB reviews. Information was found for one other site in the surrounding area, from which regional shallow groundwater flow directional information was obtained: see section 6.2, Groundwater Flow. Santa Clara Valley Water District (SCVWD) IRC contacted the SCVWD by email on March 23, 2016 to inquire if there are any records indicating the existence of wells on the subject property; the SCVWD indicated that there are no registered wells on those addresses (parcels). During the Site inspection no wells were observed on the subject property. Santa Clara County Department of Environmental Health (SCCDEH) IRC submitted an email request for public records for the subject property and adjoining property (Jiffy Lube, 1387 Camden Avenue) on March 23, 2016; the SCCDEH indicated by email that they do not have records for the subject property. Various records were provided for the Jiffy Lube at 1387 Camden Avenue. These consisted of hazardous materials (hazmat) and hazardous waste (hazwaste) related documents from circa 1990s to 2015 for substances such as new and used motor oil, including permits and inspection records. Records indicated a 1,000 gallon aboveground used oil tank and a basement used for going below cars while changing oil / automotive fluids. There were various correctable violations such as for record keeping, labeling, secondary containment and training. Nothing was found indicating a significant spill or other release. Santa Clara County Fire Department (SCCFD) City of Campbell fire department activities and records, notably for those functions covering areas such as hazardous materials (hazmat) and underground storage tank (UST) regulation, are typically handled by the SCCFD or SCCDEH (see above). IRC submitted a request for public records by email for the subject property and adjoining property (Jiffy Lube, 1387 Camden Avenue) on March 23, 2016. SCCFD indicated by email that they do not have records Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 16 for the subject property. They did have records for the Jiffy Lube at 1387 Camden Avenue. Accessing the paper records would have required a walk-in file review. After speaking with SCCFD staff it became apparent that the records were likely mostly the same as what was provided by the SCCDEH (see above). Therefore the SCCFD records for 1387 Camden Avenue were not reviewed. West Valley Sanitation District (WVSD) IRC submitted a request for public records by email for the subject property on April 6, 2016. The WVSD provided information by email (presented in Appendix K). The WVSD indicated the following. County records indicate the house was built in 1950. The original sewer connection permit for the subject property was issued on February 28, 1958. The subject property's previous APN was 413-23-003 (current APN is 414-37-008). The WVSD does not know if this parcel was previously discharging into a septic system. City of Campbell (COC) On March 22, 2016, IRC performed an online records / building permits review for the subject property and adjoining property at 1387 Camden Avenue (Jiffy Lube). Online available information is very limited, consisting of a simple list in table format with two columns, Case Number (permit, document number) on the left and a very brief description on the right; the actual permits / documents are not available for viewing online. Nothing was found for the subject property and adjoining property addresses indicating a potential significant environmental concern for the subject property. On March 22, 2016, IRC sent email requests for public records to the following City of Campbell staff: Charlotte Andeen, Code Enforcement Officer; Bill Helms, Environmental Compliance; Stephen Rose, Planner (for the subject property); Kathleen Overman, Permit Technician, Building Division; and Roger Storz, Public Works Land Development. No information was obtained from the email requests as of the date of this final Phase I ESA report. On April 6, 2016, Benjamin Berman of IRC performed a walk-in file review at the COC offices. Building permit records on microfiche for the subject property address were searched. In addition, inquires were submitted with the Planning Department and Public Works. No city records were found for the subject property. Santa Clara County Assessor's Office (SCCAO) An assessor’s map for the subject property (APN 414-37-008) was obtained online on March 22, 2016, from the Santa Clara County Assessor’s Office. 6.6 Data Gaps and Data Failure Significant data gaps / data failure were not identified. Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 17 7.0 SIGNATURES OF ENVIRONMENTAL PROFESSIONALS The conclusions of this report are based solely on the Scope of Services outlined and the referenced sources of information. Any additional information that becomes available concerning this report should be submitted to IRC Environmental Consulting, LLC so that our conclusions may be reviewed and modified, if necessary. No soil, groundwater, vapor, or building material samples were collected or analyzed as part of this assessment. This report was prepared in March-April 2016 for the sole use of The Ridgecrest Group and / or their agents. We further understand that The Ridgecrest Group intends to submit a copy of this report to the City of Campbell. Prepared by: Benjamin Berman Project Manager Environmental Professional IRC Environmental Consulting, LLC As per ASTM E 1527-13 Section 12.13, we declare that, to the best of our professional knowledge and belief, we meet the definition of Environmental Professional as defined in 312.10 of 40 CFR 312. We have the specific qualifications based on education, training, and experience to assess a property of the nature, history, and setting of the property. We have developed and performed the all appropriate inquiries in conformance with the standards and practices set forth in 40 CFR Part 312. Reviewed by: David F. Hoexter Environmental Professional California Professional Geologist / Certified Engineering Geologist Hoexter Consulting Inc Project Number 3325 April 20, 2016 _________________________________________________________________________________________________________ IRC Page 18 8.0 REFERENCES GeoSearch. March 28, 2016. Radius Report and various other Phase I ESA reference documents (GeoVantage Package) presented in the appendices of the final Phase I ESA report for the subject property. Regional Water Quality Control Board, San Francisco Bay Region (RWQCB). February 2016. Environmental Screening Levels (ESLs), Tier 1 and Summary Tables, from the internet. Santa Clara County Department of Environmental Health (SCCDEH). December 15, 2014. Fuel Leak Site Case Closure at Jiffy Lube, 1387 Camden Ave., Campbell, CA, Case No, 12-022, SCVWDID No. 08S1W02E02f. (case closure letter) Santa Clara County Department of Environmental Health (SCCDEH). July 10, 2014. Case Closure Summary Report, Site Facility Name: Jiffy Lube No. 297, Site Facility Address: 1387 Camden Avenue. Conestoga-Rovers & Associates (CR&A). October 30, 2013. Groundwater Monitoring Report - Third Quarter 2013, Jiffy Lube No. 297, 1387 Camden Avenue, Campbell, California. Horizon Environmental Inc. (Horizon). June 26, 2013. Groundwater Monitoring I Remediation Status Report and Low Threat Closure Plume Maps, Second Quarter 2013, Tesoro Site No. 67057, 1370 Camden Avenue, Campbell, California, SCVWD ID No. 08SlW02E01f, SCCDEH Case No. 02-015. Conestoga-Rovers & Associates (CR&A). January 11, 2013. Subsurface Investigation Report, Jiffy Lube No. 297, 1387 Camden Avenue, Campbell, California. The American Society for Testing and Materials (ASTM). November 1, 2005. Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. Designation: E 1527-13. California Department of Health Services, California Public Water Supply Branch. 1990. Status Report, AB1803 Small System Program Summary of Results. Gianessi, L.P., and M. Phillips. 1994. Pesticide Use in U.S. Apple Orchards: A Short History. National Center for Food and Agricultural Policy Discussion Paper PS-94-2. State of California, Division of Oil and Gas. 1989. Oil, Gas, and Geothermal Fields in California Map W3-10. United States Geological Survey. 1961, photorevised 1980. San Jose West Quadrangle, California, 7.5-Minute Series, Topographic Map. FIGURES TABLES Table 1, Summary of Aerial Photograph Reviews Page 1 of 1 Table 1, Summary of Aerial Photograph Reviews 1323 Parsons Avenue, Campbell, CA Year Site Use Site Observations 1939 Agricultural The subject property and immediately adjacent properties appear mostly as agricultural fields (orchards). 1948 Agricultural Generally similar to the previous photograph. The subject property and immediately adjacent properties appear as agricultural (orchards). Structures, mostly single-family residences, appear on some immediately adjoining / surrounding properties. 1956 Agricultural Generally similar to the previous photograph. The subject property and immediately adjacent properties appear as agricultural (orchards). Structures, mostly single-family residences, appear in the surrounding area. There appears to be a structure on an adjoining or nearby site to the immediate east of the subject property (current Jiffy Lube, 1387 Camden). 1960 Residential There appears to be a structure (inferred to be the current single family residence) on the subject property proximate to Parsons Avenue, while the majority of the subject property remains undeveloped as currently. Three single family residences and one single family residence appear on adjoining properties to the south and east of the subject property, respectively. The same structure appears on the adjoining property to the north and east proximate to Parsons and Camden Avenue (current Jiffy Lube, 1387 Camden) that appeared on the previous photograph (either a single-family residence or a commercial building). The current post acute care facility (1331 Camden) appears immediately adjoining the subject property to the northwest. Additional development has occurred, mostly single-family residences, in the surrounding area with scattered undeveloped properties containing remnants of orchards. 1968 Residential Generally similar to the previous photograph, however most if not all immediately adjoining properties are now developed, mostly with single family residences. The previous structure on the adjoining property to the north and east (current Jiffy Lube, 1387 Camden) has been replaced with a new "L" shaped structure, likely commercial (possible gasoline service station?). 1974 Unknown Photograph is of insufficient quality, resolution, and / or scale to allow adequate identification of development and activities. 1982 Unknown Photograph is of insufficient quality, resolution, and / or scale to allow adequate identification of development and activities. 1987 Unknown Photograph is of insufficient quality, resolution, and / or scale to allow adequate identification of development and activities. 1993 Residential Generally similar to the 1968 photograph with the following exceptions. All adjoining and surrounding properties are developed; mostly commercial along Camden Avenue and mostly single family residential south and west of the subject property. The previous "L" shaped structure on the adjoining property to the north and east has been replaced again with a rectangular structure (the current Jiffy Lube building on 1387 Camden). 2003 Unknown Photograph is of insufficient quality, resolution, and / or scale to allow adequate identification of development and activities. 2014 Residential Generally similar to the 1993 photograph. Table 2, Summary of City Directories Review Page 1 of 1 Table 2, Summary of City Directories Review 1323 Parsons Avenue, Campbell, CA Year City Directory Listing Subject Property: 1323 Parsons Avenue 1970, 1975, 1980, 1985, 1990-1991 Slough Geo E 1995-1996 No Current Listing 2002, 2007 Slough George 2011, 2015 Address Not Listed Nearby Property (~140-200 ft North to Northwest of Subject Property): 1311 Camden Avenue 1970 Lucky Car Wash 1975, 1980 Terrible Herbst Oil 1990-1991, 1995-1996 4Day Tire Stores 2016 Firestone Tire & Svc Ctr Adjoining Property (East of Subject Property): 1387 Camden Avenue 1970 Pappys Gulf 1970, 1975 Gulf Oil Serv Stns 1980 Gas N Save Campbell 1985 Carsavers 1990-1991, 1995-1996, 2002 Jiffy Lube GeoSearch Note: "No coverage available for Campbell prior to 1970" PHOTOGRAPHS Photographic Notes, 1323 Parsons Ave, Campbell, CA Page 1 of 1 Photographic Notes: 1323 Parsons Ave, Campbell, CA. Site Inspection on 04-07-2016. Proj No. 3325 See Figure 4. (approximate locations and directions of photographs are also shown on Figure 4) Photograph No. 1 – Front of house on subject property, pole mounted transformer on left. Photograph No. 2 – Front of house on subject property on left, Jiffy Lube adjoining site (1387 Camden Ave) on right. Photograph No. 3 – Jiffy Lube site (1387 Camden Ave) on right, house on subject property on left behind fence. Photograph No. 4 – Back of house on subject property, Jiffy Lube site (1387 Camden Ave) on left. Photograph No. 5 – Vegetable garden on subject property on left, Jiffy Lube building on left. Photograph No. 6 – Vegetable garden on subject property in foreground, wood bicycle ramp on subject property with motor cycle storage beneath at center left, Jiffy Lube building at center right. Photograph No. 7 – Vegetable garden on subject property in foreground, wood bicycle ramp on subject property with motor cycle storage beneath and Jiffy Lube building on right. Photograph No. 8 – Vegetable garden on subject property in foreground. Photograph No. 9 – Vegetable garden on subject property in foreground. Photograph No. 10 – Wood bicycle ramps on subject property on left (Jiffy Lube site on left). Photograph No. 11 – Large back lot of subject property looking south, house and bicycle ramp with motor cycle storage on left. Photograph No. 12 – Wood bicycle ramps on subject property on left (Jiffy Lube building on left). Photograph No. 13 – Large back lot of subject property looking south along property boundary. Photograph No. 14 – Looking at Jiffy Lube building from subject property, one of several wood bicycle ramps on subject property on left. Photograph No. 15 – Looking at Jiffy Lube building on left from subject property, vegetable garden in foreground. Photograph No. 16 – Inside larger of two storage sheds, gasoline containers were empty, one 1-gallon container held gas-oil mix for the lawnmower. Photograph No. 17 – Inside smaller of two storage sheds, plant fertilizers and gardening tools. Photograph No. 18 – Motorcycles stored beneath the largest of several wood bicycle ramps. Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 1 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 1 Photograph No. 2 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 2 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 3 Photograph No. 4 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 3 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 5 Photograph No. 6 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 4 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 7 Photograph No. 8 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 5 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 9 Photograph No. 10 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 6 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 11 Photograph No. 12 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 7 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 13 Photograph No. 14 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 8 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 15 Photograph No. 16 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 9 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 17 Photograph No. 18 APPENDICIES NOTE: ALL APPENDICIES ARE ON CD FIGURES TABLES Table 1, Summary of Aerial Photograph Reviews Page 1 of 1 Table 1, Summary of Aerial Photograph Reviews 1323 Parsons Avenue, Campbell, CA Year Site Use Site Observations 1939 Agricultural The subject property and immediately adjacent properties appear mostly as agricultural fields (orchards). 1948 Agricultural Generally similar to the previous photograph. The subject property and immediately adjacent properties appear as agricultural (orchards). Structures, mostly single-family residences, appear on some immediately adjoining / surrounding properties. 1956 Agricultural Generally similar to the previous photograph. The subject property and immediately adjacent properties appear as agricultural (orchards). Structures, mostly single-family residences, appear in the surrounding area. There appears to be a structure on an adjoining or nearby site to the immediate east of the subject property (current Jiffy Lube, 1387 Camden). 1960 Residential There appears to be a structure (inferred to be the current single family residence) on the subject property proximate to Parsons Avenue, while the majority of the subject property remains undeveloped as currently. Three single family residences and one single family residence appear on adjoining properties to the south and east of the subject property, respectively. The same structure appears on the adjoining property to the north and east proximate to Parsons and Camden Avenue (current Jiffy Lube, 1387 Camden) that appeared on the previous photograph (either a single-family residence or a commercial building). The current post acute care facility (1331 Camden) appears immediately adjoining the subject property to the northwest. Additional development has occurred, mostly single-family residences, in the surrounding area with scattered undeveloped properties containing remnants of orchards. 1968 Residential Generally similar to the previous photograph, however most if not all immediately adjoining properties are now developed, mostly with single family residences. The previous structure on the adjoining property to the north and east (current Jiffy Lube, 1387 Camden) has been replaced with a new "L" shaped structure, likely commercial (possible gasoline service station?). 1974 Unknown Photograph is of insufficient quality, resolution, and / or scale to allow adequate identification of development and activities. 1982 Unknown Photograph is of insufficient quality, resolution, and / or scale to allow adequate identification of development and activities. 1987 Unknown Photograph is of insufficient quality, resolution, and / or scale to allow adequate identification of development and activities. 1993 Residential Generally similar to the 1968 photograph with the following exceptions. All adjoining and surrounding properties are developed; mostly commercial along Camden Avenue and mostly single family residential south and west of the subject property. The previous "L" shaped structure on the adjoining property to the north and east has been replaced again with a rectangular structure (the current Jiffy Lube building on 1387 Camden). 2003 Unknown Photograph is of insufficient quality, resolution, and / or scale to allow adequate identification of development and activities. 2014 Residential Generally similar to the 1993 photograph. Table 2, Summary of City Directories Review Page 1 of 1 Table 2, Summary of City Directories Review 1323 Parsons Avenue, Campbell, CA Year City Directory Listing Subject Property: 1323 Parsons Avenue 1970, 1975, 1980, 1985, 1990-1991 Slough Geo E 1995-1996 No Current Listing 2002, 2007 Slough George 2011, 2015 Address Not Listed Nearby Property (~140-200 ft North to Northwest of Subject Property): 1311 Camden Avenue 1970 Lucky Car Wash 1975, 1980 Terrible Herbst Oil 1990-1991, 1995-1996 4Day Tire Stores 2016 Firestone Tire & Svc Ctr Adjoining Property (East of Subject Property): 1387 Camden Avenue 1970 Pappys Gulf 1970, 1975 Gulf Oil Serv Stns 1980 Gas N Save Campbell 1985 Carsavers 1990-1991, 1995-1996, 2002 Jiffy Lube GeoSearch Note: "No coverage available for Campbell prior to 1970" PHOTOGRAPHS Photographic Notes, 1323 Parsons Ave, Campbell, CA Page 1 of 1 Photographic Notes: 1323 Parsons Ave, Campbell, CA. Site Inspection on 04-07-2016. Proj No. 3325 See Figure 4. (approximate locations and directions of photographs are also shown on Figure 4) Photograph No. 1 – Front of house on subject property, pole mounted transformer on left. Photograph No. 2 – Front of house on subject property on left, Jiffy Lube adjoining site (1387 Camden Ave) on right. Photograph No. 3 – Jiffy Lube site (1387 Camden Ave) on right, house on subject property on left behind fence. Photograph No. 4 – Back of house on subject property, Jiffy Lube site (1387 Camden Ave) on left. Photograph No. 5 – Vegetable garden on subject property on left, Jiffy Lube building on left. Photograph No. 6 – Vegetable garden on subject property in foreground, wood bicycle ramp on subject property with motor cycle storage beneath at center left, Jiffy Lube building at center right. Photograph No. 7 – Vegetable garden on subject property in foreground, wood bicycle ramp on subject property with motor cycle storage beneath and Jiffy Lube building on right. Photograph No. 8 – Vegetable garden on subject property in foreground. Photograph No. 9 – Vegetable garden on subject property in foreground. Photograph No. 10 – Wood bicycle ramps on subject property on left (Jiffy Lube site on left). Photograph No. 11 – Large back lot of subject property looking south, house and bicycle ramp with motor cycle storage on left. Photograph No. 12 – Wood bicycle ramps on subject property on left (Jiffy Lube building on left). Photograph No. 13 – Large back lot of subject property looking south along property boundary. Photograph No. 14 – Looking at Jiffy Lube building from subject property, one of several wood bicycle ramps on subject property on left. Photograph No. 15 – Looking at Jiffy Lube building on left from subject property, vegetable garden in foreground. Photograph No. 16 – Inside larger of two storage sheds, gasoline containers were empty, one 1-gallon container held gas-oil mix for the lawnmower. Photograph No. 17 – Inside smaller of two storage sheds, plant fertilizers and gardening tools. Photograph No. 18 – Motorcycles stored beneath the largest of several wood bicycle ramps. Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 1 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 1 Photograph No. 2 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 2 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 3 Photograph No. 4 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 3 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 5 Photograph No. 6 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 4 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 7 Photograph No. 8 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 5 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 9 Photograph No. 10 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 6 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 11 Photograph No. 12 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 7 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 13 Photograph No. 14 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 8 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 15 Photograph No. 16 Project Number 3325 April 2016 Site Location: 1323 Parsons Avenue Photographs, Page 9 of 9 Campbell, California Date of Site Visit: 04-07-2016 Photograph No. 17 Photograph No. 18 APPENDIX A STATEMENT OF QUALIFICATIONS IRC ENVIRONMENTAL CONSULTING, LLC 430 South Fourth Street, San Jose, CA 95112 IRC Environmental Consulting, LLC Qualifications, Benjamin Berman Current Title: Owner / Project Manager REGISTRATIONS / CERTIFICATIONS / TRAINING: •Registered Environmental Property Assessor (REPA): REPA # 628019, National Registry of Environmental Professionals (NREP); April 2, 2013 to present •Registered Environmental Assessor (REA): California # 08222, California Department of Toxic Substances Control (DTSC), September 27, 2006 to July 1, 2012* •EDR Seminar, Vapor Intrusion Risk & Due Diligence Challenges, 12-6-06, Berkeley, CA •EPA / DTSC Educational Workshop, AAI and New Phase I ESA Requirements, 1-25-07, Sacramento, CA •ASTM International Technical & Professional Training, Assessment of Vapor Intrusion IntoStructures on Property Involved in Real Estate Transactions, 6-11-08, San Francisco, CA •EDR Seminar, Due Diligence, Challenges, Updates, 10-8-08, San Francisco, CA •EDR Environmental Due Diligence 101, Principles & Practice, 6 week online trainingcourse, September-October 2009 •NCC-AHMP, 3-day Essentials of Hazardous Materials Management, Overview Course, November 8 – 10, 2011, Oakland, CA •County of Santa Clara Department of Environmental Health, Hazardous Materials Compliance Division, Hazardous Waste Management Training–Small Quantity Generators, November 20, 2014, San Jose, CA EDUCATION: •San Jose State University: B.A. Environmental Studies, 2000 PROFESSIONAL HISTORY: •IRC Environmental Consulting, LLC, San Jose, CA, Owner / Project Manager, February 2015-Present •Consulting Engineers Corporation, Santa Clara, CA, Senior Project Manager, February2012-February 2015 •E2C, Inc, Santa Clara, CA, Project Manager, 2002-January 2012 •Santa Clara Valley Water District, San Jose, CA, Leaking Underground Storage Tank Oversight Program, Case Manager, 2001-2002 •CET Environmental Services, Inc., Richmond, CA, Staff Env. Specialist, 1993-1997 •Aqua Terra Technologies, Inc., Walnut Creek, CA, Staff Scientist, 1988-1993 *The State of California terminated the REA Program on July 1, 2012. IRC Environmental Consulting, LLC 430 South Fourth Street, San Jose, CA 95112-5730 Cell: (408) 313-9376 www.irc-enviro.com ircenvironmental@gmail.com IRC Environmental Consulting, LLC Services IRC ENVIRONMENTAL CONSULTING, LLC 430 South 4th Street, San Jose, CA 95112-5730 (408) 313-9376 www.irc-enviro.com ircenvironmental@gmail.com Complete Environmental Project Management for: •Site Closure / No Further Action •Soil and Groundwater Contamination Sites •Gas stations, automotive repair, dry cleaners, industrial, manufacturing, commercial, retail, office, schools / institutional, multi-unit residential •Leaking Underground Storage Tank (LUST) sites •Petroleum Hydrocarbons / Fuels and Solvent sites •Hazardous Materials (Hazmat) / Hazardous Wastes •Facility Closures •Site Remediation / Cleanup Sampling / Phase II Environmental Site Assessments: soil, groundwater, soil-gas (vapor) Monitoring: Groundwater and Soil-Gas (Vapor) Phase I Environmental Site Assessments Permitting Regulatory Compliance Hazmat Business Plans Above-Ground Storage Tank Spill Prevention Plans Reporting / document writing and compilation IRC ENVIRONMENTAL CONSULTING, LLC 430 South Fourth Street, San Jose, CA 95112 (408) 313-9376, www.irc-enviro.com ircenvironmental@gmail.com Page 1 of 3 IRC Environmental Consulting, LLC Representative Projects •Gasoline Station, Leaking Underground Storage Tank (LUST) site, groundwater monitoring, remediation (dual-phase extraction, soil-vapor and groundwater), investigation, San Jose, CA, July 2014 - on-going, Job # 3232. •Soil and Grab Groundwater Sampling Assessment, Gasoline, Diesel, Oil Range Petroleum Hydrocarbons, Former Fuel USTs, Former Railroad Right of Way, Manufacturing Facility, Santa Clara,CA, June-July 2014, Job # 3229. •Soil-Gas & Soil Sampling Assessment and Report, Automotive Repair Facility, Los Altos, CA, April- September 2014, Job # 3224, 3226. •Baseline shallow soil sampling in secondary containment and report, Metal Plating Facility, Santa Clara, CA, February 2014, Job # 3207. •Facility Closure, Industrial Spray Painting Facility, Santa Clara, CA, November 2013-April 2014, Job # 3204. •Facility Closure, Metal Plating Shop, Sunnyvale, CA, November 2013-March 2014, Job # 3198. •Soil boring, soil and groundwater sampling, former gasoline UST, October-November 2013, Job #3195. •Leaking Underground Storage Tank (LUST) site, gasoline service station, project management, Redwood City, CA, October 2013-Present, CEC Job # 3193. •Near Surface and Stockpile Soil Sampling, Lexington Elementary School, Los Gatos, CA, February- April 2013, Job # 3164. •Assistance to obtain No Further Action / Case Closure, All Foreign Auto / AC Label / Berryman Products (automotive), California Regional Water Quality Control Board – San Francisco Bay Region, January 2013 – November 2013, San Jose, CA, Job # 3163. •Underground Facility Closure, Voluntary Cleanup under Santa Clara County Environmental Health, Former Piercey Toyota (automotive), San Jose, CA, June 2012 – May 2014, Job # 3125. •Near Surface and Stockpile Soil Sampling, Los Altos High School, Los Altos, CA, May & August 2012, Job # 3116. •Phase 1 Environmental Site Assessment, Industrial Condominiums, Sunnyvale, CA, March-April 2012, Job # 3108. •Testing, Removal, Cleanup, Abandoned Drums on Commercial Property, San Jose, CA, November2011, Job # 3085. •Hydraulic Fluid Assessment and Site Closure, Elevator, Residential Condominiums, San Jose, CA,August 2011 to January 2012, Job # 3077. •Phase 1 Environmental Site Assessment, Former Industrial Facility, Santa Clara, CA, August 2011, Job # 3074. •Phase 1 Environmental Site Assessment, Food Production Facility, Hayward, CA, May-June 2011, Job # 3060. •Removal and Site Closure (underground hydraulic lift), San Benito High School, Hollister, CA, May 2011 to May 2012, Job # 3054. •Phase 1 Environmental Site Assessment, Machine Shop / Production, Palo Alto, CA, February 2012, Job # 3049. •Voluntary Cleanup Agreement under State of California Department of Toxic Substances Control,Town & Country Village Shopping Center (former dry cleaner), Palo Alto, CA, December 2010 – Present (on-going), Job # 3037. •Underground Facility Closure (UST system, jet fuel), Aviation Training Center, Closure Work Plan, Oversight, Soil Sampling, Closure Report, San Jose, CA, August-October 2010, Job # 3013. IRC ENVIRONMENTAL CONSULTING, LLC 430 South Fourth Street, San Jose, CA 95112 (408) 313-9376, www.irc-enviro.com ircenvironmental@gmail.com IRC ENVIRONMENTAL CONSULTING, LLC 430 South Fourth Street, San Jose, CA 95112 (408) 313-9376, www.irc-enviro.com ircenvironmental@gmail.com Page 2 of 3 •Phase II Environmental Site Assessment, Near Surface Soil Sampling for Pesticides and Metals (church property, proposed re-development), San Jose, CA, July 2010, Job # 3003. •Phase II Environmental Site Assessment, Grab Groundwater Sampling for VOCs, (high tech facility,new tenant), San Jose, CA, July 2010, Job # 2999-B. •Remediation of diesel impacted soils, work plan, oversight, reporting, (for diesel ASTs) (computer datacenter / internet exchange facility), San Jose, CA, June-December 2010, Job # 3002. •Phase I and Phase II (soil-vapor sampling) Environmental Site Assessments, retail property, Los Altos, CA, May-June 2010, Job # 2997, 3000. •Acid Waste Neutralization Tank System Upgrade & Title 22 Tank Certifications (semiconductor facility), Santa Clara, CA, December 2009 – January 2010, Job # 2967. •Facility Closure Plans, Oversight of Closure Activities, & Final Closure Reports(approved by local fire department for closure of an industrial facility that produced optical and laser glass), Fremont, CA, November 2009 to July 2010, Job # 2945. •Phase II Environmental Site Assessment and soil removal (soil sampling and excavation of soils impacted by hydraulic fluid, release from underground pipe associated with elevator in a residentialcondominium complex), San Jose, CA, June-July 2009, Job # 2930. •Spill Prevention, Control, and Counter Measure (SPCC) Plan, (for diesel ASTs) (computer data center / internet exchange facility), Sunnyvale, CA, May-June, 2009, Job # 2921. •Hazardous Materials Business Plan (HMBP), (primarily diesel and lead-acid battery banks) (computer data center / internet exchange facility), Sunnyvale, CA, May-June, 2009, Job # 2922. •Semi-Annual Wastewater Discharge Compliance Sampling and Reporting, Industrial Spray Painting – Finishing Facility, Santa Clara, CA, May 2009-2013, Job # 2924. •Phase I Environmental Site Assessment (Commercial Condominium complex), San Jose, CA, April 2009, Job # 2913. •Certified Radon Survey (per U.S. EPA requirements), Fremont, CA, March 2009, Job # 2905. •Phase I Environmental Site Assessment (former gas station), San Jose, CA, February 2009 Job # 2900. •Investigation, Odor Intrusion, Industrial, San Jose, CA, February 2009, Job # 2897. •Phase II Environmental Site Assessment (former / current automotive, USTs; soil, groundwater, andsoil-vapor sampling), Santa Clara, CA, January-February 2009, Job # 2894. •Phase I Environmental Site Assessment (former agricultural), Morgan Hill, CA, January-February 2009Job # 2889. •Phase I Environmental Site Assessment (former / current automotive, USTs), Santa Clara, CA, December 2008-January 2009, Job # 2885. •Phase I Environmental Site Assessment (industrial), Scotts Valley, CA, December 2008 Job # 2881. •Phase I Environmental Site Assessment (automotive, gas station), San Jose, CA, November 2008 Job # 2876. •Document Review / Investigation, Former Film Processing and Moisture / Mold Inspection, Santa Clara, CA, October 2008, Job # 2874. •Phase I Environmental Site Assessment (former commercial nursery / landscaping outlet, former UST),Santa Clara, CA, October 2008, Job # 2869. •Phase I Environmental Site Assessment (semi-conductor / electronics assembly, adjacent to U.S. EPAFederal Superfund site), Santa Clara, CA, October 2008, Job # 2866. •Asbestos and Lead Paint abatement, Asbestos Air Clearance and Confirmation Lead Sampling(Shopping center), Modesto, CA, September-October 2008, Job # 2828. •Phase I Environmental Site Assessment (bowling alley, motel, offices, retail, commercial), Palo Alto, CA, August-September 2008, Job # 2861. IRC ENVIRONMENTAL CONSULTING, LLC 430 South Fourth Street, San Jose, CA 95112 (408) 313-9376, www.irc-enviro.com ircenvironmental@gmail.com IRC ENVIRONMENTAL CONSULTING, LLC 430 South Fourth Street, San Jose, CA 95112 (408) 313-9376, www.irc-enviro.com ircenvironmental@gmail.com Page 3 of 3 •Consulting Services, Document Review, Independent 3rd Party Review of Groundwater and Indoor Air Sampling Investigation performed by others (recommendations, proposed scope of work), tenant leasecontract for occupation of new space by high tech computer / electronics manufacturing – assembly company), Sunnyvale, CA, August 2008, Job # 2859. •Phase II Environmental Site Assessment, Near Surface Soil Sampling for Pesticides and Metals, and Phase I Environmental Site Assessment, East Palo Alto, CA, July-August 2008, Job # 2853SC01. •Phase II Environmental Site Assessment, Deep Groundwater Sampling, Soil Sampling, Soil-VaporSampling (apartment building adjacent to retail dry cleaner), Sunnyvale, CA, June-July 2008 Job # 2825SC01. •Phase II Environmental Site Assessment, Sampling in Basement Below Commercial Building, andPhase I Environmental Site Assessment, Palo Alto, CA, July – September 2008, Job # 2846SC01. •Phase II Environmental Site Assessment, Near Surface Soil Sampling for Pesticides and Metals(agricultural property, proposed residential development), Morgan Hill, CA, June-July 2008 Job # 2815SC01. •Phase I Environmental Site Assessment and Phase II Environmental Site Assessment, FormerRailroad Right-Of-Way, soil sampling for VOCs, Metals, SVOCs, PCBs, Pesticides, TEPH (diesel, oil), depth definition soil sampling for arsenic, groundwater sampling to screen for dissolved arsenic, San Jose, CA, August - December 2008, Job # 2842SC01. •Phase I ESA and Phase II, Surface / Near Surface Soil Sampling for Pesticides, 42 Acres of Undeveloped Property (for Residential Subdivision), Morgan Hill, CA, March-July 2008, Job #2815SC01. •Soil-Gas Sampling below Building, Removal of Lead Paint and Asbestos inside Building, Former Supermarket with adjacent dry cleaner (shopping center), Modesto, CA, April-October 2008, Job #2828SC01. •Phase II, Soil and Groundwater Sampling, Warehouse, Commercial-Industrial Property, Sunnyvale,CA, August-December 2007, Job # 2764SC01. •Phase II, Soil-Gas Sampling Below Building and Soil Sampling from Excavations, Warehouse, Commercial-Industrial Property, Sunnyvale, CA, August 2007, Job # 2759SC01. •Phase II, Soil Sampling Inside Building, Dry Cleaner in Shopping Center, San Jose, CA, April-May 2007, Job # 2721SC01. •Phase II, Soil-Gas Sampling Below Building, Indoor Air Sampling, Former Dry Cleaner, Palo Alto, CA, May-June 2007, Job # 2716SC01. APPENDIX B HISTORICAL TOPOGRAPHIC MAPS Target Property: Prepared For: Historical Topographic Maps 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Phase I Environmental Site Assessment IRC Environmental Consulting LLC Job #: 140213 Order #: 64660 Date: 03/24/2016 http://www.geo-search.net/QuickMap/index.htm?DataID=Standard0000140213 Click on link above to access the map and satellite view of current property Project #: 3325 phone: 888-396-0042 · fax: 512-472-9967 · www.geo-search.com TARGET PROPERTY SUMMARY 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Phase I Environmental Site Assessment *Target property is located in Radon Zone 2. Zone 2 areas have a predicted average indoor radon screening level between 2 and 4 pCi/L (picocuries per liter). County/Parish Covered: Zipcode(s) Covered: State(s) Covered: Santa Clara (CA) Campbell CA: 95008 San Jose CA: 95124 CA Target Property Geometry:Point Target Property Longitude(s)/Latitude(s): (-121.944918, 37.268474) USGS Quadrangle:San Jose West, CA Disclaimer - The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer’s interpretation of this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers and independent contractors cannot be held liable for actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 TOPOGRAPHIC MAP  JOB #: 140213 - 3/24/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT QUAD: SAN JOSE WEST, CA DATE: 2012 SCALE: 1:24,000 TOPOGRAPHIC MAP  JOB #: 140213 - 3/24/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT QUAD: SAN JOSE WEST, CA DATE: 1961 PHOTOREVISED 1980 SCALE: 1:24,000 TOPOGRAPHIC MAP  JOB #: 140213 - 3/24/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT QUAD: SAN JOSE WEST, CA DATE: 1961 PHOTOREVISED 1973 SCALE: 1:24,000 TOPOGRAPHIC MAP  JOB #: 140213 - 3/24/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT QUAD: SAN JOSE WEST, CA DATE: 1961 PHOTOREVISED 1968 SCALE: 1:24,000 TOPOGRAPHIC MAP  JOB #: 140213 - 3/24/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT QUAD: SAN JOSE WEST, CA DATE: 1961 SCALE: 1:24,000 TOPOGRAPHIC MAP  JOB #: 140213 - 3/24/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT QUAD: SAN JOSE WEST, CA DATE: 1953 SCALE: 1:24,000 TOPOGRAPHIC MAP  JOB #: 140213 - 3/24/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT QUAD: SAN JOSE, CA DATE: 1943 SCALE: 1:62,500 TOPOGRAPHIC MAP  JOB #: 140213 - 3/24/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT QUAD: SAN JOSE, CA DATE: 1899 SCALE: 1:62,500 APPENDIX C CITY DIRECTORIES City Directory Target Property Address Target Property: 1323 Parsons Ave, Campbell, CA 95008 Prepared For: IRC Environmental Consulting LLC Order #: 64660 Date: 3/25/2016 3325 888-396-0042 www.geo-search.com Page 1 of 5 3/25/2016 3:51:13 PM City Directory Target Property Address 1323 Parsons Ave, Campbell, CA 95008 1323 Parsons Ave 2016 ADDRESS NOT LISTED InfoUSA South West 2011 ADDRESS NOT LISTED InfoUSA Pacific 2007 SLOUGH GEORGE Haines Directory West Santa Clara 2002 SLOUGH GEORGE Haines Directory West Santa Clara 1995-96 NO CURRENT LISTING Haines Directory San Jose 1990-91 SLOUGH GEORGE E Haines Directory San Jose 1985 SLOUGH GEORGE E Haines Directory San Jose 1980 SLOUGH GEORGE E Haines Directory San Jose 1975 SLOUGH GEO E Haines Directory San Jose 1970 SLOUGH GEO E Haines Directory San Jose Parsons Ave 2016 STREET BEGINS InfoUSA South West 2011 STREET BEGINS InfoUSA Pacific 2007 STREET BEGINS Haines Directory West Santa Clara 2007 X [ERIN WAY INTS]Haines Directory West Santa Clara 2002 STREET BEGINS Haines Directory West Santa Clara 2002 X [CAMDEN AV INTS]Haines Directory West Santa Clara 1995-96 STREET BEGINS Haines Directory San Jose 1990-91 STREET BEGINS Haines Directory San Jose 1985 STREET BEGINS Haines Directory San Jose 1980 STREET BEGINS Haines Directory San Jose 1975 STREET BEGINS Haines Directory San Jose 1970 STREET BEGINS Haines Directory San Jose 1308 Parsons Ave 2002 BRUCE PATRICIA Haines Directory West Santa Clara 1995-96 NO CURRENT LISTING Haines Directory San Jose 1990-91 NO CURRENT LISTING Haines Directory San Jose 1985 NO CURRENT LISTING Haines Directory San Jose 1980 NO CURRENT LISTING Haines Directory San Jose 1975 JUDO KARATE STUDIO Haines Directory San Jose 1975 KARATE JUDO STUDIO Haines Directory San Jose 1975 TRACYS KARATE STDO Haines Directory San Jose 888-396-0042 www.geo-search.com Page 2 of 5 3/25/2016 3:51:14 PM City Directory Target Property Address 1323 Parsons Ave, Campbell, CA 95008 1970 GINTHER ERNEST E Haines Directory San Jose 1336 Parsons Ave 2016 GIL R InfoUSA South West 2007 NO CURRENT LISTING Haines Directory West Santa Clara 2002 BRUCE PATRICIA Haines Directory West Santa Clara 1995-96 NO CURRENT LISTING Haines Directory San Jose 1990-91 NO CURRENT LISTING Haines Directory San Jose 1985 NO CURRENT LISTING Haines Directory San Jose 1980 NO CURRENT LISTING Haines Directory San Jose 1975 HAWKS GLENN Haines Directory San Jose 1975 HAWKS WALTRAUD Haines Directory San Jose 1970 WADE JAS E Haines Directory San Jose 1341 Parsons Ave 2016 PARISE CHRIS InfoUSA South West 2007 AOYAMA ALAN Haines Directory West Santa Clara 2007 PARISE JOANNE Haines Directory West Santa Clara 2007 X [SHARP AVE INTS]Haines Directory West Santa Clara 2002 AOYAMA ALAN Haines Directory West Santa Clara 2002 X [SHARP AV INTS]Haines Directory West Santa Clara 1995-96 GRAY JOANNE Haines Directory San Jose 1370 Parsons Ave 2016 NEVE KEITH InfoUSA South West 2007 NEVE KEITH Haines Directory West Santa Clara 2002 NEVE KEITH Haines Directory West Santa Clara 1995-96 AKI RICHARD Haines Directory San Jose 1990-91 NO CURRENT LISTING Haines Directory San Jose 1985 NO CURRENT LISTING Haines Directory San Jose 1980 NO CURRENT LISTING Haines Directory San Jose 1975 GIBBINS C W Haines Directory San Jose 1975 GIBBINS HAZEL Haines Directory San Jose 1970 GIBBINS C W Haines Directory San Jose 1970 GIBBINS HAZEL Haines Directory San Jose 888-396-0042 www.geo-search.com Page 3 of 5 3/25/2016 3:51:14 PM City Directory Target Property Address 1323 Parsons Ave, Campbell, CA 95008 1386 Parsons Ave 2016 TOVAR GABRIEL InfoUSA South West 2011 TOVAR GABRIEL InfoUSA Pacific 2007 TOVAR GABRIEL Haines Directory West Santa Clara 2007 X [PARSONS CT INTS]Haines Directory West Santa Clara 2002 TOVAR GABRIEL Haines Directory West Santa Clara 1995-96 CIFELLI LOUIS Haines Directory San Jose 1990-91 NO CURRENT LISTING Haines Directory San Jose 1985 WHITSON HARVEY S Haines Directory San Jose 1980 WHITSON HARVEY S Haines Directory San Jose 1975 WHITSON HARVEY S Haines Directory San Jose 1970 JONES IONA Haines Directory San Jose 1970 JONES RONNIE L Haines Directory San Jose 1391 Parsons Ave 2002 STRINGHAM RYAN Haines Directory West Santa Clara 2002 X [PARSONS CT INTS]Haines Directory West Santa Clara 1995-96 THOMPSON LOEL Haines Directory San Jose 1990-91 NO CURRENT LISTING Haines Directory San Jose 1985 NO CURRENT LISTING Haines Directory San Jose 1980 NO CURRENT LISTING Haines Directory San Jose 1975 DIXON DALE Haines Directory San Jose 1970 DIXON DALE Haines Directory San Jose 1404 Parsons Ave 2016 MONTOYA DENISE InfoUSA South West 2007 MONTOYA DENISE Haines Directory West Santa Clara 2002 MONTOYA DENISE Haines Directory West Santa Clara 1995-96 HANZ CHRISTINE Haines Directory San Jose 1985 NO CURRENT LISTING Haines Directory San Jose 1980 NO CURRENT LISTING Haines Directory San Jose 1975 NO CURRENT LISTING Haines Directory San Jose 1970 ROYETON TOM Haines Directory San Jose 1425 Parsons Ave 1990-91 VIRGILIO I J Haines Directory San Jose 888-396-0042 www.geo-search.com Page 4 of 5 3/25/2016 3:51:14 PM City Directory Target Property Address 1323 Parsons Ave, Campbell, CA 95008 1475 Parsons Ave 2011 YANG L InfoUSA Pacific Comment:No coverage available for Campbell prior to 1970. 888-396-0042 www.geo-search.com Page 5 of 5 3/25/2016 3:51:14 PM City Directory Standard Report Target Property: 1323 Parsons Ave, Campbell, CA 95008 Prepared For: IRC Environmental Consulting LLC Order #: 64660 Date: 3/25/2016 3325 888-396-0042 www.geo-search.com Page 1 of 5 3/25/2016 3:48:56 PM City Directory Standard Report 1323 Parsons Ave, Campbell, CA 95008 InfoUSA South West 2016 Parsons Ave STREET BEGINS 1323 ADDRESS NOT LISTED 1336 GIL R 1341 PARISE CHRIS 1370 NEVE KEITH 1386 TOVAR GABRIEL 1404 MONTOYA DENISE InfoUSA Pacific 2011 Parsons Ave STREET BEGINS 1323 ADDRESS NOT LISTED 1386 TOVAR GABRIEL 1475 YANG L Haines Directory West Santa Clara 2007 Parsons Ave STREET BEGINS X [ERIN WAY INTS] 1323 SLOUGH GEORGE 1336 NO CURRENT LISTING 1341 AOYAMA ALAN 1341 PARISE JOANNE 1341 X [SHARP AVE INTS] 1370 NEVE KEITH 1386 TOVAR GABRIEL 1386 X [PARSONS CT INTS] 1404 MONTOYA DENISE Haines Directory West Santa Clara 2002 Parsons Ave STREET BEGINS X [CAMDEN AV INTS] 888-396-0042 www.geo-search.com Page 2 of 5 3/25/2016 3:48:57 PM City Directory Standard Report 1323 Parsons Ave, Campbell, CA 95008 1308 BRUCE PATRICIA 1323 SLOUGH GEORGE 1336 BRUCE PATRICIA 1341 AOYAMA ALAN 1341 X [SHARP AV INTS] 1370 NEVE KEITH 1386 TOVAR GABRIEL 1391 STRINGHAM RYAN 1391 X [PARSONS CT INTS] 1404 MONTOYA DENISE Haines Directory San Jose 1995-96 Parsons Ave STREET BEGINS 1308 NO CURRENT LISTING 1323 NO CURRENT LISTING 1336 NO CURRENT LISTING 1341 GRAY JOANNE 1370 AKI RICHARD 1386 CIFELLI LOUIS 1391 THOMPSON LOEL 1404 HANZ CHRISTINE Haines Directory San Jose 1990-91 Parsons Ave STREET BEGINS 1308 NO CURRENT LISTING 1323 SLOUGH GEORGE E 1336 NO CURRENT LISTING 1370 NO CURRENT LISTING 1386 NO CURRENT LISTING 1391 NO CURRENT LISTING 1425 VIRGILIO I J Haines Directory 888-396-0042 www.geo-search.com Page 3 of 5 3/25/2016 3:48:57 PM City Directory Standard Report 1323 Parsons Ave, Campbell, CA 95008 San Jose 1985 Parsons Ave STREET BEGINS 1308 NO CURRENT LISTING 1323 SLOUGH GEORGE E 1336 NO CURRENT LISTING 1370 NO CURRENT LISTING 1386 WHITSON HARVEY S 1391 NO CURRENT LISTING 1404 NO CURRENT LISTING Haines Directory San Jose 1980 Parsons Ave STREET BEGINS 1308 NO CURRENT LISTING 1323 SLOUGH GEORGE E 1336 NO CURRENT LISTING 1370 NO CURRENT LISTING 1386 WHITSON HARVEY S 1391 NO CURRENT LISTING 1404 NO CURRENT LISTING Haines Directory San Jose 1975 Parsons Ave STREET BEGINS 1308 JUDO KARATE STUDIO 1308 KARATE JUDO STUDIO 1308 TRACYS KARATE STDO 1323 SLOUGH GEO E 1336 HAWKS GLENN 1336 HAWKS WALTRAUD 1370 GIBBINS C W 1370 GIBBINS HAZEL 1386 WHITSON HARVEY S 1391 DIXON DALE 1404 NO CURRENT LISTING 888-396-0042 www.geo-search.com Page 4 of 5 3/25/2016 3:48:57 PM City Directory Standard Report 1323 Parsons Ave, Campbell, CA 95008 Haines Directory San Jose 1970 Parsons Ave STREET BEGINS 1308 GINTHER ERNEST E 1323 SLOUGH GEO E 1336 WADE JAS E 1370 GIBBINS C W 1370 GIBBINS HAZEL 1386 JONES IONA 1386 JONES RONNIE L 1391 DIXON DALE 1404 ROYETON TOM Comment:No coverage available for Campbell prior to 1970. 888-396-0042 www.geo-search.com Page 5 of 5 3/25/2016 3:48:57 PM City Directory Target Property Address Target Property: Camden Ave, Campbell, CA 95008 Prepared For: IRC Environmental Consulting LLC Order #: 64660 Date: 3/25/2016 3325 888-396-0042 www.geo-search.com Page 1 of 8 3/25/2016 3:47:26 PM City Directory Target Property Address Camden Ave, Campbell, CA 95008 1300 Camden Ave 2016 CARLYLE HOTEL InfoUSA South West 2016 PATEL PREETY InfoUSA South West 2011 CARLYLE HOTEL InfoUSA Pacific 2011 PATEL PREETY InfoUSA Pacific 2007 CARLYLE HOTEL Haines Directory West Santa Clara 2007 EXECUTIVE INN SUITE Haines Directory West Santa Clara 2002 CARLYLE HOTEL Haines Directory West Santa Clara 2002 EXECUTIVE INN SUITE Haines Directory West Santa Clara 2002 MANRAO KENNETH Haines Directory West Santa Clara 1995-96 EXECUTIVE INN SUITE Haines Directory San Jose 1990-91 EXECUTIVE INN SUITE Haines Directory San Jose 1985 JAMES CHOW SERVICES Haines Directory San Jose 1985 JARTRAN TRUCK RENTL Haines Directory San Jose 1980 CHOWS TEXACO STATN Haines Directory San Jose 1980 CHOWS TEXACO STATNS Haines Directory San Jose 1980 RYDER TRUCK RENTAL Haines Directory San Jose 1975 CHOWS TEXACO Haines Directory San Jose 1975 U HAUL CO Haines Directory San Jose 1970 BILLS DOUGLAS SERV Haines Directory San Jose 1970 CAMDEN AUTO ELECTRIC Haines Directory San Jose 1970 U HAUL COMPANY DLRS Haines Directory San Jose 1301 Camden Ave 2016 JACK IN THE BOX InfoUSA South West 2011 JACK IN THE BOX InfoUSA Pacific 2007 JACK-IN-THE-Haines Directory West Santa Clara 2002 JACK IN THE BOX Haines Directory West Santa Clara 1995-96 JACK NI THE BOX Haines Directory San Jose 1990-91 JACK IN THE BOX Haines Directory San Jose 1985 JACK IN THE BOX Haines Directory San Jose 1980 JACK IN THE BOX Haines Directory San Jose 1975 JACK IN THE BOX Haines Directory San Jose 1970 JACK IN THE BOX Haines Directory San Jose 888-396-0042 www.geo-search.com Page 2 of 8 3/25/2016 3:47:26 PM City Directory Target Property Address Camden Ave, Campbell, CA 95008 1311 Camden Ave 2016 FIRESTONE TIRE & SVC CTR InfoUSA South West 2016 FLOOR CENTER InfoUSA South West 2011 FLOOR CENTER InfoUSA Pacific 2007 FLOOR CENTER THE Haines Directory West Santa Clara 2002 A&B FLOOR DESIGNER Haines Directory West Santa Clara 2002 FLOOR CENTER THE Haines Directory West Santa Clara 2002 MOLAIE MARJANEH Haines Directory West Santa Clara 1995-96 4DAY TIRE STORES Haines Directory San Jose 1990-91 4DAY TIRE STORES Haines Directory San Jose 1985 NO CURRENT LISTING Haines Directory San Jose 1980 TERRIBLE HERBST OIL Haines Directory San Jose 1975 TERRIBLE HERBST OIL Haines Directory San Jose 1970 LUCKY CAR WASH Haines Directory San Jose 1330 Camden Ave 2016 LIL DOG BIG DOG InfoUSA South West 2016 WIENERSCHNITZEL InfoUSA South West 2011 WIENERSCHNITZEL InfoUSA Pacific 2007 WIENERSCHNIT Haines Directory West Santa Clara 2002 OLDHAM JOHN Haines Directory West Santa Clara 2002 WIENERSCHNITZEL Haines Directory West Santa Clara 1995-96 WIENERSCHNITZEL Haines Directory San Jose 1990-91 WIENERSCHNITZEL Haines Directory San Jose 1985 WIENERSCHNITZEL Haines Directory San Jose 1980 NO CURRENT LISTING Haines Directory San Jose 1331 Camden Ave 2016 AMRIKHAS AUSHOR InfoUSA South West 2016 PADILLA EVA InfoUSA South West 2016 ROMERO ROSEMARIE InfoUSA South West 2011 BADILLO E InfoUSA Pacific 2011 CAMDEN CONVALESCENT HOSPITAL InfoUSA Pacific 2011 FISHSTROM D InfoUSA Pacific 2011 GREEN EDITH InfoUSA Pacific 888-396-0042 www.geo-search.com Page 3 of 8 3/25/2016 3:47:26 PM City Directory Target Property Address Camden Ave, Campbell, CA 95008 2011 SOUTH PACIFIC REHAB CAMDEN InfoUSA Pacific 2007 CAMDEN CONVLSCNT HSP Haines Directory West Santa Clara 2007 GREEN EDITH Haines Directory West Santa Clara 2007 HUBBARD ZELLA Haines Directory West Santa Clara 2007 TREVEY D Haines Directory West Santa Clara 2002 ANGELI THERESA Haines Directory West Santa Clara 2002 BASSETT LINDA Haines Directory West Santa Clara 2002 BEZUCHA MYRTLE Haines Directory West Santa Clara 2002 CAMDEN CONVLSNT Haines Directory West Santa Clara 2002 MATHIS RAYMOND Haines Directory West Santa Clara 1995-96 CAMDEN CONVLSNT HSP Haines Directory San Jose 1990-91 CAMDEN CONVLSNT HSP Haines Directory San Jose 1985 CAMDEN CNVLSNT HOSP Haines Directory San Jose 1980 CAMDEN CNVLSCNT HSP Haines Directory San Jose 1975 CAMDEN CNVLSCNT HSP Haines Directory San Jose 1975 COFFEY HARRIET A Haines Directory San Jose 1970 CAMDEN CNVLSCNT HSP Haines Directory San Jose 1350 Camden Ave 2016 ROYAL TAJ INDIAN CUISINE InfoUSA South West 2011 INDIA FOOD INC InfoUSA Pacific 2011 ROYAL TAJ INDIA CUISINE InfoUSA Pacific 2007 ROYAL TAJ INDIA CUISINE Haines Directory West Santa Clara 2002 ROYAL TAJ INDIA CUISINE Haines Directory West Santa Clara 2002 SIGNORELLI JEANNE Haines Directory West Santa Clara 1995-96 ROYAL TAJ CUISINE Haines Directory San Jose 1990-91 ROYAL TAJ IND CUISN Haines Directory San Jose 1985 SOMETHING FISHY Haines Directory San Jose 1980 NO CURRENT LISTING Haines Directory San Jose 1975 MISTER DONUT Haines Directory San Jose 1970 MISTER DONUT Haines Directory San Jose 1360 Camden Ave 2011 FOSTER'S FREEZE InfoUSA Pacific 2007 FOSTER'S FREEZE Haines Directory West Santa Clara 888-396-0042 www.geo-search.com Page 4 of 8 3/25/2016 3:47:26 PM City Directory Target Property Address Camden Ave, Campbell, CA 95008 2002 CAMDEN FOSTER FRZE Haines Directory West Santa Clara 2002 FOSTER FREEZE CMPBL Haines Directory West Santa Clara 2002 HERSERY RICHARD Haines Directory West Santa Clara 1995-96 CAMDEN FOSTER FRZE Haines Directory San Jose 1995-96 FOSTER FREEZE CMPBL Haines Directory San Jose 1990-91 CAMDEN FOSTER FRZE Haines Directory San Jose 1990-91 FOSTER FREEZE CMPBL Haines Directory San Jose 1985 CAMDEN FOSTER FRZE Haines Directory San Jose 1985 FOSTER FREEZE CMPBL Haines Directory San Jose 1980 CAMDEN FSTR FREEZE Haines Directory San Jose 1980 FOSTER FREEZE CMPBL Haines Directory San Jose 1975 CAMDEN FSTR FREEZE Haines Directory San Jose 1975 FOSTER FREEZE CMPBL Haines Directory San Jose 1970 BUDS FOSTERS FREEZE Haines Directory San Jose 1370 Camden Ave 2016 SHELL InfoUSA South West 2016 TESORO InfoUSA South West 2011 USA GASOLINE InfoUSA Pacific 2007 USA PETROLEUM CORP Haines Directory West Santa Clara 2002 BEACON SERVICE STATION Haines Directory West Santa Clara 2002 FERRARI AUGUSTINE Haines Directory West Santa Clara 1995-96 BEACON SV STA 420 Haines Directory San Jose 1990-91 BEACON SC STNS 420 Haines Directory San Jose 1985 BEACON SV STNS 420 Haines Directory San Jose 1980 BEACON SV STNS 420 Haines Directory San Jose 1975 BEACON SERV STN 420 Haines Directory San Jose 1970 BEACON SV STNS 420 Haines Directory San Jose 1387 Camden Ave 2016 JIFFY LUBE InfoUSA South West 2011 JIFFY LUBE InfoUSA Pacific 2007 JIFFY LUBE Haines Directory West Santa Clara 2007 X [PARSONS AVE INTS]Haines Directory West Santa Clara 2007 Y [ERIN WAY INTS]Haines Directory West Santa Clara 888-396-0042 www.geo-search.com Page 5 of 8 3/25/2016 3:47:26 PM City Directory Target Property Address Camden Ave, Campbell, CA 95008 2002 JIFFY LUBE Haines Directory West Santa Clara 2002 X [ERIN WAY INTS]Haines Directory West Santa Clara 2002 Y [PARSONS AV INTS]Haines Directory West Santa Clara 1995-96 JIFFY LUBE Haines Directory San Jose 1990-91 JIFFY LUBE Haines Directory San Jose 1985 CARSAVERS Haines Directory San Jose 1980 GAS N SAVE CAMPBELL Haines Directory San Jose 1975 GULF OIL SERV STNS Haines Directory San Jose 1970 GULF OIL SERV STNS Haines Directory San Jose 1970 PAPPYS GULF Haines Directory San Jose 1401 Camden Ave 2002 NO CURRENT LISTING Haines Directory West Santa Clara 1995-96 NO CURRENT LISTING Haines Directory San Jose 1990-91 B&M MOTORS Haines Directory San Jose 1985 DRAPERY MAN INC THE Haines Directory San Jose 1980 DRAPERY MAN INC THE Haines Directory San Jose 1402 Camden Ave 2016 DICKEY'S BARBECUE PIT InfoUSA South West 2016 SUBWAY InfoUSA South West 2011 LAVENDER BEAUTY SPA InfoUSA Pacific 2011 SUBWAY InfoUSA Pacific 2002 NO CURRENT LISTING Haines Directory West Santa Clara 1995-96 CHEVRON SERVICE CTR Haines Directory San Jose 1990-91 CHEVRON STA CAMPBLL Haines Directory San Jose 1990-91 LARAWAY CHEVRON SRV Haines Directory San Jose 1985 CHEVRON STA CAMPBLL Haines Directory San Jose 1985 LARAWAY CHEVRON SRV Haines Directory San Jose 1980 CHEVRON STA CAMPBLL Haines Directory San Jose 1980 LARAWAY CHEVRON SV Haines Directory San Jose 1975 CHEVRON STNDRD STNS Haines Directory San Jose 1975 LARAWAY CHEVRON SV Haines Directory San Jose 1970 INTERSTATE RENT CAR Haines Directory San Jose 1970 LARAWAY CHEVRON SV Haines Directory San Jose 888-396-0042 www.geo-search.com Page 6 of 8 3/25/2016 3:47:26 PM City Directory Target Property Address Camden Ave, Campbell, CA 95008 1403 Camden Ave 2016 HAPPY T NAILS InfoUSA South West 2016 HEAD TO TOE SALON InfoUSA South West 2016 K T NAILS InfoUSA South West 2011 HEAD TO TOE SALON InfoUSA Pacific 2011 K T NAILS InfoUSA Pacific 2007 HEAD TO TOE SALON Haines Directory West Santa Clara 2002 HEAD TO TOE SALON Haines Directory West Santa Clara 1995-96 HEAD TO TOE SALON Haines Directory San Jose 1995-96 NAILS BY JANINE Haines Directory San Jose 1995-96 ROBINS NAILS Haines Directory San Jose 1990-91 SYNTHETIC IMAGES Haines Directory San Jose 1985 MATTERHORN TAILOR Haines Directory San Jose 1980 MATTERHORN TAILOR Haines Directory San Jose 1980 RECARENS RUTH TLRNG Haines Directory San Jose 1404 Camden Ave 2016 LIBERTY TAX SVC InfoUSA South West 2011 LIBERTY TAX SVC InfoUSA Pacific 1405 Camden Ave 2016 H & R BLOCK InfoUSA South West 2011 SERRANO MORALES INC InfoUSA Pacific 2007 2001 CONSTRUCTION GROUP Haines Directory West Santa Clara 2007 2001 DESIGN STUDIO Haines Directory West Santa Clara 2002 2001 CONSTRUCTION GROUP Haines Directory West Santa Clara 2002 2001 DESIGN STUDIO Haines Directory West Santa Clara 1995-96 NO CURRENT LISTING Haines Directory San Jose 1990-91 PREFERRED SALES & LSG Haines Directory San Jose 1985 PREFERRED SALES & LSG Haines Directory San Jose 1412 Camden Ave 2011 SIP CAFE InfoUSA Pacific 1430 Camden Ave 2002 NO CURRENT LISTING Haines Directory West Santa Clara 888-396-0042 www.geo-search.com Page 7 of 8 3/25/2016 3:47:26 PM City Directory Target Property Address Camden Ave, Campbell, CA 95008 1450 Camden Ave 2016 TACO BELL InfoUSA South West 2011 TACO BELL InfoUSA Pacific 2007 NO CURRENT LISTING Haines Directory West Santa Clara 2002 KIM YOO Haines Directory West Santa Clara 1995-96 NO CURRENT LISTING Haines Directory San Jose 1990-91 NO CURRENT LISTING Haines Directory San Jose 1985 STEREO HABITAT Haines Directory San Jose 1980 GEMINI SOUNDS Haines Directory San Jose 1980 STEREO HABITAT Haines Directory San Jose 1975 WOODIES Haines Directory San Jose 1970 COL SANDERS BEEF Haines Directory San Jose 1970 KENTUCKY ROAST BEEF Haines Directory San Jose Comment:No coverage available for Campbell prior to 1970 888-396-0042 www.geo-search.com Page 8 of 8 3/25/2016 3:47:26 PM City Directory Standard Report Target Property: Camden Ave, Campbell, CA 95008 Prepared For: IRC Environmental Consulting LLC Order #: 64660 Date: 3/25/2016 3325 888-396-0042 www.geo-search.com Page 1 of 8 3/25/2016 3:46:24 PM City Directory Standard Report Camden Ave, Campbell, CA 95008 InfoUSA South West 2016 Camden Ave 1300 CARLYLE HOTEL 1300 PATEL PREETY 1301 JACK IN THE BOX 1311 FIRESTONE TIRE & SVC CTR 1311 FLOOR CENTER 1330 LIL DOG BIG DOG 1330 WIENERSCHNITZEL 1331 AMRIKHAS AUSHOR 1331 PADILLA EVA 1331 ROMERO ROSEMARIE 1350 ROYAL TAJ INDIAN CUISINE 1370 SHELL 1370 TESORO 1387 JIFFY LUBE 1402 DICKEY'S BARBECUE PIT 1402 SUBWAY 1403 HAPPY T NAILS 1403 HEAD TO TOE SALON 1403 K T NAILS 1404 LIBERTY TAX SVC 1405 H & R BLOCK 1450 TACO BELL InfoUSA Pacific 2011 Camden Ave 1300 CARLYLE HOTEL 1300 PATEL PREETY 1301 JACK IN THE BOX 1311 FLOOR CENTER 1330 WIENERSCHNITZEL 1331 BADILLO E 1331 CAMDEN CONVALESCENT HOSPITAL 888-396-0042 www.geo-search.com Page 2 of 8 3/25/2016 3:46:24 PM City Directory Standard Report Camden Ave, Campbell, CA 95008 1331 FISHSTROM D 1331 GREEN EDITH 1331 SOUTH PACIFIC REHAB CAMDEN 1350 INDIA FOOD INC 1350 ROYAL TAJ INDIA CUISINE 1360 FOSTER'S FREEZE 1370 USA GASOLINE 1387 JIFFY LUBE 1402 LAVENDER BEAUTY SPA 1402 SUBWAY 1403 HEAD TO TOE SALON 1403 K T NAILS 1404 LIBERTY TAX SVC 1405 SERRANO MORALES INC 1412 SIP CAFE 1450 TACO BELL Haines Directory West Santa Clara 2007 Camden Ave 1300 CARLYLE HOTEL 1300 EXECUTIVE INN SUITE 1301 JACK-IN-THE- 1311 FLOOR CENTER THE 1330 WIENERSCHNIT 1331 CAMDEN CONVLSCNT HSP 1331 GREEN EDITH 1331 HUBBARD ZELLA 1331 TREVEY D 1350 ROYAL TAJ INDIA CUISINE 1360 FOSTER'S FREEZE 1370 USA PETROLEUM CORP 1387 JIFFY LUBE 1387 X [PARSONS AVE INTS] 1387 Y [ERIN WAY INTS] 888-396-0042 www.geo-search.com Page 3 of 8 3/25/2016 3:46:25 PM City Directory Standard Report Camden Ave, Campbell, CA 95008 1403 HEAD TO TOE SALON 1405 2001 CONSTRUCTION GROUP 1405 2001 DESIGN STUDIO 1450 NO CURRENT LISTING Haines Directory West Santa Clara 2002 Camden Ave 1300 CARLYLE HOTEL 1300 EXECUTIVE INN SUITE 1300 MANRAO KENNETH 1301 JACK IN THE BOX 1311 A&B FLOOR DESIGNER 1311 FLOOR CENTER THE 1311 MOLAIE MARJANEH 1330 OLDHAM JOHN 1330 WIENERSCHNITZEL 1331 ANGELI THERESA 1331 BASSETT LINDA 1331 BEZUCHA MYRTLE 1331 CAMDEN CONVLSNT 1331 MATHIS RAYMOND 1350 ROYAL TAJ INDIA CUISINE 1350 SIGNORELLI JEANNE 1360 CAMDEN FOSTER FRZE 1360 FOSTER FREEZE CMPBL 1360 HERSERY RICHARD 1370 BEACON SERVICE STATION 1370 FERRARI AUGUSTINE 1387 JIFFY LUBE 1387 X [ERIN WAY INTS] 1387 Y [PARSONS AV INTS] 1401 NO CURRENT LISTING 1402 NO CURRENT LISTING 1403 HEAD TO TOE SALON 888-396-0042 www.geo-search.com Page 4 of 8 3/25/2016 3:46:25 PM City Directory Standard Report Camden Ave, Campbell, CA 95008 1405 2001 CONSTRUCTION GROUP 1405 2001 DESIGN STUDIO 1430 NO CURRENT LISTING 1450 KIM YOO Haines Directory San Jose 1995-96 Camden Ave 1300 EXECUTIVE INN SUITE 1301 JACK NI THE BOX 1311 4DAY TIRE STORES 1330 WIENERSCHNITZEL 1331 CAMDEN CONVLSNT HSP 1350 ROYAL TAJ CUISINE 1360 CAMDEN FOSTER FRZE 1360 FOSTER FREEZE CMPBL 1370 BEACON SV STA 420 1387 JIFFY LUBE 1401 NO CURRENT LISTING 1402 CHEVRON SERVICE CTR 1403 HEAD TO TOE SALON 1403 NAILS BY JANINE 1403 ROBINS NAILS 1405 NO CURRENT LISTING 1450 NO CURRENT LISTING Haines Directory San Jose 1990-91 Camden Ave 1300 EXECUTIVE INN SUITE 1301 JACK IN THE BOX 1311 4DAY TIRE STORES 1330 WIENERSCHNITZEL 1331 CAMDEN CONVLSNT HSP 1350 ROYAL TAJ IND CUISN 1360 CAMDEN FOSTER FRZE 1360 FOSTER FREEZE CMPBL 888-396-0042 www.geo-search.com Page 5 of 8 3/25/2016 3:46:26 PM City Directory Standard Report Camden Ave, Campbell, CA 95008 1370 BEACON SC STNS 420 1387 JIFFY LUBE 1401 B&M MOTORS 1402 CHEVRON STA CAMPBLL 1402 LARAWAY CHEVRON SRV 1403 SYNTHETIC IMAGES 1405 PREFERRED SALES & LSG 1450 NO CURRENT LISTING Haines Directory San Jose 1985 Camden Ave 1300 JAMES CHOW SERVICES 1300 JARTRAN TRUCK RENTL 1301 JACK IN THE BOX 1311 NO CURRENT LISTING 1330 WIENERSCHNITZEL 1331 CAMDEN CNVLSNT HOSP 1350 SOMETHING FISHY 1360 CAMDEN FOSTER FRZE 1360 FOSTER FREEZE CMPBL 1370 BEACON SV STNS 420 1387 CARSAVERS 1401 DRAPERY MAN INC THE 1402 CHEVRON STA CAMPBLL 1402 LARAWAY CHEVRON SRV 1403 MATTERHORN TAILOR 1405 PREFERRED SALES & LSG 1450 STEREO HABITAT Haines Directory San Jose 1980 Camden Ave 1300 CHOWS TEXACO STATN 1300 CHOWS TEXACO STATNS 1300 RYDER TRUCK RENTAL 1301 JACK IN THE BOX 888-396-0042 www.geo-search.com Page 6 of 8 3/25/2016 3:46:26 PM City Directory Standard Report Camden Ave, Campbell, CA 95008 1311 TERRIBLE HERBST OIL 1330 NO CURRENT LISTING 1331 CAMDEN CNVLSCNT HSP 1350 NO CURRENT LISTING 1360 CAMDEN FSTR FREEZE 1360 FOSTER FREEZE CMPBL 1370 BEACON SV STNS 420 1387 GAS N SAVE CAMPBELL 1401 DRAPERY MAN INC THE 1402 CHEVRON STA CAMPBLL 1402 LARAWAY CHEVRON SV 1403 MATTERHORN TAILOR 1403 RECARENS RUTH TLRNG 1450 GEMINI SOUNDS 1450 STEREO HABITAT Haines Directory San Jose 1975 Camden Ave 1300 CHOWS TEXACO 1300 U HAUL CO 1301 JACK IN THE BOX 1311 TERRIBLE HERBST OIL 1331 CAMDEN CNVLSCNT HSP 1331 COFFEY HARRIET A 1350 MISTER DONUT 1360 CAMDEN FSTR FREEZE 1360 FOSTER FREEZE CMPBL 1370 BEACON SERV STN 420 1387 GULF OIL SERV STNS 1402 CHEVRON STNDRD STNS 1402 LARAWAY CHEVRON SV 1450 WOODIES Haines Directory 888-396-0042 www.geo-search.com Page 7 of 8 3/25/2016 3:46:26 PM City Directory Standard Report Camden Ave, Campbell, CA 95008 San Jose 1970 Camden Ave 1300 BILLS DOUGLAS SERV 1300 CAMDEN AUTO ELECTRIC 1300 U HAUL COMPANY DLRS 1301 JACK IN THE BOX 1311 LUCKY CAR WASH 1331 CAMDEN CNVLSCNT HSP 1350 MISTER DONUT 1360 BUDS FOSTERS FREEZE 1370 BEACON SV STNS 420 1387 GULF OIL SERV STNS 1387 PAPPYS GULF 1402 INTERSTATE RENT CAR 1402 LARAWAY CHEVRON SV 1450 COL SANDERS BEEF 1450 KENTUCKY ROAST BEEF Comment:No coverage available for Campbell prior to 1970 888-396-0042 www.geo-search.com Page 8 of 8 3/25/2016 3:46:27 PM APPENDIX D AERIAL PHOTOGRAPHS Target Property: Prepared For: Historical Aerials Package 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Phase I Environmental Site Assessment IRC Environmental Consulting LLC Job #: 140218 Order #: 64660 Date: 03/25/2016 http://www.geo-search.net/QuickMap/index.htm?DataID=Standard0000140218 Click on link above to access the map and satellite view of current property Project #: 3325 phone: 888-396-0042 · fax: 512-472-9967 · www.geo-search.com TARGET PROPERTY SUMMARY 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Phase I Environmental Site Assessment *Target property is located in Radon Zone 2. Zone 2 areas have a predicted average indoor radon screening level between 2 and 4 pCi/L (picocuries per liter). County/Parish Covered: Zipcode(s) Covered: State(s) Covered: Santa Clara (CA) Campbell CA: 95008 San Jose CA: 95124 CA Target Property Geometry:Point Target Property Longitude(s)/Latitude(s): (-121.944918, 37.268474) USGS Quadrangle:San Jose West, CA Disclaimer - The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer’s interpretation of this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers and independent contractors cannot be held liable for actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: USDA DATE: 2014 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: USDA DATE: 2003 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: USGS DATE: 06/14/1993 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: USGS DATE: 07/02/1987 COUNTY: SANTA CLARA, CA SCALE: 1" = 1320' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: USGS DATE: 07/05/1982 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: USGS DATE: 06/25/1974 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: USGS DATE: 06/14/1968 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: USGS DATE: 08/23/1960 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: ASCS DATE: 06/09/1956 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: USGS DATE: 09/26/1948 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' TOPOGRAPHIC MAP  JOB #: 140218 - 3/25/2016 SITE: PHASE I ENVIRONMENTAL SITE ASSESSMENT SOURCE: ASCS DATE: 07/31/1939 COUNTY: SANTA CLARA, CA SCALE: 1" = 500' APPENDIX E FIRE INSURANCE / SANBORN MAP REPORT Date: 03/22/16 GS Job Number:64660 Company Name:IRC Environmental Consulting LLC Project Number:3325 Site Information:Phase I Environmental Site Assessment 1323 Parsons Ave, Santa Clara, Campbell, California, 95008 The collections of fire insurance maps listed below were reviewed according to the site information supplied by client. Based on the information provided, no coverage is available. Library of Congress University Publications of America Other Libraries (universities, state, local, etc.). Disclaimer – The information in this report was obtained from a variety of public sources. GeoSearch cannot insure or makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customers interpretation of this report. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers and independent contractors cannot be held liable for actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. 888-396-0042 * FAX 512-472-9967 * www.Geo-Search.com APPENDIX F ENVIRONMENTAL LIEN SEARCH Target Property: Prepared For: Environmental Lien 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Phase I Environmental Site Assessment IRC Environmental Consulting LLC Job #: 140212 Order #: 64660 Date: 03/25/2016 http://www.geo-search.net/QuickMap/index.htm?DataID=Standard0000140212 Click on link above to access the map and satellite view of current property Project #: 3325 phone: 888-396-0042 · fax: 512-472-9967 · www.geo-search.com TARGET PROPERTY SUMMARY 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Phase I Environmental Site Assessment *Target property is located in Radon Zone 2. Zone 2 areas have a predicted average indoor radon screening level between 2 and 4 pCi/L (picocuries per liter). County/Parish Covered: Zipcode(s) Covered: State(s) Covered: Santa Clara (CA) Campbell CA: 95008 San Jose CA: 95124 CA Target Property Geometry:Point Target Property Longitude(s)/Latitude(s): (-121.944918, 37.268474) USGS Quadrangle:San Jose West, CA Disclaimer - The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer’s interpretation of this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers and independent contractors cannot be held liable for actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. www.geo-search.com · phone: 888-396-0042 · fax: 512-472-9967 Federal, state, and local environmental records have been researched, resulting in the following list of recorded environmental liens and AUL's (activity and usage limitations) for the subject property having been found: ENVIRONMENTAL LIENS, IC s, LUC s, AUL s, & DEUR s 1 NONE FOUND 2 NONE FOUND 3 4 JUDGMENTS, LIENS 1 NO FOUND 2 3 4 OTHER INFORMATION: Order Number GS#64660 Effective Date 5-21-2015 Last name RIDGECREST GROUP INCORPORATED First name County SANTA CLARA Street address 1323 PARSONS AVE., CAMPBELL, CA. 95008 City CAMPBELL State CA Mailing address 3395 S. BASCOM AV CAMPBELL, CA. 95008-6711 Parcel number 414-37-008 Alternate APN Legal Description SINGLE FAMILY DWELLING APPENDIX G RADIUS MAP REPORT Radius Report Satellite view Target Property: Phase I Environmental Site Assessment 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Prepared For: IRC Environmental Consulting LLC Order #: 64660 Job #: 140210 Project #: 3325 Date: 03/28/2016 0 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property Summary 1 Database Summary 2 Database Radius Summary 7 Radius Map 1 11 Radius Map 2 12 Ortho Map 13 Topographic Map 14 Located Sites Summary 15 Elevation Summary 21 Unlocated Sites Summary 215 Environmental Records Definitions 217 Unlocatable Report See Attachment Zip Report See Attachment www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA)Environmental Records Definitions - TRIBALTable of Contents This report was designed by GeoSearch to meet or exceed the records search requirements of the All Appropriate Inquiries Rule (40 CFR §312.26) and the current version of the ASTM International E1527, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process or, if applicable, the custom requirements requested by the entity that ordered this report. The records and databases of records used to compile this report were collected from various federal,state and local governmental entities. It is the goal of GeoSearch to meet or exceed the 40 CFR §312.26 and E1527 requirements for updating records by using the best available technology. GeoSearch contacts the appropriate governmental entities on a recurring basis. Depending on the frequency with which a record source or database of records is updated by the governmental entity, the data used to prepare this report may be updated monthly, quarterly, semi-annually, or annually. The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer's interpretation of this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers And independent contractors cannot be held liable For actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA)Environmental Records Definitions - TRIBALTable of ContentsDisclaimer Target Property Information Phase I Environmental Site Assessment 1323 Parsons Ave Campbell, California 95008 Coordinates Point (-121.94491, 37.268474) 234 feet above sea level USGS Quadrangle San Jose West, CA Geographic Coverage Information County/Parish: Santa Clara (CA) ZipCode(s): Campbell CA: 95008 Los Gatos CA: 95032 San Jose CA: 95124 Radon * Target property is located in Radon Zone 2. Zone 2 areas have a predicted average indoor radon screening level between 2 and 4 pCi/L (picocuries per liter). 1 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property Summary FEDERAL LISTING Standard Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) EMERGENCY RESPONSE NOTIFICATION SYSTEM ERNSIA 0 0 TP/AP EMERGENCY RESPONSE NOTIFICATION SYSTEM ERNSID 0 0 TP/AP EMERGENCY RESPONSE NOTIFICATION SYSTEM ERNSCA 0 0 TP/AP EMERGENCY RESPONSE NOTIFICATION SYSTEM ERNSSD 0 0 TP/AP FEDERAL ENGINEERING INSTITUTIONAL CONTROL SITES EC 0 0 TP/AP LAND USE CONTROL INFORMATION SYSTEM LUCIS 0 0 TP/AP RCRA SITES WITH CONTROLS RCRASC 0 0 TP/AP NO LONGER REGULATED RCRA GENERATOR FACILITIES NLRRCRAG 0 0 0.1250 RESOURCE CONSERVATION & RECOVERY ACT - GENERATOR FACILITIES RCRAGR09 4 0 0.1250 RESOURCE CONSERVATION & RECOVERY ACT - NON- GENERATOR FACILITIES RCRANGR09 0 0 0.1250 BROWNFIELDS MANAGEMENT SYSTEM BF 0 0 0.5000 DELISTED NATIONAL PRIORITIES LIST DNPL 0 0 0.5000 NO LONGER REGULATED RCRA NON-CORRACTS TSD FACILITIES NLRRCRAT 0 0 0.5000 RESOURCE CONSERVATION & RECOVERY ACT - NON-CORRACTS TREATMENT, STORAGE & DISPOSAL FACILITIES RCRAT 0 0 0.5000 SUPERFUND ENTERPRISE MANAGEMENT SYSTEM SEMS 0 0 0.5000 SUPERFUND ENTERPRISE MANAGEMENT SYSTEM ARCHIVED SITE INVENTORY SEMSARCH 1 0 0.5000 NATIONAL PRIORITIES LIST NPL 0 0 1.0000 NO LONGER REGULATED RCRA CORRECTIVE ACTION FACILITIES NLRRCRAC 0 0 1.0000 PROPOSED NATIONAL PRIORITIES LIST PNPL 0 0 1.0000 RESOURCE CONSERVATION & RECOVERY ACT - CORRECTIVE ACTION FACILITIES RCRAC 0 0 1.0000 RESOURCE CONSERVATION & RECOVERY ACT - SUBJECT TO CORRECTIVE ACTION FACILITIES RCRASUBC 0 0 1.0000 SUB-TOTAL 5 0 Additional Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) AEROMETRIC INFORMATION RETRIEVAL SYSTEM / AIR FACILITY SUBSYSTEM AIRSAFS 0 0 TP/AP BIENNIAL REPORTING SYSTEM BRS 0 0 TP/AP CERCLIS LIENS SFLIENS 0 0 TP/AP 2 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase Summary Database Acronym Locatable Unlocatable Search Radius (miles) CLANDESTINE DRUG LABORATORY LOCATIONS CDL 0 0 TP/AP EPA DOCKET DATA DOCKETS 0 0 TP/AP FACILITY REGISTRY SYSTEM FRSSD 0 0 TP/AP FACILITY REGISTRY SYSTEM FRSID 0 0 TP/AP FACILITY REGISTRY SYSTEM FRSCA 1 0 TP/AP FACILITY REGISTRY SYSTEM FRSIA 0 0 TP/AP HAZARDOUS MATERIALS INCIDENT REPORTING SYSTEM HMIRSR09 0 0 TP/AP INTEGRATED COMPLIANCE INFORMATION SYSTEM (FORMERLY DOCKETS) ICIS 0 0 TP/AP INTEGRATED COMPLIANCE INFORMATION SYSTEM NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM ICISNPDES 0 0 TP/AP MATERIAL LICENSING TRACKING SYSTEM MLTS 0 0 TP/AP NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM NPDESR09 0 0 TP/AP PCB ACTIVITY DATABASE SYSTEM PADS 0 0 TP/AP PERMIT COMPLIANCE SYSTEM PCSR09 0 0 TP/AP SECTION SEVEN TRACKING SYSTEM SSTS 0 0 TP/AP TOXIC SUBSTANCE CONTROL ACT INVENTORY TSCA 0 0 TP/AP TOXICS RELEASE INVENTORY TRI 0 0 TP/AP HISTORICAL GAS STATIONS HISTPST 0 0 0.2500 OPEN DUMP INVENTORY ODI 0 0 0.5000 DEPARTMENT OF DEFENSE SITES DOD 0 0 1.0000 FORMERLY USED DEFENSE SITES FUDS 0 0 1.0000 RECORD OF DECISION SYSTEM RODS 0 0 1.0000 SUB-TOTAL 1 0 3 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase Summary STATE (CA) LISTING Standard Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) DTSC DEED RESTRICTIONS DTSCDR 0 0 TP/AP ABOVE GROUND STORAGE TANKS ABST 1 0 0.2500 HISTORICAL UNDERGROUND STORAGE TANKS HISTUST 10 0 0.2500 STATEWIDE ENVIRONMENTAL EVALUATION AND PLANNING SYSTEM SWEEPS 11 0 0.2500 UNDERGROUND STORAGE TANKS USTCUPA 2 0 0.2500 CALSITES DATABASE CALSITES 1 0 0.5000 GEOTRACKER CLEANUP SITES CLEANUPSITES 25 0 0.5000 LEAKING UNDERGROUND STORAGE TANKS LUST 24 0 0.5000 SOLID WASTE INFORMATION SYSTEM SITES SWIS 0 0 0.5000 VOLUNTARY CLEANUP PROGRAM VCP 0 0 0.5000 ENVIROSTOR CLEANUP SITES ENVIROSTOR 5 0 1.0000 ENVIROSTOR PERMITTED AND CORRECTIVE ACTION SITES ENVIROSTORPCA 0 0 1.0000 SUB-TOTAL 79 0 Additional Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) CALIFORNIA HAZARDOUS MATERIAL INCIDENT REPORT SYSTEM CHMIRS 0 0 TP/AP CLANDESTINE DRUG LABS CDL 0 0 TP/AP EMISSIONS INVENTORY DATA EMI 0 0 TP/AP HAZARDOUS WASTE TANNER SUMMARY HWTS 3 0 TP/AP NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM FACILITIES NPDES 0 0 TP/AP RECORDED ENVIRONMENTAL CLEANUP LIENS LIENS 0 0 TP/AP CALIFORNIA MEDICAL WASTE MANAGEMENT PROGRAM FACILITY LIST MWMP 0 0 0.2500 DTSC REGISTERED HAZARDOUS WASTE TRANSPORTERS DTSCHWT 0 0 0.2500 DRY CLEANER FACILITIES CLEANER 0 0 0.2500 SPILLS, LEAKS, INVESTIGATION & CLEANUP RECOVERY LISTING SLIC 0 0 0.2500 CORTESE LIST CORTESE 17 0 0.5000 EXPEDITED REMOVAL ACTION PROGRAM SITES ERAP 0 0 0.5000 LISTING OF CERTIFIED PROCESSORS PROC 0 0 0.5000 NO FURTHER ACTION DETERMINATION NFA 0 0 0.5000 4 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase Summary Database Acronym Locatable Unlocatable Search Radius (miles) RECYCLING CENTERS SWRCY 0 0 0.5000 REFERRED TO ANOTHER LOCAL OR STATE AGENCY REF 1 0 0.5000 SCHOOL PROPERTY EVALUATIONS SCH 0 0 0.5000 SITES NEEDING FURTHER EVALUATION NFE 0 0 0.5000 WASTE MANAGEMENT UNIT DATABASE WMUDS 0 1 0.5000 TOXIC PITS CLEANUP ACT SITES TOXPITS 0 0 1.0000 SUB-TOTAL 21 1 5 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase Summary TRIBAL LISTING Standard Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) UNDERGROUND STORAGE TANKS ON TRIBAL LANDS USTR09 0 0 0.2500 LEAKING UNDERGROUND STORAGE TANKS ON TRIBAL LANDS LUSTR09 0 0 0.5000 OPEN DUMP INVENTORY ON TRIBAL LANDS ODINDIAN 0 0 0.5000 SUB-TOTAL 0 0 Additional Environmental Records Database Acronym Locatable Unlocatable Search Radius (miles) INDIAN RESERVATIONS INDIANRES 0 0 1.0000 SUB-TOTAL 0 0 TOTAL 106 1 6 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase Summary FEDERAL LISTING Standard environmental records are displayed in bold. Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2) > 1 Mile Total AIRSAFS 0.0200 0 NS NS NS NS NS 0 BRS 0.0200 0 NS NS NS NS NS 0 CDL 0.0200 0 NS NS NS NS NS 0 DOCKETS 0.0200 0 NS NS NS NS NS 0 EC 0.0200 0 NS NS NS NS NS 0 ERNSCA 0.0200 0 NS NS NS NS NS 0 ERNSIA 0.0200 0 NS NS NS NS NS 0 ERNSID 0.0200 0 NS NS NS NS NS 0 ERNSSD 0.0200 0 NS NS NS NS NS 0 FRSCA 0.0200 1 NS NS NS NS NS 1 FRSIA 0.0200 0 NS NS NS NS NS 0 FRSID 0.0200 0 NS NS NS NS NS 0 FRSSD 0.0200 0 NS NS NS NS NS 0 HMIRSR09 0.0200 0 NS NS NS NS NS 0 ICIS 0.0200 0 NS NS NS NS NS 0 ICISNPDES 0.0200 0 NS NS NS NS NS 0 LUCIS 0.0200 0 NS NS NS NS NS 0 MLTS 0.0200 0 NS NS NS NS NS 0 NPDESR09 0.0200 0 NS NS NS NS NS 0 PADS 0.0200 0 NS NS NS NS NS 0 PCSR09 0.0200 0 NS NS NS NS NS 0 RCRASC 0.0200 0 NS NS NS NS NS 0 SFLIENS 0.0200 0 NS NS NS NS NS 0 SSTS 0.0200 0 NS NS NS NS NS 0 TRI 0.0200 0 NS NS NS NS NS 0 TSCA 0.0200 0 NS NS NS NS NS 0 NLRRCRAG 0.1250 0 0 NS NS NS NS 0 RCRAGR09 0.1250 0 4 NS NS NS NS 4 RCRANGR09 0.1250 0 0 NS NS NS NS 0 HISTPST 0.2500 0 0 0 NS NS NS 0 BF 0.5000 0 0 0 0 NS NS 0 DNPL 0.5000 0 0 0 0 NS NS 0 NLRRCRAT 0.5000 0 0 0 0 NS NS 0 ODI 0.5000 0 0 0 0 NS NS 0 RCRAT 0.5000 0 0 0 0 NS NS 0 7 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius Summary Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2) > 1 Mile Total SEMS 0.5000 0 0 0 0 NS NS 0 SEMSARCH 0.5000 0 0 0 1 NS NS 1 DOD 1.0000 0 0 0 0 0 NS 0 FUDS 1.0000 0 0 0 0 0 NS 0 NLRRCRAC 1.0000 0 0 0 0 0 NS 0 NPL 1.0000 0 0 0 0 0 NS 0 PNPL 1.0000 0 0 0 0 0 NS 0 RCRAC 1.0000 0 0 0 0 0 NS 0 RCRASUBC 1.0000 0 0 0 0 0 NS 0 RODS 1.0000 0 0 0 0 0 NS 0 SUB-TOTAL 1 4 0 1 0 0 6 8 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius Summary STATE (CA) LISTING Standard environmental records are displayed in bold. Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2) > 1 Mile Total CDL 0.0200 0 NS NS NS NS NS 0 CHMIRS 0.0200 0 NS NS NS NS NS 0 DTSCDR 0.0200 0 NS NS NS NS NS 0 EMI 0.0200 0 NS NS NS NS NS 0 HWTS 0.0200 3 NS NS NS NS NS 3 LIENS 0.0200 0 NS NS NS NS NS 0 NPDES 0.0200 0 NS NS NS NS NS 0 ABST 0.2500 1 0 0 NS NS NS 1 CLEANER 0.2500 0 0 0 NS NS NS 0 DTSCHWT 0.2500 0 0 0 NS NS NS 0 HISTUST 0.2500 0 4 6 NS NS NS 10 MWMP 0.2500 0 0 0 NS NS NS 0 SLIC 0.2500 0 0 0 NS NS NS 0 SWEEPS 0.2500 1 4 6 NS NS NS 11 USTCUPA 0.2500 0 1 1 NS NS NS 2 CALSITES 0.5000 0 0 0 1 NS NS 1 CLEANUPSITES 0.5000 1 5 4 15 NS NS 25 CORTESE 0.5000 1 3 4 9 NS NS 17 ERAP 0.5000 0 0 0 0 NS NS 0 LUST 0.5000 2 4 4 14 NS NS 24 NFA 0.5000 0 0 0 0 NS NS 0 NFE 0.5000 0 0 0 0 NS NS 0 PROC 0.5000 0 0 0 0 NS NS 0 REF 0.5000 0 0 0 1 NS NS 1 SCH 0.5000 0 0 0 0 NS NS 0 SWIS 0.5000 0 0 0 0 NS NS 0 SWRCY 0.5000 0 0 0 0 NS NS 0 VCP 0.5000 0 0 0 0 NS NS 0 WMUDS 0.5000 0 0 0 0 NS NS 0 ENVIROSTOR 1.0000 0 0 0 1 4 NS 5 ENVIROSTORPCA 1.0000 0 0 0 0 0 NS 0 TOXPITS 1.0000 0 0 0 0 0 NS 0 SUB-TOTAL 9 21 25 41 4 0 100 9 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius Summary TRIBAL LISTING Standard environmental records are displayed in bold. Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2) > 1 Mile Total USTR09 0.2500 0 0 0 NS NS NS 0 LUSTR09 0.5000 0 0 0 0 NS NS 0 ODINDIAN 0.5000 0 0 0 0 NS NS 0 INDIANRES 1.0000 0 0 0 0 0 NS 0 SUB-TOTAL 0 0 0 0 0 0 0 TOTAL 10 25 25 42 4 0 106 NOTES: NS = NOT SEARCHED TP/AP = TARGET PROPERTY/ADJACENT PROPERTY 10 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius Summary .2 Click here to access Satellite view 11 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryRadius Map 1 .3 Click here to access Satellite view 12 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryRadius Map 2 .4 Click here to access Satellite view 13 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryOrtho Map .5 Click here to access Satellite view 14 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryTopographic Map NOTE: Standard environmental records are displayed in bold. Map ID# Database Name Site ID#Relative Elevation Distance From Site Site Name Address PAGE # 1 CLEANUPSITE S T0608500295 Lower (233 ft.) 0.018 mi. E (95 ft.) JIFFY LUBE 1387 CAMDEN AVE., CAMPBELL, CA 95008 24 1 CORTESE 43-0749 Lower (233 ft.) 0.018 mi. E (95 ft.) JIFFY LUBE 1387 CAMDEN, CAMPBELL, CA 28 1 HWTS CAL000336609 Lower (233 ft.) 0.018 mi. E (95 ft.) JIFFY LUBE # 297 1387 CAMDEN AVE, CAMPBELL, CA 95008 29 1 HWTS CAC000085381 Lower (233 ft.) 0.018 mi. E (95 ft.) 1X JIFFY LUBE CORP. 1387 CAMDEN AVE., CAMPBELL, CA 95008 33 1 HWTS CAD982326894 Lower (233 ft.) 0.018 mi. E (95 ft.) JIFFY LUBE #297 1387 CAMDEN AVE, CAMPBELL, CA 95008 34 1 LUST T0608500295 Lower (233 ft.) 0.018 mi. E (95 ft.) JIFFY LUBE 1387 CAMDEN, CAMPBELL, CA 95008 40 1 LUST T0608500775 Lower (233 ft.) 0.018 mi. E (95 ft.) JIFFY LUBE 1387 CAMDEN AVE, CAMPBELL, CA 95008 42 1 SWEEPS I43-008-67261 Lower (233 ft.) 0.018 mi. E (95 ft.) JIFFY LUBE 1387 CAMDEN AVE, CAMPBELL, CA 95008 44 1 FRSCA 110017963097 Lower (233 ft.) 0.018 mi. E (95 ft.) JIFFY LUBE #0297 1387 CAMDEN AVE, CAMPBELL, CA 95008 45 1 ABST 985047222 Lower (233 ft.) 0.018 mi. E (95 ft.) JIFFY LUBE #297 1387 CAMDEN AVE., CAMPBELL, CA 95008 46 2 CORTESE 43-0156 Lower (232 ft.) 0.06 mi. NE (317 ft.) BEACON 1370 CAMDEN, SAN JOSE, CA 95008 47 2 LUST T0608500222 Lower (232 ft.) 0.06 mi. NE (317 ft.) BEACON 1370 CAMDEN, CAMPBELL, CA 95008 48 2 SWEEPS A43-000-934 Lower (232 ft.) 0.06 mi. NE (317 ft.) BEACON STATION #420 1370 CAMDEN, CAMPBELL, CA 95008 50 2 USTCUPA 333215838 Lower (232 ft.) 0.06 mi. NE (317 ft.) BEACON (CAMPBELL) 1370 CAMDEN AV., CAMPBELL, CA 95008 51 2 RCRAGR09 CAR000142364 Lower (232 ft.) 0.06 mi. NE (317 ft.) TESORO WEST COAST CO LLC 68117 1370 CAMDEN AVE, CAMPBELL, CA 95008 52 2 CLEANUPSITE S T0608500222 Lower (232 ft.) 0.06 mi. NE (317 ft.) BEACON - 1370 CAMDEN 1370 CAMDEN AVENUE, CAMPBELL, CA 95008 54 3 CLEANUPSITE S T0608500344 Lower (231 ft.) 0.065 mi. E (343 ft.) CHEVRON #9-8354 1402 CAMDEN AVENUE, CAMPBELL, CA 95008 61 3 CORTESE 43-0287 Lower (231 ft.) 0.065 mi. E (343 ft.) CHEVRON 1402 CAMDEN, CAMPBELL, CA 94583 66 3 HISTUST 0002CFCC Lower (231 ft.) 0.065 mi. E (343 ft.) LARWAY CHEVRON 1402 CAMDEN AVE, CAMPBELL, CA 95008 67 3 HISTUST 0002D09B Lower (231 ft.) 0.065 mi. E (343 ft.) 98354 1402 CAMDEN AVE, CAMPBELL, CA 95008 70 3 LUST T0608500344 Lower (231 ft.) 0.065 mi. E (343 ft.) CHEVRON #9-8354 1402 CAMDEN, CAMPBELL, CA 95008 73 3 LUST T0608502222 Lower (231 ft.) 0.065 mi. E (343 ft.) CHEVRON #9-8354 1402 CAMDEN AVE, SAN JOSE, CA 95124 75 3 SWEEPS A43-000-23460 Lower (231 ft.) 0.065 mi. E (343 ft.) CHEVRON #8354 1402 CAMDEN AVE, CAMPBELL, CA 95008 77 3 RCRAGR09 CAR000249425 Lower (231 ft.) 0.065 mi. E (343 ft.) CHEVRON 98354 1402 CAMDEN AVE, CAMPBELL, CA 95008 78 3 CLEANUPSITE S T0608502222 Lower (231 ft.) 0.065 mi. E (343 ft.) CHEVRON #9-8354 1402 CAMDEN AVE, SAN JOSE, CA 95124 80 15 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary 4 CORTESE 43-0003 Equal (234 ft.) 0.067 mi. NW (354 ft.) 4 DAY TIRE STORE 1311 CAMDEN, CAMPBELL, CA 82 4 HISTUST 00020976 Equal (234 ft.) 0.067 mi. NW (354 ft.) TERRIBLE HERBST 77 1311 CAMDEN AVE, CAMPBELL, CA 95008 83 4 LUST T0608500075 Equal (234 ft.) 0.067 mi. NW (354 ft.) 4 DAY TIRE STORE 1311 CAMDEN AVE, CAMPBELL, CA 95008 85 4 SWEEPS I43-008-14186 Equal (234 ft.) 0.067 mi. NW (354 ft.) TERRIBLE HERBST #77 1311 CAMDEN AVE, CAMPBELL, CA 95008 87 4 CLEANUPSITE S T0608500075 Equal (234 ft.) 0.067 mi. NW (354 ft.) 4 DAY TIRE STORE 1311 CAMDEN AVE, CAMPBELL, CA 95008 88 5 HISTUST 000209DF Higher (236 ft.) 0.082 mi. W (433 ft.) CAMPBELL M C 1266 WHITE OAKS, CAMPBELL, CA 95008 90 5 SWEEPS A43-008-28646 Higher (236 ft.) 0.082 mi. W (433 ft.) CAMPBELL CENTER 1266 WHITE OAKS AVE, CAMPBELL, CA 95008 92 5 CLEANUPSITE S T10000005716 Higher (236 ft.) 0.096 mi. NW (507 ft.) MIDAS 1236 WHITE OAKS, CAMPBELL, CA 95008 93 6 RCRAGR09 CAD052173705 Higher (241 ft.) 0.122 mi. SW (644 ft.) MATHEWS & ASSOC DBA MIRACLE PAINT 1360 WHITEOAKS RD, CAMPBELL, CA 95008 95 6 RCRAGR09 CAD983615717 Higher (241 ft.) 0.122 mi. SW (644 ft.) AUTO LECTRICS 1360 WHITE OAKS RD D, CAMPBELL, CA 95008 97 7 CORTESE 43-1356 Higher (238 ft.) 0.207 mi. SE (1093 ft.) SMOG DOCTOR 2270 CAMDEN, SAN JOSE, CA 95008 99 7 HISTUST 00020676 Higher (238 ft.) 0.207 mi. SE (1093 ft.) FILLEM UP 2270 CAMDEN AVE, CAMPBELL, CA 95008 100 7 HISTUST 0002CE40 Higher (238 ft.) 0.207 mi. SE (1093 ft.) PERFECT TIMING 2270 CAMDEN AVE, CAMPBELL, CA 95008 103 7 LUST T0608501333 Higher (238 ft.) 0.207 mi. SE (1093 ft.) SMOG DOCTOR 2270 CAMDEN AVE, SAN JOSE, CA 95124 106 7 SWEEPS I43-060-401681 Higher (238 ft.) 0.207 mi. SE (1093 ft.) SMOG DOCTOR INC 2270 CAMDEN AVE, SAN JOSE, CA 95124 108 7 SWEEPS A43-000-42885 Higher (238 ft.) 0.207 mi. SE (1093 ft.) PERFECT TIMING 2270 CAMDEN AVE, CAMPBELL, CA 95008 109 7 CLEANUPSITE S T0608501333 Higher (238 ft.) 0.207 mi. SE (1093 ft.) SMOG DOCTOR 2270 CAMDEN AVE, SAN JOSE, CA 95124 110 8 SWEEPS I43-008-19207 Lower (230 ft.) 0.221 mi. N (1167 ft.) SOUTH BAY GUNITE, INC 110 CURTNER AVE, CAMPBELL, CA 95008 112 8 HISTUST 00020918 Lower (230 ft.) 0.221 mi. N (1167 ft.) SOUTH BAY GUNITE INC 110 CURTNER AV, CAMPBELL, CA 95008 113 9 SWEEPS A43-008-17719 Higher (245 ft.) 0.239 mi. SW (1262 ft.) SERVICAR 1506 WHITE OAKS RD, CAMPBELL, CA 95008 116 9 USTCUPA 2689310899 Higher (245 ft.) 0.239 mi. SW (1262 ft.) DURHAM TRANSPORTATION 1506 WHITE OAKS RD, CAMPBELL, CA 95008 117 9 HISTUST 000207D7 Higher (245 ft.) 0.239 mi. SW (1262 ft.) SERVICAR 1506 WHITE OAKS RD, CAMPBELL, CA 95008 118 10 CLEANUPSITE S T0608501521 Higher (237 ft.) 0.246 mi. SE (1299 ft.) UNOCAL #4328 3145 S BASCOM AVE, SAN JOSE, CA 95101 120 10 CORTESE 43-1559 Higher (237 ft.) 0.246 mi. SE (1299 ft.) UNOCAL 3145 BASCOM, CAMPBELL, CA 95008 122 10 CORTESE 43-2109 Higher (237 ft.) 0.246 mi. SE (1299 ft.) UNOCAL 3145 B BASCOM, SAN JOSE, CA 123 10 HISTUST 00020A04 Higher (237 ft.) 0.246 mi. SE (1299 ft.) UNION OIL SS 4328 3145 SOUTH BASCAM, CAMPBELL, CA 95008 124 16 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary 10 LUST T0608501937 Higher (237 ft.) 0.246 mi. SE (1299 ft.) UNOCAL #4328 3145 S BASCOM AVE, SAN JOSE, CA 95101 127 10 LUST T0608501521 Higher (237 ft.) 0.246 mi. SE (1299 ft.) UNOCAL #4328 3145 S BASCOM AVE, SAN JOSE, CA 95101 129 10 SWEEPS I43-060-400890 Higher (237 ft.) 0.246 mi. SE (1299 ft.) UNION 76 3145 S BASCOM AVE, SAN JOSE, CA 95008 131 10 SWEEPS A43-060- 400890 Higher (237 ft.) 0.246 mi. SE (1299 ft.) UNION 76 3145 S BASCOM AVE, SAN JOSE, CA 95008 132 10 CLEANUPSITE S T0608501937 Higher (237 ft.) 0.246 mi. SE (1299 ft.) UNOCAL #4328 3145 S BASCOM AVE, SAN JOSE, CA 95101 133 11 CORTESE 43-0236 Higher (241 ft.) 0.249 mi. SE (1315 ft.) CAMBRIAN NURSERY 3175 BASCOM, SAN JOSE, CA 135 11 HISTUST 0002CF71 Higher (241 ft.) 0.249 mi. SE (1315 ft.) CAMBRIAN NURSERY AND FLORIST 3175 SOUTH BASCOM AVENUE, CAMPBELL, CA 95008 136 11 LUST T0608502223 Higher (241 ft.) 0.249 mi. SE (1315 ft.) CAMBRIAN NURSERY 3175 S BASCOM AVE, SAN JOSE, CA 95101 138 11 CLEANUPSITE S T0608502223 Higher (241 ft.) 0.249 mi. SE (1315 ft.) CAMBRIAN NURSERY 3175 S BASCOM AVE, SAN JOSE, CA 95101 140 12 CLEANUPSITE S T0608501827 Higher (240 ft.) 0.29 mi. SE (1531 ft.) CHEVRON 3160 BASCOM AVE S, SAN JOSE, CA 95124 142 12 CORTESE 43-1975 Higher (240 ft.) 0.29 mi. SE (1531 ft.) CHEVRON 3160 BASCOM, SAN JOSE, CA 144 12 LUST T0608535477 Higher (240 ft.) 0.29 mi. SE (1531 ft.) CHEVRON #9-0835 3160 BASCOM, SAN JOSE, CA 95124 145 12 LUST T0608501827 Higher (240 ft.) 0.29 mi. SE (1531 ft.) CHEVRON 3160 BASCOM AVE S, SAN JOSE, CA 95124 147 12 CLEANUPSITE S T0608535477 Higher (240 ft.) 0.29 mi. SE (1531 ft.) CHEVRON #9-0835 3160 BASCOM AVENUE, SAN JOSE, CA 95124 149 13 CORTESE 43-1090 Higher (237 ft.) 0.292 mi. SE (1542 ft.) QUALITY TUNE UP 3146 BASCOM, SAN JOSE, CA 95124 152 13 LUST T0608501082 Higher (237 ft.) 0.292 mi. SE (1542 ft.) QUALITY TUNE-UP #4 3146 S BASCOM AVE, SAN JOSE, CA 95118 153 13 CLEANUPSITE S T0608501082 Higher (237 ft.) 0.291 mi. SE (1536 ft.) QUALITY TUNE-UP #4 3146 S BASCOM AVE, SAN JOSE, CA 95118 155 14 CORTESE 43-2205 Higher (245 ft.) 0.319 mi. SE (1684 ft.) CROFT EQUIPMENT RENTALS 3260 BASCOM, SAN JOSE, CA 95124 157 14 LUST T0608598719 Higher (245 ft.) 0.319 mi. SE (1684 ft.) CROFT EQUIPMENT RENTALS 3260 BASCOM AVE, SAN JOSE, CA 95124 158 14 LUST T0608502023 Higher (245 ft.) 0.319 mi. SE (1684 ft.) CROFT EQUIPMENT RENTALS 3260 BASCOM AVE S, SAN JOSE, CA 95124 160 14 CLEANUPSITE S T0608598719 Higher (245 ft.) 0.319 mi. SE (1684 ft.) CROFT EQUIPMENT RENTALS 3260 BASCOM AVE, SAN JOSE, CA 95124 162 15 LUST T0608578224 Lower (230 ft.) 0.378 mi. NW (1996 ft.) WEST VALLEY SANITATION DIST 100 E SUNNYOAKS AVE, CAMPBELL, CA 95008 164 15 CLEANUPSITE S T0608578224 Lower (230 ft.) 0.378 mi. NW (1996 ft.) WEST VALLEY SANITATION DIST 100 E SUNNYOAKS AVE, CAMPBELL, CA 95008 166 16 CALSITES 43360018 Equal (234 ft.) 0.379 mi. W (2001 ft.) HAWKES MAGNETIC 1190 DELL AVENUE, CAMPBELL, CA 95008 168 16 REF 000043360018 Equal (234 ft.) 0.379 mi. W (2001 ft.) HAWKES MAGNETIC 1190 DELL AVENUE, CAMPBELL, CA 95008 169 16 SEMSARCH CAD981368400 Equal (234 ft.) 0.379 mi. W (2001 ft.) AMERICAN AUTOMATED INDUSTRIES 1190 DELL AVE, CAMPBELL, CA 95008 170 17 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary 16 ENVIROSTOR 43360018 Equal (234 ft.) 0.379 mi. W (2001 ft.) HAWKES MAGNETIC 1190 DELL AVENUE, CAMPBELL, CA 95008 171 17 CLEANUPSITE S T10000004235 Lower (223 ft.) 0.382 mi. N (2017 ft.) FORMER CALHOUN BROTHERS 910 S. MCGLINCY LANE, CAMPBELL, CA 95008 172 18 LUST T0608502119 Lower (223 ft.) 0.398 mi. N (2101 ft.) WSP TRUCKING 175 S CURTNER AVE, CAMPBELL, CA 95008 174 18 CLEANUPSITE S T0608502119 Lower (223 ft.) 0.397 mi. N (2096 ft.) WSP TRUCKING 175 S CURTNER AVE, CAMPBELL, CA 95008 176 19 CORTESE 43-0985 Lower (222 ft.) 0.402 mi. N (2123 ft.) HOUGE CONSTRUCTION 210 VIETENHIEMER, CAMPBELL, CA 95008 178 19 LUST T0608521523 Lower (222 ft.) 0.402 mi. N (2123 ft.) HOUGE CONSTRUCTION 210 VEITENHEIMER DR, CAMPBELL, CA 95008 179 19 LUST T0608500984 Lower (222 ft.) 0.402 mi. N (2123 ft.) HOUGE CONSTRUCTION 210 VIETENHIEMER DR, CAMPBELL, CA 95008 181 19 CLEANUPSITE S T0608521523 Lower (222 ft.) 0.402 mi. N (2123 ft.) HOUGE CONSTRUCTION 210 VEITENHEIMER DR, CAMPBELL, CA 95008 183 20 CORTESE 43-2168 Lower (228 ft.) 0.42 mi. NW (2218 ft.) SPECIALTY DETAIL 951 CAMDEN, CAMPBELL, CA 95008 185 20 LUST T0608501992 Lower (228 ft.) 0.42 mi. NW (2218 ft.) SPECIALTY DETAIL 951 CAMDEN AVE, CAMPBELL, CA 95008 186 20 CLEANUPSITE S T0608501992 Lower (228 ft.) 0.419 mi. NW (2212 ft.) SPECIALTY DETAIL 951 CAMDEN AVE, CAMPBELL, CA 95008 188 21 CORTESE 43-0242 Higher (238 ft.) 0.445 mi. SE (2350 ft.) CAMPBELL UNIFIED SCHOOL D 2225 CAMDEN, SAN JOSE, CA 190 21 LUST T0608500301 Higher (238 ft.) 0.445 mi. SE (2350 ft.) CAMPBELL UNIFIED SCHOOL DISTRICT 2225 CAMDEN AVE, SAN JOSE, CA 95124 191 21 CLEANUPSITE S T0608500301 Higher (238 ft.) 0.445 mi. SE (2350 ft.) CAMPBELL UNIFIED SCHOOL DISTRICT 2225 CAMDEN AVE, SAN JOSE, CA 95124 193 22 CORTESE 43-0648 Lower (231 ft.) 0.449 mi. W (2371 ft.) GLAGE UNDERGROUND CONSTRU 1116 DELL, CAMPBELL, CA 95008 195 22 LUST T0608500682 Lower (231 ft.) 0.449 mi. W (2371 ft.) GLAGE UNDERGROUND CONSTRUCTION 1116 DELL AVE, CAMPBELL, CA 95008 196 22 CLEANUPSITE S T0608500682 Lower (231 ft.) 0.449 mi. W (2371 ft.) GLAGE UNDERGROUND CONSTRUCTION 1116 DELL AVE, CAMPBELL, CA 95008 198 23 CORTESE 43-0167 Lower (221 ft.) 0.452 mi. N (2387 ft.) MELLO PIPELINES 260 MCGLINCEY, CAMPBELL, CA 95008 200 23 LUST T0608500233 Lower (221 ft.) 0.452 mi. N (2387 ft.) MELLO PIPELINES 260 MCGLINCEY LN, CAMPBELL, CA 95008 201 23 CLEANUPSITE S T0608500233 Lower (221 ft.) 0.452 mi. N (2387 ft.) MELLO PIPELINES 260 MCGLINCEY LN, CAMPBELL, CA 95008 203 24 CORTESE 43-0786 Lower (232 ft.) 0.454 mi. W (2397 ft.) KILROY PEST CONTROL 1175 DELL, CAMPBELL, CA 95008 205 24 LUST T0608500805 Lower (232 ft.) 0.454 mi. W (2397 ft.) KILROY PEST CONTROL 1175 DELL AVE, CAMPBELL, CA 95008 206 24 CLEANUPSITE S T0608500805 Lower (232 ft.) 0.454 mi. W (2397 ft.) KILROY PEST CONTROL 1175 DELL AVE, CAMPBELL, CA 95008 208 25 CLEANUPSITE S T10000007802 Lower (231 ft.) 0.494 mi. W (2608 ft.) VSL CORPORATION 1077 DELL AVENUE, CAMPBELL, CA 95008 210 25 CLEANUPSITE S T10000007803 Lower (231 ft.) 0.494 mi. W (2608 ft.) VSL CORPORATION 1077 DELL AVENUE, CAMPBELL, CA 95008 211 18 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary 26 ENVIROSTOR 71002130 Lower (220 ft.) 0.507 mi. N (2677 ft.) PACIFIC AEROSPACE SVCS., INC. 354 MCGLINCEY LANE, CAMPBELL, CA 95008 212 26 ENVIROSTOR 60000368 Lower (220 ft.) 0.507 mi. N (2677 ft.) PACIFIC AEROSPACE SERVICES 354 EAST MCGLINCEY LANE, CAMPBELL, CA 95008 213 27 ENVIROSTOR 71003078 Higher (248 ft.) 0.711 mi. SW (3754 ft.) ASHLAND CHEMICAL CO., CAMPBELL 1600 DELL AVENUE, CAMPBELL, CA 95008 214 28 ENVIROSTOR 71003650 Higher (263 ft.) 0.962 mi. SW (5079 ft.) SILICON GENESIS CORP. 590 DIVISION STREET, CAMPBELL, CA 95008 215 19 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites Summary Elevations are collected from the USGS 3D Elevation Program 1/3 arc-second (approximately 10 meters) layer hosted at the NGTOC. . Target Property Elevation: 234 ft. NOTE: Standard environmental records are displayed in bold. EQUAL/HIGHER ELEVATION Map ID# Database Name Elevation Site Name Address Page # 1 CLEANUPSITES 233 ft. JIFFY LUBE 1387 CAMDEN AVE., CAMPBELL, CA 95008 24 1 CORTESE 233 ft. JIFFY LUBE 1387 CAMDEN, CAMPBELL, CA 28 1 HWTS 233 ft. JIFFY LUBE # 297 1387 CAMDEN AVE, CAMPBELL, CA 95008 29 1 HWTS 233 ft. 1X JIFFY LUBE CORP.1387 CAMDEN AVE., CAMPBELL, CA 95008 33 1 HWTS 233 ft. JIFFY LUBE #297 1387 CAMDEN AVE, CAMPBELL, CA 95008 34 1 LUST 233 ft. JIFFY LUBE 1387 CAMDEN, CAMPBELL, CA 95008 40 1 LUST 233 ft. JIFFY LUBE 1387 CAMDEN AVE, CAMPBELL, CA 95008 42 1 SWEEPS 233 ft. JIFFY LUBE 1387 CAMDEN AVE, CAMPBELL, CA 95008 44 1 FRSCA 233 ft. JIFFY LUBE #0297 1387 CAMDEN AVE, CAMPBELL, CA 95008 45 1 ABST 233 ft. JIFFY LUBE #297 1387 CAMDEN AVE., CAMPBELL, CA 95008 46 2 CORTESE 232 ft. BEACON 1370 CAMDEN, SAN JOSE, CA 95008 47 2 LUST 232 ft. BEACON 1370 CAMDEN, CAMPBELL, CA 95008 48 2 SWEEPS 232 ft. BEACON STATION #420 1370 CAMDEN, CAMPBELL, CA 95008 50 2 USTCUPA 232 ft. BEACON (CAMPBELL)1370 CAMDEN AV., CAMPBELL, CA 95008 51 2 RCRAGR09 232 ft. TESORO WEST COAST CO LLC 68117 1370 CAMDEN AVE, CAMPBELL, CA 95008 52 2 CLEANUPSITES 232 ft. BEACON - 1370 CAMDEN 1370 CAMDEN AVENUE, CAMPBELL, CA 95008 54 4 CORTESE 234 ft. 4 DAY TIRE STORE 1311 CAMDEN, CAMPBELL, CA 82 4 HISTUST 234 ft. TERRIBLE HERBST 77 1311 CAMDEN AVE, CAMPBELL, CA 95008 83 4 LUST 234 ft. 4 DAY TIRE STORE 1311 CAMDEN AVE, CAMPBELL, CA 95008 85 4 SWEEPS 234 ft. TERRIBLE HERBST #77 1311 CAMDEN AVE, CAMPBELL, CA 95008 87 4 CLEANUPSITES 234 ft. 4 DAY TIRE STORE 1311 CAMDEN AVE, CAMPBELL, CA 95008 88 5 HISTUST 236 ft. CAMPBELL M C 1266 WHITE OAKS, CAMPBELL, CA 95008 90 5 SWEEPS 236 ft. CAMPBELL CENTER 1266 WHITE OAKS AVE, CAMPBELL, CA 95008 92 5 CLEANUPSITES 236 ft. MIDAS 1236 WHITE OAKS, CAMPBELL, CA 95008 93 6 RCRAGR09 241 ft. MATHEWS & ASSOC DBA MIRACLE PAINT 1360 WHITEOAKS RD, CAMPBELL, CA 95008 95 20 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation Summary 6 RCRAGR09 241 ft. AUTO LECTRICS 1360 WHITE OAKS RD D, CAMPBELL, CA 95008 97 7 CORTESE 238 ft. SMOG DOCTOR 2270 CAMDEN, SAN JOSE, CA 95008 99 7 HISTUST 238 ft. FILLEM UP 2270 CAMDEN AVE, CAMPBELL, CA 95008 100 7 HISTUST 238 ft. PERFECT TIMING 2270 CAMDEN AVE, CAMPBELL, CA 95008 103 7 LUST 238 ft. SMOG DOCTOR 2270 CAMDEN AVE, SAN JOSE, CA 95124 106 7 SWEEPS 238 ft. SMOG DOCTOR INC 2270 CAMDEN AVE, SAN JOSE, CA 95124 108 7 SWEEPS 238 ft. PERFECT TIMING 2270 CAMDEN AVE, CAMPBELL, CA 95008 109 7 CLEANUPSITES 238 ft. SMOG DOCTOR 2270 CAMDEN AVE, SAN JOSE, CA 95124 110 9 SWEEPS 245 ft. SERVICAR 1506 WHITE OAKS RD, CAMPBELL, CA 95008 116 9 USTCUPA 245 ft. DURHAM TRANSPORTATION 1506 WHITE OAKS RD, CAMPBELL, CA 95008 117 9 HISTUST 245 ft. SERVICAR 1506 WHITE OAKS RD, CAMPBELL, CA 95008 118 10 CLEANUPSITES 237 ft. UNOCAL #4328 3145 S BASCOM AVE, SAN JOSE, CA 95101 120 10 CORTESE 237 ft. UNOCAL 3145 BASCOM, CAMPBELL, CA 95008 122 10 CORTESE 237 ft. UNOCAL 3145 B BASCOM, SAN JOSE, CA 123 10 HISTUST 237 ft. UNION OIL SS 4328 3145 SOUTH BASCAM, CAMPBELL, CA 95008 124 10 LUST 237 ft. UNOCAL #4328 3145 S BASCOM AVE, SAN JOSE, CA 95101 127 10 LUST 237 ft. UNOCAL #4328 3145 S BASCOM AVE, SAN JOSE, CA 95101 129 10 SWEEPS 237 ft. UNION 76 3145 S BASCOM AVE, SAN JOSE, CA 95008 131 10 SWEEPS 237 ft. UNION 76 3145 S BASCOM AVE, SAN JOSE, CA 95008 132 10 CLEANUPSITES 237 ft. UNOCAL #4328 3145 S BASCOM AVE, SAN JOSE, CA 95101 133 11 CORTESE 241 ft. CAMBRIAN NURSERY 3175 BASCOM, SAN JOSE, CA 135 11 HISTUST 241 ft. CAMBRIAN NURSERY AND FLORIST 3175 SOUTH BASCOM AVENUE, CAMPBELL, CA 95008 136 11 LUST 241 ft. CAMBRIAN NURSERY 3175 S BASCOM AVE, SAN JOSE, CA 95101 138 11 CLEANUPSITES 241 ft. CAMBRIAN NURSERY 3175 S BASCOM AVE, SAN JOSE, CA 95101 140 12 CLEANUPSITES 240 ft. CHEVRON 3160 BASCOM AVE S, SAN JOSE, CA 95124 142 12 CORTESE 240 ft. CHEVRON 3160 BASCOM, SAN JOSE, CA 144 12 LUST 240 ft. CHEVRON #9-0835 3160 BASCOM, SAN JOSE, CA 95124 145 12 LUST 240 ft. CHEVRON 3160 BASCOM AVE S, SAN JOSE, CA 95124 147 12 CLEANUPSITES 240 ft. CHEVRON #9-0835 3160 BASCOM AVENUE, SAN JOSE, CA 95124 149 21 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation Summary 13 CORTESE 237 ft. QUALITY TUNE UP 3146 BASCOM, SAN JOSE, CA 95124 152 13 LUST 237 ft. QUALITY TUNE-UP #4 3146 S BASCOM AVE, SAN JOSE, CA 95118 153 13 CLEANUPSITES 237 ft. QUALITY TUNE-UP #4 3146 S BASCOM AVE, SAN JOSE, CA 95118 155 14 CORTESE 245 ft. CROFT EQUIPMENT RENTALS 3260 BASCOM, SAN JOSE, CA 95124 157 14 LUST 245 ft. CROFT EQUIPMENT RENTALS 3260 BASCOM AVE, SAN JOSE, CA 95124 158 14 LUST 245 ft. CROFT EQUIPMENT RENTALS 3260 BASCOM AVE S, SAN JOSE, CA 95124 160 14 CLEANUPSITES 245 ft. CROFT EQUIPMENT RENTALS 3260 BASCOM AVE, SAN JOSE, CA 95124 162 16 CALSITES 234 ft. HAWKES MAGNETIC 1190 DELL AVENUE, CAMPBELL, CA 95008 168 16 REF 234 ft. HAWKES MAGNETIC 1190 DELL AVENUE, CAMPBELL, CA 95008 169 16 SEMSARCH 234 ft. AMERICAN AUTOMATED INDUSTRIES 1190 DELL AVE, CAMPBELL, CA 95008 170 16 ENVIROSTOR 234 ft. HAWKES MAGNETIC 1190 DELL AVENUE, CAMPBELL, CA 95008 171 21 CORTESE 238 ft. CAMPBELL UNIFIED SCHOOL D 2225 CAMDEN, SAN JOSE, CA 190 21 LUST 238 ft. CAMPBELL UNIFIED SCHOOL DISTRICT 2225 CAMDEN AVE, SAN JOSE, CA 95124 191 21 CLEANUPSITES 238 ft. CAMPBELL UNIFIED SCHOOL DISTRICT 2225 CAMDEN AVE, SAN JOSE, CA 95124 193 22 CORTESE 231 ft. GLAGE UNDERGROUND CONSTRU 1116 DELL, CAMPBELL, CA 95008 195 22 LUST 231 ft. GLAGE UNDERGROUND CONSTRUCTION 1116 DELL AVE, CAMPBELL, CA 95008 196 22 CLEANUPSITES 231 ft. GLAGE UNDERGROUND CONSTRUCTION 1116 DELL AVE, CAMPBELL, CA 95008 198 24 CORTESE 232 ft. KILROY PEST CONTROL 1175 DELL, CAMPBELL, CA 95008 205 24 LUST 232 ft. KILROY PEST CONTROL 1175 DELL AVE, CAMPBELL, CA 95008 206 24 CLEANUPSITES 232 ft. KILROY PEST CONTROL 1175 DELL AVE, CAMPBELL, CA 95008 208 27 ENVIROSTOR 248 ft. ASHLAND CHEMICAL CO., CAMPBELL 1600 DELL AVENUE, CAMPBELL, CA 95008 214 28 ENVIROSTOR 263 ft. SILICON GENESIS CORP.590 DIVISION STREET, CAMPBELL, CA 95008 215 LOWER ELEVATION Map ID# Database Name Elevation Site Name Address Page # 3 CLEANUPSITES 231 ft. CHEVRON #9-8354 1402 CAMDEN AVENUE, CAMPBELL, CA 95008 61 3 CORTESE 231 ft. CHEVRON 1402 CAMDEN, CAMPBELL, CA 94583 66 3 HISTUST 231 ft. LARWAY CHEVRON 1402 CAMDEN AVE, CAMPBELL, CA 95008 67 3 HISTUST 231 ft. 98354 1402 CAMDEN AVE, CAMPBELL, CA 95008 70 3 LUST 231 ft. CHEVRON #9-8354 1402 CAMDEN, CAMPBELL, CA 95008 73 3 LUST 231 ft. CHEVRON #9-8354 1402 CAMDEN AVE, SAN JOSE, CA 95124 75 22 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation Summary 3 SWEEPS 231 ft. CHEVRON #8354 1402 CAMDEN AVE, CAMPBELL, CA 95008 77 3 RCRAGR09 231 ft. CHEVRON 98354 1402 CAMDEN AVE, CAMPBELL, CA 95008 78 3 CLEANUPSITES 231 ft. CHEVRON #9-8354 1402 CAMDEN AVE, SAN JOSE, CA 95124 80 8 SWEEPS 230 ft. SOUTH BAY GUNITE, INC 110 CURTNER AVE, CAMPBELL, CA 95008 112 8 HISTUST 230 ft. SOUTH BAY GUNITE INC 110 CURTNER AV, CAMPBELL, CA 95008 113 15 LUST 230 ft. WEST VALLEY SANITATION DIST 100 E SUNNYOAKS AVE, CAMPBELL, CA 95008 164 15 CLEANUPSITES 230 ft. WEST VALLEY SANITATION DIST 100 E SUNNYOAKS AVE, CAMPBELL, CA 95008 166 17 CLEANUPSITES 223 ft. FORMER CALHOUN BROTHERS 910 S. MCGLINCY LANE, CAMPBELL, CA 95008 172 18 LUST 223 ft. WSP TRUCKING 175 S CURTNER AVE, CAMPBELL, CA 95008 174 18 CLEANUPSITES 223 ft. WSP TRUCKING 175 S CURTNER AVE, CAMPBELL, CA 95008 176 19 CORTESE 222 ft. HOUGE CONSTRUCTION 210 VIETENHIEMER, CAMPBELL, CA 95008 178 19 LUST 222 ft. HOUGE CONSTRUCTION 210 VEITENHEIMER DR, CAMPBELL, CA 95008 179 19 LUST 222 ft. HOUGE CONSTRUCTION 210 VIETENHIEMER DR, CAMPBELL, CA 95008 181 19 CLEANUPSITES 222 ft. HOUGE CONSTRUCTION 210 VEITENHEIMER DR, CAMPBELL, CA 95008 183 20 CORTESE 228 ft. SPECIALTY DETAIL 951 CAMDEN, CAMPBELL, CA 95008 185 20 LUST 228 ft. SPECIALTY DETAIL 951 CAMDEN AVE, CAMPBELL, CA 95008 186 20 CLEANUPSITES 228 ft. SPECIALTY DETAIL 951 CAMDEN AVE, CAMPBELL, CA 95008 188 23 CORTESE 221 ft. MELLO PIPELINES 260 MCGLINCEY, CAMPBELL, CA 95008 200 23 LUST 221 ft. MELLO PIPELINES 260 MCGLINCEY LN, CAMPBELL, CA 95008 201 23 CLEANUPSITES 221 ft. MELLO PIPELINES 260 MCGLINCEY LN, CAMPBELL, CA 95008 203 25 CLEANUPSITES 231 ft. VSL CORPORATION 1077 DELL AVENUE, CAMPBELL, CA 95008 210 25 CLEANUPSITES 231 ft. VSL CORPORATION 1077 DELL AVENUE, CAMPBELL, CA 95008 211 26 ENVIROSTOR 220 ft. PACIFIC AEROSPACE SVCS., INC. 354 MCGLINCEY LANE, CAMPBELL, CA 95008 212 26 ENVIROSTOR 220 ft. PACIFIC AEROSPACE SERVICES 354 EAST MCGLINCEY LANE, CAMPBELL, CA 95008 213 23 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation Summary MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608500295 BUSINESS NAME: JIFFY LUBE ADDRESS: 1387 CAMDEN AVE. CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: 12-022 STATUS: COMPLETED - CASE CLOSED 12/15/2014 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: OTHER GROUNDWATER (USES OTHER THAN DRINKING WATER) SITE HISTORY: 1987 SUBSURFACE INVESTIGATION: IN MARCH 1987, GILES ENGINEERING ASSOCIATES, INC. (GEA) DRILLED THREE SOIL BORINGS (B-1 THROUGH B-3) IN THE VICINITY OF THE UNDERGROUND STORAGE TANKS (USTS). GEA COLLECTED ONE SOIL SAMPLE FROM SOIL BORING B-3 AT A DEPTH OF 13.5 TO 15 FEET BELOW GRADE (FBG). NO TOTAL PETROLEUM HYDROCARBONS AS GASOLINE (TPHG) OR BENZENE WAS DETECTED IN THE SOIL SAMPLE. DETAILS OF THIS INVESTIGATION ARE PRESENTED IN GEAÆS APRIL 9, 1987 SUBSURFACE EXPLORATION AND CHEMICAL ANALYSIS. 1988 UST REMOVAL: IN MAY 1988, FULLER EXCAVATING AND DEMOLITION, INC. (FULLER) REMOVED TWO 8,000-GALLON USTS AND ONE 10,000-GALLON UST. GEA COLLECTED TWO SOIL SAMPLES, AND FULLER COLLECTED SIX SOIL SAMPLES FROM THE UST EXCAVATION. THE SOIL SAMPLES CONTAINED UP TO 1,100 MILLIGRAMS PER KILOGRAM (MG/KG) TPHG AND 0.13 MG/KG BENZENE. LIMITED OVER-EXCAVATION WAS PERFORMED IN THE SOUTHWEST PORTION OF THE UST EXCAVATION BASED ON FIELD OBSERVATIONS, AND FULLER REPORTEDLY COLLECTED ONE SOIL SAMPLE FOLLOWING OVER- EXCAVATION, WHICH CONTAINED 0.46 MG/KG TPHG. NO BENZENE WAS DETECTED IN THIS SAMPLE. THESE ACTIVITIES ARE DISCUSSED IN GEAÆS JUNE 25, 1988 UNDERGROUND STORAGE TANK REMOVAL AND JUNE 16, 1988 PETROLEUM HYDROCARBONS TEST RESULTS ADDENDUM LETTER AND JIFFY LUBE INTERNATIONAL, INC.ÆS JANUARY 9, 1990 REPORT OF INVESTIGATION AND REMOVAL OF UNDERGROUND FUEL STORAGE TANKS. 1997 SUBSURFACE INVESTIGATION: IN SEPTEMBER 1997, FLUOR DANIEL GTI, INC. (GTI) DRILLED TWO SOIL BORINGS (SB-1 AND SB-2) ADJACENT TO THE FORMER USTS. GTI COLLECTED SOIL SAMPLES FROM THE BORINGS WHICH CONTAINED UP TO 0.22 MG/KG METHYL TERTIARY- BUTYL ETHER (MTBE). NO TPHG OR BENZENE WAS DETECTED IN THE SOIL SAMPLES. GTIÆS OCTOBER 29, 1997 SOIL BORING SUMMARY REPORT PROVIDES INVESTIGATION DETAILS. 2000 SUBSURFACE INVESTIGATION AND REQUEST FOR CLOSURE: IN OCTOBER 2002, IT CORPORATION (IT) DRILLED TWO SOIL BORINGS (SB-3 AND SB-4) TO ASSESS GROUNDWATER QUALITY AT THE SITE. GRAB GROUNDWATER SAMPLES COLLECTED FROM THE BORINGS CONTAINED UP TO 890 MICROGRAMS PER LITER (ÁG/L) MTBE. BASED ON THESE RESULTS, IT REQUESTED CASE CLOSURE. DETAILS ARE PRESENTED IN ITÆS OCTOBER 23, 2000 ADDITIONAL SUBSURFACE INVESTIGATION REPORT AND REQUEST FOR CLOSURE. 2002 SUBSURFACE INVESTIGATION: IN APRIL 2002, URS CORPORATION (URS) DRILLED TWO SOIL BORINGS (MW-01 AND MW-03) TO APPROXIMATELY 91 FBG. ONE SOIL SAMPLE FROM THE BORINGS (MW-01 AT 65 FBG) 0.007 MG/KG MTBE. NO TPHG OR BENZENE WAS DETECTED IN SOIL SAMPLES AND NO MTBE WAS DETECTED IN THE OTHER SOIL SAMPLES. BASED ON THESE RESULTS, URS RECOMMENDED NO FURTHER ACTION. URSÆS APRIL 26, 2002 LETTER REPORT, SUBSURFACE CONTAMINANT INVESTIGATION DETAILS INVESTIGATION RESULTS. 2003 SUBSURFACE INVESTIGATION: IN APRIL 2003, URS INSTALLED THREE GROUNDWATER MONITORING WELLS (WW-1 THROUGH WW-3). PIEZOMETER WW-1P WAS NESTED IN THE WW-1 BORING AND SCREENED AT APPROXIMATELY 37 TO 47 FBG IN THE SHALLOWEST PERCHED 24 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES) WATER ZONE TO DETERMINE IF THE ZONE CONTAINED WATER. URSÆS MAY 16, 2003 REPORT, GROUNDWATER MONITORING WELL INSTALLATION AND QUARTERLY GROUNDWATER MONITORING PRESENTS WELL INSTALLATION DETAILS. 2003 - 2004 GROUNDWATER MONITORING: FROM MAY 2003 TO JUNE 2004, URS PERFORMED GROUNDWATER MONITORING. THE PERCHED WATER ZONES SCREENED BY THE SITE WELLS WERE FREQUENTLY DRY. GROUNDWATER SAMPLES CONTAINED UP TO 1,400 ÁG/L MTBE, 23 ÁG/L ETHYL TERTIARY-BUTYL ETHER, 6 ÁG/L TERTIARY-AMYL METHYL ETHER, AND 44 ÁG/L TERTIARY BUTYL ALCOHOL WERE DETECTED (IN GROUNDWATER SAMPLES FROM WELL WW-3). NO TPHG OR BTEX WAS DETECTED IN GROUNDWATER SAMPLES. WELL WW-3 IS LOCATED UP GRADIENT FROM ALL SITE SOURCES OF FUEL OXYGENATES. THESE RESULTS ARE PRESENTED IN URSÆS QUARTERLY GROUNDWATER SAMPLING AND ANALYSIS REPORTS SUBMITTED DURING 2003 AND 2004. 2008 CASE CLOSURE SUMMARY: GROUNDWATER & ENVIRONMENTAL SERVICES, INC. SUBMITTED A SITE CLOSURE SUMMARY ON AUGUST 27, 2008. OCTOBER 2011 SITE CONCEPTUAL MODEL AND CLOSURE REQUEST: CONESTOGA-ROVERS & ASSOCIATES (CRA) SUBMITTED A SITE CONCEPTUAL MODEL AND CLOSURE REQUEST ON OCTOBER 5, 2011. JANUARY 2013 SUBSURFACE INVESTIGATION REPORT: CRA INSTALLED TWO GROUNDWATER MONITORING WELLS (WW-4 AND WW-5). NO CONSTITUENTS OF CONCERN WERE DETECTED FROM ANY OF THE SOIL SAMPLES. CRA SUBMITTED A SUBSURFACE INVESTIGATION REPORT ON JANUARY 11, 2013. NO CONSTITUENTS OF CONCERN WERE REPORTED ABOVE THE LABORATORY DETECTION LIMITS DURING SUBSEQUENT GROUNDWATER SAMPLING FROM THE NEWLY INSTALLED WELLS. REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK BEGAN OTHER 01/01/50 LEAK DISCOVERY OTHER 01/01/50 LEAK REPORTED OTHER 01/01/50 LEAK STOPPED REMEDIATION 01/01/50 EXCAVATION RESPONSE 01/09/2015 WELL DESTRUCTION REPORT ENFORCEMENT 12/15/2014 CLOSURE/NO FURTHER ACTION LETTER ENFORCEMENT 10/10/2014 STAFF LETTER ENFORCEMENT 08/05/2014 NOTIFICATION - PUBLIC NOTICE OF CASE CLOSURE ENFORCEMENT 11/05/2013 STAFF LETTER RESPONSE 11/05/2013 CORRESPONDENCE RESPONSE 10/30/2013 MONITORING REPORT - SEMI-ANNUALLY RESPONSE 04/30/2013 MONITORING REPORT - SEMI-ANNUALLY ENFORCEMENT 01/17/2013 STAFF LETTER RESPONSE 01/11/2013 SOIL AND WATER INVESTIGATION REPORT ENFORCEMENT 06/15/2012 STAFF LETTER RESPONSE 06/01/2012 PRELIMINARY SITE ASSESSMENT WORKPLAN - ADDENDUM - REGULATOR RESPONDED ENFORCEMENT 03/28/2012 STAFF LETTER RESPONSE 10/05/2011 CONCEPTUAL SITE MODEL ENFORCEMENT 08/25/2011 STAFF LETTER ENFORCEMENT 08/23/2011 STAFF LETTER ENFORCEMENT 05/25/2011 STAFF LETTER ENFORCEMENT 12/17/2010 STAFF LETTER RESPONSE 08/27/2008 OTHER REPORT / DOCUMENT RESPONSE 09/13/2004 MONITORING REPORT - QUARTERLY RESPONSE 05/23/2003 VERBAL COMMUNICATION RESPONSE 05/16/2003 SOIL AND WATER INVESTIGATION REPORT RESPONSE 02/19/2003 WELL INSTALLATION WORKPLAN 25 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES) TYPE OF ACTION:DATE:ACTION: RESPONSE 12/21/2001 CORRESPONDENCE RESPONSE 10/18/2001 SOIL AND WATER INVESTIGATION WORKPLAN RESPONSE 09/18/2001 SOIL AND WATER INVESTIGATION WORKPLAN RESPONSE 07/13/2000 OTHER WORKPLAN RESPONSE 02/25/1999 SOIL AND WATER INVESTIGATION WORKPLAN RESPONSE 01/21/1999 CORRESPONDENCE ENFORCEMENT 12/18/1998 STAFF LETTER - #19900 RESPONSE 05/15/1997 SOIL AND WATER INVESTIGATION REPORT ENFORCEMENT 02/20/1997 STAFF LETTER - #19897 RESPONSE 01/15/1997 SOIL AND WATER INVESTIGATION WORKPLAN RESPONSE 01/14/1997 TANK REMOVAL REPORT / UST SAMPLING REPORT ENFORCEMENT 11/04/1996 STAFF LETTER - #19895 RESPONSE 05/30/1995 OTHER REPORT / DOCUMENT ENFORCEMENT 06/15/1993 NOTICE OF RESPONSIBILITY - #39394 OTHER 05/20/1988 LEAK REPORTED OTHER 05/18/1988 LEAK BEGAN OTHER 05/18/1988 LEAK DISCOVERY OTHER 05/18/1988 LEAK STOPPED RESPONSE 03/20/1988 UNAUTHORIZED RELEASE FORM RESPONSE 04/09/1987 PRELIMINARY SITE ASSESSMENT REPORT REMEDIATION 03/01/1987 EXCAVATION STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 12/15/2014 OPEN - ELIGIBLE FOR CLOSURE 11/04/2013 OPEN - VERIFICATION MONITORING 07/19/2013 OPEN - SITE ASSESSMENT 06/15/1993 OPEN - CASE BEGIN DATE 05/20/1988 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: AARON COSTA CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089181954 EMAIL: AARON.COSTA@DEH.SCCGOV.ORG 26 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES) ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: NOT REPORTED CITY: OAKLAND CONTACT NAME: JOHN WOLFENDEN CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: JWOLFENDEN@WATERBOARDS.CA.GOV Back to Report Summary 27 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) FACILITY INFORMATION ID#: 43-0749 NAME: JIFFY LUBE ADDRESS: 1387 CAMDEN CAMPBELL, CA Back to Report Summary 28 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) SITE INFORMATION CONTACT INFORMATION EPA ID: CAL000336609 CONTACT: DRU FANTICOLA NAME: JIFFY LUBE # 297 PHONE: (714) 444-4940 COUNTY: SANTA CLARA ADDRESS: 1422 EDINGER AVE STE 150 ADDRESS: 1387 CAMDEN AVE TUSTIN CA 927806299 CAMPBELL, CA 950086701 MANIFEST SUMMARY INFORMATION YEAR: 2014 TSD ID: CAD097030993 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: OTHER ORGANIC SOLIDS AMOUNT DISPOSED(TONS): 0.3995 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2014 TSD ID: CAT080012602 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SOLANO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 3.8781 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2014 TSD ID: CAT080013352 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.36279 DISPOSAL METHOD: OTHER RECOVERY OF RECLAMATION FOR REUSE INCLUDING ACID REGENERATION, ORGANICS RECOVERY ECT YEAR: 2014 TSD ID: NVT330010000 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: UNKNOWN WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.15 DISPOSAL METHOD: LANDFILL OR SURFACE IMPOUNDMENT THAT WILL BE CLOSED AS LANDFILL( TO INCLUDE ON-SITE TREATMENT AND/OR STABILIZATION) YEAR: 2013 TSD ID: CAT080012602 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SOLANO 29 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS) WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 3.3152 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2013 TSD ID: CAT080013352 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.2711 DISPOSAL METHOD: OTHER RECOVERY OF RECLAMATION FOR REUSE INCLUDING ACID REGENERATION, ORGANICS RECOVERY ECT YEAR: 2012 TSD ID: CAT080012602 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SOLANO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 3.6696 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2011 TSD ID: CAD097030993 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SANTA CLARA WASTE CATEGORY: OTHER ORGANIC SOLIDS AMOUNT DISPOSED(TONS): 0.0625 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2011 TSD ID: CAT080012602 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SANTA CLARA WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 5.4127 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2010 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: AQUEOUS SOLUTION WITH TOTAL ORGANIC RESIDUES 10 PERCENT OR MORE AMOUNT DISPOSED(TONS): 1.2093 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2010 TSD ID: CAD044003556 30 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS) GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 1.8974 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2010 TSD ID: CAT080012602 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SOLANO WASTE CATEGORY: AQUEOUS SOLUTION WITH TOTAL ORGANIC RESIDUES 10 PERCENT OR MORE AMOUNT DISPOSED(TONS): 0.8340 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2009 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: AQUEOUS SOLUTION WITH TOTAL ORGANIC RESIDUES 10 PERCENT OR MORE AMOUNT DISPOSED(TONS): 1.2093 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2009 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 1.8974 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2009 TSD ID: CAT080012602 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SOLANO WASTE CATEGORY: AQUEOUS SOLUTION WITH TOTAL ORGANIC RESIDUES 10 PERCENT OR MORE AMOUNT DISPOSED(TONS): 0.8340 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2008 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: AQUEOUS SOLUTION WITH TOTAL ORGANIC RESIDUES 10 PERCENT OR MORE AMOUNT DISPOSED(TONS): 0.3336 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) 31 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS) YEAR: 2008 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.7298 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) Back to Report Summary 32 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS) MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) SITE INFORMATION CONTACT INFORMATION EPA ID: CAC000085381 CONTACT: PAT FULLER NAME: 1X JIFFY LUBE CORP.PHONE: (408) 265-2629 COUNTY: UNKNOWN ADDRESS: 23161 MILL CREEK ADDRESS: 1387 CAMDEN AVE. LAGUNA HILLS CA 92653 CAMPBELL, CA 95008 MANIFEST SUMMARY INFORMATION YEAR: 2006 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.1600 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) Back to Report Summary 33 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS) MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) SITE INFORMATION CONTACT INFORMATION EPA ID: CAD982326894 CONTACT: FRANK PEREZ, HSSE COORDINATOR NAME: JIFFY LUBE #297 PHONE: (713)546-6604 COUNTY: UNKNOWN ADDRESS: PO BOX 4427 ADDRESS: 1387 CAMDEN AVE HOUSTON TX 77210-4427 CAMPBELL, CA 95008 MANIFEST SUMMARY INFORMATION YEAR: 2008 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: AQUEOUS SOLUTION WITH TOTAL ORGANIC RESIDUES 10 PERCENT OR MORE AMOUNT DISPOSED(TONS): 1.4387 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2008 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.4879 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2007 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.2200 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2007 TSD ID: CAD097030993 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: OTHER ORGANIC SOLIDS AMOUNT DISPOSED(TONS): 0.0500 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2007 TSD ID: CAL000161743 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SANTA CLARA 34 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS) WASTE CATEGORY: AQUEOUS SOLUTION WITH TOTAL ORGANIC RESIDUES 10 PERCENT OR MORE AMOUNT DISPOSED(TONS): 0.3500 DISPOSAL METHOD: OTHER RECOVERY OF RECLAMATION FOR REUSE INCLUDING ACID REGENERATION, ORGANICS RECOVERY ECT YEAR: 2007 TSD ID: CAL000161743 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SANTA CLARA WASTE CATEGORY: AQUEOUS SOLUTION WITH TOTAL ORGANIC RESIDUES 10 PERCENT OR MORE AMOUNT DISPOSED(TONS): 0.7900 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2006 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.1400 DISPOSAL METHOD: METALS RECOVERY INCLUDING RETORING,SMELTING,CHEMICALS,ECT YEAR: 2006 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.1400 DISPOSAL METHOD: TRANSFER STATION YEAR: 2006 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.0400 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2006 TSD ID: CAD044003556 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: YOLO WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.1200 DISPOSAL METHOD: STORAGE, BULKING, AND/OR TRANSFER OFF SITE--NO TREATMENT/REOVERY (H010-H129) OR (H131- H135) YEAR: 2006 TSD ID: CAD097030993 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES 35 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS) WASTE CATEGORY: OTHER ORGANIC SOLIDS AMOUNT DISPOSED(TONS): 0.1000 DISPOSAL METHOD: METALS RECOVERY INCLUDING RETORING,SMELTING,CHEMICALS,ECT YEAR: 2006 TSD ID: CAD097030993 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: OTHER ORGANIC SOLIDS AMOUNT DISPOSED(TONS): 0.1000 DISPOSAL METHOD: TRANSFER STATION YEAR: 2006 TSD ID: CAT080013352 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.1400 DISPOSAL METHOD: RECYCLE YEAR: 2006 TSD ID: CAT080013352 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.1400 DISPOSAL METHOD: RECYCLER YEAR: 2006 TSD ID: CAT080013352 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.2200 DISPOSAL METHOD: RECYCLE YEAR: 2006 TSD ID: CAT080013352 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.2200 DISPOSAL METHOD: RECYCLER YEAR: 2006 TSD ID: CAT080013352 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.4100 DISPOSAL METHOD: RECYCLE YEAR: 2006 36 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS) TSD ID: CAT080013352 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: LOS ANGELES WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.4100 DISPOSAL METHOD: RECYCLER YEAR: 2005 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 3.0400 DISPOSAL METHOD: RECYCLER YEAR: 2005 TSD ID: CAD044003566 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: UNKNOWN WASTE CATEGORY: UNSPECIFIED OIL-CONTAINING WASTE AMOUNT DISPOSED(TONS): 0.2200 DISPOSAL METHOD: BLANK YEAR: 2005 TSD ID: CAD982444481 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN BERNARDINO WASTE CATEGORY: OTHER ORGANIC SOLIDS AMOUNT DISPOSED(TONS): 0.0400 DISPOSAL METHOD: RECYCLER YEAR: 2004 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 1.5400 DISPOSAL METHOD: RECYCLER YEAR: 2004 TSD ID: CAD982444481 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN BERNARDINO WASTE CATEGORY: OTHER ORGANIC SOLIDS AMOUNT DISPOSED(TONS): 0.0200 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE 37 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS) AMOUNT DISPOSED(TONS): 0.1200 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.1400 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.2000 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.2900 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.3300 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.3700 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.4100 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 38 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS) GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.4500 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.5400 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.5800 DISPOSAL METHOD: RECYCLER YEAR: 2002 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.6200 DISPOSAL METHOD: RECYCLER YEAR: 2001 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 0.9500 DISPOSAL METHOD: BLANK YEAR: 2001 TSD ID: CAD009452657 GENERATOR COUNTY: SANTA CLARA DISPOSAL COUNTY: SAN MATEO WASTE CATEGORY: UNSPECIFIED ORGANIC LIQUID MIXTURE AMOUNT DISPOSED(TONS): 8.6700 DISPOSAL METHOD: RECYCLER Back to Report Summary 39 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS) MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) SITE INFORMATION ID#: T0608500295 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02E02F SITE NAME: JIFFY LUBE RESPONSIBLE PARTY: DANIEL MCQUILLEN ADDRESS: 1387 CAMDEN ADDRESS: P.O. BOX 2967 CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: OTHER GROUNDWATER (NOT USED FOR DRINKING WATER) CASE WAS REPORTED: 1988-05-20 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: NOT REPORTED ENFORCEMENT TYPE: INFORMAL STAFF ENFORCEMENT LETTER ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 5C - POLLUTION CHARACTERIZATION LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA HLTH DEPT - TOXICS MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: 1965-01-01 HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: 9999-09-09 CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: 0 SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1993-06-15 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: 1993-06-15 REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 40 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 41 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST) MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) SITE INFORMATION ID#: T0608500775 REGIONAL CASE #: 43-0749 LOCAL CASE #: 08S1W02E00 SITE NAME: JIFFY LUBE RESPONSIBLE PARTY: NOT REPORTED ADDRESS: 1387 CAMDEN AVE ADDRESS: NOT REPORTED CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: OTHER GROUNDWATER (NOT USED FOR DRINKING WATER) CASE WAS REPORTED: 05/20/88 CASE ENTERED INTO SYSTEM: 07/18/88 CASE WAS REVIEWED: 02/01/01 CASE WAS CLOSED: NOT REPORTED ENFORCEMENT TYPE: NOT REPORTED ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: NOT REPORTED PROGRAM FOR THE CASE: NOT REPORTED INTERIM FOR THE CASE: N = NO INTER CURRENT STATUS: 8 - VERIFICATION MONITORING UNDERWAY LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: NOT REPORTED MTBE CLASSIFICATION: C - THIRD HIGHEST PRIORITY MAXIMUM MTBE CONCENTRATION WAS FOUND: 01/02/65 MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: 890 MAXIMUM SOIL CONCENTRATION OF MTBE: 1 NUMBER OF MTBE ANALYTICAL RESULTS: 2 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: NOT REPORTED CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: TANK CLOSURE DATE LEAK WAS DISCOVERED: 05/20/88 HOW THE CASE/LEAK WAS STOPPED: CLOSE TANK LEAK WAS STOPPED: 05/20/88 CAUSE OF LEAK: STRUCTURAL FAILURE SOURCE OF LEAK: TANK LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: 01/02/65 CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: (NT) * CODE NOT DEFINED BY REPORTING AGENCY 42 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 5898.15305248209 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: NOT REPORTED Back to Report Summary 43 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) FACILITY INFORMATION FACILITY #: 67261 STATUS: INACTIVE BOE: 44-000741 JURISDICTION: CITY OF CAMPBELL NAME: JIFFY LUBE AGENCY: FIRE DEPARTMENT ADDRESS: 1387 CAMDEN AVE CAMPBELL, CA 95008 TANK INFORMATION TANK #: 000001 CAPACITY: 10000 INSTALLED: 01-01-76 REMOVED: 04-29-88 TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: FIBERGLASS TANK #: 000002 CAPACITY: 8000 INSTALLED: 01-01-71 REMOVED: 04-29-88 TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: LEADED CONTAINMENT: BARE STEEL TANK #: 000003 CAPACITY: 8000 INSTALLED: 01-01-71 REMOVED: 04-29-88 TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: BARE STEEL TANK #: 000004 CAPACITY: 110 INSTALLED: 01-01-83 REMOVED: 04-29-88 TANK USE: OIL STORAGE TYPE: WASTE CONTENT: WASTE OIL CONTAINMENT: BARE STEEL Back to Report Summary 44 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) FACILITY INFORMATION REGISTRY ID: 110017963097 NAME: JIFFY LUBE #0297 LOCATION ADDRESS: 1387 CAMDEN AVE CAMPBELL, CA 95008 COUNTY: SANTA CLARA EPA REGION: 09 FEDERAL FACILITY: NOT REPORTED TRIBAL LAND: NOT REPORTED ALTERNATIVE NAME/S: JIFFY LUBE #0297 JIFFY LUBE JIFFY LUBE #0297 JIFFY LUBE #0297 PROGRAM/S LISTED FOR THIS FACILITY UORS - CALIFORNIA USED OIL RECYCLING SYSTEM CA-CERS - *DEFINITION NOT PROVIDED BY REPORTING AGENCY CA-ENVIROVIEW - *DEFINITION NOT PROVIDED BY REPORTING AGENCY CA-ENVIROVIEW - *DEFINITION NOT PROVIDED BY REPORTING AGENCY STANDARD INDUSTRIAL CLASSIFICATION/S (SIC) 5511 - MOTOR VEHICLE DEALERS (NEW AND USED) NORTH AMERICAN INDUSTRY CLASSIFICATION/S (NAICS) NO NAICS DATA REPORTED Back to Report Summary 45 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA) MAP ID# 1 Distance from Property: 0.018 mi. (95 ft.) E Elevation: 233 ft. (Lower than TP) SITE INFORMATION ID #: 985047222 NAME: JIFFY LUBE #297 ADDRESS: 1387 CAMDEN AVE. CITY: CAMPBELL STATE: CA TOTAL GALLONS: 6160 OWNER INFORMATION NAME: JIFFY LUBE INTERNATIONAL, INC. Back to Report Summary 46 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST) MAP ID# 2 Distance from Property: 0.06 mi. (317 ft.) NE Elevation: 232 ft. (Lower than TP) FACILITY INFORMATION ID#: 43-0156 NAME: BEACON ADDRESS: 1370 CAMDEN SAN JOSE, CA 95008 Back to Report Summary 47 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE) MAP ID# 2 Distance from Property: 0.06 mi. (317 ft.) NE Elevation: 232 ft. (Lower than TP) SITE INFORMATION ID#: T0608500222 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02E01F SITE NAME: BEACON RESPONSIBLE PARTY: ROBERT FISHBURN ADDRESS: 1370 CAMDEN ADDRESS: 905 RANCHO CONEJO BLVD. CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: DRINKING WATER AQUIFER CASE WAS REPORTED: 1985-12-20 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: NOT REPORTED ENFORCEMENT TYPE: INFORMAL STAFF ENFORCEMENT LETTER ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 7 - REMEDIAL ACTION UNDERWAY LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA HLTH DEPT - TOXICS MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: 1965-01-01 HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: 9999-09-09 CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: 0 SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1988-01-15 REMEDIAL ACTION UNDERWAY: 2003-01-31 POLUTION CHARACTERIZATION: 1988-05-19 REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 48 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 49 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 2 Distance from Property: 0.06 mi. (317 ft.) NE Elevation: 232 ft. (Lower than TP) FACILITY INFORMATION FACILITY #: 934 STATUS: ACTIVE BOE: 44-024660 JURISDICTION: SANTA CLARA COUNTY NAME: BEACON STATION #420 AGENCY: PUBLIC HEALTH, HAZARDOUS MTLS. ADDRESS: 1370 CAMDEN CAMPBELL, CA 95008 TANK INFORMATION TANK #: 000001 CAPACITY: 12000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: NOT REPORTED TANK #: 000002 CAPACITY: 12000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: NOT REPORTED TANK #: 000003 CAPACITY: 12000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: PRM UNLEADED CONTAINMENT: NOT REPORTED Back to Report Summary 50 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 2 Distance from Property: 0.06 mi. (317 ft.) NE Elevation: 232 ft. (Lower than TP) FACILITY INFORMATION GEOSEARCH ID: 333215838 FACILITY ID: 43-000-200083 NAME: BEACON (CAMPBELL) ADDRESS: 1370 CAMDEN AV. CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS OTHER FACILITY NAME(S) LISTED FOR THIS SITE: BEACON (CAMPBELL) PERMIT AGENCY: CAMPBELL,CUPERTINO,LOS GATOS,MORGAN HILL Back to Report Summary 51 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA) MAP ID# 2 Distance from Property: 0.06 mi. (317 ft.) NE Elevation: 232 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: CAR000142364 OWNER TYPE: PRIVATE NAME: TESORO WEST COAST CO LLC 68117 OWNER NAME: TESORO WEST COAST COMPANY LLC ADDRESS: 1370 CAMDEN AVE OPERATOR TYPE: PRIVATE CAMPBELL, CA 95008 OPERATOR NAME: TESORO WEST COAST CO LLC CONTACT NAME: ROB DONOVAN CONTACT ADDRESS: 3450 S 344TH WAY STE 201 AUBURN WA 98001 CONTACT PHONE: 253-896-8716 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 05/09/2007 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: ROB DONOVAN CORP ENV AFFAIRS MGR 05/08/2007 CHUCK MILLER COMPLIANCE MGR 02/28/2003 INDUSTRY CLASSIFICATION (NAICS) 44711 - GASOLINE STATIONS WITH CONVENIENCE STORES SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 05/09/2007 NAME: TESORO WEST COAST CO LLC 68117 GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR DATE RECEIVED BY AGENCY: 03/13/2003 NAME: USA GASOLINE CORPORATION FACILITY 3420 GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: SMALL QUANTITY GENERATOR LAST UPDATED DATE: 08/15/2007 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS - NO EVALUATIONS REPORTED - VIOLATIONS - NO VIOLATIONS REPORTED - 52 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE D018 BENZENE UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 53 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) MAP ID# 2 Distance from Property: 0.06 mi. (317 ft.) NE Elevation: 232 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608500222 BUSINESS NAME: BEACON - 1370 CAMDEN ADDRESS: 1370 CAMDEN AVENUE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: 02-015 STATUS: COMPLETED - CASE CLOSED 11/06/2015 POTENTIAL CONTAMINATION: BENZENE, TOLUENE, XYLENE, MTBE / TBA / OTHER FUEL OXYGENATES, GASOLINE POTENTIAL MEDIA AFFECTED: AQUIFER USED FOR DRINKING WATER SUPPLY, SOIL SITE HISTORY: 1985 THE THREE FORMER USTS WERE EXCAVATED AND REMOVED FROM THE SITE. FOUR HOLES WERE OBSERVED IN THE BOTTOM OF THE MIDDLE TANK (TANK T-2) AFTER ITS REMOVAL FROM THE UST CAVITY. A SPILL/LEAK REPORT WAS FILED WITH THE REGIONAL WATER QUALITY CONTROL BOARD AND A FUEL LEAK CASE WAS OPENED. OVER- EXCAVATION OF GASOLINE-IMPACTED SOILS BENEATH THE FORMER LOCATION OF TANK T-2 WAS PERFORMED TO A DEPTH OF APPROXIMATELY 22 FEET BELOW SURFACE GRADE (BSG). ANALYTICAL RESULTS OF SOIL SAMPLE S-15-T2N COLLECTED FROM BENEATH TANK T-2 AT A DEPTH OF 15 FEET BSG INDICATED 120,000 PARTS PER MILLION (PPM) OF TOTAL HYDROCARBONS, AND ANALYTICAL RESULTS OF SOIL SAMPLE S-22-T2S COLLECTED FROM BENEATH TANK T-2 AT A DEPTH OF 22 FEET BSG INDICATED 1,040 PPM OF TOTAL HYDROCARBONS. ANALYTICAL RESULTS OF SOIL SAMPLES COLLECTED FROM BENEATH TANKS T-1 AND T-3 AT DEPTHS OF 11 TO 15 FEET BSG INDICATED BETWEEN 29 PPM AND 2,100 PPM OF TOTAL HYDROCARBONS. THE EXCAVATED GASOLINE-IMPACTED SOILS WERE TRANSPORTED FROM THE SITE IN JANUARY 1986 FOR DISPOSAL AT THE CLASS I LANDFILL OPERATED BY CHEMICAL WASTE MANAGEMENT IN KETTLEMAN CITY, KINGS COUNTY, CALIFORNIA. APPROXIMATELY 200 CUBIC YARDS OF GASOLINE-IMPACTED SOILS WERE REMOVED FROM THE SITE. 1986 TWO BORINGS (B1-1 AND B1-2) WERE DRILLED TO DEPTHS OF APPROXIMATELY 60 FEET BSG AND 100 FEET BSG ON THE NORTHEAST SIDE OF THE USTS. GROUNDWATER WAS NOT ENCOUNTERED IN EITHER BORING DURING DRILLING. AFTER THE COLLECTION OF SOIL SAMPLES HAD BEEN COMPLETED, THE BORINGS WERE BACKFILLED WITH CEMENT GROUT. RESULTS OF THE LABORATORY ANALYSES OF SELECTED SOIL SAMPLES INDICATED THAT GASOLINE-IMPACTED SOILS WERE PRESENT TO APPROXIMATELY 95 FEET BSG, WITH THE HIGHEST CONCENTRATIONS PRESENT AT APPROXIMATELY 60 FEET BSG. 1988 BORING B-2 WAS DRILLED TO A DEPTH OF APPROXIMATELY 95 FEET BSG ON THE SOUTHEAST SIDE OF THE USTS. GROUNDWATER WAS NOT ENCOUNTERED IN THE BORING DURING DRILLING. AFTER THE COLLECTION OF SOIL SAMPLES HAD BEEN COMPLETED, TWO VADOSE-ZONE MONITORING WELLS (VW-1A AND VW-1B) WERE CONSTRUCTED IN BORING B-2. WELL VW-1A WAS SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 75 TO 95 FEET BSG, AND WELL VW-1B WAS SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 52 TO 62 FEET BSG. RESULTS OF THE LABORATORY ANALYSES OF SELECTED SOIL SAMPLES INDICATED THAT GASOLINE-IMPACTED SOILS WERE PRESENT PRIMARILY AT DEPTHS OF APPROXIMATELY 55 TO 60 FEET BSG, 70 TO 75 FEET BSG, AND 85 TO 90 FEET BSG. BORING B-4 WAS DRILLED TO A DEPTH OF APPROXIMATELY 127¢ FEET BSG ON THE SOUTHEAST SIDE OF THE USTS. GROUNDWATER WAS ENCOUNTERED AT A DEPTH OF APPROXIMATELY 120 FEET BSG DURING DRILLING. AFTER THE COLLECTION OF SOIL SAMPLES HAD BEEN COMPLETED, GROUNDWATER MONITORING WELL MW-1 WAS CONSTRUCTED IN BORING B-4, AND WAS SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 100 TO 125 FEET BSG. RESULTS OF THE LABORATORY 54 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES) ANALYSES OF SELECTED SOIL SAMPLES INDICATED THAT NO CONCENTRATIONS OF GASOLINE-IMPACTED SOILS WERE PRESENT BELOW DEPTHS OF 100 FEET BSG. RESULTS OF THE LABORATORY ANALYSES OF A GROUNDWATER SAMPLE COLLECTED FROM WELL MW-1 INDICATED CONCENTRATIONS OF DISSOLVED TPHG AND BTEX WERE PRESENT IN THE GROUNDWATER. 1989 GROUNDWATER MONITORING OF WELLS VW-1A, VW-1B AND MW-1 WAS INITIATED IN OCTOBER 1988. DEPTHS TO GROUNDWATER WERE RECORDED IN WELL VW-1B BETWEEN 50 TO 62 FEET BSG, IN WELL MW-1 BETWEEN 99 TO 110 FEET BSG, AND WELL VW-1A WAS DRY. LIQUID-PHASE HYDROCARBONS (LPH) WERE REPORTED IN WELL VW-1B, AND WERE REMOVED BY HAND-BAILING. RESULTS OF THE LABORATORY ANALYSES OF GROUNDWATER SAMPLES COLLECTED FROM WELL MW-1 INDICATED CONCENTRATIONS OF DISSOLVED TPHG AND BTEX WERE PRESENT IN THE GROUNDWATER. NO LPH HAS BEEN OBSERVED SINCE AUGUST 1990. 1990 BORING B-5 WAS DRILLED TO A DEPTH OF APPROXIMATELY 66 FEET BSG ON THE SOUTHWEST SIDE OF THE USTS, AND BORING B-6 WAS DRILLED TO A DEPTH OF APPROXIMATELY 75 FEET BSG ON THE NORTHEAST SIDE OF THE USTS. GROUNDWATER WAS NOT ENCOUNTERED IN EITHER BORING DURING DRILLING. AFTER THE COLLECTION OF SOIL SAMPLES HAD BEEN COMPLETED, VADOSE-ZONE MONITORING WELLS VW-2 AND VW-3 WERE CONSTRUCTED IN THE BORINGS. WELL VW-2 WAS SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 48 TO 58 FEET BSG, AND WELL VW-3 WAS SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 47 TO 62 FEET BSG. RESULTS OF THE LABORATORY ANALYSES OF SELECTED SOIL SAMPLES INDICATED THAT GASOLINE-IMPACTED SOILS WERE PRESENT PRIMARILY AT DEPTHS OF APPROXIMATELY 50 TO 60 FEET BSG. MAY AND JUNE 1990 EVAX TECHNOLOGIES INC. (EVAX) CONDUCTED A VAPOR EXTRACTION PERFORMANCE TEST AND LIMITED SOIL GAS SURVEY OF WELLS VW-1A, VW-1B, VW-2 AND VW-3. RESULTS OF THE VAPOR TESTING INDICATED THAT THE HIGHEST VAPOR CONCENTRATIONS WERE BENEATH THE EASTERN SIDE OF THE USTS, A RADIUS OF VAPOR CAPTURE OF APPROXIMATELY 50 FEET, AND THE SUBSURFACE SOILS WERE AMENABLE TO THE USE OF SOIL VAPOR EXTRACTION FOR SUBSURFACE SOIL REMEDIATION. A SOIL VAPOR EXTRACTION SYSTEM (SVES) WAS DESIGNED AND CONSTRUCTED IN SEPTEMBER 1990 AND CONSISTED OF FOUR VAPOR EXTRACTION WELLS (VW-1A, VW-1B, VW-2 AND VW-3), A MOISTURE KNOCK-OUT VESSEL, 100 CUBIC FEET PER MINUTE (CFM) VACUUM BLOWER/MOTOR, AND A COMBUSTION ENGINE EQUIPPED WITH A CATALYTIC CONVERTER AND SUPPLEMENTED WITH PROPANE, WITHIN THE REMEDIATION COMPOUND LOCATED ON THE NORTH SIDE OF THE STATION BUILDING. OPERATION OF THE SVES COMMENCED IN MID OCTOBER 1990 UNDER A PERMIT TO OPERATE (PTO) ISSUED BY THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT (BAAQMD). IN MARCH 1991, THE INTERNAL COMBUSTION ENGINE (ICE) WAS REMOVED BECAUSE OF DECLINING INFLUENT CONCENTRATIONS, AND REPLACED WITH A LONG-TERM AMBIENT VENTING (LTAV) UNIT, THAT CONSISTED OF THE 100 CFM VACUUM BLOWER/MOTOR, AND A SQUIRREL CAGE EXHAUST FAN MOTOR. APPROXIMATELY 7,460 POUNDS OF TPHG AND 129 POUNDS OF BENZENE WERE REMOVED FROM THE SUBSURFACE BY THE SVES BETWEEN OCTOBER 1990 AND DECEMBER 1994. THE SVES WAS SHUT OFF IN DECEMBER 1994 DUE TO DECLINING INFLUENT CONCENTRATIONS AND EQUIPMENT PROBLEMS. 1992 TWO BORINGS (MW2 AND MW3) WERE DRILLED TO A DEPTH OF APPROXIMATELY 111 FEET BSG, AND THREE BORINGS (VW4, VW5 AND VW6) TO WERE DRILLED TO DEPTHS OF APPROXIMATELY 60 TO 85 FEET BSG. AFTER THE COLLECTION OF SOIL SAMPLES HAD BEEN COMPLETED, GROUNDWATER MONITORING WELLS MW-2 AND MW-3 WERE CONSTRUCTED IN THE TWO DEEP BORINGS, AND WERE SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 96 TO 111 FEET BSG. GROUNDWATER WAS ENCOUNTERED AT DEPTHS OF APPROXIMATELY 100 AND 102 FEET BSG DURING DRILLING OF THE TWO DEEPER BORINGS. AFTER THE COLLECTION OF SOIL SAMPLES HAD BEEN COMPLETED, BORING VW4 WAS GROUTED UP, WELL VW-5 WAS SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 40 TO 55 FEET BSG, AND WELL VW-6 WAS SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 45 TO 60 FEET BSG. RESULTS OF THE LABORATORY ANALYSES OF SELECTED SOIL SAMPLES INDICATED THAT GASOLINE-IMPACTED SOILS WERE PRESENT PRIMARILY AT DEPTHS OF APPROXIMATELY 45 TO 55 FEET BSG. THE GROUNDWATER FLOW DIRECTION OF THE LOWER AQUIFER ZONE MONITORED BY WELLS MW-1, MW-2 AND MW-3 WAS TOWARDS THE EAST-SOUTHEAST BENEATH THE SITE. RESULTS OF THE LABORATORY ANALYSES OF GROUNDWATER SAMPLES COLLECTED FROM WELLS MW-1, MW-2 AND MW-3 INDICATED NO CONCENTRATIONS OF DISSOLVED TPHG, BTEX, AND MTBE WERE PRESENT. MAY 1995 EIGHT BORINGS (SB-1 THROUGH SB-4 AND CB-1 THROUGH CB-4) WERE DRILLED TO DEPTHS OF APPROXIMATELY 70 TO 90 FEET BSG, THE INSTALLATION OF FIVE VAPOR EXTRACTION WELLS (SB-4 AND CB-1 THROUGH CB-4) IN SELECTED BORINGS, AND THE 55 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES) DESTRUCTION OF VAPOR WELLS VW-1A AND VW-1B BY OVER-DRILLING. AFTER THE COLLECTION OF SOIL SAMPLES HAD BEEN COMPLETED, VAPOR WELL SB-4 WAS SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 70 TO 85 FEET BSG, AND WELLS CB-1 THROUGH CB-4 WERE SCREENED AT VARIOUS DEPTHS BETWEEN 40 AND 75 FEET BSG. RESULTS OF THE LABORATORY ANALYSES OF SELECTED SOIL SAMPLES INDICATED THAT GASOLINE-IMPACTED SOILS WERE AGAIN PRESENT PRIMARILY AT DEPTHS OF APPROXIMATELY 45 TO 60 FEET BSG AND 65 TO 80 FEET BSG. 1997 THE DESTRUCTION OF THE THREE LOWER AQUIFER GROUNDWATER MONITORING WELLS MW-1, MW-2 AND MW-3 BY OVER- DRILLING WITH HOLLOW-STEM AUGERS WAS COMPLETED. THE OVER-DRILLING PROCEDURES REMOVED THE GROUT, WELL SEALS AND FILTER SANDS, AND A BENTONITE/NEAT CEMENT GROUT SLURRY WAS PLACED IN EACH OF THE BORINGS UP TO THE SURROUNDING SURFACE GRADE. THE GROUNDWATER FLOW DIRECTION OF THE LOWER AQUIFER BETWEEN 1992 AND 1997 HAD GENERALLY BEEN TOWARDS THE EAST-NORTHEAST. 1998 HORIZON ENVIRONMENTAL INC. (HORIZON) OBSERVED THE DRILLING OF THREE BORINGS TO DEPTHS OF APPROXIMATELY 65 TO 70 FEET BSG ON THE NORTHEAST SIDE OF THE USTS. GROUNDWATER WAS NOT ENCOUNTERED IN THE BORINGS DURING DRILLING. AFTER THE COLLECTION OF SOIL SAMPLES HAD BEEN COMPLETED, MONITORING WELLS MW-4 AND MW-5 WERE SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 40 TO 60 FEET BSG, AND SPARGE WELL SW-1 WAS SCREENED BETWEEN THE DEPTHS OF APPROXIMATELY 62 TO 67 FEET BSG. IN APRIL 1999, SPARGE WELL SW-1 WAS DEEPENED TO A DEPTH OF APPROXIMATELY 71 FEET BSG, AND ATTEMPTS WERE MADE TO DEEPEN WELLS MW-4 AND MW-5. NO GROUNDWATER WAS ENCOUNTERED DURING THE DEEPENING OF WELLS MW-4 AND MW-5 TO A DEPTH OF APPROXIMATELY 85 FEET, SO THE BORINGS FOR THESE TWO WELLS WERE BACKFILLED WITH A BENTONITE/NEAT CEMENT GROUT SLURRY. ALSO, IN OCTOBER 1998, GROUNDWATER MONITORING WELLS CB-1, CB-4 AND SB-4 WERE DESTROYED. EACH OF THESE WELLS WAS OVER-DRILLED WITH HOLLOW-STEM AUGERS. THE OVER-DRILLING PROCEDURES REMOVED THE GROUT, WELL SEALS AND FILTER SANDS. A BENTONITE / NEAT CEMENT GROUT SLURRY WAS PLACED IN EACH OF THE BORINGS, THE STEEL TRAFFIC BOXES AND SURROUNDING CONCRETE APRONS WERE REMOVED, AND CONCRETE WAS PLACED UP TO THE SURROUNDING SURFACE GRADE. 1999 HORIZON PERFORMED A LOCAL WELL SEARCH TO IDENTIFY POTENTIAL PREFERENTIAL MIGRATION PATHWAYS THAT COULD ACT AS VERTICAL CONDUITS IN THE VICINITY OF THE SITE. A LOCAL WELL SEARCH WAS CONDUCTED BY ACQUIRING AND REVIEWING A LISTING FROM THE SANTA CLARA VALLEY WATER DISTRICT (SCVWD) OF KNOWN WELLS WITHIN A ¢-MILE RADIUS OF THE SITE. INFORMATION PROVIDED BY THE SCVWD INDICATED THAT WITHIN A ¢-MILE RADIUS OF THE SITE, THERE ARE APPROXIMATELY 11 GROUNDWATER MONITORING WELLS, FOUR VAPOR MONITORING WELLS, NINE DESTROYED MONITORING WELLS AND TWO DESTROYED OTHER WELLS, AND ONE CATHODIC WELL. NO DOMESTIC OR MUNICIPAL SUPPLY WELLS WERE IDENTIFIED WITHIN THE ¢-MILE RADIUS OF THE SITE. 2000 HORIZON CONDUCTED A SUBSURFACE SOIL AND GROUNDWATER INVESTIGATION AT THE SITE. THE PURPOSE OF THE INVESTIGATION WAS TO ASSESS THE LATERAL AND VERTICAL EXTENT OF METHYL TERT-BUTYL ETHER (MTBE) AND OTHER DISSOLVED GASOLINE HYDROCARBONS BENEATH THE SITE AND ADJACENT OFFSITE AREAS BY ADVANCING SIX ONSITE BORINGS (MW-6, HB-1, HB-2, VW-7, VW-8 AND VW-9) AND FOUR OFFSITE BORINGS (HB-3, HB-4, HB-5 AND HB-6) TO MAXIMUM DEPTHS OF BETWEEN APPROXIMATELY 85 TO 90 FEET BSG. THE VERTICAL EXTENT OF GASOLINE-IMPACTED SOIL APPEARS TO EXTEND TO MAXIMUM DEPTHS OF 70 TO 75 FEET BSG PRIMARILY IN THE AREA OF BORINGS SW-1, HB-1 AND HB-2. THESE THREE BORINGS ARE LOCATED ON THE WEST AND EAST SIDES OF THE EXISTING USTS. THE VERTICAL EXTENT OF MTBE- IMPACTED SOIL HAS BEEN DEFINED TO NONDETECTABLE CONCENTRATIONS (LESS THAN 0.0050 PPM) IN ONSITE BORINGS MW-5, HB-2, HB-4 AND HB-6. MTBE-IMPACTED PERCHED GROUNDWATER BETWEEN APPROXIMATELY 38 AND 43 FEET BSG (PERCHED WATER ZONE A) WAS MIGRATING TO THE NORTH, WEST AND EAST FROM THE AREA OF THE USTS, AND MTBE- IMPACTED PERCHED GROUNDWATER BETWEEN APPROXIMATELY 57 AND 67 FEET BSG (PERCHED WATER ZONE B) WAS MIGRATING TO THE NORTH AND WEST FROM THE AREA OF THE USTS. HORIZON ALSO PERFORMED A CONDUIT STUDY TO IDENTIFY POTENTIAL PREFERENTIAL MIGRATION PATHWAYS THAT MAY BE PRESENT IN THE VICINITY OF THE SITE. HORIZON INVESTIGATED THE LOCATIONS AND DEPTHS OF UTILITY TRENCHES PRESENT WITHIN CAMDEN AVENUE AND ERIN WAY, INCLUDING STORM DRAINS AND SANITARY SEWERS, THAT COULD ACT AS HORIZONTAL CONDUITS. HORIZON CONTACTED THE CITY OF CAMPBELL DEPARTMENT OF PUBLIC WORKS (CDPW) AND THE CITY OF SAN JOSE DEPARTMENT OF PUBLIC WORKS (SJDPW) FOR INFORMATION ON THE LOCATIONS AND DEPTHS OF STORM DRAINS AND SANITARY 56 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES) SEWERS WITHIN THE CAMDEN AVENUE AND ERIN WAY RIGHTS-OF-WAYS. INFORMATION OBTAINED FROM THE LOCAL PUBLIC WORKS AGENCIES INDICATED THE DEEPEST UTILITY TRENCHES IN CAMDEN AVENUE AND ERIN WAY ARE SANITARY SEWER PIPELINES OF APPROXIMATELY 14 FEET IN DEPTH. BECAUSE OF THE COARSE-GRAINED SANDS AND GRAVEL SOILS PRESENT BENEATH THE SITE AREA, THE PETROLEUM HYDROCARBONS LIKELY MIGRATED VERTICALLY AND WERE NOT AFFECTED BY THE RELATIVELY SHALLOW UTILITIES IN THE SITE AREA THAT COULD ACT AS POTENTIAL PREFERENTIAL MIGRATION PATHWAYS. HOWEVER, ARTIFICIAL GROUNDWATER RECHARGE IN THE AREA COULD BE SEASONALLY AFFECTING THE GROUNDWATER DEPTHS AND FLOW DIRECTIONS BENEATH THE SITE. 2001 HORIZON PERFORMED SOIL SAMPLING RELATED TO FUEL DISTRIBUTION PIPELINE AND DISPENSER UPGRADES. THE SOIL SAMPLE RESULTS INDICATED RELATIVELY LOW PETROLEUM HYDROCARBON IMPACTS TO THE SHALLOW SUBSURFACE SOILS BENEATH THE FORMER FUEL DISTRIBUTION PIPELINES AND DISPENSERS AT THE SITE. 2002 HORIZON INSTALLED MONITORING WELLS (MW-7, MW-8 AND MW-9) TO INVESTIGATE THE ôUPPERö PERCHED GROUNDWATER ZONE BETWEEN THE DEPTHS OF APPROXIMATELY 37 AND 47 FEET BSG (PERCHED WATER ZONE A); MONITORING WELLS (MW-10, MW-11, MW-12 AND MW-13) TO INVESTIGATE THE ôLOWERö PERCHED GROUNDWATER ZONE BETWEEN THE DEPTHS OF APPROXIMATELY 57 AND 67 FEET BSG (PERCHED WATER ZONE B); AND DRILLED AND SAMPLED SOIL AND GROUNDWATER AT DEPTHS UP TO APPROXIMATELY 100 FEET BSG IN BORINGS HB-7 AND HB-8. LOW CONCENTRATIONS OF TPHG (52 PARTS PER BILLION [PPB]), BENZENE (0.69 PPB), THE FUEL OXYGENATES MTBE (30 PPB), TBA (7.0 PPB), ETBE (0.51 PPB), AND ETHANOL (22 PPB) WERE REPORTED IN THE GROUNDWATER SAMPLE COLLECTED FROM DEEP BORING HB-7, WHILE NO CONCENTRATIONS OF TPHG, BTEX, THE FUEL OXYGENATES MTBE, DIPE, ETBE, TAME, TBA, ETHANOL AND METHANOL, AND THE LEAD SCAVENGER COMPOUNDS 1,2-DCA AND 1,2-DBA WERE REPORTED IN THE GROUNDWATER SAMPLE COLLECTED FROM DEEP BORING HB-8 IN THE EASTERN CORNER OF THE SITE. 2003 HORIZON SUBMITTED A CORRECTIVE ACTION PLAN TO THE SCVWD. HORIZON RECOMMENDED THAT AN OZONE-SPARGE SYSTEM SHOULD BE INSTALLED AT THE SITE TO EVALUATE THE EFFECTIVENESS OF OZONE-SPARGING AS A REMEDIAL ALTERNATIVE. HORIZON RECOMMENDED THAT APPROXIMATELY EIGHT OZONE-SPARGE WELLS SHOULD BE INSTALLED IN THE IMPACTED ôLOWERö PERCHED WATER ZONE BENEATH THE SITE. ADDITIONALLY, HORIZON RECOMMENDED THE INSTALLATION OF A SLANTED VAPOR EXTRACTION WELL (VW-10) ON THE EASTERN SIDE AND ANGLING BENEATH THE USTS, AND TIED INTO THE EXISTING SVES TO REMOVE HYDROCARBON VAPORS FROM THE IMPACTED SOIL BENEATH THE USTS. THE EXISTING SVES AT THE SITE COULD ALSO BE UTILIZED FOR THE CAPTURE OF OZONE GAS FROM THE SPARGING PROCESS. 2004 THE CORRECTIVE ACTION PLAN WAS IMPLEMENTED AND THE OZONE SPARGE SYSTEM (OZSS) OPERATED FROM DECEMBER 15, 2004 UNTIL FEBRUARY 10, 2010, AT WHICH TIME THE SYSTEM WAS CHANGED FROM OZONE TO OXYGEN-ONLY INJECTION. THE COMBINATION OF OZONE AND ITS REACTIVE INTERMEDIATES IN THE GROUNDWATER TREATMENT PROCESS DEGRADE TO PRODUCE SEVERAL HARMLESS ORGANIC COMPOUNDS, ALLOWING FOR THE IN-SITU OXIDATION OF ORGANIC COMPOUNDS, INCLUDING THE MORE RECALCITRANT ORGANICS, SUCH AS MTBE. APPROXIMATELY 1,014 POUNDS OF OZONE WERE SPARGED INTO THE SATURATED SUBSURFACE BY THE OZSS. THE 1,014 POUNDS OF OZONE PROVIDED THE POTENTIAL FOR APPROXIMATELY 290 POUNDS OF GASOLINE TO BE BIODEGRADED. REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK DISCOVERY OTHER 01/01/50 LEAK REPORTED REMEDIATION 01/01/50 EXCAVATION REMEDIATION 01/01/50 SOIL VAPOR EXTRACTION (SVE) ENFORCEMENT 11/06/2015 CLOSURE/NO FURTHER ACTION LETTER RESPONSE 10/15/2015 WELL DESTRUCTION REPORT RESPONSE 07/16/2015 WELL DESTRUCTION REPORT ENFORCEMENT 07/08/2015 STAFF LETTER RESPONSE 04/17/2015 WELL DESTRUCTION REPORT ENFORCEMENT 03/12/2015 STAFF LETTER 57 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES) TYPE OF ACTION:DATE:ACTION: ENFORCEMENT 01/05/2015 STAFF LETTER ENFORCEMENT 10/29/2014 NOTIFICATION - PUBLIC NOTICE OF CASE CLOSURE ENFORCEMENT 08/06/2013 STAFF LETTER RESPONSE 07/05/2013 OTHER REPORT / DOCUMENT ENFORCEMENT 05/24/2013 STAFF LETTER RESPONSE 03/22/2013 SITE ASSESSMENT REPORT ENFORCEMENT 11/20/2012 STAFF LETTER RESPONSE 09/21/2012 OTHER WORKPLAN - REGULATOR RESPONDED ENFORCEMENT 07/19/2012 STAFF LETTER RESPONSE 07/31/2010 MONITORING REPORT - QUARTERLY RESPONSE 04/30/2010 MONITORING REPORT - QUARTERLY RESPONSE 01/31/2010 MONITORING REPORT - QUARTERLY RESPONSE 10/31/2009 MONITORING REPORT - QUARTERLY ENFORCEMENT 06/15/2009 STAFF LETTER - #9002516 RESPONSE 10/31/2004 MONITORING REPORT - QUARTERLY RESPONSE 07/31/2004 MONITORING REPORT - QUARTERLY RESPONSE 04/30/2004 MONITORING REPORT - QUARTERLY RESPONSE 03/01/2004 OTHER REPORT / DOCUMENT RESPONSE 02/01/2004 OTHER REPORT / DOCUMENT RESPONSE 01/31/2004 MONITORING REPORT - QUARTERLY RESPONSE 01/01/2004 OTHER REPORT / DOCUMENT RESPONSE 12/01/2003 OTHER REPORT / DOCUMENT ENFORCEMENT 11/01/2003 STAFF LETTER - #42887 RESPONSE 11/01/2003 OTHER REPORT / DOCUMENT RESPONSE 10/31/2003 MONITORING REPORT - QUARTERLY ENFORCEMENT 10/17/2003 STAFF LETTER - #42711 RESPONSE 07/31/2003 MONITORING REPORT - QUARTERLY RESPONSE 04/30/2003 MONITORING REPORT - QUARTERLY ENFORCEMENT 02/01/2003 STAFF LETTER - #41288 RESPONSE 01/31/2003 MONITORING REPORT - QUARTERLY REMEDIATION 01/31/2003 SOIL VAPOR EXTRACTION (SVE) ENFORCEMENT 01/06/2003 WARNING LETTER - #40655 RESPONSE 10/31/2002 MONITORING REPORT - QUARTERLY RESPONSE 07/31/2002 MONITORING REPORT - QUARTERLY RESPONSE 04/30/2002 MONITORING REPORT - QUARTERLY ENFORCEMENT 03/19/2002 STAFF LETTER - #40652 ENFORCEMENT 03/05/2002 WARNING LETTER - #19890 ENFORCEMENT 01/01/2002 STAFF LETTER - #38288 RESPONSE 09/13/2001 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 08/24/2001 WARNING LETTER - #19889 ENFORCEMENT 07/30/2001 STAFF LETTER - #19879 RESPONSE 07/30/2001 MONITORING REPORT - QUARTERLY RESPONSE 06/21/2001 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 05/30/2001 STAFF LETTER - #19881 58 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES) TYPE OF ACTION:DATE:ACTION: ENFORCEMENT 05/07/2001 STAFF LETTER - #19877 RESPONSE 04/30/2001 MONITORING REPORT - QUARTERLY RESPONSE 04/13/2001 OTHER REPORT / DOCUMENT ENFORCEMENT 04/10/2001 STAFF LETTER - #19873 RESPONSE 01/31/2001 MONITORING REPORT - QUARTERLY RESPONSE 01/12/2001 SOIL AND WATER INVESTIGATION REPORT RESPONSE 10/31/2000 MONITORING REPORT - QUARTERLY ENFORCEMENT 10/14/2000 STAFF LETTER - #19865 RESPONSE 07/31/2000 MONITORING REPORT - QUARTERLY ENFORCEMENT 06/16/2000 STAFF LETTER - #19867 RESPONSE 02/28/2000 SOIL AND WATER INVESTIGATION REPORT ENFORCEMENT 11/30/1999 STAFF LETTER - #19863 RESPONSE 01/15/1998 MONITORING REPORT - QUARTERLY RESPONSE 10/15/1997 MONITORING REPORT - QUARTERLY RESPONSE 07/15/1997 MONITORING REPORT - QUARTERLY RESPONSE 04/15/1997 MONITORING REPORT - QUARTERLY RESPONSE 01/15/1997 MONITORING REPORT - QUARTERLY RESPONSE 10/15/1996 MONITORING REPORT - QUARTERLY RESPONSE 07/15/1996 MONITORING REPORT - QUARTERLY ENFORCEMENT 05/31/1996 STAFF LETTER - #19840 RESPONSE 01/15/1996 REMEDIAL PROGRESS REPORT ENFORCEMENT 12/01/1995 STAFF LETTER - #19834 RESPONSE 10/15/1995 MONITORING REPORT - QUARTERLY RESPONSE 07/15/1995 MONITORING REPORT - QUARTERLY ENFORCEMENT 05/31/1995 STAFF LETTER - #19829 ENFORCEMENT 06/08/1992 NOTICE OF VIOLATION - #39393 REMEDIATION 03/19/1991 SOIL VAPOR EXTRACTION (SVE) REMEDIATION 03/19/1991 EXCAVATION OTHER 12/18/1985 LEAK DISCOVERY OTHER 12/18/1985 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 11/06/2015 OPEN - ELIGIBLE FOR CLOSURE 08/06/2013 OPEN - ELIGIBLE FOR CLOSURE 01/31/2003 OPEN - REMEDIATION 01/31/2003 OPEN - SITE ASSESSMENT 05/19/1988 OPEN - SITE ASSESSMENT 01/15/1988 OPEN - CASE BEGIN DATE 12/20/1985 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 59 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES) CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: AARON COSTA CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089181954 EMAIL: AARON.COSTA@DEH.SCCGOV.ORG ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: NOT REPORTED CITY: OAKLAND CONTACT NAME: JOHN WOLFENDEN CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: JWOLFENDEN@WATERBOARDS.CA.GOV Back to Report Summary 60 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 3 Distance from Property: 0.065 mi. (343 ft.) E Elevation: 231 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608500344 BUSINESS NAME: CHEVRON #9-8354 ADDRESS: 1402 CAMDEN AVENUE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: 03-107 STATUS: OPEN - SITE ASSESSMENT 03/23/2007 POTENTIAL CONTAMINATION: DIESEL, MTBE / TBA / OTHER FUEL OXYGENATES, GASOLINE POTENTIAL MEDIA AFFECTED: OTHER GROUNDWATER (USES OTHER THAN DRINKING WATER), SOIL SITE HISTORY: THE SITE IS LOCATED ON THE NORTHEAST CORNER AT THE INTERSECTION OF ERIN WAY AND CAMDEN AVENUE IN AN UNINCORPORATED PART OF THE COUNTY OF SANTA CLARA (FIGURE 1). THE SITE IS BORDERED TO THE SOUTHWEST BY CAMDEN AVENUE, TO THE NORTHWEST BY ERIN WAY, TO THE SOUTHEAST BY COMMERCIAL PROPERTY, AND TO THE NORTHEAST BY A RESIDENCE/DAY CARE CENTER. A JIFFY LUBE« IS LOCATED SOUTHWEST ACROSS CAMDEN AVENUE. AN ACTIVE USA PETROLEUM-BRANDED SERVICE STATION IS LOCATED ADJACENT TO THE SITE ON THE NORTHWEST SIDE OF ERIN WAY (SECOR, 2007). THE SITE ELEVATION IS APPROXIMATELY 225 FEET ABOVE MEAN SEA LEVEL (MSL) AND IS LOCATED IN THE SANTA CLARA VALLEY GROUNDWATER BASIN. LOS GATOS CREEK IS LOCATED APPROXIMATELY 2,000 FEET WEST AND NORTHWEST OF THE SITE AND FLOWS NORTHEAST TOWARDS THE GUADALUPE RIVER. CURRENTLY, THE SITE HAS AN AREA OF APPROXIMATELY 0.5 ACRE AND IS CURRENTLY OCCUPIED BY THE CAMDEN RETAIL CENTER. THE BUILDING WAS COMPLETED IN SUMMER 2006 AND IS APPROXIMATELY 7,000 SQUARE FEET. IT HAS THREE SEPARATE SPACES FOR RETAIL/OFFICE USE. THE BUILDING CURRENTLY HOUSES A SUBWAY SANDWICH SHOP AND TWO UNOCCUPIED COMMERCIAL UNITS (SECOR, 2007). A FOOTPRINT OF THE BUILDING IS SHOWN ON FIGURE 2. WHEN THE SITE WAS IN USE AS A CHEVRON-BRANDED SERVICE STATION, SITE FEATURES INCLUDED A STATION BUILDING, TWO PRODUCT DISPENSER ISLANDS, ONE 1,000-GALLON DOUBLE-WALL FIBERGLASS FORMER USED OIL UNDERGROUND STORAGE TANK (UST), AND THREE GASOLINE USTS. THE GASOLINE USTS INCLUDED ONE 10,000-GALLON SINGLE-WALL FIBERGLASS TANK AND TWO 7,500-GALLON SINGLE-WALL STEEL TANKS (SECOR, 2007). A FOOTPRINT OF THE FORMER FUEL FEATURES IS SHOWN IN FIGURE 2. SERVICE STATION OPERATIONS CEASED IN MAY 1998. THE BUILDING WAS DEMOLISHED IN JUNE 1998, AND ALL USTS AND PRODUCT LINES WERE REMOVED IN JULY 1998. SUBSEQUENTLY, 16 SOIL SAMPLES WERE COLLECTED AT A MAXIMUM DEPTH OF 15 FEET BELOW GROUND SURFACE (BGS) FROM THE UST EXCAVATION AND FROM DEPTHS RANGING FROM 2 TO 3 FEET BGS FROM THE PRODUCT LINE EXCAVATIONS AND SUBMITTED FOR LABORATORY ANALYSIS. LABORATORY ANALYSIS OF THE SOIL SAMPLES IDENTIFIED PETROLEUM CONSTITUENTS BENEATH THE GASOLINE USTS, PRODUCT LINES, AND DISPENSER ISLANDS (SECOR, 2007). THE GASOLINE UST LOCATIONS WERE THEN OVER-EXCAVATED TO A DEPTH OF 20 FEET BGS WHILE THE AREA ENCOMPASSING THE PUMP ISLANDS AND PRODUCT LINES WAS OVER-EXCAVATED TO A DEPTH OF 5 TO 10 FEET BGS. TWELVE ADDITIONAL SOIL SAMPLES WERE COLLECTED AT A MAXIMUM DEPTH OF 20 FEET BGS FROM THE UST OVER- EXCAVATION AND FROM APPROXIMATELY 6.5 TO 10 FEET BGS FROM THE PRODUCT LINE OVEREXCAVATIONS. LABORATORY ANALYSIS OF THE SOIL SAMPLES COLLECTED DURING OVER-EXCAVATION CONFIRMED THE PRESENCE OF PETROLEUM CONSTITUENTS (TOUCHSTONE DEVELOPMENTS, 1998). TWO VADOSE-ZONE GROUNDWATER MONITORING WELLS WERE ALSO INSTALLED ON SITE TO A DEPTH OF APPROXIMATELY 16 FEET BGS. THE DATE THAT THESE WELLS 61 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES) WERE INSTALLED IS UNCLEAR. BETWEEN DECEMBER 14, 1998 AND JANUARY 12, 1999, TOUCHSTONE DEVELOPMENTS DRILLED THREE EXPLORATORY BOREHOLES (B-1 THROUGH B-3) AND THREE WELL BOREHOLES (MW-1 THROUGH MW-3). THE WELL BOREHOLES WERE ADVANCED TO DEPTHS BETWEEN 105 AND 110 FEET BGS. A TOTAL OF 89 SOIL SAMPLES FROM VARIOUS DEPTHS WERE SUBMITTED FOR CHEMICAL ANALYSIS. SAMPLES WERE ANALYZED FOR TOTAL PETROLEUM HYDROCARBONS AS GASOLINE RANGE ORGANICS (TPH-GRO), BENZENE, TOLUENE ETHYLBENZENE, AND TOTAL XYLENES (BTEX COMPOUNDS), AND GASOLINE OXYGENATES INCLUDING METHYLTERTIARY-BUTYL ETHER (MTBE) AND TERTIARY-BUTYL ALCOHOL (TBA). TPH-GRO WAS DETECTED IN 35 PERCENT OF THE SAMPLES, BTEX COMPOUNDS WERE DETECTED IN 25 PERCENT (BENZENE) AND 50 PERCENT (XYLENES) OF THE SAMPLES, AND MTBE WAS DETECTED IN 50 PERCENT OF THE SAMPLES. TBA WAS THE ONLY FUEL OXYGENATE DETECTED IN ADDITION TO MTBE IN 50 PERCENT OF THE SAMPLES. TOTAL OIL AND GREASE (TOG) WAS ALSO DETECTED IN ONE SAMPLE. TOUCHSTONE DEVELOPMENTS ALSO COLLECTED EIGHT GRAB GROUNDWATER SAMPLES FROM EACH OF THE SIX BOREHOLES. BETWEEN JANUARY 1999 AND JULY 2000, 21 ADDITIONAL GROUNDWATER SAMPLES WERE COLLECTED QUARTERLY (SEVEN ROUNDS) FROM WELLS MW-1, MW-2, AND MW-3. SAMPLES WERE CONSISTENTLY ANALYZED FOR PETROLEUM HYDROCARBONS. TPH-GRO WAS DETECTED IN 10 PERCENT OF THE SAMPLES, BTEX COMPOUNDS WERE DETECTED IN 10 PERCENT (BENZENE) AND 30 PERCENT (TOLUENE AND TOTAL XYLENES) OF THE SAMPLES AND MTBE WAS DETECTED IN 38 PERCENT OF THE SAMPLES. THE SANTA CLARA VALLEY WATER DISTRICT (SCVWD) REQUESTED AN ADDITIONAL SUBSURFACE INVESTIGATION TO FURTHER CHARACTERIZE THE EXTENT OF PETROLEUM HYDROCARBONS IN SOIL AND GROUNDWATER BENEATH THE SITE (SCVWD, NOVEMBER 16, 1998). MONITORING WELL MW-4 WAS INSTALLED TO PROVIDE THE ADDITIONAL MONITORING REQUESTED. SOIL AND GROUNDWATER SAMPLES WERE ANALYZED FOR PETROLEUM CONSTITUENTS. BENZENE WAS DETECTED AT LOW LEVELS IN GROUNDWATER. ON NOVEMBER 2, 2000, SECOR SUBMITTED A RISK-BASED CORRECTIVE ACTION (RBCA) ASSESSMENT FOR THE SITE WHICH IDENTIFIED BENZENE AND MTBE AS TWO CHEMICALS OF POTENTIAL CONCERN (COPC) FOR SOIL AND GROUNDWATER. ANALYSIS OF HYPOTHETICAL RECEPTORS AND EXPOSURE PATHWAYS INDICATED THAT 1) ADVERSE NONCANCER HEALTH EFFECTS ARE NOT ANTICIPATED FOR ANY RECEPTOR UNDER THE EXPOSURE CONDITIONS EVALUATED IN THE RBCA ASSESSMENT; AND 2) ACCEPTABLE EXCESS LIFETIME CANCER RISKS ARE NOT ANTICIPATED FOR ANY RECEPTOR UNDER THE EXPOSURE CONDITIONS EVALUATED. THE SESOIL MODEL WAS ALSO USED IN THE RBCA ASSESSMENT TO DETERMINE MIGRATION POTENTIAL FOR MTBE SINCE IT HAS THE LOWEST TENDENCY TO SORB TO SOIL PARTICLES AND HIGH WATER SOLUBILITY. THE ANALYSIS INDICATED THAT A MAJORITY OF THE MTBE LEACHING FROM SOIL TO SHALLOW GROUNDWATER MAY ALREADY HAVE OCCURRED; THEREFORE, THE MODEL PREDICTED THAT MTBE WOULD NOT MIGRATE FROM SOIL TO GROUNDWATER IN THE UPPERMOST SATURATED ZONE IN A 30 YEAR TIME PERIOD. THE MAXIMUM DEPTH ASSUMED TO BE REACHED BY MTBE AT 30-YEARS WAS 77.69 FEET BGS (SECOR, 2000). ON DECEMBER 10, 2001, SECOR SUBMITTED SITE SUMMARY AND CLOSURE RECOMMENDATIONS OUTLINING SITE CHARACTERISTICS RELATIVE TO SPECIFIC REGIONAL WATER QUALITY CONTROL BOARD (RWQCB) - SAN FRANCISCO BAY REGION CLOSURE CRITERIA. IN SUMMARY, 1) THE LEAK HAS BEEN STOPPED AND ONGOING SOURCES ARE REMOVED AND REMEDIATED; 2) THE SITE HAS BEEN ADEQUATELY CHARACTERIZED; 3) LITTLE OR NO GROUNDWATER IMPACT CURRENTLY EXISTS AND NO GASOLINE CONSTITUENTS ARE FOUND AT LEVELS ABOVE ESTABLISHED MAXIMUM CONTAMINANT LEVELS (MCLS) OR OTHER APPLICABLE WATERQUALITY OBJECTIVES; 4) THE DISSOLVED HYDROCARBON PLUME IS NOT MIGRATING; 5) NO WATER WELLS, DEEPER DRINKING WATER AQUIFERS, SURFACE WATER, OR OTHER SENSITIVE RECEPTORS ARE LIKELY TO BE IMPACTED; AND 6) THE SITE PRESENTS NO SIGNIFICANT RISK TO HUMAN HEALTH OR THE ENVIRONMENT (SECOR, 2001A). QUARTERLY GROUNDWATER MONITORING CONTINUED THROUGH OCTOBER 2003 (SECOR, 2001B). THE DIRECTION OF GROUNDWATER FLOW BETWEEN 1999 AND 2003, WAS PRIMARILY TO THE EAST-NORTHEAST. THE HYDROSTRATIGRAPHY BENEATH THE SITE CONSISTED OF TWO GROUNDWATER-BEARING ZONES; AN UPPER ZONE REFERRED TO AS ôZONE A,ö AND A LOWER ZONE REFERRED TO AS ôZONE B.ö IN A DECEMBER 22, 2003 TRANSMITTAL FROM THE RWQCB - SAN FRANCISCO BAY REGION, CLOSURE STATUS FOR THE SITE WAS GRANTED BASED ON THE CONCLUSIONS FROM THE RBCA AND THE SITE SUMMARYAND CLOSURE RECOMMENDATIONS REPORTS THAT A CONTINUING THREAT TO GROUNDWATER, HUMAN HEALTH AND THE ENVIRONMENT FROM RESIDUAL PETROLEUM HYDROCARBONS DOES NOT EXIST AT THE SITE. REGULATORY JURISDICTION OVER THE SITE HAS SINCE TRANSFERRED 62 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES) TO THE CSCDEH LOCAL OVERSIGHT PROGRAM (LOP). ON FEBRUARY 12, 2007, THE CSCDEH DETERMINED THAT, DUE TO ELEVATED CONCENTRATIONS OF MTBE AND TPH-GRO IN THE OFF-SITE GROUNDWATER MONITORING WELL (MW-9) ASSOCIATED WITH THE ACTIVE USA PETROLEUM SERVICE STATION, SUFFICIENT JUSTIFICATION EXISTED TO REOPEN THE CASE FOR FURTHER INVESTIGATION (CSCDEH CASE NO. 14-771). IN PARTICULAR, GROUNDWATER AT THE SITE WAS LAST MONITORED PRIOR TO CLOSURE IN JULY 2003 WHEN DEPTH-TO-GROUNDWATER WAS BETWEEN 96 AND 98 FEET BGS. ACCORDING QUARTERLY REPORTS, DEPTH-TO-GROUNDWATER IN WELL MW-9 IS NOW OBSERVED AT 38 TO 44 FEET BGS. CSCDEH DIRECTED CHEVRON TO IMPLEMENT AN ADDITIONAL INVESTIGATION TO IDENTIFY ANY POTENTIAL RESIDUAL SOURCE(S) CONTRIBUTING TO LOCAL GROUNDWATER IMPACTS (CSCDEH, FEBRUARY 12, 2007). BETWEEN JULY 16 AND 19, 2007, SECOR ADVANCED EXPLORATORY BOREHOLES (B-4 THROUGH B-7) IN GROUNDWATER-BEARING ZONE A TO CHARACTERIZE PETROLEUM HYDROCARBON IMPACTS TO GROUNDWATER AND SOIL BENEATH THE SITE (SHOWN ON FIGURE 2). GROUNDWATER WAS ONLY ENCOUNTERED IN BOREHOLE B-7 AND THE TOTAL DEPTH INVESTIGATED WAS TO 65 FEET BGS. DUE TO CONCERNS ABOUT VERTICAL CROSS-CONTAMINATION, THE REMAINING SOIL BORINGS WERE NOT ADVANCED TO THE PREVIOUSLY ANTICIPATED DEPTH IN ZONE B. CONCENTRATIONS OF TPH-GRO, MTBE, AND TBA WERE ENCOUNTERED IN THE GROUNDWATER SAMPLE COLLECTED FROM BOREHOLE B-7, AND MTBE AND TBA WERE DETECTED IN SOIL AT BOREHOLES B-4, B-6, AND B-7. THE ACTIVE USA PETROLEUM-BRANDED SERVICE STATION IS LOCATED ADJACENT TO THE SITE ON THE NORTHWEST SIDE OF ERIN WAY (SHOWN ON FIGURE 2). THE USA PETROLEUM-BRANDED SERVICE STATION HAS AN OPEN ENVIRONMENTAL CASE REGULATED BY THE CSCDEH (CASE NO. 08S1W02E01F) AND IS MANAGED BY TESORO PETROLEUM COMPANIES INCORPORATED (TESORO) AND THEIR CONSULTANT, HORIZON ENVIRONMENTAL INCORPORATED. THE USA SITE HAS BEEN AN ACTIVE GASOLINE SERVICE STATION SINCE 1959. IN 1985, ULTRAMAR, INC. PURCHASED THE SITE AND OPERATED BEACON STATION NO. 3420. TESORO PURCHASED THE SITE FROM BEACON IN MAY 2002, AND THEN SOLD THE STATION TO USA PETROLEUM LATER THAT SAME YEAR. TESORO REMAINS THE ENVIRONMENTAL CASE RESPONSIBLE PARTY FOR THE SITE (HORIZON ENVIRONMENTAL, 2003A). THERE ARE CURRENTLY 15 GROUNDWATER MONITORING WELLS (VW-2, VW-3, VW-5, VW-6, VW-9, CB-2,CB-3, SW-1 AND MW-7 THROUGH MW-13) ASSOCIATED WITH THE USA SITE (SHOWN ON FIGURE 2). TWELVE OF THE 15 WELLS ARE LOCATED WITHIN THE USA SITE BOUNDARIES. WELLS MW-9 AND MW-12 ARE LOCATED OFF SITE TO THE SOUTH IN THE ERIN WAY RIGHT-OF-WAY; AND WELL MW-13 IS LOCATED OFFSITE TO THE EAST IN THE SHAMROCK DRIVE RIGHT-OF-WAY. QUARTERLY GROUNDWATER MONITORING HAS BEEN CONDUCTED SINCE LATE 1997. A SOIL VAPOR EXTRACTION SYSTEM STARTED OPERATION AT THE SITE ON JANUARY 1, 1995, AND PERIODICALLY OPERATED THROUGH NOVEMBER 2001, THEN STARTED UP AGAIN IN FEBRUARY 2002. AN OZONE SPARGE SYSTEM BEGAN OPERATION ON DECEMBER 15, 2004 (HORIZON ENVIRONMENTAL, 2007). THE DIRECTION OF GROUNDWATER FLOW IN THE TWO GROUNDWATER-BEARING ZONES BETWEEN 2001 AND 2007, VARIED FROM SOUTHEAST, TO NORTHWEST, TO NORTHEAST, AND MORE RECENTLY FROM THE NORTHWEST TO NORTHEAST. PREVIOUS WORK PREFORMED BY VARIOUS CONTRACTORS FOR USA PETROLEUM INDICATED THAT SOIL AND GROUNDWATER HAVE BEEN IMPACTED BY PETROLEUM HYDROCARBONS, INCLUDING TPH-GRO UP TO 120,000 PARTS PER MILLION (PPM) IN SOIL BENEATH THE USTS, AND DISSOLVED TPH-GRO, BENZENE, AND THE FUEL OXYGENATE MTBE IN GROUNDWATER AROUND THE USTS (HORIZON ENVIRONMENTAL, 2003B). REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK DISCOVERY OTHER 01/01/50 LEAK REPORTED OTHER 01/01/50 LEAK STOPPED REMEDIATION 01/01/50 EXCAVATION ENFORCEMENT 11/09/2015 STAFF LETTER RESPONSE 10/23/2015 REQUEST FOR CLOSURE - REGULATOR RESPONDED ENFORCEMENT 10/10/2014 STAFF LETTER RESPONSE 08/15/2014 SITE ASSESSMENT REPORT - REGULATOR RESPONDED RESPONSE 08/14/2014 REQUEST FOR CLOSURE - REGULATOR RESPONDED ENFORCEMENT 04/11/2014 STAFF LETTER 63 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES) TYPE OF ACTION:DATE:ACTION: ENFORCEMENT 04/04/2014 STAFF LETTER RESPONSE 02/07/2014 SOIL AND WATER INVESTIGATION WORKPLAN - REGULATOR RESPONDED ENFORCEMENT 12/16/2013 STAFF LETTER RESPONSE 12/16/2013 REQUEST FOR CLOSURE - REGULATOR RESPONDED RESPONSE 08/30/2013 PRELIMINARY SITE ASSESSMENT WORKPLAN - ADDENDUM - REGULATOR RESPONDED ENFORCEMENT 08/21/2013 STAFF LETTER ENFORCEMENT 06/24/2013 STAFF LETTER RESPONSE 07/31/2012 MONITORING REPORT - QUARTERLY RESPONSE 04/30/2012 MONITORING REPORT - QUARTERLY RESPONSE 01/31/2012 MONITORING REPORT - QUARTERLY RESPONSE 10/31/2011 MONITORING REPORT - QUARTERLY RESPONSE 08/31/2011 WELL INSTALLATION WORKPLAN ENFORCEMENT 07/27/2011 STAFF LETTER ENFORCEMENT 06/20/2011 STAFF LETTER RESPONSE 08/11/2009 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 06/09/2009 STAFF LETTER - #900296 RESPONSE 09/12/2008 SOIL AND WATER INVESTIGATION REPORT RESPONSE 03/23/2007 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 02/02/2007 STAFF LETTER - #7022 ENFORCEMENT 01/30/2007 NOTICE OF RESPONSIBILITY - #700301 ENFORCEMENT 12/22/2003 CLOSURE/NO FURTHER ACTION LETTER - #302221 ENFORCEMENT 12/01/2001 STAFF LETTER - #37911 ENFORCEMENT 09/15/2001 STAFF LETTER - #19970 ENFORCEMENT 06/15/2001 STAFF LETTER - #19968 ENFORCEMENT 03/16/2001 STAFF LETTER - #19966 ENFORCEMENT 02/06/2001 STAFF LETTER - #19972 ENFORCEMENT 11/14/2000 STAFF LETTER - #19964 ENFORCEMENT 12/29/1999 STAFF LETTER - #19958 ENFORCEMENT 08/24/1999 STAFF LETTER - #19938 ENFORCEMENT 06/14/1999 STAFF LETTER - #19936 ENFORCEMENT 11/26/1998 STAFF LETTER - #19931 ENFORCEMENT 11/09/1998 NOTICE OF RESPONSIBILITY - #19926 ENFORCEMENT 11/04/1998 STAFF LETTER - #19924 ENFORCEMENT 10/12/1998 STAFF LETTER - #19928 OTHER 09/10/1998 LEAK REPORTED OTHER 06/05/1998 LEAK DISCOVERY OTHER 06/05/1998 LEAK STOPPED REMEDIATION 06/05/1998 EXCAVATION STATUS HISTORY STATUS:DATE: OPEN - SITE ASSESSMENT 03/23/2007 OPEN - REOPEN CASE 01/29/2007 COMPLETED - CASE CLOSED 12/22/2003 64 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES) STATUS:DATE: OPEN - SITE ASSESSMENT 02/08/1999 OPEN - CASE BEGIN DATE 06/05/1998 OPEN - SITE ASSESSMENT 06/05/1998 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE STE 300 CITY: SAN JOSE CONTACT NAME: GERALD O'REGAN CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: GERALD.O'REGAN@DEH.SCCGOV.ORG ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: NOT REPORTED CITY: OAKLAND CONTACT NAME: JOHN WOLFENDEN CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: JWOLFENDEN@WATERBOARDS.CA.GOV Back to Report Summary 65 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 3 Distance from Property: 0.065 mi. (343 ft.) E Elevation: 231 ft. (Lower than TP) FACILITY INFORMATION ID#: 43-0287 NAME: CHEVRON ADDRESS: 1402 CAMDEN CAMPBELL, CA 94583 Back to Report Summary 66 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 3 Distance from Property: 0.065 mi. (343 ft.) E Elevation: 231 ft. (Lower than TP) LARWAY CHEVRON, 1402 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 0002CFCC Page 1 out of 3 67 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST) LARWAY CHEVRON, 1402 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 0002CFCC Page 2 out of 3 68 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) LARWAY CHEVRON, 1402 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 0002CFCC Page 3 out of 3 Back to Report Summary 69 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 3 Distance from Property: 0.065 mi. (343 ft.) E Elevation: 231 ft. (Lower than TP) 98354, 1402 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 0002D09B Page 1 out of 3 70 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) 98354, 1402 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 0002D09B Page 2 out of 3 71 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) 98354, 1402 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 0002D09B Page 3 out of 3 Back to Report Summary 72 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 3 Distance from Property: 0.065 mi. (343 ft.) E Elevation: 231 ft. (Lower than TP) SITE INFORMATION ID#: T0608500344 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02F07F SITE NAME: CHEVRON #9-8354 RESPONSIBLE PARTY: GREG BARTON ADDRESS: 1402 CAMDEN ADDRESS: PO BOX 6012 CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: OTHER GROUNDWATER (NOT USED FOR DRINKING WATER) CASE WAS REPORTED: 1998-09-10 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 2003-12-22 ENFORCEMENT TYPE: INFORMAL STAFF ENFORCEMENT LETTER ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 6 - REOPEN PREVIOUSLY CLOSED CASE LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA HLTH DEPT - TOXICS MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: TANK CLOSURE DATE LEAK WAS DISCOVERED: 1998-06-05 HOW THE CASE/LEAK WAS STOPPED: CLOSE TANK LEAK WAS STOPPED: 1998-06-05 CAUSE OF LEAK: UNKNOWN SOURCE OF LEAK: UNKNOWN LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: 0 SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1998-06-05 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: 1999-02-08 REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 73 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 74 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) MAP ID# 3 Distance from Property: 0.065 mi. (343 ft.) E Elevation: 231 ft. (Lower than TP) SITE INFORMATION ID#: T0608502222 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02F01F SITE NAME: CHEVRON #9-8354 RESPONSIBLE PARTY: DARRELL HOVANDER ADDRESS: 1402 CAMDEN AVE ADDRESS: 2 ANNABEL LANE SUITE 200 SAN JOSE, CA 95124 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1988-03-28 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1991-01-23 ENFORCEMENT TYPE: INFORMAL STAFF ENFORCEMENT LETTER ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: 2001-02-08 MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: 2.5 MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 1 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: 0 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: WASTE OIL/USED OIL QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1989-12-16 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 75 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 76 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 3 Distance from Property: 0.065 mi. (343 ft.) E Elevation: 231 ft. (Lower than TP) FACILITY INFORMATION FACILITY #: 23460 STATUS: ACTIVE BOE: 44-031913 JURISDICTION: SANTA CLARA COUNTY NAME: CHEVRON #8354 AGENCY: PUBLIC HEALTH, HAZARDOUS MTLS. ADDRESS: 1402 CAMDEN AVE CAMPBELL, CA 95008 TANK INFORMATION TANK #: 000001 CAPACITY: 7000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: PLUS UNLEADE CONTAINMENT: NOT REPORTED TANK #: 000002 CAPACITY: 7000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: PRM UNLEADED CONTAINMENT: NOT REPORTED TANK #: 000003 CAPACITY: 10000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: NOT REPORTED TANK #: 000004 CAPACITY: 1000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: OIL STORAGE TYPE: WASTE CONTENT: WASTE OIL CONTAINMENT: NOT REPORTED Back to Report Summary 77 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 3 Distance from Property: 0.065 mi. (343 ft.) E Elevation: 231 ft. (Lower than TP) FACILITY INFORMATION EPA ID#: CAR000249425 OWNER TYPE: PRIVATE NAME: CHEVRON 98354 OWNER NAME: CHEVRON USA ADDRESS: 1402 CAMDEN AVE OPERATOR TYPE: PRIVATE CAMPBELL, CA 95008 OPERATOR NAME: JOCKO RODRIGUEZ CONTACT NAME: JOCKO RODRIGUEZ CONTACT ADDRESS: PO BOX 6004 SAN RAMON CA 94583 CONTACT PHONE: 877-386-6044 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 09/08/2014 CERTIFICATION CERTIFICATION NAME:CERTIFICATION TITLE:CERTIFICATION SIGNED DATE: JOCKO RODRIGUEZ WASTE TRACKING TECH 09/05/2014 INDUSTRY CLASSIFICATION (NAICS) 56291 - REMEDIATION SERVICES SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 09/08/2014 NAME: CHEVRON 98354 GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: SMALL QUANTITY GENERATOR LAST UPDATED DATE: 09/19/2014 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS - NO EVALUATIONS REPORTED - VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE 122 78 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) D002 CORROSIVE WASTE UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 79 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) MAP ID# 3 Distance from Property: 0.065 mi. (343 ft.) E Elevation: 231 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608502222 BUSINESS NAME: CHEVRON #9-8354 ADDRESS: 1402 CAMDEN AVE SAN JOSE, CA 95124 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 01/23/1991 POTENTIAL CONTAMINATION: WASTE OIL / MOTOR / HYDRAULIC / LUBRICATING POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED REMEDIATION 01/01/50 EXCAVATION RESPONSE 12/24/2001 MONITORING REPORT - QUARTERLY ENFORCEMENT 11/29/2001 STAFF LETTER - #19907 ENFORCEMENT 02/08/1991 CLOSURE/NO FURTHER ACTION LETTER ENFORCEMENT 12/07/1990 NOTICE OF RESPONSIBILITY - #39396 OTHER 03/28/1988 LEAK REPORTED RESPONSE 03/28/1988 OTHER REPORT / DOCUMENT REMEDIATION 03/28/1988 EXCAVATION STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 01/23/1991 OPEN - SITE ASSESSMENT 12/16/1989 OPEN - CASE BEGIN DATE 03/28/1988 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE 80 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 81 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 4 Distance from Property: 0.067 mi. (354 ft.) NW Elevation: 234 ft. (Equal to TP) FACILITY INFORMATION ID#: 43-0003 NAME: 4 DAY TIRE STORE ADDRESS: 1311 CAMDEN CAMPBELL, CA Back to Report Summary 82 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 4 Distance from Property: 0.067 mi. (354 ft.) NW Elevation: 234 ft. (Equal to TP) TERRIBLE HERBST 77, 1311 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 00020976 Page 1 out of 2 83 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST) TERRIBLE HERBST 77, 1311 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 00020976 Page 2 out of 2 Back to Report Summary 84 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 4 Distance from Property: 0.067 mi. (354 ft.) NW Elevation: 234 ft. (Equal to TP) SITE INFORMATION ID#: T0608500075 REGIONAL CASE #: 43-0003 LOCAL CASE #: 08S1W02E03 SITE NAME: 4 DAY TIRE STORE RESPONSIBLE PARTY: BLANK RP ADDRESS: 1311 CAMDEN AVE ADDRESS: NOT REPORTED CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1986-06-11 CASE ENTERED INTO SYSTEM: 1997-05-30 CASE WAS REVIEWED: 1997-05-30 CASE WAS CLOSED: 1997-01-15 ENFORCEMENT TYPE: NOT REPORTED ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: N = NO INTER CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: REGIONAL BOARD LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:ARCHIVED 5/9/96 CONTROL NO 120-041 SRC 0904691 LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: TANK CLOSURE DATE LEAK WAS DISCOVERED: 1986-06-11 HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: 1986-06-11 CAUSE OF LEAK: STRUCTURAL FAILURE SOURCE OF LEAK: TANK LEAK CONFIRMATION: 1986-06-11 SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: (NT) * CODE NOT DEFINED BY REPORTING AGENCY 85 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: SANTA CLARA BASIN (2 BENEFICIAL USE: NOT REPORTED Back to Report Summary 86 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) MAP ID# 4 Distance from Property: 0.067 mi. (354 ft.) NW Elevation: 234 ft. (Equal to TP) FACILITY INFORMATION FACILITY #: 14186 STATUS: INACTIVE BOE: 44-026294 JURISDICTION: CITY OF CAMPBELL NAME: TERRIBLE HERBST #77 AGENCY: FIRE DEPARTMENT ADDRESS: 1311 CAMDEN AVE CAMPBELL, CA 95008 TANK INFORMATION TANK #: 000001 CAPACITY: 1000 INSTALLED: 01-01-71 REMOVED: 06-02-86 TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: LEADED CONTAINMENT: BARE STEEL TANK #: 000002 CAPACITY: 10000 INSTALLED: 01-01-71 REMOVED: 06-02-86 TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: BARE STEEL TANK #: 000003 CAPACITY: 8000 INSTALLED: 01-01-71 REMOVED: 06-02-86 TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: BARE STEEL Back to Report Summary 87 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 4 Distance from Property: 0.067 mi. (354 ft.) NW Elevation: 234 ft. (Equal to TP) FACILITY INFORMATION GLOBAL ID: T0608500075 BUSINESS NAME: 4 DAY TIRE STORE ADDRESS: 1311 CAMDEN AVE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: 43-0003 STATUS: COMPLETED - CASE CLOSED 01/15/1997 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK DISCOVERY OTHER 01/01/50 LEAK REPORTED OTHER 01/01/50 LEAK STOPPED ENFORCEMENT 01/15/1997 CLOSURE/NO FURTHER ACTION LETTER RESPONSE 01/15/1997 OTHER REPORT / DOCUMENT OTHER 06/11/1986 LEAK DISCOVERY OTHER 06/11/1986 LEAK STOPPED OTHER 06/11/1986 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 01/15/1997 OPEN - CASE BEGIN DATE 06/11/1986 OPEN - SITE ASSESSMENT 06/11/1986 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER 88 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: RB 2 CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 89 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 5 Distance from Property: 0.082 mi. (433 ft.) W Elevation: 236 ft. (Higher than TP) CAMPBELL M C, 1266 WHITE OAKS, CAMPBELL, CA 95008 UNIQUE ID: 000209DF Page 1 out of 2 90 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST) CAMPBELL M C, 1266 WHITE OAKS, CAMPBELL, CA 95008 UNIQUE ID: 000209DF Page 2 out of 2 Back to Report Summary 91 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 5 Distance from Property: 0.082 mi. (433 ft.) W Elevation: 236 ft. (Higher than TP) FACILITY INFORMATION FACILITY #: 28646 STATUS: ACTIVE BOE: NOT REPORTED JURISDICTION: CITY OF CAMPBELL NAME: CAMPBELL CENTER AGENCY: FIRE DEPARTMENT ADDRESS: 1266 WHITE OAKS AVE CAMPBELL, CA 95008 TANK INFORMATION TANK #: 000001 CAPACITY: 10000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: DIESEL CONTAINMENT: NOT REPORTED TANK #: 000002 CAPACITY: 500 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: OIL STORAGE TYPE: WASTE CONTENT: WASTE OIL CONTAINMENT: NOT REPORTED Back to Report Summary 92 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 5 Distance from Property: 0.096 mi. (507 ft.) NW Elevation: 236 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T10000005716 BUSINESS NAME: MIDAS ADDRESS: 1236 WHITE OAKS CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: CLEANUP PROGRAM SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 01/09/2015 POTENTIAL CONTAMINATION: 1,1,1-TRICHLOROETHANE (TCA), TETRACHLOROETHYLENE (PCE), TOTAL PETROLEUM HYDROCARBONS (TPH) POTENTIAL MEDIA AFFECTED: SOIL, SOIL VAPOR SITE HISTORY: SITE MANAGEMENT PLAN IN PLACE FOR THIS FACILITY. ANY CHANGE IN OCCUPANCY NEEDS TO BE REPORTED TO THE LOCAL AGENCY. SAMPLING CONDUCTED IN OCTOBER 2012 FOUND SOIL AND SOIL VAPOR CONTAMINATION. ELEVATED TPHD AND TPHMO IN THE AREA OF HYDRAULIC LIFTS. NO VOCS OR PCBS DETECTED. SOIL VAPOR SAMPLES COLLECTED AT BV6 AND BV9 REPORTED TO HAVE ELEVATED CONCENTRATIONS OF PCE AND 1,1,1-TCA IN SOIL VAPOR - CLOSE TO SCREENING LEVELS. REPORT CONCLUDED THE SOURCE OF THE VOCS IS UNKNOWN. BV6 WAS LOCATED IN THE HAZARDOUS WASTE STORAGE AREA OF THE SITE; BV9 WAS LOCATED OUTSIDE IN THE PARKING LOT. PCE SOIL VAPOR PLUME IDENTIFIED THAT APPEARS TO BE CENTERED IN THE AREA OF THE HAZARDOUS WASTE STORAGE AREA. THE SOIL VAPOR CONCENTRATIONS WERE DEMONSTRATED TO BE HIGHEST AT 5 FEET WITH CLEAR DECREASE DOWNWARD AND AT 1 FOOT BELOW THE BUILDING, WHICH HAS A CONCRETE FLOOR AND ROLL UP DOORS. THE PLUME APPEARS TO BE LOCALIZED. THE SITE IS A MIDAS AUTOMOTIVE REPAIR FACILITY WITH ROLL-UP DOORS, WHICH ARE OPEN DURING OPERATION. 2 HYDRAULIC LIFTS WERE CLOSED IN PLACE. ADDITIONAL SOIL SAMPLING IN THE VICINITY OF THESE CLOSED LIFTS DEFINED THE EXTENT OF TPHMO AND TPHD IN SOIL. LIMITED IN EXTENT. REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED ENFORCEMENT 01/09/2015 CLOSURE/NO FURTHER ACTION LETTER RESPONSE 12/19/2014 CORRESPONDENCE RESPONSE 12/15/2014 OTHER REPORT / DOCUMENT ENFORCEMENT 12/12/2014 STAFF LETTER RESPONSE 11/28/2014 SOIL VAPOR INTRUSION INVESTIGATION REPORT ENFORCEMENT 11/03/2014 NOTIFICATION - PUBLIC NOTICE OF CASE CLOSURE ENFORCEMENT 10/31/2014 STAFF LETTER RESPONSE 10/30/2014 SITE INVESTIGATION RESPONSE 10/30/2014 SITE INVESTIGATION RESPONSE 10/20/2014 REQUEST FOR CLOSURE - REGULATOR RESPONDED RESPONSE 08/15/2014 SOIL VAPOR INTRUSION INVESTIGATION REPORT ENFORCEMENT 08/07/2014 STAFF LETTER RESPONSE 08/04/2014 SOIL VAPOR INTRUSION INVESTIGATION WORKPLAN - REGULATOR RESPONDED 93 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES) TYPE OF ACTION:DATE:ACTION: ENFORCEMENT 06/06/2014 STAFF LETTER ENFORCEMENT 04/28/2014 SITE VISIT / INSPECTION / SAMPLING RESPONSE 04/28/2014 SOIL VAPOR INTRUSION INVESTIGATION WORKPLAN - REGULATOR RESPONDED ENFORCEMENT 04/11/2014 STAFF LETTER ENFORCEMENT 03/11/2014 STAFF LETTER ENFORCEMENT 02/27/2014 COST RECOVERY AGREEMENT ENFORCEMENT 02/19/2014 LETTER - NOTICE OTHER 02/18/2014 LEAK REPORTED RESPONSE 02/18/2014 CORRESPONDENCE RESPONSE 02/18/2014 OTHER REPORT / DOCUMENT STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 01/09/2015 OPEN - SITE ASSESSMENT 03/07/2014 OPEN - CASE BEGIN DATE 02/18/2014 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: NOT REPORTED CITY: OAKLAND CONTACT NAME: JOHN WOLFENDEN CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: JWOLFENDEN@WATERBOARDS.CA.GOV ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DR, SUITE 300 CITY: SAN JOSE CONTACT NAME: LANI LEE CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: LANI.LEE@DEH.SCCGOV.ORG Back to Report Summary 94 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 6 Distance from Property: 0.122 mi. (644 ft.) SW Elevation: 241 ft. (Higher than TP) FACILITY INFORMATION EPA ID#: CAD052173705 OWNER TYPE: PRIVATE NAME: MATHEWS & ASSOC DBA MIRACLE PAINT OWNER NAME: TOM MATHEWS ADDRESS: 1360 WHITEOAKS RD OPERATOR TYPE: PRIVATE CAMPBELL, CA 95008 OPERATOR NAME: NOT REQUIRED CONTACT NAME: NOT REPORTED CONTACT ADDRESS: 1360 WHITEOAKS RD CAMPBELL CA 95008 CONTACT PHONE: NOT REPORTED NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 09/01/1996 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) - NO NAICS INFORMATION REPORTED - SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 09/01/1996 NAME: MATHEWS & ASSOC DBA MIRACLE PAINT GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: SMALL QUANTITY GENERATOR LAST UPDATED DATE: 09/15/2000 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS - NO EVALUATIONS REPORTED - VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE - NO HAZARDOUS WASTE INFORMATION REPORTED - UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - 95 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 96 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) MAP ID# 6 Distance from Property: 0.122 mi. (644 ft.) SW Elevation: 241 ft. (Higher than TP) FACILITY INFORMATION EPA ID#: CAD983615717 OWNER TYPE: PRIVATE NAME: AUTO LECTRICS OWNER NAME: ALTERNATORS STARTERS ETC INC ADDRESS: 1360 WHITE OAKS RD D OPERATOR TYPE: NOT REPORTED CAMPBELL, CA 95008 OPERATOR NAME: NOT REPORTED CONTACT NAME: THOMAS CARROLL CONTACT ADDRESS: 1360 WHITE OAKS RD D CAMPBELL CA 95008 CONTACT PHONE: 4085593540 NON-NOTIFIER: NOT A NON-NOTIFIER DATE RECEIVED BY AGENCY: 01/03/1992 CERTIFICATION - NO CERTIFICATION REPORTED - INDUSTRY CLASSIFICATION (NAICS) 336322 - OTHER MOTOR VEHICLE ELECTRICAL AND ELECTRONIC EQUIPMENT MANUFACTURING SITE HISTORY (INCLUDES GENERATORS AND NON-GENERATORS) DATE RECEIVED BY AGENCY: 01/03/1992 NAME: AUTO LECTRICS GENERATOR CLASSIFICATION: SMALL QUANTITY GENERATOR CURRENT ACTIVITY INFORMATION GENERATOR STATUS: SMALL QUANTITY GENERATOR LAST UPDATED DATE: 06/27/2002 SUBJECT TO CORRECTIVE ACTION UNIVERSE: NO TDSFs POTENTIALLY SUBJECT TO CORRECTIVE ACTION UNDER 3004 (u)/(v) UNIVERSE: NO TDSFs ONLY SUBJECT TO CORRECTIVE ACTION UNDER DISCRETIONARY AUTHORITIES UNIVERSE: NO NON TSDFs WHERE RCRA CORRECTIVE ACTION HAS BEEN IMPOSED UNIVERSE: NO CORRECTIVE ACTION WORKLOAD UNIVERSE: NO IMPORTER: NO UNDERGROUND INJECTION: NO MIXED WASTE GENERATOR: NO UNIVERSAL WASTE DESTINATION FACILITY: NO RECYCLER: NO TRANSFER FACILITY: NO TRANSPORTER: NO USED OIL FUEL BURNER: NO ONSITE BURNER EXEMPTION: NO USED OIL PROCESSOR: NO FURNACE EXEMPTION: NO USED OIL FUEL MARKETER TO BURNER: NO USED OIL REFINER: NO SPECIFICATION USED OIL MARKETER: NO USED OIL TRANSFER FACILITY: NO USED OIL TRANSPORTER: NO COMPLIANCE, MONITORING AND ENFORCEMENT INFORMATION EVALUATIONS - NO EVALUATIONS REPORTED - VIOLATIONS - NO VIOLATIONS REPORTED - ENFORCEMENTS - NO ENFORCEMENTS REPORTED - HAZARDOUS WASTE - NO HAZARDOUS WASTE INFORMATION REPORTED - UNIVERSAL WASTE - NO UNIVERSAL WASTE REPORTED - 97 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) CORRECTIVE ACTION AREA - NO CORRECTIVE ACTION AREA INFORMATION REPORTED - CORRECTIVE ACTION EVENT - NO CORRECTIVE ACTION EVENT REPORTED - Back to Report Summary 98 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) MAP ID# 7 Distance from Property: 0.207 mi. (1,093 ft.) SE Elevation: 238 ft. (Higher than TP) FACILITY INFORMATION ID#: 43-1356 NAME: SMOG DOCTOR ADDRESS: 2270 CAMDEN SAN JOSE, CA 95008 Back to Report Summary 99 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE) MAP ID# 7 Distance from Property: 0.207 mi. (1,093 ft.) SE Elevation: 238 ft. (Higher than TP) FILLEM UP, 2270 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 00020676 Page 1 out of 3 100 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST) FILLEM UP, 2270 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 00020676 Page 2 out of 3 101 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) FILLEM UP, 2270 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 00020676 Page 3 out of 3 Back to Report Summary 102 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 7 Distance from Property: 0.207 mi. (1,093 ft.) SE Elevation: 238 ft. (Higher than TP) PERFECT TIMING, 2270 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 0002CE40 Page 1 out of 3 103 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) PERFECT TIMING, 2270 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 0002CE40 Page 2 out of 3 104 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) PERFECT TIMING, 2270 CAMDEN AVE, CAMPBELL, CA 95008 UNIQUE ID: 0002CE40 Page 3 out of 3 Back to Report Summary 105 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 7 Distance from Property: 0.207 mi. (1,093 ft.) SE Elevation: 238 ft. (Higher than TP) SITE INFORMATION ID#: T0608501333 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02F03F SITE NAME: SMOG DOCTOR RESPONSIBLE PARTY: AKBAR NAZEMIAN ADDRESS: 2270 CAMDEN AVE ADDRESS: 18856 HUNTER WY. SAN JOSE, CA 95124 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1990-07-23 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1995-03-29 ENFORCEMENT TYPE: NOTICE OF RESPONSIBILITY ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT REQUIRED NUMBER OF GASOLINE ANALYTICAL RESULTS: 0 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: WASTE OIL/USED OIL QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1990-08-27 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 106 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 107 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) MAP ID# 7 Distance from Property: 0.207 mi. (1,093 ft.) SE Elevation: 238 ft. (Higher than TP) FACILITY INFORMATION FACILITY #: 401681 STATUS: INACTIVE BOE: NOT REPORTED JURISDICTION: CITY OF SAN JOSE NAME: SMOG DOCTOR INC AGENCY: HAZARDOUS MATERIALS PROGRAM ADDRESS: 2270 CAMDEN AVE SAN JOSE, CA 95124 TANK INFORMATION TANK #: 000001 CAPACITY: 6000 INSTALLED: 01-01-01 REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: LEADED CONTAINMENT: BARE STEEL TANK #: 000002 CAPACITY: 4000 INSTALLED: 01-01-01 REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: LEADED CONTAINMENT: BARE STEEL TANK #: 000003 CAPACITY: 6000 INSTALLED: 01-01-01 REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: LEADED CONTAINMENT: BARE STEEL TANK #: 000004 CAPACITY: 4000 INSTALLED: 01-01-01 REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: BARE STEEL TANK #: 000005 CAPACITY: 250 INSTALLED: 01-01-01 REMOVED: NOT REPORTED TANK USE: OIL STORAGE TYPE: WASTE CONTENT: NOT REPORTED CONTAINMENT: BARE STEEL Back to Report Summary 108 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 7 Distance from Property: 0.207 mi. (1,093 ft.) SE Elevation: 238 ft. (Higher than TP) FACILITY INFORMATION FACILITY #: 42885 STATUS: ACTIVE BOE: 44-025767 JURISDICTION: SANTA CLARA COUNTY NAME: PERFECT TIMING AGENCY: PUBLIC HEALTH, HAZARDOUS MTLS. ADDRESS: 2270 CAMDEN AVE CAMPBELL, CA 95008 TANK INFORMATION TANK #: 000001 CAPACITY: 6000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: LEADED CONTAINMENT: NOT REPORTED TANK #: 000002 CAPACITY: 6000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: NOT REPORTED TANK #: 000003 CAPACITY: 4000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: NOT REPORTED TANK #: 000004 CAPACITY: 4000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: NOT REPORTED TANK #: 000005 CAPACITY: NOT REPORTED INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: OIL STORAGE TYPE: WASTE CONTENT: WASTE OIL CONTAINMENT: NOT REPORTED Back to Report Summary 109 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 7 Distance from Property: 0.207 mi. (1,093 ft.) SE Elevation: 238 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T0608501333 BUSINESS NAME: SMOG DOCTOR ADDRESS: 2270 CAMDEN AVE SAN JOSE, CA 95124 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 03/29/1995 POTENTIAL CONTAMINATION: WASTE OIL / MOTOR / HYDRAULIC / LUBRICATING POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED REMEDIATION 01/01/50 EXCAVATION ENFORCEMENT 03/29/1995 CLOSURE/NO FURTHER ACTION LETTER REMEDIATION 10/05/1991 EXCAVATION ENFORCEMENT 08/27/1990 NOTICE OF RESPONSIBILITY - #39398 RESPONSE 08/23/1990 OTHER REPORT / DOCUMENT RESPONSE 08/23/1990 OTHER REPORT / DOCUMENT RESPONSE 08/23/1990 OTHER REPORT / DOCUMENT OTHER 07/23/1990 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 03/29/1995 OPEN - SITE ASSESSMENT 08/27/1990 OPEN - CASE BEGIN DATE 07/23/1990 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE 110 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 111 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 8 Distance from Property: 0.221 mi. (1,167 ft.) N Elevation: 230 ft. (Lower than TP) FACILITY INFORMATION FACILITY #: 19207 STATUS: INACTIVE BOE: 44-026303 JURISDICTION: CITY OF CAMPBELL NAME: SOUTH BAY GUNITE, INC AGENCY: FIRE DEPARTMENT ADDRESS: 110 CURTNER AVE CAMPBELL, CA 95008 TANK INFORMATION TANK #: 000001 CAPACITY: 8000 INSTALLED: 01-01-01 REMOVED: 09-21-90 TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: LEADED CONTAINMENT: UNKNOWN TANK #: 000002 CAPACITY: 8000 INSTALLED: 01-01-01 REMOVED: 09-21-90 TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: DIESEL CONTAINMENT: UNKNOWN TANK #: 000003 CAPACITY: 1000 INSTALLED: 01-01-01 REMOVED: 09-21-90 TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: UNKNOWN TANK #: 000004 CAPACITY: 1000 INSTALLED: 01-01-01 REMOVED: 09-21-90 TANK USE: UNKNOWN STORAGE TYPE: PRODUCT CONTENT: J CONTAINMENT: UNKNOWN Back to Report Summary 112 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 8 Distance from Property: 0.221 mi. (1,167 ft.) N Elevation: 230 ft. (Lower than TP) SOUTH BAY GUNITE INC, 110 CURTNER AV, CAMPBELL, CA 95008 UNIQUE ID: 00020918 Page 1 out of 3 113 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST) SOUTH BAY GUNITE INC, 110 CURTNER AV, CAMPBELL, CA 95008 UNIQUE ID: 00020918 Page 2 out of 3 114 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) SOUTH BAY GUNITE INC, 110 CURTNER AV, CAMPBELL, CA 95008 UNIQUE ID: 00020918 Page 3 out of 3 Back to Report Summary 115 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 9 Distance from Property: 0.239 mi. (1,262 ft.) SW Elevation: 245 ft. (Higher than TP) FACILITY INFORMATION FACILITY #: 17719 STATUS: ACTIVE BOE: 44-026300 JURISDICTION: CITY OF CAMPBELL NAME: SERVICAR AGENCY: FIRE DEPARTMENT ADDRESS: 1506 WHITE OAKS RD CAMPBELL, CA 95008 TANK INFORMATION TANK #: 000001 CAPACITY: 500 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: OIL STORAGE TYPE: WASTE CONTENT: WASTE OIL CONTAINMENT: NOT REPORTED TANK #: 000002 CAPACITY: 10000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: NOT REPORTED Back to Report Summary 116 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 9 Distance from Property: 0.239 mi. (1,262 ft.) SW Elevation: 245 ft. (Higher than TP) FACILITY INFORMATION GEOSEARCH ID: 2689310899 FACILITY ID: 17 NAME: DURHAM TRANSPORTATION ADDRESS: 1506 WHITE OAKS RD CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS OTHER FACILITY NAME(S) LISTED FOR THIS SITE: DURHAM TRANSPORTATION PERMIT AGENCY: CAMPBELL,CUPERTINO,LOS GATOS,MORGAN HILL Back to Report Summary 117 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA) MAP ID# 9 Distance from Property: 0.239 mi. (1,262 ft.) SW Elevation: 245 ft. (Higher than TP) SERVICAR, 1506 WHITE OAKS RD, CAMPBELL, CA 95008 UNIQUE ID: 000207D7 Page 1 out of 2 118 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST) SERVICAR, 1506 WHITE OAKS RD, CAMPBELL, CA 95008 UNIQUE ID: 000207D7 Page 2 out of 2 Back to Report Summary 119 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 10 Distance from Property: 0.246 mi. (1,299 ft.) SE Elevation: 237 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T0608501521 BUSINESS NAME: UNOCAL #4328 ADDRESS: 3145 S BASCOM AVE SAN JOSE, CA 95101 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 09/04/1991 POTENTIAL CONTAMINATION: WASTE OIL / MOTOR / HYDRAULIC / LUBRICATING POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED REMEDIATION 01/01/50 EXCAVATION ENFORCEMENT 09/04/1991 CLOSURE/NO FURTHER ACTION LETTER ENFORCEMENT 07/15/1991 NOTICE OF RESPONSIBILITY - #39300 OTHER 06/06/1991 LEAK REPORTED RESPONSE 03/26/1991 OTHER REPORT / DOCUMENT REMEDIATION 02/07/1991 EXCAVATION STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 09/04/1991 OPEN - CASE BEGIN DATE 02/07/1991 OPEN - SITE ASSESSMENT 02/07/1991 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER 120 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 121 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 10 Distance from Property: 0.246 mi. (1,299 ft.) SE Elevation: 237 ft. (Higher than TP) FACILITY INFORMATION ID#: 43-1559 NAME: UNOCAL ADDRESS: 3145 BASCOM CAMPBELL, CA 95008 Back to Report Summary 122 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 10 Distance from Property: 0.246 mi. (1,299 ft.) SE Elevation: 237 ft. (Higher than TP) FACILITY INFORMATION ID#: 43-2109 NAME: UNOCAL ADDRESS: 3145 B BASCOM SAN JOSE, CA Back to Report Summary 123 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE) MAP ID# 10 Distance from Property: 0.246 mi. (1,299 ft.) SE Elevation: 237 ft. (Higher than TP) UNION OIL SS 4328, 3145 SOUTH BASCAM, CAMPBELL, CA 95008 UNIQUE ID: 00020A04 Page 1 out of 3 124 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST) UNION OIL SS 4328, 3145 SOUTH BASCAM, CAMPBELL, CA 95008 UNIQUE ID: 00020A04 Page 2 out of 3 125 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) UNION OIL SS 4328, 3145 SOUTH BASCAM, CAMPBELL, CA 95008 UNIQUE ID: 00020A04 Page 3 out of 3 Back to Report Summary 126 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 10 Distance from Property: 0.246 mi. (1,299 ft.) SE Elevation: 237 ft. (Higher than TP) SITE INFORMATION ID#: T0608501937 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02F06F SITE NAME: UNOCAL #4328 RESPONSIBLE PARTY: SCARTEEN CORPORATION ADDRESS: 3145 S BASCOM AVE ADDRESS: PO BOX 7600 SAN JOSE, CA 95101 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1995-01-19 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1996-01-12 ENFORCEMENT TYPE: NOT REPORTED ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 127 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 128 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) MAP ID# 10 Distance from Property: 0.246 mi. (1,299 ft.) SE Elevation: 237 ft. (Higher than TP) SITE INFORMATION ID#: T0608501521 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02F05F SITE NAME: UNOCAL #4328 RESPONSIBLE PARTY: RICK SISK ADDRESS: 3145 S BASCOM AVE ADDRESS: 2000 CROW CANYON PL., STE. 400 SAN JOSE, CA 95101 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1991-06-06 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1991-09-04 ENFORCEMENT TYPE: NOTICE OF RESPONSIBILITY ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT REQUIRED NUMBER OF GASOLINE ANALYTICAL RESULTS: 0 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: WASTE OIL/USED OIL QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1991-02-07 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 129 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 130 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 10 Distance from Property: 0.246 mi. (1,299 ft.) SE Elevation: 237 ft. (Higher than TP) FACILITY INFORMATION FACILITY #: 400890 STATUS: INACTIVE BOE: NOT REPORTED JURISDICTION: CITY OF SAN JOSE NAME: UNION 76 AGENCY: HAZARDOUS MATERIALS PROGRAM ADDRESS: 3145 S BASCOM AVE SAN JOSE, CA 95008 TANK INFORMATION TANK #: 000001 CAPACITY: 550 INSTALLED: 01-01-56 REMOVED: NOT REPORTED TANK USE: OIL STORAGE TYPE: WASTE CONTENT: NOT REPORTED CONTAINMENT: BARE STEEL Back to Report Summary 131 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 10 Distance from Property: 0.246 mi. (1,299 ft.) SE Elevation: 237 ft. (Higher than TP) FACILITY INFORMATION FACILITY #: 400890 STATUS: ACTIVE BOE: NOT REPORTED JURISDICTION: CITY OF SAN JOSE NAME: UNION 76 AGENCY: HAZARDOUS MATERIALS PROGRAM ADDRESS: 3145 S BASCOM AVE SAN JOSE, CA 95008 TANK INFORMATION TANK #: 000002 CAPACITY: 10000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: DIESEL CONTAINMENT: NOT REPORTED TANK #: 000003 CAPACITY: 12000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: NOT REPORTED TANK #: 000004 CAPACITY: 10000 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: M.V. FUEL STORAGE TYPE: PRODUCT CONTENT: REG UNLEADED CONTAINMENT: NOT REPORTED TANK #: 000005 CAPACITY: 520 INSTALLED: NOT REPORTED REMOVED: NOT REPORTED TANK USE: OIL STORAGE TYPE: WASTE CONTENT: NOT REPORTED CONTAINMENT: NOT REPORTED Back to Report Summary 132 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS) MAP ID# 10 Distance from Property: 0.246 mi. (1,299 ft.) SE Elevation: 237 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T0608501937 BUSINESS NAME: UNOCAL #4328 ADDRESS: 3145 S BASCOM AVE SAN JOSE, CA 95101 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 01/12/1996 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED ENFORCEMENT 01/12/1996 CLOSURE/NO FURTHER ACTION LETTER RESPONSE 01/12/1996 OTHER REPORT / DOCUMENT OTHER 01/19/1995 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 01/12/1996 OPEN - CASE BEGIN DATE 01/19/1995 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 133 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES) CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 134 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 11 Distance from Property: 0.249 mi. (1,315 ft.) SE Elevation: 241 ft. (Higher than TP) FACILITY INFORMATION ID#: 43-0236 NAME: CAMBRIAN NURSERY ADDRESS: 3175 BASCOM SAN JOSE, CA Back to Report Summary 135 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 11 Distance from Property: 0.249 mi. (1,315 ft.) SE Elevation: 241 ft. (Higher than TP) CAMBRIAN NURSERY AND FLORIST, 3175 SOUTH BASCOM AVENUE, CAMPBELL, CA 95008 UNIQUE ID: 0002CF71 Page 1 out of 2 136 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST) CAMBRIAN NURSERY AND FLORIST, 3175 SOUTH BASCOM AVENUE, CAMPBELL, CA 95008 UNIQUE ID: 0002CF71 Page 2 out of 2 Back to Report Summary 137 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST) MAP ID# 11 Distance from Property: 0.249 mi. (1,315 ft.) SE Elevation: 241 ft. (Higher than TP) SITE INFORMATION ID#: T0608502223 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02F02F SITE NAME: CAMBRIAN NURSERY RESPONSIBLE PARTY: KAREN LIERMAN ADDRESS: 3175 S BASCOM AVE ADDRESS: 20230 STEVENS CREEK BLVD. SAN JOSE, CA 95101 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1989-05-15 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1991-07-16 ENFORCEMENT TYPE: NOTICE OF RESPONSIBILITY ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT REQUIRED NUMBER OF GASOLINE ANALYTICAL RESULTS: 0 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: DIESEL FUEL OIL AND ADDITIVES QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1989-04-18 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 138 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 139 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST) MAP ID# 11 Distance from Property: 0.249 mi. (1,315 ft.) SE Elevation: 241 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T0608502223 BUSINESS NAME: CAMBRIAN NURSERY ADDRESS: 3175 S BASCOM AVE SAN JOSE, CA 95101 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 07/16/1991 POTENTIAL CONTAMINATION: DIESEL POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED REMEDIATION 01/01/50 EXCAVATION ENFORCEMENT 07/16/1991 CLOSURE/NO FURTHER ACTION LETTER ENFORCEMENT 03/12/1990 NOTICE OF RESPONSIBILITY - #39397 RESPONSE 03/12/1990 OTHER REPORT / DOCUMENT OTHER 05/15/1989 LEAK REPORTED REMEDIATION 05/15/1989 EXCAVATION STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 07/16/1991 OPEN - CASE BEGIN DATE 04/18/1989 OPEN - SITE ASSESSMENT 04/18/1989 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER 140 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 141 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 12 Distance from Property: 0.29 mi. (1,531 ft.) SE Elevation: 240 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T0608501827 BUSINESS NAME: CHEVRON ADDRESS: 3160 BASCOM AVE S SAN JOSE, CA 95124 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: 43-1975 STATUS: COMPLETED - CASE CLOSED 07/21/1994 POTENTIAL CONTAMINATION: DIESEL POTENTIAL MEDIA AFFECTED: OTHER GROUNDWATER (USES OTHER THAN DRINKING WATER) SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK DISCOVERY OTHER 01/01/50 LEAK REPORTED OTHER 01/01/50 LEAK STOPPED ENFORCEMENT 06/06/2003 * NO ACTION RESPONSE 06/06/2003 OTHER REPORT / DOCUMENT RESPONSE 06/05/2003 MONITORING REPORT - QUARTERLY RESPONSE 06/04/2003 MONITORING REPORT - QUARTERLY RESPONSE 06/03/2003 MONITORING REPORT - QUARTERLY RESPONSE 06/02/2003 MONITORING REPORT - QUARTERLY RESPONSE 06/01/2003 MONITORING REPORT - QUARTERLY RESPONSE 05/30/2003 TANK REMOVAL REPORT / UST SAMPLING REPORT RESPONSE 05/29/2003 OTHER REPORT / DOCUMENT RESPONSE 05/28/2003 OTHER REPORT / DOCUMENT RESPONSE 05/27/2003 MONITORING REPORT - QUARTERLY RESPONSE 05/26/2003 OTHER REPORT / DOCUMENT RESPONSE 05/25/2003 OTHER REPORT / DOCUMENT RESPONSE 05/24/2003 MONITORING REPORT - QUARTERLY RESPONSE 05/23/2003 OTHER REPORT / DOCUMENT OTHER 12/24/1992 LEAK DISCOVERY OTHER 12/24/1992 LEAK STOPPED OTHER 12/24/1992 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 07/21/1994 OPEN - CASE BEGIN DATE 12/24/1992 142 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: RB 2 CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 143 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 12 Distance from Property: 0.29 mi. (1,531 ft.) SE Elevation: 240 ft. (Higher than TP) FACILITY INFORMATION ID#: 43-1975 NAME: CHEVRON ADDRESS: 3160 BASCOM SAN JOSE, CA Back to Report Summary 144 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 12 Distance from Property: 0.29 mi. (1,531 ft.) SE Elevation: 240 ft. (Higher than TP) SITE INFORMATION ID#: T0608535477 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02L01F SITE NAME: CHEVRON #9-0835 RESPONSIBLE PARTY: MARK LAFFERTY ADDRESS: 3160 BASCOM ADDRESS: 6001 BOLLINGER CANYON RD SAN JOSE, CA 95124 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: DRINKING WATER AQUIFER CASE WAS REPORTED: 1997-01-26 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 2007-11-29 ENFORCEMENT TYPE: CLOSURE LETTER ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA HLTH DEPT - TOXICS MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: 1965-01-01 HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: 9999-09-09 CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: 0 SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: 2004-01-07 POLUTION CHARACTERIZATION: 1996-01-24 REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: 2005-04-05 CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 145 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 146 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 12 Distance from Property: 0.29 mi. (1,531 ft.) SE Elevation: 240 ft. (Higher than TP) SITE INFORMATION ID#: T0608501827 REGIONAL CASE #: 43-1975 LOCAL CASE #: SBS0806 SITE NAME: CHEVRON RESPONSIBLE PARTY: BLANK RP ADDRESS: 3160 BASCOM AVE S ADDRESS: NOT REPORTED SAN JOSE, CA 95124 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: OTHER GROUNDWATER (NOT USED FOR DRINKING WATER) CASE WAS REPORTED: 1992-12-24 CASE ENTERED INTO SYSTEM: 1992-12-24 CASE WAS REVIEWED: 1999-12-29 CASE WAS CLOSED: 1994-07-21 ENFORCEMENT TYPE: NO ACTION ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: REGIONAL BOARD LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: 1965-01-02 MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: 2200 MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 1 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: 0 CASE SUMMARY:MTBE REFLECTS HIGHEST CONCENTRATION (TAKEN 3/27/97) LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: TANK CLOSURE DATE LEAK WAS DISCOVERED: 1992-12-24 HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: 1992-12-24 CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: DIESEL FUEL OIL AND ADDITIVES QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 147 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: SANTA CLARA BASIN (2 BENEFICIAL USE: NOT REPORTED Back to Report Summary 148 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 12 Distance from Property: 0.29 mi. (1,531 ft.) SE Elevation: 240 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T0608535477 BUSINESS NAME: CHEVRON #9-0835 ADDRESS: 3160 BASCOM AVENUE SAN JOSE, CA 95124 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 11/29/2007 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: AQUIFER USED FOR DRINKING WATER SUPPLY SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED REMEDIATION 01/01/50 EXCAVATION REMEDIATION 01/01/50 IN SITU PHYSICAL/CHEMICAL TREATMENT (OTHER THAN SVE) ENFORCEMENT 11/29/2007 CLOSURE/NO FURTHER ACTION LETTER - #029211 ENFORCEMENT 12/06/2006 * NO ACTION - #606021 RESPONSE 02/17/2006 SOIL AND WATER INVESTIGATION REPORT ENFORCEMENT 10/14/2005 STAFF LETTER - #504101 RESPONSE 01/31/2005 MONITORING REPORT - QUARTERLY RESPONSE 01/30/2005 REMEDIAL PROGRESS REPORT RESPONSE 10/31/2004 MONITORING REPORT - QUARTERLY RESPONSE 10/30/2004 REMEDIAL PROGRESS REPORT RESPONSE 07/31/2004 MONITORING REPORT - QUARTERLY RESPONSE 07/30/2004 REMEDIAL PROGRESS REPORT ENFORCEMENT 06/25/2004 STAFF LETTER - #44212 RESPONSE 04/30/2004 MONITORING REPORT - QUARTERLY RESPONSE 01/31/2004 MONITORING REPORT - QUARTERLY REMEDIATION 01/07/2004 IN SITU PHYSICAL/CHEMICAL TREATMENT (OTHER THAN SVE) RESPONSE 10/31/2003 MONITORING REPORT - QUARTERLY RESPONSE 09/27/2003 OTHER REPORT / DOCUMENT RESPONSE 07/31/2003 MONITORING REPORT - QUARTERLY ENFORCEMENT 04/30/2003 STAFF LETTER - #41429 RESPONSE 04/30/2003 MONITORING REPORT - QUARTERLY RESPONSE 01/30/2003 MONITORING REPORT - QUARTERLY RESPONSE 10/30/2002 MONITORING REPORT - QUARTERLY ENFORCEMENT 08/26/2002 STAFF LETTER - #38544 149 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) TYPE OF ACTION:DATE:ACTION: RESPONSE 06/28/2002 OTHER REPORT / DOCUMENT RESPONSE 04/30/2002 MONITORING REPORT - QUARTERLY ENFORCEMENT 04/29/2002 STAFF LETTER - #37551 RESPONSE 04/22/2002 OTHER REPORT / DOCUMENT ENFORCEMENT 02/25/2002 STAFF LETTER - #37547 RESPONSE 01/30/2002 MONITORING REPORT - QUARTERLY ENFORCEMENT 12/16/2001 STAFF LETTER - #19656 RESPONSE 10/30/2001 MONITORING REPORT - QUARTERLY RESPONSE 08/15/2001 CORRECTIVE ACTION PLAN / REMEDIAL ACTION PLAN RESPONSE 07/30/2001 MONITORING REPORT - QUARTERLY RESPONSE 07/30/2001 MONITORING REPORT - QUARTERLY RESPONSE 07/15/2001 SOIL AND WATER INVESTIGATION REPORT ENFORCEMENT 06/26/2001 STAFF LETTER - #19652 RESPONSE 04/30/2001 MONITORING REPORT - QUARTERLY ENFORCEMENT 04/16/2001 STAFF LETTER - #19648 RESPONSE 01/30/2001 MONITORING REPORT - QUARTERLY ENFORCEMENT 09/15/2000 STAFF LETTER - #19641 RESPONSE 07/30/2000 MONITORING REPORT - QUARTERLY RESPONSE 06/08/2000 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 05/30/2000 STAFF LETTER - #19804 RESPONSE 10/31/1999 MONITORING REPORT - QUARTERLY RESPONSE 07/31/1999 MONITORING REPORT - QUARTERLY RESPONSE 07/02/1999 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 05/18/1999 STAFF LETTER - #19798 RESPONSE 04/30/1999 MONITORING REPORT - QUARTERLY RESPONSE 01/30/1999 MONITORING REPORT - QUARTERLY ENFORCEMENT 10/05/1998 STAFF LETTER - #19794 RESPONSE 07/30/1998 MONITORING REPORT - QUARTERLY RESPONSE 04/30/1998 MONITORING REPORT - QUARTERLY RESPONSE 01/30/1998 MONITORING REPORT - QUARTERLY RESPONSE 10/30/1997 MONITORING REPORT - QUARTERLY ENFORCEMENT 09/25/1997 STAFF LETTER - #19766 ENFORCEMENT 06/19/1997 * NO ACTION - #79916 RESPONSE 04/30/1997 MONITORING REPORT - QUARTERLY REMEDIATION 02/01/1997 EXCAVATION RESPONSE 01/30/1997 MONITORING REPORT - QUARTERLY ENFORCEMENT 01/26/1997 STAFF LETTER - #19757 OTHER 01/26/1997 LEAK REPORTED RESPONSE 01/26/1997 SOIL AND WATER INVESTIGATION REPORT ENFORCEMENT 12/12/1996 STAFF LETTER - #19759 STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 11/29/2007 150 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) STATUS:DATE: OPEN - VERIFICATION MONITORING 04/05/2005 OPEN - REMEDIATION 01/07/2004 OPEN - CASE BEGIN DATE 01/24/1996 OPEN - SITE ASSESSMENT 01/24/1996 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DR, SUITE 300 CITY: SAN JOSE CONTACT NAME: LANI LEE CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: LANI.LEE@DEH.SCCGOV.ORG Back to Report Summary 151 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 13 Distance from Property: 0.292 mi. (1,542 ft.) SE Elevation: 237 ft. (Higher than TP) FACILITY INFORMATION ID#: 43-1090 NAME: QUALITY TUNE UP ADDRESS: 3146 BASCOM SAN JOSE, CA 95124 Back to Report Summary 152 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 13 Distance from Property: 0.292 mi. (1,542 ft.) SE Elevation: 237 ft. (Higher than TP) SITE INFORMATION ID#: T0608501082 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02F04F SITE NAME: QUALITY TUNE-UP #4 RESPONSIBLE PARTY: ROY & ROBERTA BORGONOVO ADDRESS: 3146 S BASCOM AVE ADDRESS: 3031 TISCH WAY, SUITE 610 SAN JOSE, CA 95118 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: DRINKING WATER AQUIFER CASE WAS REPORTED: 1990-10-12 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1998-07-24 ENFORCEMENT TYPE: INFORMAL STAFF ENFORCEMENT LETTER ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: 1998-04-07 MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: 5 MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 1 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1990-10-05 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: 1998-07-09 REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 153 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 154 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 13 Distance from Property: 0.291 mi. (1,536 ft.) SE Elevation: 237 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T0608501082 BUSINESS NAME: QUALITY TUNE-UP #4 ADDRESS: 3146 S BASCOM AVE SAN JOSE, CA 95118 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 07/24/1998 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: AQUIFER USED FOR DRINKING WATER SUPPLY SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED ENFORCEMENT 07/24/1998 CLEAN UP FUND - LETTER TO RP RESPONSE 07/24/1998 OTHER REPORT / DOCUMENT RESPONSE 07/15/1998 MONITORING REPORT - QUARTERLY RESPONSE 04/15/1998 MONITORING REPORT - QUARTERLY RESPONSE 01/15/1998 MONITORING REPORT - QUARTERLY RESPONSE 10/15/1997 MONITORING REPORT - QUARTERLY ENFORCEMENT 06/09/1997 STAFF LETTER - #19913 RESPONSE 11/30/1995 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 10/16/1995 STAFF LETTER - #19909 OTHER 10/12/1990 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 07/24/1998 OPEN - SITE ASSESSMENT 07/09/1998 OPEN - CASE BEGIN DATE 10/05/1990 OPEN - SITE ASSESSMENT 10/05/1990 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED 155 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 156 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 14 Distance from Property: 0.319 mi. (1,684 ft.) SE Elevation: 245 ft. (Higher than TP) FACILITY INFORMATION ID#: 43-2205 NAME: CROFT EQUIPMENT RENTALS ADDRESS: 3260 BASCOM SAN JOSE, CA 95124 Back to Report Summary 157 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 14 Distance from Property: 0.319 mi. (1,684 ft.) SE Elevation: 245 ft. (Higher than TP) SITE INFORMATION ID#: T0608598719 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02L02F SITE NAME: CROFT EQUIPMENT RENTALS RESPONSIBLE PARTY: MOCKABEE ENTERPRISES ADDRESS: 3260 BASCOM AVE ADDRESS: 3260 BASCOM AVENUE SAN JOSE, CA 95124 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1997-10-20 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1998-01-06 ENFORCEMENT TYPE: NOT REPORTED ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 158 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 159 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 14 Distance from Property: 0.319 mi. (1,684 ft.) SE Elevation: 245 ft. (Higher than TP) SITE INFORMATION ID#: T0608502023 REGIONAL CASE #: 43-2205 LOCAL CASE #: 43-2205 SITE NAME: CROFT EQUIPMENT RENTALS RESPONSIBLE PARTY: NOT REPORTED ADDRESS: 3260 BASCOM AVE S ADDRESS: NOT REPORTED SAN JOSE, CA 95124 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: UNDETERMINED CASE WAS REPORTED: 01/13/98 CASE ENTERED INTO SYSTEM: 01/13/98 CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 01/12/98 ENFORCEMENT TYPE: NOT REPORTED ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: NOT REPORTED PROGRAM FOR THE CASE: NOT REPORTED INTERIM FOR THE CASE: N = NO INTER CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: NOT REPORTED MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: NOT REPORTED CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: TANK CLOSURE DATE LEAK WAS DISCOVERED: 01/13/98 HOW THE CASE/LEAK WAS STOPPED: CLOSE TANK LEAK WAS STOPPED: 01/13/98 CAUSE OF LEAK: OVERFILL SOURCE OF LEAK: TANK LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NO ACTION 160 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 7428.12822618732 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: NOT REPORTED Back to Report Summary 161 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 14 Distance from Property: 0.319 mi. (1,684 ft.) SE Elevation: 245 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T0608598719 BUSINESS NAME: CROFT EQUIPMENT RENTALS ADDRESS: 3260 BASCOM AVE SAN JOSE, CA 95124 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 01/06/1998 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED OTHER 10/20/1997 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 01/06/1998 OPEN - CASE BEGIN DATE 10/20/1997 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC 162 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 163 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 15 Distance from Property: 0.378 mi. (1,996 ft.) NW Elevation: 230 ft. (Lower than TP) SITE INFORMATION ID#: T0608578224 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W03A03F SITE NAME: WEST VALLEY SANITATION DIST RESPONSIBLE PARTY: PETER SEVCIK ADDRESS: 100 E SUNNYOAKS AVE ADDRESS: 100 E. SUNNYOAKS AVE CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: OTHER GROUNDWATER (NOT USED FOR DRINKING WATER) CASE WAS REPORTED: 2002-10-01 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 2004-05-14 ENFORCEMENT TYPE: INFORMAL STAFF ENFORCEMENT LETTER ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: 2003-10-21 MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: .5 MAXIMUM SOIL CONCENTRATION OF MTBE: 4.16 NUMBER OF MTBE ANALYTICAL RESULTS: 3 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: UNKNOWN SOURCE OF LEAK: UNKNOWN LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 2002-11-08 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 164 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 165 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST) MAP ID# 15 Distance from Property: 0.378 mi. (1,996 ft.) NW Elevation: 230 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608578224 BUSINESS NAME: WEST VALLEY SANITATION DIST ADDRESS: 100 E SUNNYOAKS AVE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 05/14/2004 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: OTHER GROUNDWATER (USES OTHER THAN DRINKING WATER) SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED REMEDIATION 01/01/50 EXCAVATION RESPONSE 11/17/2003 SOIL AND WATER INVESTIGATION REPORT ENFORCEMENT 09/03/2003 STAFF LETTER - #42070 RESPONSE 08/18/2003 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 06/19/2003 STAFF LETTER - #41593 ENFORCEMENT 06/10/2003 NOTICE OF RESPONSIBILITY - #41527 REMEDIATION 10/15/2002 EXCAVATION OTHER 10/01/2002 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 05/14/2004 OPEN - SITE ASSESSMENT 11/08/2002 OPEN - CASE BEGIN DATE 10/01/2002 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE 166 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: BARBARA SIEMINSKI CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: BSIEMINSKI@WATERBOARDS.CA.GOV Back to Report Summary 167 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 16 Distance from Property: 0.379 mi. (2,001 ft.) W Elevation: 234 ft. (Equal to TP) FACILITY INFORMATION ID #: 43360018 NAME: HAWKES MAGNETIC ADDRESS: 1190 DELL AVENUE CAMPBELL, CA STATUS (DATE): PROPERTY/SITE REFERRED TO RWQCB (06081994) STANDARD INDUSTRIAL CLASSIFICATION BELIEVED TO BE CAUSE OF (POTENTIAL) CONTAMINATION: MANU - ELECTRONIC & OTHER ELECTRIC EQUIP ACCESS TO SITE: NOT REPORTED GROUNDWATER CONTAMINATION: NOT REPORTED COMMENTS FACILITY IDENTIFIED REFERRED BY RWQCB FACILITY DRIVE-BY LIGHT INDUSTRIAL COMPLEX PAVED. HAWKES NOT AT THIS ADDRESS FACILITY DRIVE-BY SITE NOW H&H MACHINE SHOP FACILITY DRIVE-BY DRIVE BY. NO PROBLEM OBSERVED. SITE SCREENING DONE: LETTER FROM SF RWQCB ADDRESSED TO AMERICAN AUTO INDUSTRIES. PA BY EPA 12/01/86. DTSC NEEDS TO DETERMINE SITE STATUS. Back to Report Summary 168 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES) MAP ID# 16 Distance from Property: 0.379 mi. (2,001 ft.) W Elevation: 234 ft. (Equal to TP) ID#: 000043360018 NAME: HAWKES MAGNETIC ADDRESS: 1190 DELL AVENUE CAMPBELL, CA 95008 COUNTY: SANTA CLARA DTSC BRANCH: NORTH COAST REGIONAL WATER QUALITY BOARD: SAN FRANCISCO BAY LEAD AGENCY: N/A STATUS: 06081994 - PROPERTY/SITE REFERRED TO RWQCB SITE TYPE: N/A STANDARD INDUSTRIAL CLASSIFICATION: MANU - ELECTRONIC & OTHER ELECTRIC EQUIP NPL: NOT REPORTED STAFF: NOT REPORTED SITE ACCESS: UNCONTROLLED CORTESE LISTING: NOT REPORTED HAZARD RANKING SCORE: NOT REPORTED HAZARD RANKING DATE: NOT REPORTED GROUNDWATER CONTAMINATION: UNKNOWN CAUSE OF RELEASE OR POTENTIAL FOR RELEASE OF A HAZARDOUS SUBSTANCE: NOT REPORTED COMMENTS BY DTSC STAFF: 01031982 FACILITY DRIVE-BY DRIVE BY. NO PROBLEM OBSERVED. 01151992 DTSC NEEDS TO DETERMINE SITE STATUS. 03181987 SITE SCREENING DONE: LETTER FROM SF RWQCB ADDRESSED TO AMERICAN AUTO INDUSTRIES. PA BY EPA 12/01/86. 08031981 FACILITY IDENTIFIED REFERRED BY RWQCB 10131981 FACILITY DRIVE-BY LIGHT INDUSTRIAL COMPLEX PAVED. HAWKES NOT AT THIS ADDRESS 10271981 FACILITY DRIVE-BY SITE NOW H&H MACHINE SHOP PROJECTED ACTIVITIES TO BE COMPLETED AT SITE: COMPLETION DATE: 08/03/1981 ACTIVITY: DISC NAME: DISCOVERY COMPLETION DATE: 03/18/1987 ACTIVITY: SS NAME: SITE SCREENING Back to Report Summary 169 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF) MAP ID# 16 Distance from Property: 0.379 mi. (2,001 ft.) W Elevation: 234 ft. (Equal to TP) FACILITY INFORMATION EPA ID#: CAD981368400 SITE ID#: 0902282 NAME: AMERICAN AUTOMATED INDUSTRIES ADDRESS: 1190 DELL AVE CAMPBELL, CA 95008 COUNTY: SANTA CLARA ACTION START DATE COMPLETION DATE RESPONSIBILITY DS - DISCOVERY NOT REPORTED 10/1/1986 EPA FUND PA - PRELIMINARY ASSESSMENT NOT REPORTED 12/1/1986 EPA FUND SI - SITE INSPECTION NOT REPORTED 9/1/1987 EPA FUND VS - ARCHIVE SITE NOT REPORTED 9/1/1987 EPA IN-HOUSE ACTION DESCRIPTIONS DS - (DISCOVERY) - THE PROCESS BY WHICH A POTENTIAL HAZARDOUS WASTE SITE IS BROUGHT TO THE ATTENTION OF THE EPA. THE PROCESS CAN OCCUR THROUGH THE USE OF SEVERAL MECHANISMS SUCH AS A PHONE CALL OR REFERRAL BY ANOTHER GOVERNMENT AGENCY. PA - (PRELIMINARY ASSESSMENT) - COLLECTION OF DIVERSE EXISTING INFORMATION ABOUT THE SOURCE AND NATURE OF THE SITE HAZARD. IT IS EPA POLICY TO COMPLETE THE PRELIMINARY ASSESSMENT WITHIN ONE YEAR OF SITE DISCOVERY. SI - (SITE INSPECTION) - THE PROCESS OF COLLECTING SITE DATA AND SAMPLES TO CHARACTERIZE THE SEVERITY OF THE HAZARD FOR THE HAZARD RANKING SCORE AND/OR ENFORCEMENT SUPPORT. VS - (ARCHIVE SITE) - THE DECISION IS MADE THAT NO FURTHER ACTIVITY IS PLANNED AT THE SITE. Back to Report Summary 170 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH) MAP ID# 16 Distance from Property: 0.379 mi. (2,001 ft.) W Elevation: 234 ft. (Equal to TP) SITE INFORMATION ID #: 43360018 ASSESSOR'S PARCEL #: 424-01-095 NAME: HAWKES MAGNETIC ADDRESS: 1190 DELL AVENUE CAMPBELL, CA 95008 COUNTY: SANTA CLARA SITE SIZE (ACRES): NOT REPORTED LEAD AGENCY: NONE SPECIFIED DTSC PROJECT MANAGER: NOT REPORTED DTSC SUPERVISOR: REFERRED - NOT ASSIGNED DTSC DIVISION BRANCH: CLEANUP BERKELEY NPL LISTED: NO RESTRICTED LAND USE: NO SITE TYPE: HISTORICAL SITE TYPE DESCRIPTION HISTORICAL: IDENTIFIES SITES FROM AN OLDER DATABASE WHERE NO SITE TYPE WAS IDENTIFIED. MOST OF THESE SITES HAVE A STATUS OF REFERRED OR NO FURTHER ACTION. DTSC IS WORKING TO CLEAN UP THIS DATA BY IDENTIFYING AN APPROPRIATE SITE TYPE FOR EACH “HISTORIC” SITE. DTSC's CURRENT INVOLVEMENT AT SITE (as of 06/08/1994) REFER: RWQCB - PAST USE/S THAT CAUSED THE CONTAMINATION NONE SPECIFIED CONFIRMED CONTAMINANTS OF CONCERN NONESPECIFIED - NONE SPECIFIED Back to Report Summary 171 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR) MAP ID# 17 Distance from Property: 0.382 mi. (2,017 ft.) N Elevation: 223 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T10000004235 BUSINESS NAME: FORMER CALHOUN BROTHERS ADDRESS: 910 S. MCGLINCY LANE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: CLEANUP PROGRAM SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 11/20/2012 POTENTIAL CONTAMINATION: DIESEL, WASTE OIL / MOTOR / HYDRAULIC / LUBRICATING POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: CAMPBELL FIRE DEPARTMENT RECORDS INDICATE THERE WERE 2 AST AT THIS SITE AND THERE WAS A RELEASE FROM ONE OF THE TANKS. THEY WERE DIRECTED BY CFD TO CLEANUP THE RELEASE. NO DOCUMENTATION OF THE CLEANUP OR COMPLETION NOTICE FROM THE CFD COULD BE FOUND. REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK DISCOVERY OTHER 01/01/50 LEAK REPORTED RESPONSE 12/24/2012 REMEDIAL PROGRESS REPORT ENFORCEMENT 11/20/2012 CLOSURE/NO FURTHER ACTION LETTER ENFORCEMENT 11/01/2012 STAFF LETTER ENFORCEMENT 10/24/2012 SITE VISIT / INSPECTION / SAMPLING ENFORCEMENT 10/23/2012 STAFF LETTER RESPONSE 10/08/2012 OTHER REPORT / DOCUMENT - REGULATOR RESPONDED ENFORCEMENT 08/28/2012 STAFF LETTER ENFORCEMENT 08/23/2012 LETTER - NOTICE RESPONSE 08/20/2012 SITE ASSESSMENT REPORT RESPONSE 07/20/2012 SITE INVESTIGATION WORKPLAN - REGULATOR RESPONDED ENFORCEMENT 07/03/2012 STAFF LETTER RESPONSE 06/28/2012 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 05/31/2012 STAFF LETTER ENFORCEMENT 05/29/2012 COST RECOVERY AGREEMENT RESPONSE 05/24/2012 SITE ASSESSMENT REPORT OTHER 05/17/2012 LEAK REPORTED RESPONSE 05/17/2012 CORRESPONDENCE RESPONSE 05/02/2012 SOIL AND WATER INVESTIGATION WORKPLAN RESPONSE 04/23/2012 OTHER REPORT / DOCUMENT OTHER 02/25/1987 LEAK DISCOVERY STATUS HISTORY 172 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES) STATUS:DATE: COMPLETED - CASE CLOSED 11/20/2012 OPEN - SITE ASSESSMENT 08/23/2012 OPEN - CASE BEGIN DATE 02/25/1987 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST., SUITE 1400 CITY: OAKLAND CONTACT NAME: NATHAN KING CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NKING@WATERBOARDS.CA.GOV ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DR, SUITE 300 CITY: SAN JOSE CONTACT NAME: LANI LEE CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: LANI.LEE@DEH.SCCGOV.ORG Back to Report Summary 173 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 18 Distance from Property: 0.398 mi. (2,101 ft.) N Elevation: 223 ft. (Lower than TP) SITE INFORMATION ID#: T0608502119 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W02D01F SITE NAME: WSP TRUCKING RESPONSIBLE PARTY: PUBLIC STORAGE PROPERTIES XIV ADDRESS: 175 S CURTNER AVE ADDRESS: PO BOX 25025 CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1985-08-15 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1999-10-29 ENFORCEMENT TYPE: INFORMAL STAFF ENFORCEMENT LETTER ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: 0 NUMBER OF MTBE ANALYTICAL RESULTS: 1 MTBE TESTED: YES NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1985-03-12 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 174 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 175 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST) MAP ID# 18 Distance from Property: 0.397 mi. (2,096 ft.) N Elevation: 223 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608502119 BUSINESS NAME: WSP TRUCKING ADDRESS: 175 S CURTNER AVE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 10/29/1999 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED ENFORCEMENT 10/29/1999 CLOSURE/NO FURTHER ACTION LETTER RESPONSE 10/29/1999 OTHER REPORT / DOCUMENT RESPONSE 06/15/1999 PRELIMINARY SITE ASSESSMENT REPORT ENFORCEMENT 04/27/1999 STAFF LETTER - #19824 RESPONSE 12/21/1998 SOIL AND WATER INVESTIGATION WORKPLAN ENFORCEMENT 11/19/1998 STAFF LETTER - #19822 ENFORCEMENT 09/24/1998 NOTICE OF RESPONSIBILITY - #39392 OTHER 08/15/1985 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 10/29/1999 OPEN - CASE BEGIN DATE 03/12/1985 OPEN - SITE ASSESSMENT 03/12/1985 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE 176 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 177 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 19 Distance from Property: 0.402 mi. (2,123 ft.) N Elevation: 222 ft. (Lower than TP) FACILITY INFORMATION ID#: 43-0985 NAME: HOUGE CONSTRUCTION ADDRESS: 210 VIETENHIEMER CAMPBELL, CA 95008 Back to Report Summary 178 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 19 Distance from Property: 0.402 mi. (2,123 ft.) N Elevation: 222 ft. (Lower than TP) SITE INFORMATION ID#: T0608521523 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 07S1W35P03F SITE NAME: HOUGE CONSTRUCTION RESPONSIBLE PARTY: NORMAN HOUGE ADDRESS: 210 VEITENHEIMER DR ADDRESS: 780 UNION AVE CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1991-10-03 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1997-08-18 ENFORCEMENT TYPE: NOT REPORTED ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 179 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 180 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 19 Distance from Property: 0.402 mi. (2,123 ft.) N Elevation: 222 ft. (Lower than TP) SITE INFORMATION ID#: T0608500984 REGIONAL CASE #: 43-0985 LOCAL CASE #: 43-0985 SITE NAME: HOUGE CONSTRUCTION RESPONSIBLE PARTY: NOT REPORTED ADDRESS: 210 VIETENHIEMER DR ADDRESS: NOT REPORTED CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 02/15/90 CASE ENTERED INTO SYSTEM: 04/28/90 CASE WAS REVIEWED: 02/24/99 CASE WAS CLOSED: 08/18/97 ENFORCEMENT TYPE: NOT REPORTED ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: NOT REPORTED PROGRAM FOR THE CASE: NOT REPORTED INTERIM FOR THE CASE: Y = INTERIM CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: NOT REPORTED MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT REQUIRED NUMBER OF GASOLINE ANALYTICAL RESULTS: NOT REPORTED CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: TANK CLOSURE DATE LEAK WAS DISCOVERED: 02/15/90 HOW THE CASE/LEAK WAS STOPPED: CLOSE TANK LEAK WAS STOPPED: 02/15/90 CAUSE OF LEAK: STRUCTURAL FAILURE SOURCE OF LEAK: TANK LEAK CONFIRMATION: 04/28/90 SUBSTANCE/S RELEASED: DIESEL FUEL OIL AND ADDITIVES QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: EXCAVATE AND DISPOSE 181 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 3833.49598733767 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: NOT REPORTED Back to Report Summary 182 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST) MAP ID# 19 Distance from Property: 0.402 mi. (2,123 ft.) N Elevation: 222 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608521523 BUSINESS NAME: HOUGE CONSTRUCTION ADDRESS: 210 VEITENHEIMER DR CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 08/18/1997 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED ENFORCEMENT 08/18/1997 CLOSURE/NO FURTHER ACTION LETTER OTHER 10/03/1991 LEAK REPORTED RESPONSE 01/01/1991 OTHER REPORT / DOCUMENT RESPONSE 01/01/1991 OTHER REPORT / DOCUMENT RESPONSE 01/01/1991 OTHER REPORT / DOCUMENT RESPONSE 01/01/1991 OTHER REPORT / DOCUMENT STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 08/18/1997 OPEN - CASE BEGIN DATE 10/03/1991 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 183 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 184 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 20 Distance from Property: 0.42 mi. (2,218 ft.) NW Elevation: 228 ft. (Lower than TP) FACILITY INFORMATION ID#: 43-2168 NAME: SPECIALTY DETAIL ADDRESS: 951 CAMDEN CAMPBELL, CA 95008 Back to Report Summary 185 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 20 Distance from Property: 0.42 mi. (2,218 ft.) NW Elevation: 228 ft. (Lower than TP) SITE INFORMATION ID#: T0608501992 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 07S1W34R03F SITE NAME: SPECIALTY DETAIL RESPONSIBLE PARTY: ROBERT SYKES ADDRESS: 951 CAMDEN AVE ADDRESS: 26932 BEATRICE LN CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1994-04-24 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1997-06-03 ENFORCEMENT TYPE: NOT REPORTED ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 186 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 187 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 20 Distance from Property: 0.419 mi. (2,212 ft.) NW Elevation: 228 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608501992 BUSINESS NAME: SPECIALTY DETAIL ADDRESS: 951 CAMDEN AVE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 06/03/1997 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED ENFORCEMENT 06/03/1997 CLOSURE/NO FURTHER ACTION LETTER RESPONSE 06/03/1997 OTHER REPORT / DOCUMENT OTHER 04/24/1994 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 06/03/1997 OPEN - CASE BEGIN DATE 04/24/1994 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 188 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 189 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 21 Distance from Property: 0.445 mi. (2,350 ft.) SE Elevation: 238 ft. (Higher than TP) FACILITY INFORMATION ID#: 43-0242 NAME: CAMPBELL UNIFIED SCHOOL D ADDRESS: 2225 CAMDEN SAN JOSE, CA Back to Report Summary 190 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 21 Distance from Property: 0.445 mi. (2,350 ft.) SE Elevation: 238 ft. (Higher than TP) SITE INFORMATION ID#: T0608500301 REGIONAL CASE #: 43-0242 LOCAL CASE #: 08S1W02K01 SITE NAME: CAMPBELL UNIFIED SCHOOL DISTRI RESPONSIBLE PARTY: BLANK RP ADDRESS: 2225 CAMDEN AVE ADDRESS: NOT REPORTED SAN JOSE, CA 95124 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1996-08-20 CASE ENTERED INTO SYSTEM: 1989-07-10 CASE WAS REVIEWED: 1995-12-15 CASE WAS CLOSED: 1995-12-15 ENFORCEMENT TYPE: NOT REPORTED ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: N = NO INTER CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: REGIONAL BOARD LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:ARCHIVED 5/17/96 CONTROL NO 120-050 SRC 0904700 LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: TANK CLOSURE DATE LEAK WAS DISCOVERED: 1989-06-16 HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: 1989-06-16 CAUSE OF LEAK: STRUCTURAL FAILURE SOURCE OF LEAK: TANK LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: NOT REPORTED REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: (NT) * CODE NOT DEFINED BY REPORTING AGENCY 191 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: SANTA CLARA BASIN (2 BENEFICIAL USE: NOT REPORTED Back to Report Summary 192 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 21 Distance from Property: 0.445 mi. (2,350 ft.) SE Elevation: 238 ft. (Higher than TP) FACILITY INFORMATION GLOBAL ID: T0608500301 BUSINESS NAME: CAMPBELL UNIFIED SCHOOL DISTRICT ADDRESS: 2225 CAMDEN AVE SAN JOSE, CA 95124 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: 43-0242 STATUS: COMPLETED - CASE CLOSED 12/15/1995 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK DISCOVERY OTHER 01/01/50 LEAK REPORTED OTHER 01/01/50 LEAK STOPPED RESPONSE 09/04/1996 OTHER REPORT / DOCUMENT OTHER 08/20/1996 LEAK REPORTED ENFORCEMENT 09/26/1995 CLOSURE/NO FURTHER ACTION LETTER OTHER 06/16/1989 LEAK DISCOVERY OTHER 06/16/1989 LEAK STOPPED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 12/15/1995 OPEN - CASE BEGIN DATE 06/16/1989 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER 193 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: RB 2 CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 194 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 22 Distance from Property: 0.449 mi. (2,371 ft.) W Elevation: 231 ft. (Lower than TP) FACILITY INFORMATION ID#: 43-0648 NAME: GLAGE UNDERGROUND CONSTRU ADDRESS: 1116 DELL CAMPBELL, CA 95008 Back to Report Summary 195 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 22 Distance from Property: 0.449 mi. (2,371 ft.) W Elevation: 231 ft. (Lower than TP) SITE INFORMATION ID#: T0608500682 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W03A01F SITE NAME: GLAGE UNDERGROUND CONSTRUCTION RESPONSIBLE PARTY: TOM GLAGE ADDRESS: 1116 DELL AVE ADDRESS: 1116 DELL AVE CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1988-01-08 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1992-02-24 ENFORCEMENT TYPE: NOTICE OF RESPONSIBILITY ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1991-03-07 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: 1991-12-09 CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 196 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 197 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 22 Distance from Property: 0.449 mi. (2,371 ft.) W Elevation: 231 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608500682 BUSINESS NAME: GLAGE UNDERGROUND CONSTRUCTION ADDRESS: 1116 DELL AVE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 02/24/1992 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED ENFORCEMENT 01/23/1996 STAFF LETTER - #43-0648 ENFORCEMENT 02/24/1992 CLOSURE/NO FURTHER ACTION LETTER RESPONSE 08/16/1989 OTHER REPORT / DOCUMENT RESPONSE 08/16/1989 OTHER REPORT / DOCUMENT ENFORCEMENT 08/03/1989 NOTICE OF RESPONSIBILITY - #39305 OTHER 01/08/1988 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 02/24/1992 OPEN - VERIFICATION MONITORING 12/09/1991 OPEN - SITE ASSESSMENT 03/07/1991 OPEN - CASE BEGIN DATE 01/08/1988 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE 198 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 199 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 23 Distance from Property: 0.452 mi. (2,387 ft.) N Elevation: 221 ft. (Lower than TP) FACILITY INFORMATION ID#: 43-0167 NAME: MELLO PIPELINES ADDRESS: 260 MCGLINCEY CAMPBELL, CA 95008 Back to Report Summary 200 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 23 Distance from Property: 0.452 mi. (2,387 ft.) N Elevation: 221 ft. (Lower than TP) SITE INFORMATION ID#: T0608500233 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 07S1W35N02F SITE NAME: MELLO PIPELINES RESPONSIBLE PARTY: TONY MELLO ADDRESS: 260 MCGLINCEY LN ADDRESS: 5109 INDEPENDENCE DR. CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: SOIL IMPACTED CASE WAS REPORTED: 1992-01-21 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1995-08-30 ENFORCEMENT TYPE: NOTICE OF RESPONSIBILITY ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1991-12-12 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 201 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 202 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 23 Distance from Property: 0.452 mi. (2,387 ft.) N Elevation: 221 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608500233 BUSINESS NAME: MELLO PIPELINES ADDRESS: 260 MCGLINCEY LN CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 08/30/1995 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: SOIL SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED ENFORCEMENT 08/30/1995 CLOSURE/NO FURTHER ACTION LETTER RESPONSE 04/19/1993 OTHER REPORT / DOCUMENT ENFORCEMENT 04/21/1992 NOTICE OF RESPONSIBILITY - #39458 OTHER 01/21/1992 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 08/30/1995 OPEN - CASE BEGIN DATE 12/12/1991 OPEN - SITE ASSESSMENT 12/12/1991 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED 203 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 204 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 24 Distance from Property: 0.454 mi. (2,397 ft.) W Elevation: 232 ft. (Lower than TP) FACILITY INFORMATION ID#: 43-0786 NAME: KILROY PEST CONTROL ADDRESS: 1175 DELL CAMPBELL, CA 95008 Back to Report Summary 205 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE) MAP ID# 24 Distance from Property: 0.454 mi. (2,397 ft.) W Elevation: 232 ft. (Lower than TP) SITE INFORMATION ID#: T0608500805 REGIONAL CASE #: NOT REPORTED LOCAL CASE #: 08S1W03A02F SITE NAME: KILROY PEST CONTROL RESPONSIBLE PARTY: PHILLIP OLAVARRI ADDRESS: 1175 DELL AVE ADDRESS: 1175 DELL AVENUE CAMPBELL, CA 95008 CROSS STREET: NOT REPORTED COUNTY: SANTA CLARA FACILITY OPERATOR: NOT REPORTED CASE INFORMATION CASE TYPE: DRINKING WATER AQUIFER CASE WAS REPORTED: 1991-01-10 CASE ENTERED INTO SYSTEM: NOT REPORTED CASE WAS REVIEWED: NOT REPORTED CASE WAS CLOSED: 1996-08-15 ENFORCEMENT TYPE: NOTICE OF RESPONSIBILITY ENFORCEMENT BEGAN: NOT REPORTED FUNDING TYPE: NOT REPORTED REGIONAL BOARD RESPONSIBLE FOR CASE: SAN FRANCISCO BAY REGIONAL WATER QUALITY CONTROL BOARD PROGRAM FOR THE CASE: LUST - LEAKING UNDERGROUND STORAGE TANK PROGRAM INTERIM FOR THE CASE: NOT REPORTED CURRENT STATUS: 9 - CASE CLOSED LEAD AGENCY: LOCAL AGENCY LEAD LOCAL AGENCY: SANTA CLARA VALLEY WATER DISTRICT UNDERGROUND STORAGE TANK PROGRAM UNIT MTBE CLASSIFICATION: NOT REPORTED MAXIMUM MTBE CONCENTRATION WAS FOUND: NOT REPORTED MAXIMUM GROUNDWATER CONCENTRATION OF MTBE: NOT REPORTED MAXIMUM SOIL CONCENTRATION OF MTBE: NOT REPORTED NUMBER OF MTBE ANALYTICAL RESULTS: 0 MTBE TESTED: NOT TESTED NUMBER OF GASOLINE ANALYTICAL RESULTS: 1 CASE SUMMARY:NOT REPORTED LEAKING TANK INFORMATION HOW THE CASE/LEAK WAS DISCOVERED: NOT REPORTED DATE LEAK WAS DISCOVERED: NOT REPORTED HOW THE CASE/LEAK WAS STOPPED: NOT REPORTED LEAK WAS STOPPED: NOT REPORTED CAUSE OF LEAK: NOT REPORTED SOURCE OF LEAK: NOT REPORTED LEAK CONFIRMATION: NOT REPORTED SUBSTANCE/S RELEASED: GASOLINE - AUTOMOTIVE QUANTITY OF SUBSTANCE RELEASED: NOT REPORTED SITE ASSESSMENT AND REMEDIAL ACTION INFORMATION PRELIMINARY SITE ASSESSEMENT WORKPLAN SUBMITTED: NOT REPORTED PRELIMINARY SITE ASSESSEMENT UNDERWAY: 1991-01-10 REMEDIAL ACTION UNDERWAY: NOT REPORTED POLUTION CHARACTERIZATION: NOT REPORTED REMEDIATION PLAN: NOT REPORTED VERIFICATION MONITORING UNDERWAY: NOT REPORTED CLEANUP FUND ID: NOT REPORTED PRIORITY: NOT REPORTED ABATEMENT METHOD: NOT REPORTED 206 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) ADDITIONAL INFORMATION WATER SYSTEM ID #: NOT REPORTED WATER WELL ID #: NOT REPORTED WATER SYSTEM FOR THE NEAREST PUBLIC DRINKING WATER WELL: NOT REPORTED WELL NAME FOR THE NEAREST DRINKING WATER WELL: NOT REPORTED DISTANCE TO NEAREST DRINKING WATER WELL: 0 GROUNDWATER BASIN: NOT REPORTED BENEFICIAL USE: MUNICIPAL AND DOMESTIC SUPPLY Back to Report Summary 207 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST) MAP ID# 24 Distance from Property: 0.454 mi. (2,397 ft.) W Elevation: 232 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T0608500805 BUSINESS NAME: KILROY PEST CONTROL ADDRESS: 1175 DELL AVE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: LUST CLEANUP SITE CASE NUMBER: NOT REPORTED STATUS: COMPLETED - CASE CLOSED 08/15/1996 POTENTIAL CONTAMINATION: GASOLINE POTENTIAL MEDIA AFFECTED: AQUIFER USED FOR DRINKING WATER SUPPLY SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: OTHER 01/01/50 LEAK REPORTED ENFORCEMENT 08/15/1996 CLOSURE/NO FURTHER ACTION LETTER RESPONSE 08/15/1996 OTHER REPORT / DOCUMENT ENFORCEMENT 11/08/1994 NOTICE OF RESPONSIBILITY - #39306 OTHER 01/10/1991 LEAK REPORTED STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 08/15/1996 OPEN - CASE BEGIN DATE 01/10/1991 OPEN - SITE ASSESSMENT 01/10/1991 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SANTA CLARA COUNTY LOP ADDRESS: 1555 BERGER DRIVE, SUITE 300 CITY: SAN JOSE CONTACT NAME: UST CASE WORKER CONTACT TYPE: LOCAL AGENCY CASEWORKER CONTACT PHONE: 4089183400 EMAIL: NOT REPORTED 208 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY STREET, SUITE 1400 CITY: OAKLAND CONTACT NAME: ZSC CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 209 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 25 Distance from Property: 0.494 mi. (2,608 ft.) W Elevation: 231 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T10000007802 BUSINESS NAME: VSL CORPORATION ADDRESS: 1077 DELL AVENUE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: CLEANUP PROGRAM SITE CASE NUMBER: 43S0708 STATUS: OPEN - ELIGIBLE FOR CLOSURE 10/16/2015 POTENTIAL CONTAMINATION: NOT REPORTED POTENTIAL MEDIA AFFECTED: NOT REPORTED SITE HISTORY: NOT REPORTED STATUS HISTORY STATUS:DATE: OPEN - CASE BEGIN DATE 10/16/2015 OPEN - ELIGIBLE FOR CLOSURE 10/16/2015 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: UUU CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 210 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 25 Distance from Property: 0.494 mi. (2,608 ft.) W Elevation: 231 ft. (Lower than TP) FACILITY INFORMATION GLOBAL ID: T10000007803 BUSINESS NAME: VSL CORPORATION ADDRESS: 1077 DELL AVENUE CAMPBELL, CA 95008 COUNTY: SANTA CLARA FACILITY DETAILS CASE TYPE: CLEANUP PROGRAM SITE CASE NUMBER: 43S0708 STATUS: COMPLETED - CASE CLOSED 10/16/2015 POTENTIAL CONTAMINATION: NOT REPORTED POTENTIAL MEDIA AFFECTED: NOT REPORTED SITE HISTORY: NOT REPORTED REGULATORY ACTIVITIES TYPE OF ACTION:DATE:ACTION: ENFORCEMENT 08/06/1996 CLOSURE/NO FURTHER ACTION LETTER - #43S0708 STATUS HISTORY STATUS:DATE: COMPLETED - CASE CLOSED 10/16/2015 OPEN - ELIGIBLE FOR CLOSURE 10/16/2015 OPEN - CASE BEGIN DATE 08/06/1996 CONTACT DETAILS ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: REGIONAL WATER BOARD CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED ORGANIZATION: SAN FRANCISCO BAY RWQCB (REGION 2) ADDRESS: 1515 CLAY ST SUITE 1400 CITY: OAKLAND CONTACT NAME: UUU CONTACT TYPE: REGIONAL BOARD CASEWORKER CONTACT PHONE: NOT REPORTED EMAIL: NOT REPORTED Back to Report Summary 211 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES) MAP ID# 26 Distance from Property: 0.507 mi. (2,677 ft.) N Elevation: 220 ft. (Lower than TP) SITE INFORMATION ID #: 71002130 ASSESSOR'S PARCEL #: NONE SPECIFIED NAME: PACIFIC AEROSPACE SVCS., INC. ADDRESS: 354 MCGLINCEY LANE CAMPBELL, CA 95008 COUNTY: SANTA CLARA SITE SIZE (ACRES): 0.5 LEAD AGENCY: SMBRP DTSC PROJECT MANAGER: MARK PIROS DTSC SUPERVISOR: MARK PIROS DTSC DIVISION BRANCH: CLEANUP BERKELEY NPL LISTED: NO RESTRICTED LAND USE: NO SITE TYPE: TIERED PERMIT SITE TYPE DESCRIPTION NOT REPORTED DTSC's CURRENT INVOLVEMENT AT SITE (as of 06/20/2012) INACTIVE - NEEDS EVALUATION - IDENTIFIES NON-ACTIVE SITES WHERE DTSC HAS DETERMINED A PEA OR OTHER EVALUATION IS REQUIRED PAST USE/S THAT CAUSED THE CONTAMINATION NONE SPECIFIED CONFIRMED CONTAMINANTS OF CONCERN NONESPECIFIED - NONE SPECIFIED Back to Report Summary 212 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR) MAP ID# 26 Distance from Property: 0.507 mi. (2,677 ft.) N Elevation: 220 ft. (Lower than TP) SITE INFORMATION ID #: 60000368 ASSESSOR'S PARCEL #: 412-31-012 NAME: PACIFIC AEROSPACE SERVICES ADDRESS: 354 EAST MCGLINCEY LANE CAMPBELL, CA 95008 COUNTY: SANTA CLARA SITE SIZE (ACRES): 1.25 LEAD AGENCY: HWMP DTSC PROJECT MANAGER: NOT REPORTED DTSC SUPERVISOR: DENISE TSUJI DTSC DIVISION BRANCH: CLEANUP BERKELEY NPL LISTED: NO RESTRICTED LAND USE: NO SITE TYPE: EVALUATION SITE TYPE DESCRIPTION EVALUATION: IDENTIFIES SUSPECTED, BUT UNCONFIRMED, CONTAMINATED SITES THAT NEED OR HAVE GONE THROUGH AN INVESTIGATION AND ASSESSMENT PROCESS. IF A SITE IS FOUND TO HAVE CONFIRMED CONTAMINATION, IT WILL CHANGE FROM EVALUATION TO EITHER A STATE RESPONSE OR VOLUNTARY CLEANUP SITE TYPE. SITES FOUND TO HAVE NO CONTAMINATION AT THE COMPLETION OF THE INVESTIGATION AND ASSESSMENT PROCESS RESULT IN A NO ACTION REQUIRED (FOR PHASE 1 ASSESSMENTS) OR NO FURTHER ACTION (FOR PHASE 2 ASSESSMENTS) DETERMINATION. DTSC's CURRENT INVOLVEMENT AT SITE (as of 05/24/2007) REFER: RCRA - PAST USE/S THAT CAUSED THE CONTAMINATION METAL PLATING - CHROME, METAL PLATING - OTHER CONFIRMED CONTAMINANTS OF CONCERN NONESPECIFIED - NONE SPECIFIED Back to Report Summary 213 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR) MAP ID# 27 Distance from Property: 0.711 mi. (3,754 ft.) SW Elevation: 248 ft. (Higher than TP) SITE INFORMATION ID #: 71003078 ASSESSOR'S PARCEL #: NONE SPECIFIED NAME: ASHLAND CHEMICAL CO., CAMPBELL ADDRESS: 1600 DELL AVENUE CAMPBELL, CA 95008 COUNTY: SANTA CLARA SITE SIZE (ACRES): NOT REPORTED LEAD AGENCY: NONE SPECIFIED DTSC PROJECT MANAGER: NOT REPORTED DTSC SUPERVISOR: NOT REPORTED DTSC DIVISION BRANCH: CLEANUP BERKELEY NPL LISTED: NO RESTRICTED LAND USE: NO SITE TYPE: TIERED PERMIT SITE TYPE DESCRIPTION NOT REPORTED DTSC's CURRENT INVOLVEMENT AT SITE (as of ) INACTIVE - NEEDS EVALUATION - IDENTIFIES NON-ACTIVE SITES WHERE DTSC HAS DETERMINED A PEA OR OTHER EVALUATION IS REQUIRED PAST USE/S THAT CAUSED THE CONTAMINATION NONE SPECIFIED CONFIRMED CONTAMINANTS OF CONCERN NONESPECIFIED - NONE SPECIFIED Back to Report Summary 214 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR) MAP ID# 28 Distance from Property: 0.962 mi. (5,079 ft.) SW Elevation: 263 ft. (Higher than TP) SITE INFORMATION ID #: 71003650 ASSESSOR'S PARCEL #: NONE SPECIFIED NAME: SILICON GENESIS CORP. ADDRESS: 590 DIVISION STREET CAMPBELL, CA 95008 COUNTY: SANTA CLARA SITE SIZE (ACRES): NOT REPORTED LEAD AGENCY: NONE SPECIFIED DTSC PROJECT MANAGER: NOT REPORTED DTSC SUPERVISOR: NOT REPORTED DTSC DIVISION BRANCH: CLEANUP BERKELEY NPL LISTED: NO RESTRICTED LAND USE: NO SITE TYPE: TIERED PERMIT SITE TYPE DESCRIPTION NOT REPORTED DTSC's CURRENT INVOLVEMENT AT SITE (as of ) INACTIVE - NEEDS EVALUATION - IDENTIFIES NON-ACTIVE SITES WHERE DTSC HAS DETERMINED A PEA OR OTHER EVALUATION IS REQUIRED PAST USE/S THAT CAUSED THE CONTAMINATION NONE SPECIFIED CONFIRMED CONTAMINANTS OF CONCERN NONESPECIFIED - NONE SPECIFIED Back to Report Summary 215 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR) This list contains sites that could not be mapped due to limited or incomplete address information. Database Name Site ID#Site Name Address City/State/Zip/County WMUDS 2 438072001 WDR-WATER TREATMENT SLUDGE DIS SE OF DIXON LANDING & HWY 17 SAN JOSE 216 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites Summary AIRSAFS Aerometric Information Retrieval System / Air Facility Subsystem VERSION DATE: 10/20/14 The United States Environmental Protection Agency (EPA) modified the Aerometric Information Retrieval System (AIRS) to a database that exclusively tracks the compliance of stationary sources of air pollution with EPA regulations: the Air Facility Subsystem (AFS). Since this change in 2001, the management of the AIRS/AFS database was assigned to EPA's Office of Enforcement and Compliance Assurance. BRS Biennial Reporting System VERSION DATE: 12/31/11 The United States Environmental Protection Agency (EPA), in cooperation with the States, biennially collects information regarding the generation, management, and final disposition of hazardous wastes regulated under the Resource Conservation and Recovery Act of 1976 (RCRA), as amended. The Biennial Report captures detailed data on the generation of hazardous waste from large quantity generators and data on waste management practices from treatment, storage and disposal facilities. Currently, the EPA states that data collected between 1991 and 1997 was originally a part of the defunct Biennial Reporting System and is now incorporated into the RCRAInfo data system. CDL Clandestine Drug Laboratory Locations VERSION DATE: 01/20/16 The U.S. Department of Justice ("the Department") provides this information as a public service. It contains addresses of some locations where law enforcement agencies reported they found chemicals or other items that indicated the presence of either clandestine drug laboratories or dumpsites. In most cases, the source of the entries is not the Department, and the Department has not verified the entry and does not guarantee its accuracy. Members of the public must verify the accuracy of all entries by, for example, contacting local law enforcement and local health departments. The Department does not establish, implement, enforce, or certify compliance with clean-up or remediation standards for contaminated sites; the public should contact a state or local health department or environmental protection agency for that information. DOCKETS EPA Docket Data VERSION DATE: 12/22/05 The United States Environmental Protection Agency Docket data lists Civil Case Defendants, filing dates as far back as 1971, laws broken including section, violations that occurred, pollutants involved, penalties assessed and superfund awards by facility and location. Please refer to ICIS database as source of current data. EC Federal Engineering Institutional Control Sites VERSION DATE: 08/03/15 This database includes site locations where Engineering and/or Institutional Controls have been identified as part 217 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL of a selected remedy for the site as defined by United States Environmental Protection Agency official remedy decision documents. A site listing does not indicate that the institutional and engineering controls are currently in place nor will be in place once the remedy is complete; it only indicates that the decision to include either of them in the remedy is documented as of the completed date of the document. Institutional controls are actions, such as legal controls, that help minimize the potential for human exposure to contamination by ensuring appropriate land or resource use. Engineering controls include caps, barriers, or other device engineering to prevent access, exposure, or continued migration of contamination. ERNSCA Emergency Response Notification System VERSION DATE: 02/21/16 This National Response Center database contains data on reported releases of oil, chemical, radiological, biological, and/or etiological discharges into the environment anywhere in the United States and its territories. The data comes from spill reports made to the U.S. Environmental Protection Agency, U.S. Coast Guard, the National Response Center and/or the U.S. Department of Transportation. ERNSIA Emergency Response Notification System VERSION DATE: 02/21/16 This National Response Center database contains data on reported releases of oil, chemical, radiological, biological, and/or etiological discharges into the environment anywhere in the United States and its territories. The data comes from spill reports made to the U.S. Environmental Protection Agency, U.S. Coast Guard, the National Response Center and/or the U.S. Department of Transportation. ERNSID Emergency Response Notification System VERSION DATE: 02/21/16 This National Response Center database contains data on reported releases of oil, chemical, radiological, biological, and/or etiological discharges into the environment anywhere in the United States and its territories. The data comes from spill reports made to the U.S. Environmental Protection Agency, U.S. Coast Guard, the National Response Center and/or the U.S. Department of Transportation. ERNSSD Emergency Response Notification System VERSION DATE: 02/21/16 This National Response Center database contains data on reported releases of oil, chemical, radiological, biological, and/or etiological discharges into the environment anywhere in the United States and its territories. The data comes from spill reports made to the U.S. Environmental Protection Agency, U.S. Coast Guard, the National Response Center and/or the U.S. Department of Transportation. FRSCA Facility Registry System VERSION DATE: 02/03/16 218 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL The United States Environmental Protection Agency's Office of Environmental Information (OEI) developed the Facility Registry System (FRS) as the centrally managed database that identifies facilities, sites or places subject to environmental regulations or of environmental interest. The Facility Registry System replaced the Facility Index System or FINDS database. FRSIA Facility Registry System VERSION DATE: 02/03/16 The United States Environmental Protection Agency's Office of Environmental Information (OEI) developed the Facility Registry System (FRS) as the centrally managed database that identifies facilities, sites or places subject to environmental regulations or of environmental interest. The Facility Registry System replaced the Facility Index System or FINDS database. FRSID Facility Registry System VERSION DATE: 02/03/16 The United States Environmental Protection Agency's Office of Environmental Information (OEI) developed the Facility Registry System (FRS) as the centrally managed database that identifies facilities, sites or places subject to environmental regulations or of environmental interest. The Facility Registry System replaced the Facility Index System or FINDS database. FRSSD Facility Registry System VERSION DATE: 02/03/16 The United States Environmental Protection Agency's Office of Environmental Information (OEI) developed the Facility Registry System (FRS) as the centrally managed database that identifies facilities, sites or places subject to environmental regulations or of environmental interest. The Facility Registry System replaced the Facility Index System or FINDS database. HMIRSR09 Hazardous Materials Incident Reporting System VERSION DATE: 11/08/15 The HMIRS database contains unintentional hazardous materials release information reported to the U.S. Department of Transportation located in EPA Region 9. This region includes the following states: Arizona, California, Hawaii, Nevada, and the territories of Guam and American Samoa. ICIS Integrated Compliance Information System (formerly DOCKETS) VERSION DATE: 12/06/15 ICIS is a case activity tracking and management system for civil, judicial, and administrative federal Environmental Protection Agency enforcement cases. ICIS contains information on federal administrative and 219 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL federal judicial cases under the following environmental statutes: the Clean Air Act, the Clean Water Act, the Resource Conservation and Recovery Act, the Emergency Planning and Community Right-to-Know Act - Section 313, the Toxic Substances Control Act, the Federal Insecticide, Fungicide, and Rodenticide Act, the Comprehensive Environmental Response, Compensation, and Liability Act, the Safe Drinking Water Act, and the Marine Protection, Research, and Sanctuaries Act. ICISNPDES Integrated Compliance Information System National Pollutant Discharge Elimination System VERSION DATE: 12/20/15 In 2006, the Integrated Compliance Information System (ICIS) - National Pollutant Discharge Elimination System (NPDES) became the NPDES national system of record for select states, tribes and territories. ICIS-NPDES is an information management system maintained by the United States Environmental Protection Agency's Office of Compliance to track permit compliance and enforcement status of facilities regulated by the NPDES under the Clean Water Act. ICIS-NPDES is designed to support the NPDES program at the state, regional, and national levels. LUCIS Land Use Control Information System VERSION DATE: 09/01/06 The LUCIS database is maintained by the U.S. Navy and contains information for former Base Realignment and Closure (BRAC) properties across the United States. MLTS Material Licensing Tracking System VERSION DATE: 02/12/16 MLTS is a list of approximately 8,100 sites which have or use radioactive materials subject to the United States Nuclear Regulatory Commission (NRC) licensing requirements. NPDESR09 National Pollutant Discharge Elimination System VERSION DATE: 04/01/07 Information in this database is extracted from the Water Permit Compliance System (PCS) database which is used by United States Environmental Protection Agency to track surface water permits issued under the Clean Water Act. This database includes permitted facilities located in EPA Region 9. This region includes the following states: Arizona, California, Hawaii, Nevada, and the territories of Guam and American Samoa. The NPDES database was collected from December 2002 until April 2007. Refer to the PCS and/or ICIS-NPDES database as source of current data. PADS PCB Activity Database System VERSION DATE: 07/01/14 The PCB Activity Database System (PADS) is used by the United States Environmental Protection Agency to 220 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL monitor the activities of polychlorinated biphenyls (PCB) handlers. PCSR09 Permit Compliance System VERSION DATE: 08/01/12 The Permit Compliance System is used in tracking enforcement status and permit compliance of facilities controlled by the National Pollutant Discharge Elimination System (NPDES) under the Clean Water Act and is maintained by the United States Environmental Protection Agency's Office of Compliance. PCS is designed to support the NPDES program at the state, regional, and national levels. This database includes permitted facilities located in EPA Region 9. This region includes the following states: Arizona, California, Hawaii, Nevada, and the territories of Guam and American Samoa. PCS has been modernized, and no longer exists. National Pollutant Discharge Elimination System (ICIS-NPDES) data can now be found in Integrated Compliance Information System (ICIS). RCRASC RCRA Sites with Controls VERSION DATE: 02/23/16 This list of Resource Conservation and Recovery Act sites with institutional controls in place is provided by the U.S. Environmental Protection Agency. SFLIENS CERCLIS Liens VERSION DATE: 06/08/12 A Federal CERCLA ("Superfund") lien can exist by operation of law at any site or property at which United States Environmental Protection Agency has spent Superfund monies. These monies are spent to investigate and address releases and threatened releases of contamination. CERCLIS provides information as to the identity of these sites and properties. This database contains those CERCLIS sites where the Lien on Property action is complete. SSTS Section Seven Tracking System VERSION DATE: 12/08/14 The United States Environmental Protection Agency tracks information on pesticide establishments through the Section Seven Tracking System (SSTS). SSTS records the registration of new establishments and records pesticide production at each establishment. The Federal Insecticide, Fungicide and Rodenticide Act (FIFRA) requires that production of pesticides or devices be conducted in a registered pesticide-producing or device- producing establishment. ("Production" includes formulation, packaging, repackaging, and relabeling.) TRI Toxics Release Inventory VERSION DATE: 12/31/13 The Toxics Release Inventory, provided by the United States Environmental Protection Agency, includes data on 221 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL toxic chemical releases and waste management activities from certain industries as well as federal and tribal facilities. This inventory contains information about the types and amounts of toxic chemicals that are released each year to the air, water, and land as well as information on the quantities of toxic chemicals sent to other facilities for further waste management. TSCA Toxic Substance Control Act Inventory VERSION DATE: 12/31/06 The Toxic Substances Control Act (TSCA) was enacted in 1976 to ensure that chemicals manufactured, imported, processed, or distributed in commerce, or used or disposed of in the United States do not pose any unreasonable risks to human health or the environment. TSCA section 8(b) provides the United States Environmental Protection Agency authority to "compile, keep current, and publish a list of each chemical substance that is manufactured or processed in the United States." This TSCA Chemical Substance Inventory contains non-confidential information on the production amount of toxic chemicals from each manufacturer and importer site. NLRRCRAG No Longer Regulated RCRA Generator Facilities VERSION DATE: 02/09/16 This database includes RCRA Generator facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. This listing includes facilities that formerly generated hazardous waste. Large Quantity Generators: Generate 1,000 kg or more of hazardous waste during any calendar month; or Generate more than 1 kg of acutely hazardous waste during any calendar month; or Generate more than 100 kg of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month; or Generate 1 kg or less of acutely hazardous waste during any calendar month, and accumulate more than 1kg of acutely hazardous waste at any time; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste during any calendar month, and accumulated more than 100 kg of that material at any time. Small Quantity Generators: Generate more than 100 and less than 1000 kilograms of hazardous waste during any calendar month and accumulate less than 6000 kg of hazardous waste at any time; or Generate 100 kg or less of hazardous waste during any calendar month, and accumulate more than 1000 kg of hazardous waste at any time. Conditionally Exempt Small Quantity Generators: Generate 100 kilograms or less of hazardous waste per calendar month, and accumulate 1000 kg or less of hazardous waste at any time; or Generate one kilogram or less of acutely hazardous waste per calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste. 222 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL RCRAGR09 Resource Conservation & Recovery Act - Generator Facilities VERSION DATE: 02/09/16 This database includes sites listed as generators of hazardous waste (large, small, and exempt) in the RCRAInfo system. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). This database includes sites located in EPA Region 9. This region includes the following states: Arizona, California, Hawaii, Nevada, and the territories of Guam and American Samoa. Large Quantity Generators: Generate 1,000 kg or more of hazardous waste during any calendar month; or Generate more than 1 kg of acutely hazardous waste during any calendar month; or Generate more than 100 kg of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month; or Generate 1 kg or less of acutely hazardous waste during any calendar month, and accumulate more than 1kg of acutely hazardous waste at any time; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste during any calendar month, and accumulated more than 100 kg of that material at any time. Small Quantity Generators: Generate more than 100 and less than 1000 kilograms of hazardous waste during any calendar month and accumulate less than 6000 kg of hazardous waste at any time; or Generate 100 kg or less of hazardous waste during any calendar month, and accumulate more than 1000 kg of hazardous waste at any time. Conditionally Exempt Small Quantity Generators: Generate 100 kilograms or less of hazardous waste per calendar month, and accumulate 1000 kg or less of hazardous waste at any time; or Generate one kilogram or less of acutely hazardous waste per calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste; or Generate 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, or acutely hazardous waste during any calendar month, and accumulate at any time: 1 kg or less of acutely hazardous waste; or 100 kg or less of any residue or contaminated soil, waste or other debris resulting from the cleanup of a spill, into or on any land or water, of acutely hazardous waste. RCRANGR09 Resource Conservation & Recovery Act - Non-Generator Facilities VERSION DATE: 02/09/16 This database identifies RCRAInfo system sites that only handle hazardous waste, such as transporters, without generating any amount hazardous waste. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). This database includes sites located in EPA Region 9. This region includes the following states: Arizona, California, Hawaii, Nevada, and the territories 223 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL of Guam and American Samoa. HISTPST Historical Gas Stations VERSION DATE: NR This historic directory of service stations is provided by the Cities Service Company. The directory includes Cities Service filling stations that were located throughout the United States in 1930. BF Brownfields Management System VERSION DATE: 01/28/16 Brownfields are real property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant. Cleaning up and reinvesting in these properties takes development pressures off of undeveloped, open land, and both improves and protects the environment. The United States Environmental Protection Agency maintains this database to track activities in the various brown field grant programs including grantee assessment, site cleanup and site redevelopment. This database included tribal brownfield sites. DNPL Delisted National Priorities List VERSION DATE: 07/22/15 This database includes sites from the United States Environmental Protection Agency’s Final National Priorities List (NPL) where remedies have proven to be satisfactory or sites where the original analyses were inaccurate, and the site is no longer appropriate for inclusion on the NPL, and final publication in the Federal Register has occurred. NLRRCRAT No Longer Regulated RCRA Non-CORRACTS TSD Facilities VERSION DATE: 02/09/16 This database includes RCRA Non-Corrective Action TSD facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. This listing includes facilities that formerly treated, stored or disposed of hazardous waste. ODI Open Dump Inventory VERSION DATE: 06/01/85 The open dump inventory was published by the United States Environmental Protection Agency. An “open dump” is defined as a facility or site where solid waste is disposed of which is not a sanitary landfill which meets the criteria promulgated under section 4004 of the Solid Waste Disposal Act (42 U.S.C. 6944) and which is not a facility for disposal of hazardous waste. This inventory has not been updated since June 1985. 224 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL RCRAT Resource Conservation & Recovery Act - Non-CORRACTS Treatment, Storage & Disposal Facilities VERSION DATE: 02/09/16 This database includes Non-Corrective Action sites listed as treatment, storage and/or disposal facilities of hazardous waste in the RCRAInfo system. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). SEMS Superfund Enterprise Management System VERSION DATE: 01/11/16 In 2014, the EPA Superfund Program implemented a new information system, the Superfund Enterprise Management System (SEMS). SEMS integrates multiple legacy systems into a comprehensive tracking and reporting tool. Efforts to migrate data to SEMS and to enhance data quality are now in the final stages. These datasets are a subset of reports previously generated by the CERCLIS legacy system and are now updated with SEMS. Additional reports are still undergoing quality assurance review and will be added at a later date. In these instances, reports from the final CERCLIS data set (dated November 12, 2013, which reflects official end of Fiscal Year 2013 Program progress) is still the most current information available. CERCLIS is the repository for site and non-site specific Superfund information in support of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA). This United States Environmental Protection Agency database contains an extract of sites that have been investigated or are in the process of being investigated for potential environmental risk. SEMSARCH Superfund Enterprise Management System Archived Site Inventory VERSION DATE: 01/11/16 This SEMS Archive List has replaced CERCLIS NFRAP. In 2014, the EPA Superfund Program implemented a new information system, the Superfund Enterprise Management System (SEMS). SEMS integrates multiple legacy systems into a comprehensive tracking and reporting tool. Efforts to migrate data to SEMS and to enhance data quality are now in the final stages. These datasets are a subset of reports previously generated by the CERCLIS legacy system and are now updated with SEMS. Additional reports are still undergoing quality assurance review and will be added at a later date. In these instances, reports from the final NFRAP data set (dated November 12, 2013, which reflects official end of Fiscal Year 2013 Program progress) is still the most current information available. NFRAP sites may be sites where, following an initial investigation, no contamination was found, contamination was removed quickly without the need for the site to be placed on the National Priorities List, or the contamination was not serious enough to require Federal Superfund action. DOD Department of Defense Sites VERSION DATE: 06/21/10 225 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL This information originates from the National Atlas of the United States Federal Lands data, which includes lands owned or administered by the Federal government. Army DOD, Army Corps of Engineers DOD, Air Force DOD, Navy DOD and Marine DOD areas of 640 acres or more are included. FUDS Formerly Used Defense Sites VERSION DATE: 06/01/15 The Formerly Used Defense Sites (FUDS) inventory includes properties previously owned by or leased to the United States and under Secretary of Defense Jurisdiction, as well as Munitions Response Areas (MRAs). The remediation of these properties is the responsibility of the Department of Defense. This data is provided by the U.S. Army Corps of Engineers (USACE), the boundaries/polygon data are based on preliminary findings and not all properties currently have polygon data available. DISCLAIMER: This data represents the results of data collection/processing for a specific USACE activity and is in no way to be considered comprehensive or to be used in any legal or official capacity as presented on this site. While the USACE has made a reasonable effort to insure the accuracy of the maps and associated data, it should be explicitly noted that USACE makes no warranty, representation or guaranty, either expressed or implied, as to the content, sequence, accuracy, timeliness or completeness of any of the data provided herein. For additional information on Formerly Used Defense Sites please contact the USACE Public Affairs Office at (202) 528-4285. NLRRCRAC No Longer Regulated RCRA Corrective Action Facilities VERSION DATE: 02/09/16 This database includes RCRA Corrective Action facilities that are no longer regulated by the United States Environmental Protection Agency or do not meet other RCRA reporting requirements. NPL National Priorities List VERSION DATE: 12/15/15 This database includes United States Environmental Protection Agency (EPA) National Priorities List sites that fall under the EPA's Superfund program, established to fund the cleanup of the most serious uncontrolled or abandoned hazardous waste sites identified for possible long-term remedial action. PNPL Proposed National Priorities List VERSION DATE: 07/22/15 This database contains sites proposed to be included on the National Priorities List (NPL) in the Federal Register. The United States Environmental Protection Agency investigates these sites to determine if they may present long-term threats to public health or the environment. RCRAC Resource Conservation & Recovery Act - Corrective Action Facilities VERSION DATE: 02/09/16 226 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL This database includes all hazardous waste sites with ongoing corrective action activity and where corrective action is statutorily required to be address but have not had corrective action imposed in the RCRAInfo system. The Corrective Action Program requires owners or operators of RCRA facilities (or treatment, storage, and disposal facilities) to investigate and cleanup contamination in order to protect human health and the environment. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). RCRASUBC Resource Conservation & Recovery Act - Subject to Corrective Action Facilities VERSION DATE: 02/09/16 This database includes hazardous waste sites which are potentially subject to corrective action regardless of whether they have correction action underway, plus any sites showing a corrective action event of RFI or beyond in the RCRAInfo system. Sites conducting corrective action under analogous state authorities are also included. The United States Environmental Protection Agency defines RCRAInfo as the comprehensive information system which provides access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. RCRAInfo replaces the data recording and reporting abilities of the Resource Conservation and Recovery Information System (RCRIS) and the Biennial Reporting System (BRS). RODS Record of Decision System VERSION DATE: 07/01/13 These decision documents maintained by the United States Environmental Protection Agency describe the chosen remedy for NPL (Superfund) site remediation. They also include site history, site description, site characteristics, community participation, enforcement activities, past and present activities, contaminated media, the contaminants present, and scope and role of response action. 227 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERAL CDL Clandestine Drug Labs VERSION DATE: 09/30/15 The California Department of Toxic Substance Control (DTSC) provides this listing of illegal drug laboratories. Pursuant to Section 25354.5 of the California Health and Safety Code, DTSC conducts emergency removal actions at clandestine drug labs at the request of State and local law enforcement agencies. DTSC’s contractors typically remove hazardous substances that may pose an immediate threat to public health and the environment while the enforcement officials are on scene. During the emergency removal actions, contractors remove and properly dispose of contaminated lab equipment, chemicals used to make the illegal drugs (usually methamphetamine), lab chemical wastes, and other grossly contaminated materials. DTSC does not perform additional assessment work beyond standard emergency removal actions and makes no further determination regarding the need for future cleanup work at the emergency removal location. The reported location information may or may not include the actual location of the illegal drug lab. The DTSC does not guarantee the accuracy of the address or location information or the condition of the location listed. CHMIRS California Hazardous Material Incident Report System VERSION DATE: 01/26/16 The California Hazardous Material Incident Report System database is provided by the California Emergency Management Agency. This database contains accidental or spill release information from reported hazardous material incidents since 1993. DTSCDR DTSC Deed Restrictions VERSION DATE: 02/09/16 The California Department of Toxic Substances Control (DTSC) maintains this listing of sites with deed restrictions. According to the DTSC, restricted land use indicates whether the site or area within the site has an environmental restriction recorded and/or other institutional control preventing certain types of land use or activities. The land use restrictions listed under the site management requirements are only an abbreviated summary of the land use restrictions, and may not encompass all restrictions and notification requirements placed on a property. For complete land use restriction information please contact the DTSC to review associated Land Use Restriction documents. EMI Emissions Inventory Data VERSION DATE: 12/31/14 The Air Resources Board's Emissions Inventory Database contains criteria pollutant data and toxic data on facilities throughout the state of California for the 2012-2000 inventory years. HWTS Hazardous Waste Tanner Summary VERSION DATE: 12/31/14 228 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA) This data is prepared from information extracted from copies of hazardous waste manifests received each year by the Department of Toxic Substances Control. The Hazardous Waste Summary Report (Tanner Report) currently includes manifest data from the 1993 through the 2013 reporting years. LIENS Recorded Environmental Cleanup Liens VERSION DATE: 10/06/15 The California Department of Toxic Substance Control (DTSC) maintains this listing of liens placed upon real properties. A lien is utilized by the DTSC to obtain reimbursement from responsible parties for costs associated with the remediation of contaminated properties. NPDES National Pollutant Discharge Elimination System Facilities VERSION DATE: 12/22/15 This State Water Resources Control Board database contains NPDES permits, including stormwater general permit enrollees that are active, inactive and historical. NPDES permits are required from all facilities that discharge their wastewater from a point source into a waterbody. ABST Above Ground Storage Tanks VERSION DATE: 12/01/07 This database contains aboveground storage tank facilities registered with the California State Water Resources Control Board (SWRCB). Since 2006, tanks were required to contain a minimum (even as cumulative) of 1320 gallons to be in the program. As of January 1, 2008, the SWRCB no longer maintains a list of registered aboveground storage tanks, due to effective Assembly Bill No. 1130 (Laird) of the Aboveground Petroleum Storage Act (APSA). This Bill authorized the Certified Unified Program Agencies to implement and administer the requirements of the APSA. CLEANER Dry Cleaner Facilities VERSION DATE: 06/01/15 This database, created by accessing the California Department of Toxic Substances Control’s (DTSC) Hazardous Waste Tracking System, includes dry cleaner facilities that have registered EPA identification numbers. These facilities are categorized with one of the following NAICS Codes: 81231 or 81232. This database may also include facilities other than dry cleaners who also register with these same NAICS Codes. Not all companies report their NAICS/SIC Codes to the DTSC and therefore this database may exclude registered dry cleaner facilities with incomplete classification information. DTSCHWT DTSC Registered Hazardous Waste Transporters VERSION DATE: 02/04/16 The Department of Toxic Substances Control provides this list of Registered Hazardous Waste Transporters. 229 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA) HISTUST Historical Underground Storage Tanks VERSION DATE: 12/31/87 The Hazardous Substance Storage Container Database is a historical list of Underground Storage Tank sites, compiled from tank survey and registration information collected at one time between 1984 and 1987 by the State Water Resources Control Board. The hazardous substances stored within these tanks includes, but not restricted to, petroleum products, industrial solvents, and other materials. MWMP California Medical Waste Management Program Facility List VERSION DATE: 01/22/16 To protect the public and the environment from potential infectious exposure to disease causing agents, the Medical Waste Management Program (MWMP), in the Environmental Management Branch of the California Department of Public Health, regulates the generation, handling, storage, treatment, and disposal of medical waste by providing oversight for the implementation of the Medical Waste Management Act (MWMA). The MWMP permits and inspects all medical waste off-site treatment facilities, medical waste transporters, and medical waste transfer stations. SLIC Spills, Leaks, Investigation & Cleanup Recovery Listing VERSION DATE: 06/16/08 These records are maintained by the California Regional Water Quality Control Board (RWQCB). This list includes contaminated sites that impact groundwater or have the potential to impact ground water. Please refer to CLEANUPSITES database as source of current data. SWEEPS Statewide Environmental Evaluation and Planning System VERSION DATE: 10/01/94 The Statewide Environmental Evaluation and Planning System (SWEEPS) contains a historical listing of active and inactive underground storage tank locations from the State Water Resources Control Board. The hazardous substances stored within these tanks includes, but not restricted to, petroleum products, industrial solvents, and other materials. Refer to CUPA listing for source of current data. USTCUPA Underground Storage Tanks VERSION DATE: 02/04/16 An underground storage tank is an individual tank or group of tanks that store hazardous substances. Underground storage tanks are completely or considerably below the ground surface. This database contains UST permit data submitted from the Certified Unified Program Agencies (CUPA) directly to the State Water Resources Control Board. CUPA's are local agencies that have been certified by the California EPA to implement state environmental programs within the local agency's jurisdiction. 230 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA) CALSITES CALSITES Database VERSION DATE: 09/14/04 This historical database was maintained by the Department of Toxic Substance Control for more than a decade. CALSITES contains information on Brownfield properties with confirmed or potential hazardous contamination. In 2006, DTSC introduced EnviroStor as the latest Brownfields site database. CLEANUPSITES GeoTracker Cleanup Sites VERSION DATE: 02/05/16 This GeoTracker Cleanup Sites database is maintained by the California Regional Water Quality Control Board (RWQCB). The database contains contaminated sites that impact groundwater or have the potential to impact ground water, including spills, investigations, cleanup recoveries and reported leaking underground storage tank incidents. CORTESE Cortese List VERSION DATE: 11/02/02 This historical listing includes hazardous waste and substances sites designated by the State Water Resources Control Board (LUST), the Integrated Waste Board (SWIS), and the Department of Toxic Substance Control (CALSITES). The Cortese List was utilized by the State, local agencies and developers to comply with the California Environmental Quality Act requirements in providing information about the location of hazardous materials release sites. ERAP Expedited Removal Action Program Sites VERSION DATE: 03/21/16 The Expedited Remedial Action Program is a pilot project administered by the Department of Toxic Substances Control's Site Mitigation and Brownfields Reuse Program to promote the cleanup of up to 30 hazardous substance release sites. ERAP provides significant incentives for redevelopment of contaminated properties by promoting cleanups based on the planned land use, by providing a covenant not to sue, and by outlining a fair and equitable liability scheme. LUST Leaking Underground Storage Tanks VERSION DATE: 06/16/08 This database is maintained by the State Water Resources Control Board. LUST records contain an inventory of reported leaking underground storage tank incidents. Please refer to the CLEANUPSITES database as source of current data. 231 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA) NFA No Further Action Determination VERSION DATE: 07/01/05 The NFA listing contains properties at which the Department of Toxic Substance Control has made a clear determination that the property does not pose a problem to the environment or to public health. NFE Sites Needing Further Evaluation VERSION DATE: 07/01/05 The NFE listing contains properties that the Department of Toxic Substance Control suspects with possible contamination. These are unconfirmed contaminated properties that need further assessment. PROC Listing of Certified Processors VERSION DATE: 02/05/16 Listing of Certified Processors that are operating under the state of California's Beverage Container Recycling Program. This list is maintained by the Department of Conservation. REF Referred to Another Local or State Agency VERSION DATE: 07/01/05 The REF listing contains properties where contamination has not been confirmed and which were determined as not requiring direct Department of Toxic Substance Control Site Mitigation Program action or oversight. Accordingly, these sites have been referred to another state or local regulatory agency. SCH School Property Evaluations VERSION DATE: 07/01/05 The SCH listing contains proposed and existing school sites that are being evaluated by Department of Toxic Substance Control for possible hazardous materials contamination. In some cases, these properties may be listed in the CalSites category depending on the level of threat to public health and safety or the environment they pose. SWIS Solid Waste Information System Sites VERSION DATE: 02/04/16 The Solid Waste Information System (SWIS) database includes information on solid waste facilities, operations, and disposal sites located in California. This database is maintained by the California Department of Resources Recycling and Recovery. 232 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA) SWRCY Recycling Centers VERSION DATE: 02/04/16 Listing of Certified Recycling Centers that are operating under the state of California's Beverage Container Recycling Program. This list is maintained by the Department of Conservation. VCP Voluntary Cleanup Program VERSION DATE: 09/14/04 The California Voluntary Cleanup program provides regulatory oversight by the Department of Toxic Substance Control (DTSC) to project proponents desiring to address mitigation activities at sites which have lower health and/or environmental risk than sites which are currently being addressed by DTSC. Refer to Envirostor database as source of current data. WMUDS Waste Management Unit Database VERSION DATE: 01/01/00 The Waste Management Unit Database System tracks and inventories waste management units. CCR Title 27 contains criteria stating that Waste Management Units are classified according to their ability to contain wastes. Containment shall be determined by geology, hydrology, topography, climatology, and other factors relating to the ability of the Unit to protect water quality. Water Code Section 13273.1 requires that operators submit a water quality solid waste assessment test (SWAT) report to address leak status. The WMUDS was last updated by the State Water Resources control board in 2000. ENVIROSTOR EnviroStor Cleanup Sites VERSION DATE: 02/05/16 The Department of Toxic Substances Control (DTSC) has developed the EnviroStor database system to evaluate and track sites with confirmed or potential contamination and sites where further investigation may be necessary. This EnviroStor database of cleanup sites contains the following: Federal Superfund sites (National Priorities List (NPL)); State Response, including Military Facilities and State Superfund; Voluntary Cleanup; and School sites. Sites where DTSC has made a "No Action Required" determination are not included in this database, as these sites had assessments that revealed no evidence of recognized environmental conditions in connection with the property. ENVIROSTORPCA EnviroStor Permitted and Corrective Action Sites VERSION DATE: 02/05/16 The Department of Toxic Substances Control (DTSC) has developed the EnviroStor database system to evaluate and track sites with confirmed or potential contamination and sites where further investigation may be necessary. This EnviroStor database contains detailed information on hazardous waste permitted and corrective action facilities. Investigation and cleanup activities at hazardous waste facilities (either Resource Conservation 233 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA) and Recovery Act (RCRA) or State-only) that either were eligible for a permit or received a permit are called "corrective action." These facilities treated stored, disposed and/or transferred hazardous waste. TOXPITS Toxic Pits Cleanup Act Sites VERSION DATE: 07/01/95 Toxic Pits are sites with possible contamination of hazardous substances where cleanup is necessary. This listing is no longer updated by the State Water Resources Control Board. 234 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA) USTR09 Underground Storage Tanks On Tribal Lands VERSION DATE: 12/04/14 This database, provided by the United States Environmental Protection Agency (EPA), contains underground storage tanks on Tribal lands located in EPA Region 9. This region includes the following states: Arizona, California, Hawaii, Nevada, and the territories of Guam and American Samoa. LUSTR09 Leaking Underground Storage Tanks On Tribal Lands VERSION DATE: 12/04/14 This database, provided by the United States Environmental Protection Agency (EPA), contains leaking underground storage tanks on Tribal lands located in EPA Region 9. This region includes the following states: Arizona, California, Hawaii, Nevada, and the territories of Guam and American Samoa. ODINDIAN Open Dump Inventory on Tribal Lands VERSION DATE: 11/08/06 This Indian Health Service database contains information about facilities and sites on tribal lands where solid waste is disposed of, which are not sanitary landfills or hazardous waste disposal facilities, and which meet the criteria promulgated under section 4004 of the Solid Waste Disposal Act (42 U.S.C. 6944). INDIANRES Indian Reservations VERSION DATE: 01/01/00 The Department of Interior and Bureau of Indian Affairs maintains this database that includes American Indian Reservations, off-reservation trust lands, public domain allotments, Alaska Native Regional Corporations and Recognized State Reservations. 235 of 235 www.geo-search.com 888-396-0042 Order# 64660 Job# 140210 Target Property SummaryDatabase SummaryDatabase Radius SummaryLocated Sites SummaryElevation SummaryGeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Hazardous Waste Tanner Summary (HWTS)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Facility Registry System (FRSCA)Above Ground Storage Tanks (ABST)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09) Resource Conservation & Recovery Act - Generator Facilities (RCRAGR09)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Statewide Environmental Evaluation and Planning System (SWEEPS)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Underground Storage Tanks (USTCUPA)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)Statewide Environmental Evaluation and Planning System (SWEEPS)Statewide Environmental Evaluation and Planning System (SWEEPS)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Historical Underground Storage Tanks (HISTUST)Historical Underground Storage Tanks (HISTUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)CALSITES Database (CALSITES)Referred to Another Local or State Agency (REF)Superfund Enterprise Management System Archived Site Inventory (SEMSARCH)EnviroStor Cleanup Sites (ENVIROSTOR)GeoTracker Cleanup Sites (CLEANUPSITES)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)Cortese List (CORTESE)Leaking Underground Storage Tanks (LUST)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)GeoTracker Cleanup Sites (CLEANUPSITES)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)EnviroStor Cleanup Sites (ENVIROSTOR)Unlocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA)Environmental Records Definitions - TRIBAL APPENDIX H PHYSICAL SETTINGS MAPS GeoPlus Physical Setting Maps Satellite view Target Property: Phase I Environmental Site Assessment 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Prepared For: IRC Environmental Consulting LLC Order #: 64660 Job #: 140217 Project #: 3325 Date: 03/28/2016 0 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property Summary 1 FEMA Map 2 FEMA Report 3 NWI Map 4 NWI Report 5 SOIL Map 6 SOIL Report 7 GEOLOGY Map 8 GEOLOGY Report 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA ReportNWI ReportSOIL ReportGEOLOGY ReportTable of Contents The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer's interpretation of this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers And independent contractors cannot be held liable For actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA ReportNWI ReportSOIL ReportGEOLOGY ReportTable of ContentsDisclaimer Target Property Information Phase I Environmental Site Assessment 1323 Parsons Ave Campbell, California 95008 Coordinates Point (-121.94491, 37.268474) USGS Quadrangle San Jose West, CA Geographic Coverage Information County/Parish: Santa Clara (CA) ZipCode(s): Campbell CA: 95008 San Jose CA: 95124 Radon * Target property is located in Radon Zone 2. Zone 2 areas have a predicted average indoor radon screening level between 2 and 4 pCi/L (picocuries per liter). 1 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property Summary .2 Click here to access Satellite view 2 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA Map FEMA - Federal Emergency Management Agency The National Flood Hazard Layer (NFHL) data used in this report is derived from the Federal Emergency Management Agency. The NFHL dataset is a compilation of effective Flood Insurance Rate Map (FIRM) databases (a collection of the digital data that are used in GIS systems for creating new Flood Insurance Rate Maps) and Letters of Map Change (Letters of Map Amendment and Letters of Map Revision only) that create a seamless GIS data layer for United States and its territories. The NFHL is updated as new study or LOMC data becomes effective. Note: Currently, not all areas have modernized FIRM database data available. As a result, users may need to refer to the effective Flood Insurance Rate Map for effective flood hazard information. This data was provided by the Federal Emergency Management Agency’s Map Service Center in November of 2013. FEMA Flood Zone Definitions within Search Radius A Zone A Areas subject to inundation by the 1-percent-annual-chance flood event. Because detailed hydraulic analyses have not been performed, no Base Flood Elevations (BFEs) or flood depths are shown. D Zone D Unstudied areas where flood hazards are undetermined, but flooding is possible. X Zone X An area that is determined to be outside the 100 and 500 year floodplains. 3 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA Report .4 Click here to access Satellite view 4 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA ReportNWI Map NWI - National Wetlands Inventory The US NWI digital data bundle is a set of records of wetlands location and classification as defined by the U.S. Fish & Wildlife Service. This dataset is one of a series available in 7.5 minute by 7.5 minute blocks containing ground planimetric coordinates of wetlands point, line, and area features and wetlands attributes. When completed, the series will provide coverage for all of the contiguous United States, Hawaii, Alaska, and U.S. protectorates in the Pacific and Caribbean. The digital data as well as the hardcopy maps that were used as the source for the digital data are produced and distributed by the U.S. Fish & Wildlife Service's National Wetlands Inventory project. Currently, this data is only available in select counties throughout the United States. NWI Definitions within Search Radius L1UBKx SYSTEM: LACUSTRINE SUBSYSTEM: LIMNETIC CLASS: UNCONSOLIDATED BOTTOM WATER REGIME: ARTIFICIALLY FLOODED SPECIAL MODIFIER: EXCAVATED PUBHh SYSTEM: PALUSTRINE CLASS: UNCONSOLIDATED BOTTOM SPECIAL MODIFIER: DIKED/IMPOUNDED PUBKx SYSTEM: PALUSTRINE CLASS: UNCONSOLIDATED BOTTOM SPECIAL MODIFIER: EXCAVATED 5 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA ReportNWI Report .6 Click here to access Satellite view 6 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA ReportNWI ReportSoil Map Soil Surveys The soil data used in this report is obtained from the Natural Resources Conservation Service (NRCS). The NRCS is the primary federal agency that works with private landowners to help them conserve, maintain and improve their natural resources. The soil survey contains information that can be applied in managing farms and ranches; in selecting sites for roads, ponds, buildings and other structures; and in determining the suitability of tracts of land for farming, industry and recreation. This data is available in select counties throughout the United States. SOIL Code Definitions within Search Radius 130 URBAN LAND-STILL COMPLEX, 0 TO 2 PERCENT SLOPES 140 URBAN LAND-FLASKAN COMPLEX, 0 TO 2 PERCENT SLOPES 169 URBANLAND-ELDER COMPLEX, 0 TO 2 PERCENT SLOPES, PROTECTED 170 URBANLAND-LANDELSPARK COMPLEX, 0 TO 2 PERCENT SLOPES 171 ELDER FINE SANDY LOAM, 0 TO 2 PERCENT SLOPES, RARELY FLOODED 175 URBANLAND-BOTELLA COMPLEX, 0 TO 2 PERCENT SLOPES W WATER 7 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA ReportNWI ReportSOIL Report .8 Click here to access Satellite view 8 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA ReportNWI ReportSOIL ReportGeology Map US GEOLOGY THE GEOLOGY DATA USED IN THIS REPORT ORIGINATES FROM THE USGS. THE FIRST STAGE IN DEVELOPING STATE DATABASES FOR THE CONTERMINOUS UNITED STATES WAS TO ACQUIRE DIGITAL VERSIONS OF ALL EXISTING STATE GEOLOGIC MAPS. ALTHOUGH A SIGNIFICANT NUMBER OF DIGITAL STATE MAPS ALREADY EXISTED, A NUMBER OF STATES LACKED THEM. FOR THESE STATES NEW DIGITAL COMPILATIONS WERE PREPARED IN COOPERATION WITH STATE GEOLOGIC SURVEYS OR BY THE NSA (NATIONAL SURVEYS AND ANALYSIS) PROJECT. THESE NEW DIGITAL STATE GEOLOGIC MAPS AND DATABASES WERE CREATED BY DIGITIZING ALREADY EXISTING PRINTED MAPS, OR, IN A FEW CASES, BY MERGING EXISTING LARGER SCALE DIGITAL MAPS. GEOLOGY Definitions within Search Radius GEOLOGY SYMBOL: Q UNIT NAME: QUATERNARY ALLUVIUM AND MARINE DEPOSITS UNIT AGE: PLIOCENE TO HOLOCENE UNIT DESCRIPTION: ALLUVIUM, LAKE, PLAYA, AND TERRACE DEPOSITS; UNCONSOLIDATED AND SEMI-CONSOLIDATED. MOSTLY NONMARINE, BUT INCLUDES MARINE DEPOSITS NEAR THE COAST. ADDITIONAL UNIT INFORMATION: NOT REPORTED ROCKTYPE/S: ALLUVIUM; TERRACE; LAKE OR MARINE DEPOSIT (NON-GLACIAL) 9 of 9 www.geo-search.com 888-396-0042 Order# 64660 Job# 140217 Target Property SummaryFEMA ReportNWI ReportSOIL ReportGEOLOGY Report APPENDIX I WATER WELL REPORT GeoPlus Water Well Report Satellite view Target Property: Phase I Environmental Site Assessment 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Prepared For: IRC Environmental Consulting LLC Order #: 64660 Job #: 140214 Project #: 3325 Date: 03/28/2016 0 of 7 www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property Summary 1 Database Radius Summary 2 Waterwell Map 4 Environmental Records Definitions 6 www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property SummaryDatabase Radius SummaryLocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA)Table of Contents The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer's interpretation of this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers And independent contractors cannot be held liable For actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property SummaryDatabase Radius SummaryLocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA)Table of ContentsDisclaimer Target Property Information Phase I Environmental Site Assessment 1323 Parsons Ave Campbell, California 95008 Coordinates Point (-121.94491, 37.268474) USGS Quadrangle San Jose West, CA Geographic Coverage Information County/Parish: Santa Clara (CA) ZipCode(s): Campbell CA: 95008 San Jose CA: 95124 Radon * Target property is located in Radon Zone 2. Zone 2 areas have a predicted average indoor radon screening level between 2 and 4 pCi/L (picocuries per liter). 1 of 7 www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property Summary FEDERAL LISTING Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2) > 1 Mile Total NWIS 0.5000 0 0 0 0 NS NS 0 SUB-TOTAL 0 0 0 0 0 0 0 2 of 7 www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property SummaryDatabase Radius Summary STATE (CA) LISTING Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2) > 1 Mile Total DWRWELLS 0.5000 0 0 0 0 NS NS 0 SUB-TOTAL 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 NOTES: NS = NOT SEARCHED TP/AP = TARGET PROPERTY/ADJACENT PROPERTY 3 of 7 www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property SummaryDatabase Radius Summary .2 Click here to access Satellite view 4 of 7 www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property SummaryDatabase Radius SummaryWaterwell Map 5 of 7 www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property SummaryDatabase Radius SummaryLocated Sites Summary NWIS United States Geological Survey National Water Information System VERSION DATE: 05/14/15 This USGS National Water Information System database only includes groundwater wells. The USGS defines this well type as: A hole or shaft constructed in the earth intended to be used to locate, sample, or develop groundwater, oil, gas, or some other subsurface material. The diameter of a well is typically much smaller than the depth. Wells are also used to artificially recharge groundwater or to pressurize oil and gas production zones. Additional information about specific kinds of wells should be recorded under the secondary site types or the Use of Site field. Underground waste-disposal wells should be classified as waste-injection wells. 6 of 7 www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property SummaryDatabase Radius SummaryLocated Sites SummaryEnvironmental Records Definitions - FEDERAL DWRWELLS California Department of Water Resources Water Wells VERSION DATE: 02/12/16 The California Department of Water Resources (DWR) maintains this database of water wells, including California Statewide Groundwater Elevation Monitoring (CASGEM) program wells and Voluntary wells. In Late 2009 the State Legislature amended the Water Code with SBx7-6, which mandates a statewide groundwater elevation monitoring program to track seasonal and long-term trends in groundwater elevations in California's groundwater basins. To achieve that goal, the amendment requires collaboration between local monitoring entities and DWR to collect groundwater elevation data. In accordance with this amendment to the Water Code, DWR developed the CASGEM program. 7 of 7 www.geo-search.com 888-396-0042 Order# 64660 Job# 140214 Target Property SummaryDatabase Radius SummaryLocated Sites SummaryEnvironmental Records Definitions - FEDERALEnvironmental Records Definitions - STATE (CA) APPENDIX J OIL & GAS REPORT GeoPlus Oil & Gas Report Satellite view Target Property: Phase I Environmental Site Assessment 1323 Parsons Ave Campbell, Santa Clara County, California 95008 Prepared For: IRC Environmental Consulting LLC Order #: 64660 Job #: 140215 Project #: 3325 Date: 03/28/2016 0 of 5 www.geo-search.com 888-396-0042 Order# 64660 Job# 140215 Target Property Summary 1 Database Radius Summary 2 Oil & Gas Map 3 Environmental Records Definitions 5 www.geo-search.com 888-396-0042 Order# 64660 Job# 140215 Target Property SummaryDatabase Radius SummaryLocated Sites SummaryEnvironmental Records Definitions - STATE (CA)Table of Contents The information provided in this report was obtained from a variety of public sources. GeoSearch cannot ensure and makes no warranty or representation as to the accuracy, reliability, quality, errors occurring from data conversion or the customer's interpretation of this report. This report was made by GeoSearch for exclusive use by its clients only. Therefore, this report may not contain sufficient information for other purposes or parties. GeoSearch and its partners, employees, officers And independent contractors cannot be held liable For actual, incidental, consequential, special or exemplary damages suffered by a customer resulting directly or indirectly from any information provided by GeoSearch. www.geo-search.com 888-396-0042 Order# 64660 Job# 140215 Target Property SummaryDatabase Radius SummaryLocated Sites SummaryEnvironmental Records Definitions - STATE (CA)Table of ContentsDisclaimer Target Property Information Phase I Environmental Site Assessment 1323 Parsons Ave Campbell, California 95008 Coordinates Point (-121.94491, 37.268474) USGS Quadrangle San Jose West, CA Geographic Coverage Information County/Parish: Santa Clara (CA) ZipCode(s): Campbell CA: 95008 San Jose CA: 95124 Radon * Target property is located in Radon Zone 2. Zone 2 areas have a predicted average indoor radon screening level between 2 and 4 pCi/L (picocuries per liter). 1 of 5 www.geo-search.com 888-396-0042 Order# 64660 Job# 140215 Target Property Summary STATE (CA) LISTING Acronym Search Radius (miles) TP/AP (0 - 0.02) 1/8 Mile (> TP/AP) 1/4 Mile (> 1/8) 1/2 Mile (> 1/4) 1 Mile (> 1/2) > 1 Mile Total OG 0.5000 0 0 0 0 NS NS 0 SUB-TOTAL 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 NOTES: NS = NOT SEARCHED TP/AP = TARGET PROPERTY/ADJACENT PROPERTY 2 of 5 www.geo-search.com 888-396-0042 Order# 64660 Job# 140215 Target Property SummaryDatabase Radius Summary .2 Click here to access Satellite view 3 of 5 www.geo-search.com 888-396-0042 Order# 64660 Job# 140215 Target Property SummaryDatabase Radius SummaryOIL & GAS MAP 4 of 5 www.geo-search.com 888-396-0042 Order# 64660 Job# 140215 Target Property SummaryDatabase Radius SummaryLocated Sites Summary OG Oil and Gas VERSION DATE: 07/23/15 This oil, gas, and geothermal well information database is maintained by the California Department of Conservation’s Division of Oil, Gas, and Geothermal Resources. The database information may change without notice. The Department of Conservation makes no warranties, whether expressed or implied, as to the suitability of the product for any particular purpose. Any use of this information is at the user's own risk. 5 of 5 www.geo-search.com 888-396-0042 Order# 64660 Job# 140215 Target Property SummaryDatabase Radius SummaryLocated Sites SummaryEnvironmental Records Definitions - STATE (CA) APPENDIX K WEST VALLEY SANITATION DISTRICT From: Jorge Picado [mailto:JPicado@westvalleysan.org] Sent: Wednesday, April 06, 2016 3:12 PM To: Benjamin Berman Cc: Alan Kam; Patrick Salandro Subject: Sewer connection permit for 1323 Parsons Avenue, Campbell Mr. Benjamin Berman, Attached above is the PDF copy of the original sewer connection permit for 1323 Parsons Avenue, in Campbell. The current Assessor’s Parcel Number for this address is 414-37-008. County records indicate the house was built in 1950. The sewer connection permit was issued on February 28, 1958. Notice that the parcels had previously Assessor’s Parcel Number 413-23-003 The District does not know if this parcel was previously discharging into a septic system. Please call me or write me if you have questions. Jorge L. Picado Assistant Engineer West Valley Sanitation District 100 East Sunnyoaks Avenue Campbell, California 95008 Office (408) 385-3009; Mobile (408) 828-1949 EXHIBIT 3 AIR QUALITY REPORT Page 2-0 . Shakeri, The Ridgecrest Group Limitations The Cohen Group has prepared this report for the exclusive use of Ridgecrest Development, for this particular project. The work was performed within the limitations set forth in the Agreement as to the degree of care, amount of time and expense, and any other limitations contained in the Agreement. No other representation, warranty or guarantee, expressed or implied, is included or intended in this report. The findings of this investigation are believed to be an accurate assessment of the proposed project and to the best of our knowledge, the findings constitute a reasonable and accurate assessment of the proposed projects and likely conditions as a result of the project. The Cohen Group responses to the questions submitted by The City of Campbell Community Development Department are based upon our review of the Bay Area Air Quality 2010 Bay Area Air Quality Management District (BAAQMD) Clean Air Plan and the BAAQMD Community Air Risk Evaluation Program (CARE). Our comments are also based on information provided by Ridgecrest Development and our experience as Certified Industrial Hygienists and Environmental Health and Safety professionals. No air monitoring to determine airborne particulate or ozone levels was conducted at the planned project site. Calculations regarding potential air quality impact were conducted using air quality electronic modeling programs available from the BAAQMD. The Cohen Group has not visited the site. Planned Project Ridgecrest proposes to build four homes on the 32,000 square foot site at the current address of 1323 Parsons A venue. There is currently one residence on the site which is to be demolished and replaced by four homes. Parsons A venue is currently a residential street with standard residential street traffic. The project property is generally bound by residential properties to the north, west and south and a Jiffy Lube automotive facility to the east at the corner of Parsons A venue and Camden A venue. Further west and south there continues to be residential homes in the neighborhood. The proposed project property is located approximately 745 feet north of Highway 17 and has a frontage on Parsons A venue. The proposed project is approximately 40 feet east of Camden Avenue. Discussion I. Would the proposed project conflict with or obstruct implementation of the applicable air quality plan. Response: No significant impact. The primary goals of the 2010 Bay Area Clean Air Plan is to 1) Attain air quality standards; 2) Reduce population exposure and protecting public health in the Bay Area; and 3) Reduce Greenhouse Gas (GHG) emissions, Page 3-0. Shakeri, The Ridgecrest Group identified as carbon dioxide (C02), methane, N20 (nitrous oxide), hydrofluorocarbons, perfluorocarbons, and sulfur hexafluoride. Due to the limited scope of the project, the proposed building of adding 4 residences to a site currently containing one house would support the goals of the Clean Air Plan and would not adversely impact air quality or implementation of control measures implemented by the BAAQMD. 2. Would the proposed project violate any air quality standard or contribute substantially to an existing or projected air quality violation. Response: No significant impact. Construction activities associated with the proposed project are expected to occur from August 2016 to May 2017. Excavation will be conducted over approximately one month with construction beginning shortly thereafter. Approximately 12-18 inches of soil will be excavated over the 32,200 square foot site and likely reused on site. Construction of the 4 residences including pouring of concrete foundations will occur shortly after excavation. Minimal diesel powered equipment will be used during the grading and underground work (electrical, plumbing, landscaping) the use of a single backhoe, sheeps foot compactor, excavator and bobcat excavator. Because of the construction time frame, overlapping of building phases, and the normal day-to-day variability in construction activities, it is not possible to quantify the daily emissions associated with each phase of the proposed construction activities. Project construction would potentially only generate short-term emissions of air pollutants. The emissions generated from the construction activities include: • Dust (including PM10 and PM2.s) primarily form "fugitive" emission sources such as material handling and travel on unpaved surfaces; and • Construction emissions of criteria air pollutants (Nitrous oxides, Carbon monoxide, PM10, and PM2.s) primarily from operation of construction equipment as referenced above (primarily diesel-operated). It is anticipated that due to the small scale of the project, all construction-related emissions would be below the BAAQMD significance threshold levels. However, the construction contractor will reduce construction-related air pollutant emissions by implementing basic fugitive dust control and exhaust emission measures including: • During active excavation all exposed surfaces will be watered at least one time per day. • All haul trucks transporting soil or other loose material shall be covered. • Idling times on equipment will be minimized by either shutting equipment off when not in use or reducing the maximum idling time to 5 minutes (as required by the California airborne taxies control measured Title 13, Section 2485 of California Code of Regulations). Page 4-0. Shakeri, The Ridgecrest Group • Construction equipment will be maintained and properly tuned in accordance with manufacturer's specifications. As follows is the estimated short-term construction emissions that may be associated with the proposed project and comparisons of those emissions to the BAAQMD's significance thresholds for construction emission. The CalEEMod (California Emissions Estimator Model, Version 2013.2.2) was used to estimate construction-related emissions. Due to the small scale ofthis project, defaults for Santa Clara County were used. Therefore, it is anticipated that the model provides "worst case" emissions. Estimated Construction Emissions (tons per year) ROG Construction 0.4 Significance Threshold 10 (BAAQMD)* N/ A =Not Applicable ROG = Reactive Organic Gases NOx =Nitrous oxides NOx PM10 PM2.s 2.2 0.20 0.16 10 15 10 PM 10 = respirable particulate matter with an aerodynamic resistance diameter of 1 0 micrometers or less PM25 =fine particulate matter with an aerodynamic resistance diameter of2.5 micrometers or less CO = carbon monoxide co 1.6 N/A *source-Bay Area Quality Management District CEQA Guidelines Updated May 2011 Estimated Yearly Project Operational Emissions (tons per year Category ROG Area 0.058 Energy 0.00076 Mobile 0.02 Significance Threshold 10 (BAAQMD)* N/A =Not Applicable ROG = Reactive Organic Gases NOx =Nitrous oxides NOx PMIO PM2.s 0.00079 0.0054 0.0054 0.0065 0.00053 0.00053 0.046 0.0322 0.009 10 15 10 PM 10 = respirable particulate matter with an aerodynamic resistance diameter of 10 micrometers or less PM2_5 =fine particulate matter with an aerodynamic resistance diameter of 2.5 micrometers or less CO = carbon monoxide co 0.661 0.0028 0.2099 N/A *source-Bay Area Quality Management District CEQA Guidelines Updated May 2011 Page 5-0. Shakeri, The Ridgecrest Group 3. Will the project result in a cumulatively considerable net increase of any criteria pollutant for which the project region is non-attainment under an applicable federal or state ambient air quality standard. Response: No Significant Impact. The air quality impacts as shown above would not result in substantial impacts or a substantial increase resulting in a net increase of any criteria pollutant. 4. Will the project expose sensitive receptors to substantial concentrations of toxic air contaminants (TAC)? Air pollutant emissions are generated by stationary and mobile sources. Stationary sources include point sources and area sources. Point sources are usually subject to a permit to operate from the BAAQMD and occur at specific identified locations and are usually associated with manufacturing and industry. Area sources are widely distributed and typically produce small emissions and they do not require permits to operate from the BAAQMD. According to BAAQMD CEQA Air Quality Guidelines and Air Taxies New Source Review Program Health Risk Screening Analysis Guidelines, health effects form carcinogenic air toxics are usually described in terms of individual cancer risk. Individual cancer risk is the likelihood that a person exposed to concentrations ofT ACs over a 70-year lifetime will contract cancer. The following shows the cumulative cancer risk index and PM2.5 impacting the proposed residences from BAAQMD-permitted stationary sources and major roadways within 1,000 feet of the proposed project. For the purposes of the calculation we used a distance of745 feet from Highway 17 at Camden Avenue to proposed residents assuming 149,000 average daily vehicle traffic (based on BAAQMD data). Calculations are derived from Bay Area Air Quality Management District's Roadway Screening Analysis Calculator which provides screening level PM2.5 annual average concentrations and the cancer risk. This modeling guideline is based on standard procedures developed by the California Office of Environmental Health Hazard Assessment (OEHHA) for toxicity values and age sensitivity, and are consistent with the most current risk assessment methodology and toxicity factors used in the District's Regulation 2, Rule 5: New Source Review of Toxic Air Contaminant. Calculations are based on the assumption that residents are experiencing outdoor concentrations for the entire exposure period. The cumulative cancer risk is well below the BAAQMD cumulative cancer threshold risk of 100 per million for new residential receptors. Thus the proposed project would be a less than significant health impact on proposed receptors. No known BAAQMD permitted stationary emission sources other than possible automotive service facilities were determined within V4 mile of the proposed residences and should provide no significant sources of toxic air contaminants to the proposed residences. Page 6-0 . Shakeri, The Ridgecrest Group According to the California Air Resources Board, most PM2.5 is derived from combustion, such as use of gasoline and diesel fuels by motor vehicles, burning of natural gas to generate electricity, and wood burning. PM2.s is the size of ambient particulate matter air pollution most associated with adverse health effects of the air pollutants that have ambient air quality standards. These health effects include cardiovascular and respiratory hospitalizations, and premature death. As a California statewide average, DPM (as diesel particulate matter, including gasoline, etc.) comprises about 8% ofPM2.5 in outdoor air, although DPM levels vary regionally due to the non-uniform distribution of sources throughout the state. Adverse chronic health impacts unrelated to cancer are measured against a hazard impact index which is defined as the particulate matter impact to a reference exposure levels as determined by OEHHA. The chronic reference exposure level for particulate matter (as diesel particulate matter) is 5 ug/m3. Therefore assuming the PM 2.5 is 0.116 ug/m3, compared to the OEHHA reference exposure level the hazard impact index is 0.23. Thus, the health hazard impact from Highway 17 to the proposed residences is less than the BAAQMD threshold of 1 and therefore the proposed project would be a less than significant health impact on proposed receptors. Estimated Health Impacts for Proposed Receptors Source Cancer Risk Hazard Impact PM2.s (per million) _{u_g[m~_ Highway 1 7 at 5.80 0.23 0.116 Camden A venue Significance Threshold 10 1 0.8 (BAAQMD) Note: Proposed receptors refer to proposed residences to be constructed by the developer http://www.baaqmd.gov/plans-and-climate/california-environmental-quality-act-ceqa/ceqa-tools http://www.baaqmd.gov/~/media/Files/Engineering/Air%20Toxics%20Programs/hrsa_guidelines.ashx 5. Would the proposed project create objectionable odors affect a substantial amount of people? Response: No significant impact: Across Camden Avenue there is a small business center with a Day Spa, Dickey's Barbeque Pit and Liberty Tax Services. A Taco Bell is located southeast of this business area. Parsons A venue is a residential street and traffic volume is standard for a residential street. Other than automotive service stations and automotive repair stations within 1/4 mile there are no known sources likely to create objectionable odors. Generally, odor emissions are highly dispersive, especially in areas with average wind speeds. Therefore odor impacts associated with the location of the proposed project would be less than significant. EXHIBIT 4 TREE INVENTORY AND ASSESSMENT Saratoga Tree Service 13745 Skyline Blvd. Los Gatos, CA 95033 May 4, 2016 Omid Shakeri The Ridgecrest Group 2898 Joseph Ave. Campbell, CA Re: 1323 Parsons Ave. Campbell,CA A site inspection was performed today at the above address to help identify and evaluate the condition of the trees as well as determine the size of the trees. This property is a fairly large property in Campbell located near Camden Ave. There is currently a single residence home on this property. I identified and mapped the locating of 18 trees on this site. Most of these trees are fruit trees and none of the trees are very significant. I am using the map supplied to me by Mr. Shakeri. Trees were located on the map but some were left off. I added every tree of any significance. Also, I added the overhanging Avocado tree from the neighbors property. 1. Peach, small tree, damaged trunk. Multi-trunk tree with 3- 3 to 4" stems, fair condition. This tree is only about 8' high. 2. Lemon (Ponderosa), 6" diameter trunk, 8' tall, in good condition. 3. Avocado (neighbors tree). This tree overhangs the property and all efforts to protect the root system during construction needs to be understood. About 25' in height with an estimated trunk diameter of 20". This tree does show some limb damage but over all, the tree is in fairly good health. 4. Cherry (Bing). This is a very young tree. Trunk diameter 6" and about 8' tall. good health. 5. Cherry sp. (unknown cultivar) this is a grafted tree with tiny fruit. Trunk diameter 11" and a height of 22'. This tree is in good health with a canopy spread of about 18'. 6. Orange This is a small tree with an 8" diameter trunk and a heaight of about 12'. It is showing overall canopy decline but could be revived if cared for. Fair health. 7. European Olive This is a double trunk tree with a very poor one sided shape. It has a double trunk with stems measuring 8" and 6' diameter. Height is about 16 feet. Health of the tree is good. 8. Apple Sadly, this poor old tree is completely hollow and ready to fall apart. It has a trunk diameter of 12" and a height of 12'. foliage looks good but health is poor. 9. Choke Cherry This tree has a trunk diameter of 11" and a height of 14'. The tree is crowded by the olive and has a poor shape. Health of the tree is fair. 10. Privet This is a double trunk tree with stems measuring at 10" and 7". It is in good health. Commonly used as hedge plants this was likely a wild tree. 11. Apricot Trunk diameter 12" and a height of 12'. This tree has past trunk damage and some decay. Overall, the tree could survive. Health good. 12. Plum (wild) This multi trunked small tree has a primary trunk about 8" in diameter with many suckers. Fair health but poor shape. 13. Apricot 12" diameter trunk, about 8' tall. Fair health 14. Apricot 8" diameter and 11' tall. this tree has a decayed trunk, poor health. 15. Almond (?) Dead 16. Almond 12" diameter trunk, about 18' tall. This tree has many cracks in the limbs and is showing drought stress. Health is fair but will likely decline. 17. Black Walnut Multi trunk (5) 4" to 6" This is a re-sprout from an old stump. Tree is about 16 feet tall and health of the tree is fair. Re-Sprout trees generally don't make viable trees. 18. Black Walnut Double trunk tree, 6" and 5" diameter, height about 10 feet, fair health. Tree Protection Guidelines and Recommendations During the course of any construction project, the existing trees often become obstacles to work around. Because an existing tree is a valuable asset to the property and certain trees are generally protected by city and county ordinance, it becomes important to consider all the needs of the trees and work toward preservation. Below are some of the guidelines that are recognized in the industry as vital to protecting trees during a construction project. 1) Fencing around the trees in the development area using chain link type fencing, and steel stakes, out to the drip line of the canopy where possible. 2) Do not store materials under the canopy of the trees or compact the soil with vehicles, supplies or any heavy equipment. Do not wash out cement trucks near the root system of the trees. Do not expose the roots of the trees to any foreign materials or liquids such as paint, plaster or chemicals of any sort. Pay attention to trees downhill of potentially hazardous liquids running towards the root systems. 3) Trenching needs to avoid the root zone of trees that are to be preserved. If not possible to avoid the root zone, underground installation of utilities needs to tunnel under the root zone in a manner so as to not damage the roots. 4) Excavated soil must not be stored on the root zone of protected trees. 5) Pruning of the trees needs to be done in accordance with the standards set forth by the International Society of Arboriculture, (I.S.A.) Any work to be done on the trees should be done by a company with a Certified Arborist on staff to oversee the process and insure that correct cutting procedures will be carried out by tree workers. 6) Mulch should be put on the surface of the ground, out to the edge of the root zone to be protected. Mulch will help minimize moisture loss and help the trees to survive the changes that occur during a construction project. 7) Additional water should be added during dry periods at a rate that is consistent with the needs of the variety of tree, or trees, that are to be protected. 8) Future irrigation needs to be installed so as to not hit the trunks of the trees. 9) When dealing with existing species of tree (such as the Oaks), that need a reduced level of additional irrigation, care needs to be given to the new landscape plans. Lawns and high water landscapes should not be installed near Oaks. 10) When trenching or activities that will compromise the roots or structure of a tree, or trees, cannot be avoided, a Certified Arborist needs to be consulted to advise of the best approach for dealing with potential damage to the trees. Respectfully submitted, Blair Glenn I.S.A. Certified Arborist #654 EXHIBIT 5 WILL SERVE LETTERS CITY OF CAMPBELL Community Development Department DRAFT MITIGATION MONITORING AND REPORTING PROGRAM Mitigation Measure Monitoring Phase Enforcement Agency Monitoring Agency Action Indicating Compliance Verification of Compliance Initials Date Remarks Air Quality - AIR Mitigation Measure AIR-1: The project applicant shall ensure that construction plans include the BAAQMD Best Management Practices for fugitive dust control. The following will be required for all construction activities within the project area. These measures will reduce fugitive dust emissions primarily during soil movement, grading and demolition activities, but also during vehicle and equipment movement on unpaved project sites: a. Use dust-proof chutes for loading construction debris onto trucks. b. Water or cover stockpiles of debris, soil, and other materials that can be blown by the wind. c. Cover all trucks hauling soil, sand, and other loose materials or require all trucks to maintain at least two feet of freeboard. d. Sweep daily (with water sweepers) all paved access roads, parking areas, and staging areas at the construction site. e. Sweep streets daily (with water sweepers) if visible soil material is carried onto adjacent public streets, as directed by the City Engineer. f. Enclose, cover, water twice daily or, or apply (non-toxic) soil stabilizers to exposed stockpiles (dirt, sand, etc.). g. Install erosion control measures to prevent runoff from Site Preparation and Construction City of Campbell Public Works Department and Building Division Periodic Compliance Report Mitigation Measure Monitoring Phase Enforcement Agency Monitoring Agency Action Indicating Compliance Verification of Compliance Initials Date Remarks the project site. Cultural Resources – CUL Mitigation Measure CUL-1: If archaeological or paleontological resources are encountered during excavation or construction, construction personnel shall be instructed to immediately suspend all activity in the immediate vicinity of the suspected resources and the City and a licensed archeologist or paleontologist shall be contacted to evaluate the situation. A licensed archeologist or paleontologist shall be retained to inspect the discovery and make any necessary recommendations to evaluate the find under current CEQA guidelines prior to the submittal of a resource mitigation plan and monitoring program to the City for review and approval prior to the continuation of any on-site construction activity. Site Preparation and Construction City of Campbell Building Division Periodic Compliance Report Geology and Soils - GEO Mitigation Measure GEO-1: The applicant shall comply with the recommendations (Pages 12 through 14) in the Soil and Foundation Investigation of Proposed 4 Single Family Residences, dated April 29, 2016. Such recommendations shall be incorporated into the project’s final engineering design to minimize the damage from seismic shaking, unsuitable fill, and other geological deficiencies. The project shall use standard engineering techniques and conform to the requirements of the International Building Code to reduce the potential for seismic damage and risk to future occupants. Prior to Submittal of Building Permit, & Site Preparation and Construction City of Campbell Building Division Assessment Report by Qualified Contractor Mitigation Measure Monitoring Phase Enforcement Agency Monitoring Agency Action Indicating Compliance Verification of Compliance Initials Date Remarks Hazards and Hazardous Materials - HAZ Mitigation Measure HAZ-1: Prior to issuance of a demolition permit, a qualified contractor shall asses the property for presence of Lead-based paint (LBP) and Asbestos containing building materials (ACBM), and if present, prepare a plan, to the satisfaction of the Building Official, to properly manage and dispose of such materials. Prior to Issuance of Demolition Permit City of Campbell Building Division Assessment Report by Qualified Contractor Noise - NOI Mitigation Measure NOI-1: Mechanical ventilation (HVAC) shall be included in all residences constructed to allow occupants to close doors and windows as desired to achieve additional acoustic isolation. Further, the project building plans shall incorporate dual pane thermal windows and acoustically effective doors with a rated minimum Sound Transmission Class (STC) as recommended by the acoustical study. Mitigation Measure NOI-2: An acoustical study shall be prepared for the project which will study existing noise conditions, the project plans, and provide specific structural recommendations to comply with the noise exposure limits identified in the Campbell General Plan. The project building plans shall incorporate the recommendations as mitigation measures. Prior to Submittal of Building Permit City of Campbell Building Division Assessment Report by Qualified Contractor To: Site and Architectural Review Committee Date: July 26, 2016 From: Stephen Rose, Associate Planner Via: Paul Kermoyan, Community Development Director Subject: Parsons Avenue Subdivision File No(s).: Planned Development Permit (PLN2016-34) | Zone Change (PLN2016-35) | Vesting Tentative Subdivision Map (PLN2016-36) | Parking Exception (PLN2016-222) | Initial Study (PLN2016-37) Address: 1323 Parsons Avenue BACKGROUND On February 3, 2015 the applicant sought City Council authorization to proceed with a General Plan Amendment and associated Zoning Map Amendment to consider a change in General Plan Land Use designation from Low-Density Residential to Low-Medium Density Residential, and zoning from R-1-6 (Single Family Residential) to P-D (Planned Development). Upon due consideration, the City Council found that the change in density (which would have allowed nine-units) would be inconsistent with the Housing Element and disrupt the established boundary between Professional Office land uses to the north and east, and Single Family land uses to the south and west. Instead of granting authorization to proceed, the Council voted unanimously to reject the proposal, providing direction for the applicant to evaluate options which would comply with the existing Land Use Designation and better fit the area. Since that time the applicant has worked with staff to scale back the project, consistent with Council feedback. PROPOSAL The applicant is seeking approval of a Planned Development Permit to allow the construction of four new two- story single-family residences, a Zone Change to allow a zone district change from R-1-6 (Single Family Residential) to P-D (Planned Development), Vesting Tentative Subdivision Map to allow the creation of five lots (four developable) from a single parcel and Parking Exception Permit to allow uncovered parking spaces to be provided in lieu of required covered parking. As the project includes a Zone Change, it does not qualify as categorically exempt, necessitating the preparation of an Initial Study (PLN2016-37) which will be provided in advance of the Planning Commission meeting (tentatively scheduled for August 23, 2016). PROJECT SITE The project site is a 33,263 square-foot property located on the west side of Parsons Avenue, south of Camden Avenue, and north of Sharp Avenue in the R-1-6 (Single-Family Residential) Zoning District (reference Attachment 1 – Location Map). The site is currently developed with a 1,615 sq. ft. single-story single-family residence and 480 sq. ft. garage (reference Attachment 2 – Project Plan; Sheet A1.2). Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. MEMORANDUM Community Development Department Planning Division SARC Memorandum – July 26, 2016 Page 2 of 4 PLN2016-34 to 36 & PLN2016-222 ~ 1323 Parsons Avenue PROJECT DATA Zoning Designation: R-1-6 (Single-Family Residential) Proposed Zoning: P-D (Planned Development) General Plan Designation: Low-Density Residential (less than 3.5 units/gr. acre) Net Lot Area: 33,263 square-feet Building Height: 25 feet, 4-inches1 35 feet Maximum Allowed Building Wall Height: 20 feet2 (F.G. to Top of Plate) Floor Area Ratio (FAR): 37.2%3 45% Maximum Allowed Building (Lot) Coverage: 23% 40% Maximum Allowed Parking Space Requirements: 13 (8 covered; 5 uncovered4) 12 Minimum (10 covered; 2 uncovered) Use General Plan Zoning North Jiffy Lube & Convalescent Care5 Professional Office P-O (Professional Office) East Head to Toe Salon* & H&R Block (across Parsons Avenue) Professional Office P-O (Professional Office)) South Single-Family Residence Low Density Residential (Less than 6 Units/Gr. Acre) R-1-6 (Single-Family Residential) West Single Family Residence Low Density Residential (Less than 6 Units/Gr. Acre) R-1-6 (Single-Family Residential) DISCUSSION The purpose of the Site and Architectural Review Committee’s (SARC) review is to provide feedback on the site design, circulation, architectural materials, colors, and landscaping. In consideration of the applicant’s proposal, the SARC should also consider that the P-D Zoning District is intended to provide a degree of flexibility that is not available in other zoning districts so as to allow for a superior development, particularly related to the development’s design and provision of open space. To aid in achieving this goal, the Zoning Code provides a list of considerations that should be taken into account in review of this project (CMC 21.12.030.H). For ease of reference, pertinent sections of code have been provided in the applicable areas of discussion. Site Layout: The applicant’s proposal would subdivide the subject property into five lots, comprising four ‘developable’ single-family lots located along the west and northwest property lines, and a single ‘common lot’ which takes access from Parsons Avenue and would satisfy the majority of site access, guest parking6, C-3 (storm water management) and fire department turnaround requirements (reference Attachment 4 - Tentative Subdivision Map). As a small segment of Lot 2 (northeast corner; shown in red) is proposed with an ingress/egress easement (rather than simply being part of the common lot) a discussion point has been raised to determine if this area, where it overlaps the driveway, should be incorporated into the common lot instead. 1 The unit heights vary; Lot 1: 24 feet, 6-inches; Lot 2: 24 feet, 8-inches; Lot 3: 25 feet, 4-inches; Lot 4: 25 feet, 4-inches. 2 The side and rear building walls of all units measure 20-feet in height; the front of units, where gables occur, measure greater. 3 Based on total floor area of all units and net lot size of all lots; lot by lot analysis provided on Sheet A1.0 of the Project Plans. 4 While the applicant’s proposal exceeds the minimum number of required parking spaces, as the applicant’s proposal seeks to provide uncovered parking in lieu of covered parking, a parking exception is required. 5 Jiffy Lube & the Convalescent Care are non-conforming land uses in the Professional Office zoning district. 6 As small lot single-family homes, the units are required to provide 2½ covered, plus ½ space uncovered parking for guests. SARC Memorandum – July 26, 2016 Page 3 of 4 PLN2016-34 to 36 & PLN2016-222 ~ 1323 Parsons Avenue Figure 1 – Site Configuration & Ingress/Egress Area over Lot 2 As the property abuts commercial uses to the northeast (Jiffy Lube) and north (Convalescent Care), the SARC should also consider the interface between disparate commercial and single-family residential land uses in these areas. For discussion purposes, the three primary interfaces have been described and labeled in the following Figure as: 1) Entry Drive (blue), 2) Driveway & Side of Lot 4 (green), and 3) Rear of Lot 3 & 4 (red). Figure 2 – Commercial & Residential Primary Interfaces Figure 3 – Residential Elevations Abutting Commercial Properties Figure 3 – Existing Fencing Separating Uses 5-foot tall masonry wall with two foot wooden lattice behind Jiffy Lube (on left) 6-foot tall wood fence behind Convalescent Care (on right) As project plans do not include a proposal for enhanced landscaping or fencing/walls between the two uses in these areas, a discussion point has been raised to determine if additional trees, fencing or even revisions to the building elevations revisions at these key interface areas would be warranted. Ingress/Egress Area SARC Memorandum – July 26, 2016 Page 4 of 4 PLN2016-34 to 36 & PLN2016-222 ~ 1323 Parsons Avenue Architectural Design: The Planned Development zoning district, provides the following considerations relating to structure design and site layout (Sec. 21.12.030.H.5.c): 1. The general silhouette and mass, including location on the site, elevations, and relation to natural plant coverage, all in relationship to the surrounding neighborhood, 2. The exterior design in relation to adjoining structures in terms of area, bulk, height, openings, and breaks in the facade facing the street, and 3. The appropriateness and compatibility of the proposed uses in relation to the adjacent uses and the area as a whole. The applicant is proposing ‘Craftsman’ style units with prominent front entries, composition shingle hipped and gable roofs, board and batten and shingle siding, and articulated building walls throughout (but with an emphasis on the front facades). The proposed colors and materials are noted on each page of the building elevations and illustrated on the color and material board but can generally be described as an earth tone pallet with gray (Lot 1), beige (Lot 2 & Lot 4), and blue (Lot 3) primary building wall colors (reference Attachment 3 – Color Elevations). While the neighborhood is predominantly comprised of older and smaller one-story single family residences, the proposed unit design and architecture could be considered complementary and consistent with the established neighborhood. As the units are roughly 130-feet back from Parsons Avenue, a streetscape schematic was not required. Instead, staff requested the preparation of site ‘sections’ showing the silhouettes of Lot 1 and Lot 2 building walls, demonstrating the relationship of the project to the property line and offsite development. The silhouettes, which may be found on Page A1.3 of the Project Plans (reference Attachment 2), demonstrate that the site configuration (including the placement of second-story mass and bulk) would be complementary with adjacent development and the area as a whole. Parking Modification Permit: Pursuant to Section 21.28.040 (Table 3) of the Campbell Municipal Code (CMC), small lot single-family dwellings are required to provide 2½ covered parking spaces per unit plus ½ space designated for guest parking per unit. The proposed four units will create a parking requirement of 10 covered parking spaces with two additional uncovered parking spaces for a total of 12 required parking spaces. As proposed, the project provides 12 parking spaces (8 covered and 4 uncovered spaces) as summarized in the table as follows: Covered Parking Uncovered Parking Total Required 10 2 12 Proposed 8 5 13 Difference -2 +3 +1 As such, the applicant is requesting a Parking Modification Permit to allow for the required covered parking spaces, to be provided as uncovered parking. Staff is supportive of the request in that the minimum number of parking spaces is still achieved (exceeded by one) and provided that the provision of uncovered parking, in-lieu of covered parking, results in a more functional shared use of space for the four units and a more consistent single-family residential look and feel than would be achieved by providing additional covered parking. Landscaping: The project will require compliance with the State mandated landscape water efficient guidelines, which will require incorporation of various water conservation measures, including planting of drought-resistant vegetation. Each lot would have over 1,000 square feet of useable open space (R-1-6 zoning district requires 750 square feet). SARC Memorandum – July 26, 2016 Page 5 of 4 PLN2016-34 to 36 & PLN2016-222 ~ 1323 Parsons Avenue Trees: The project site has 17 trees (none of which are considered protected), predominantly comprised of fruit trees and all but four are proposed for removal due to conflicts with proposed driveways or structures (reference Attachment 2 – Project Plans; Sheet A1.1 & Attachment 5 – Arborist Report). The trees to be retained include a European olive tree (#7), an apple tree (#8), an apricot tree (#11), and a plum tree (#12). Whereas the applicant has proposed to retain these four trees, staff would also recommend the removal of the apple tree (#8), as the Arborist Report indicates that the tree is in poor condition and ‘ready to fall apart’. Furthermore, as the applicant has not proposed any new trees with the proposed subdivision (deferring the decision to future property owners) a discussion point has been raised to determine if the provision of some new trees (such as two per lot) would be appropriate as a project requirement. OPTIONS The following options are intended to facilitate discussion of the project’s site and architectural review: • Should the area of Lot 2, which overlaps the driveway, simply be part of the common lot, rather than having access provided over an ingress/egress easement? • Should enhanced landscaping (e.g. Italian cypress, new trees) or replacement fencing (six-foot tall masonry or wood fence7) be required to be installed between the commercial and residential interface? Should any changes to the rear or side elevations of the homes which abut the commercial uses be required? • Should the apple tree (#8) which is noted as ‘ready to fall apart’ by the Arborist Report be removed? Should any trees marked for removal instead be retained? • Should additional trees be required as part of the project (such as two per lot?). If so, does the SARC have a preferred location for the provision of new trees? After discussion the SARC may recommend approval to the Planning Commission as proposed, or subject to specific revisions. Attachments: 1. Location Map 2. Project Plans 3. Color Elevations 4. Tentative Subdivision Map 5. Arborist Report 7 CMC 21.18.120 – Screening and Buffering requires an opaque screen consisting of plant material and a solid masonry wall or wooden fence not less than six feet in height whenever a commercial or industrial development adjoins a residential zoning district. Attachment 1 Location Map Project Site ITEM NO. 1 CITY OF CAMPBELL ∙ PLANNING COMMISSION Staff Report ∙ August 23, 2016 PLN2016-34 (PD) PLN2016-35 (ZA) PLN2016-36 (TSM) PLN2016-37 (MND) PLN2016-222 (PMP) Public Hearing to consider the application of Omid Shakeri for a Planned Development Permit (PLN2016-34) for the approval of site configuration resulting in the development of four units, architectural design, and to create lots which do not have frontage on a public street, Tentative Subdivision Map (PLN2016-36) to create four single family lots and one commonly owned lot, Zoning Map Amendment (PLN2016- 35) to change the zoning from R-1-6 (Single-Family Residential) to P-D (Planned Development), and Parking Modification Permit (PLN2016- 222) to allow uncovered parking in lieu of covered on property located at 1323 Parsons Avenue. Staff is recommending that a Mitigated Negative Declaration (PLN2016-37) be adopted for this project. STAFF RECOMMENDATION That the Planning Commission take the following actions: 1. Adopt a Resolution, incorporating the attached findings, recommending that the City Council adopt a Mitigated Negative Declaration (PLN2016-37); 2. Adopt a Resolution, incorporating the attached findings, recommending that the City Council approve a Zoning Map Amendment (PLN2016-35) to change the zoning district designation from R-1-6 (Single-Family Residential) to P-D (Planned Development); 3. Adopt a Resolution, incorporating the attached findings, recommending that the City Council approve a Tentative Subdivision Map (PLN2016-36) to create four single family lots and one commonly owned lot; 4. Adopt a Resolution, incorporating the attached findings, recommending that the City Council approve a Planned Development Permit (PLN2016-34) for site configuration resulting in the development of four units, architectural design, and creation of lots which do not have frontage on a public street; and 5. Adopt a Resolution, incorporating the attached findings, recommending that the City Council approve a Parking Modification Permit (PLN2016-222) to allow uncovered parking in lieu of covered, subject to the attached Conditions of Approval. ENVIRONMENTAL DETERMINATION Development projects are subject to review under the California Environmental Quality Act (CEQA). The level of review required under CEQA is generally commensurate with the scale and complexity of the proposed development. Many projects (e.g., minor land divisions, single-family residences, change of use, etc.) are generally exempt from CEQA. Although small "infill" Staff Report ~ Planning Commission Meeting – August 23, 2016 Page 2 of 6 PLN2016-34 to 37 & 222 ~ 1323 Parsons Avenue developments may be found exempt under CEQA Guidelines, the project requires a Zoning Map Amendment which is not generally exempt under CEQA. Development proposals that are not exempt require preparation of an Initial Study that analyzes a project for various potential environmental impacts, including traffic, air and water pollution, greenhouse gas emissions, noise, and various community impacts. Based on the Initial Study analysis (reference Attachment 12), staff prepared a Draft Mitigated Negative Declaration finding that the proposed project will not have a significant effect on the environment with the incorporation of the Draft Mitigation Measures and therefore does not require the preparation of an Environmental Impact Report (EIR). Staff recommends that the Planning Commission adopt a resolution recommending that the City Council approve the Draft Mitigated Negative Declaration. As required by law, the Draft Mitigated Negative Declaration and Initial Study were filed with the County Clerk-Recorder’s Office for public review, noticed in the Campbell Express newspaper, and posted on the City’s website. The public is also invited to comment on the Draft Mitigated Negative Declaration in writing during the 20-day comment period (August 3rd through August 23rd) and in person at the Planning Commission public hearing (August 23, 2016) and City Council public hearing (anticipated September 6, 2016). Staff has not received any comments on the Draft Mitigated Negative Declaration at this time. PROJECT DATA Zoning Designation: R-1-6 (Single-Family Residential) Proposed Zoning: P-D (Planned Development) General Plan Designation: Low-Density Residential (less than 6 units/gr. acre) Proposed Density: 5 units/ gr. acre Existing/Proposed Required Net Lot Area: 33,263 square-feet N/A Gross Lot Area: 34,813 square-feet N/A Building Height: 25 feet, 4-inches1 35 feet Maximum Allowed Floor Area Ratio (FAR): 37.2%2 45% Maximum Allowed Building (Lot) Coverage: 23% 40% Maximum Allowed Parking Space Requirements: 13 (8 covered; 5 uncovered3) 12 (10 covered; 2 uncovered) Use General Plan Zoning North Jiffy Lube & Convalescent Care4 Professional Office P-O (Professional Office) East Head to Toe Salon & H&R Block (across Parsons Avenue) Professional Office P-O (Professional Office)) South Single-Family Residence Low Density Residential (Less than 6 Units/Gr. Acre) R-1-6 (Single-Family Residential) West Single Family Residence Low Density Residential (Less than 6 Units/Gr. Acre) R-1-6 (Single-Family Residential) 1 The unit heights vary; Lot 1: 24 feet, 6-inches; Lot 2: 24 feet, 8-inches; Lot 3: 25 feet, 4-inches; Lot 4: 25 feet, 4-inches. 2 Based on total floor area of all units and net lot size of all lots; lot by lot analysis provided on Sheet A1.0 of the Project Plans. 3 While the applicant’s proposal exceeds the minimum number of required parking spaces, as the applicant’s proposal seeks to provide uncovered parking in lieu of covered parking, a parking exception is required. 4 Jiffy Lube & the Convalescent Care are non-conforming land uses in the Professional Office zoning district. Staff Report ~ Planning Commission Meeting – August 23, 2016 Page 3 of 6 PLN2016-34 to 37 & 222 ~ 1323 Parsons Avenue DISCUSSION Applicant’s Proposal: The applicant is seeking approval of a Planned Development Permit to allow the construction of four new two-story single-family residences, a Zone Change to allow a zone district change from R-1-6 (Single Family Residential) to P-D (Planned Development), Vesting Tentative Subdivision Map to allow the creation of five lots (four developable) from a single parcel and Parking Exception Permit to allow uncovered parking spaces to be provided in lieu of required covered parking. As the project includes a Zone Change, an Initial Study and Mitigated Negative Declaration (PLN2016-37) was prepared. The applicant’s proposal requires review and approval by the City Council. Project Location: The project site is a 33,263 square-foot property located on the west side of Parsons Avenue, south of Camden Avenue, and north of Sharp Avenue in the R-1-6 (Single-Family Residential) Zoning District (reference Attachment 10 – Location Map). The site is currently developed with a 1,615 sq. ft. single-story single-family residence and 480 sq. ft. garage (reference Attachment 11 – Project Plans & Tentative Subdivision Map; Sheet A1.2). Single-family residential properties border the site to the south and west and commercial uses border the property to the north and east. ANALYSIS General Plan / Land Use: The Campbell General Plan represents the City’s long term vision for the community and is intended to guide decision-making regarding the City’s physical and economic growth. In this regard, the General Plan provides policies applicable to land use and development, and organizes the City into a framework of distinct land use designations (i.e., commercial, residential, industrial, etc.), as codified by the General Plan Land Use Map. The General Plan land use designation for the project site is Low Density Residential (less than 6 units/gr. acre). The proposed density is approximately 5 units per gross acre. The proposed project could be found consistent with the following General Plan Land Use Element Strategies: Policy LUT-3.1: Variety of Residential Densities: Provide land use categories for and maintenance of a variety of residential densities to offer existing and future residents of all income levels, age groups and special needs sufficient opportunities and choices for locating in Campbell. Strategy LUT-5.2a: Neighborhood Compatibility: Promote new residential development and substantial additions that are designed to maintain and support the existing character and development pattern of the surrounding neighborhood, especially in historic neighborhoods and neighborhoods with consistent design characteristics. Strategy LUT-9.3e: Building Materials: Encourage the use of long-lasting, high quality building materials on all buildings to ensure the long-term quality of the built environment. Strategy LUT-17.1b: Landscaping: Ensure that new developments provide new tree plantings, shrubs, greenery and other landscaping materials, and preserve existing trees and shrubs. Zoning District: The current zoning of the project site is R-1-6 (Single-Family Residential). The project requires a P-D (Planned Development) zoning designation because it creates lots which would not have frontage on a public street (access is provided over a common lot). The P-D zoning district allows for flexibility of site standards (lot coverage, floor area ratio, setbacks, Staff Report ~ Planning Commission Meeting – August 23, 2016 Page 4 of 6 PLN2016-34 to 37 & 222 ~ 1323 Parsons Avenue etc.) when consistent with site characteristics, particularly related to the development’s design and provision of open space. Development within the P-D Zoning District must also be consistent with the underlying General Plan Land Use designation as well as applicable General Plan goals, policies, and strategies. Generally, the City looks to the standards that would be permitted using the underlying General Plan land use designation, such as the R-1-6 zoning district, for guidance. The proposed floor area ratio and setbacks are consistent with the development standards of the R-1-6 (Residential Single-Family) zoning district (which is limited to 50% FAR, and requires a 5-foot or ½ building wall height setback requirement), with the exception that all but one of the lots are slightly smaller than 6,000 square feet (defined as ‘small-lot single-family’) and the interior second-story setback between Lot 2 and Lot 3 is 7-feet, 10 inches, where a ten-foot setback would be standard. The Planned Development zoning district is intended to allow for this flexibility to promote better site design, which is accomplished through a common lot. In forming its recommendation to the Council, the Planning Commission should consider if such flexibility is consistent with the intent of the P-D zoning district and appropriate for the site in consideration of the project surroundings and site layout, and unit design. Tentative Subdivision Map: The applicant is requesting approval of a Tentative Subdivision Map to subdivide the property into four residential lots ranging in size from 4,636 sq. ft. to 6,381 sq. ft. in area5, in addition to one 11,363 sq. ft. common lot. The common lot consists of a common access driveway, shared parking spaces, an area for a fire truck turnaround, and landscaping. Prior to recordation of the Final Map, the applicant shall be required to provide draft Covenants, Conditions and Restrictions (CC&R’s) which provide for the formation of a homeowner’s association to ensure the long-term maintenance of the common lot and continued architectural integrity of the project. Planned Development Permit: The site has been designed such that a single driveway serves all four homes, allowing for more open space. The detached single-family homes are proposed with unit sizes ranging from 3,038 sq. ft. to 3,180 square feet (inclusive of a 425 sq. ft. garage). Each of the units would have between 1,050 and 1500 sq. ft. of useable private open space, exceeding the 750 sq. ft. typically required for an R-1-6 property. For greater detail on the proposed site layout, architectural design, landscaping, and request to allow uncovered space in lieu of required covered parking, please refer to SARC Memo – July 26, 2016 (reference Attachment 13). Public Improvements: The project requires frontage improvements per Campbell Municipal Code Section 11.24.040. The applicant will be required to match the existing frontage improvements of the adjacent property. Public Outreach: The applicant provided copies of the architectural plans to abutting property owners, consistent with the City's application requirements to provide advanced notification to neighbors. No public comments have been received at this time. 5 The size of Lot 2 and the Common Lot are anticipated to change slightly as a result of a small portion of the driveway, provided over easement on Lot 2, being incorporated into the Common Lot. Staff Report ~ Planning Commission Meeting – August 23, 2016 Page 5 of 6 PLN2016-34 to 37 & 222 ~ 1323 Parsons Avenue Site and Architectural Review Committee: The Site and Architectural Review Committee (SARC) reviewed the design and configuration of the proposed project at its meeting of July 22, 2016. The Committee was supportive of the project with the recommended changes (applicant revisions/changes in response to recommended changes are noted in italics): • Consider incorporating the small sliver of driveway over Lot 2 into the Common Lot. The applicant has agreed to make the proposed change and a Condition of Approval has been incorporated as part of the Tentative Subdivision Map to reflect this requirement. • Consider providing at least two evergreen trees on each lot (with an emphasis on protected tree species such as redwood, oak, cedar or ash), and removing the dying apple tree (#8). The revised project plans show a proposal for two Crape Myrtle trees (one front, one at the rear) for each of the residential lots. A Condition of Approval on the Planned Development Permit further stipulates that two additional trees shall be planted on the common lot near the guest parking spaces. • Consider providing an amenity (e.g. patio area, tot-lot) in the common open space area between the guest parking stalls and Lot 1. The revised project plans show a paved area with a park bench and barbeque in the requested area. • Consider replacing the existing fencing and walls between the residential and offsite commercial uses with a six to eight foot high wooden or solid masonry wall with landscaping to serve as a more substantive buffer. A Condition of Approval has been included as part of the Planned Development Permit to reflect this requirement. • Consider relocating the larger second-story master bedroom window on the rear/west elevation of Unit 2 to the north/left elevation to minimize the potential for privacy impacts to offsite residential uses to the west (reference Attachment 11 - Project Plans & Tentative Subdivision Map; Sheet A2.2). The revised project plans reflect this request. Prepared by: Stephen Rose, Associate Planner Approved by: Paul Kermoyan, Community Development Director Staff Report ~ Planning Commission Meeting – August 23, 2016 Page 6 of 6 PLN2016-34 to 37 & 222 ~ 1323 Parsons Avenue Attachments: 1. Findings Recommending Adoption of File No. PLN2016-37 (Mitigated Negative Dec.) 2. Findings Recommending Approval of File No. PLN2015-35 (Zoning Map Amendment) 3. Conditions of Approval for File No. PLN2015-35 (Zoning Map Amendment) 4. Findings Recommending Approval of File No. PLN2015-36 (Tentative Subdivision Map) 5. Conditions of Approval for File No. PLN2015-36 (Tentative Subdivision Map) 6. Findings Recommending Approval of File No. PLN2015-34 (Planned Development Permit) 7. Conditions of Approval for File No. PLN2015-34 (Planned Development Permit) 8. Findings Recommending Approval of File No. PLN2016-222 (Parking Modification Permit) 9. Conditions of Approval for File No. PLN2016-222 (Parking Modification Permit) 10. Location Map 11. Revised Project Plans & Tentative Subdivision Map 12. Initial Study, Draft Mitigated Negative Declaration & MMRP 13. SARC Memo – July 26, 2016 August 19, 2016 Project No. 48-049 Mr. Omid Shakeri The Ridgecrest Group, LLC 2898 Joseph Avenue Suite C Campbell, CA 95008 Subject: Noise Assessment Study for the Planned 4-Lot Subdivision, 1323 Parsons Avenue, Campbell Dear Mr. Shakeri: This report presents the results of a noise assessment study for the planned 4-lot subdivision at 1323 Parsons Avenue in Campbell, as shown on the Site Plan, Ref. (a). The noise exposures at the site were evaluated against the standards of the City of Campbell Noise Element, Ref. (b). The analysis of the on-site sound level measurements indicates the existing noise environment is due primarily to traffic sources on Camden Avenue and operations at the adjacent Jiffy Lube facility. The results of the study indicate that exterior noise exposure excesses occur from Camden Avenue traffic and mitigation measures will be required. Noise from the Jiffy Lube is audible at the site and contributes a minor amount of noise to the overall noise environment. The impact of noise from the Jiffy Lube facility is not significant. The interior noise exposures will be in compliance with the standards. Mitigation measures for the interior living spaces will not be required. Sections I and II of this report contain a summary of our findings and recommendations, respectively. Subsequent sections contain the site, traffic and project descriptions, analyses and evaluations. Attached hereto are Appendices A, B, and C, which include the list of references, descriptions of the applicable standards, definitions of the terminology, descriptions of the acoustical instrumentation used for the field survey, general building shell controls, and the on-site measurement data and calculation tables. EDWARD L. PACK ASSOCIATES, INC. 1975 HAMILTON AVENUE Acoustical Consultants TEL: 408-371-1195 SUITE 26 FAX: 408-371-1196 SAN JOSE, CA 95125 www.packassociates.com - 2 - I. Summary of Findings The noise assessment results presented in the findings were evaluated against the standards of the City of Campbell Noise Element, which utilizes the Community Noise Equivalent Level (CNEL) descriptor. The CNEL is a 24-hour time weighted average noise exposure that penalizes noise created during the evening and nighttime periods, and is commonly used to describe community noise environments. The Noise Element standards specify an exterior limit of 60 dB CNEL for the rear yards of single-family housing impacted by traffic noise. An exterior noise exposure limit of 65 dB CNEL is specified for noise from stationary sources, such as those at the Jiffy Lube. A limit of 45 dB CNEL is specified for interior living spaces. The noise exposures shown below represent the noise environment for existing and planned site conditions, and include the noise reduction provided by the existing property line barriers. A. Exterior Noise Exposures  The existing exterior noise exposure at the most impacted side and rear yard closest to Camden Avenue, 75 ft. from the centerline, is 69 dB CNEL. Under future traffic conditions, the noise exposure is expected to increase to 70 dB CNEL. Thus, the noise exposures in the side and rear yards will be up to 10 dB in excess of the limit of the City of Campbell Noise Element standards.  The existing exterior noise exposures at the most impacted planned building setback from Camden Avenue, 97 ft. from the centerline, are 67 and 68 dB CNEL under existing and future traffic conditions, respectively. As shown above, exterior noise exposure excesses will occur at the side and rear yards of Lots 3 and 4. Mitigation measures will be required. The recommended measures are described in Section II. - 3 - B. Interior Noise Exposures  The interior noise exposures in the most noise impacted planned living spaces closest to Camden Avenue will be 42 and 43 dB CNEL, under existing and future traffic conditions, respectively. Thus, the noise exposures will be within the 45 dB CNEL limit of the City of Campbell Noise Element standards. Noise mitigation for the interior living spaces will not be required. II. Recommendations A. Exterior Noise Controls To achieve compliance with the 60 dB CNEL standard of the City of Campbell Noise Element, the following noise control barrier is recommended:  Construct a 7 to 9 ft. high acoustically-effective barrier along the rear yard lot lines of Lots 3 and 4 as shown on Figure 1 on page 4. The barrier behind Lot 3 may terminate 17 ft. from the west property line. To control flanking noise, continue the barrier along the east side of Lot 4 to terminate at the typical side gate location. The barrier heights are in reference to the nearest building pad elevation.  Consult with a structural engineer of qualified fencing contractor to determine if the existing barriers that are acoustically-effective can be modified to conform to the noise barrier requirements described herein. The existing wood fencing is not acoustically-effective. - 4 - - 5 - To achieve an acoustically-effective barrier, it must be constructed air-tight, i.e., without cracks, gaps or other openings, and must provide for long term durability. The barrier can be constructed of concrete, masonry, wood, stucco, metal, earth berm or a combination thereof, and must have a minimum surface weight of 2.5 lbs./sq. ft. If wood fencing is used, homogeneous sheet materials are preferable over conventional wood fencing as the latter has a tendency to warp and form openings with age. However, high quality air-tight tongue-and-groove, board and batten or shiplap construction can be used. All connections with posts or pilasters must be sealed air-tight. No openings are permitted between the upper barrier components and the ground. III. Site, Traffic Project Descriptions The planned development site is located at 1323 Parsons Avenue between Camden Avenue and Sharp Avenue in Campbell. The site is relatively flat and at-grade with the surrounding roadway and land uses. The site currently contains a single-family house. Surrounding land uses include single-family residential adjacent to the south and west, the Jiffy Lube facility adjacent to the east and a medical office center adjacent to the north. The on-site noise environment is controlled primarily by traffic sources on Camden Avenue, which carriers an existing Average Daily Traffic (ADT) volume of approximately 48,000 vehicles, as determined from computer modeling using the on-site noise measurement data and topographical information. The Jiffy Lube facility operates from 8:00 AM to 7:00 PM Monday through Friday, from 8:00 AM to 6:00 PM Saturday and from 9:00 AM TO 5:00 PM Sunday. The facility performs minor automobile repairs, including fluid and filter services, brake service, light bulb replacement, tire rotations and wiper blade replacement. Major mechanical service and machining are not performed at this facility. The planned project includes the construction of four two-story single-family homes. Ingress and egress to the development will be by way of a private driveway off of Parsons Avenue. - 6 - V. Analysis of the Noise Levels A. Existing Noise Levels To determine the existing noise environment at the site, continuous recordings of the sound levels were made at two locations. Location 1 was at the northerly corner of the site, 80 ft. from the centerline of Camden Avenue, at the planned rear yard of Lot 4. Location 2 was along the easterly property line behind the Jiffy Lube, 169 ft. from the centerline of Camden Avenue and 38 ft. from the rear façade of the Jiffy Lube. The measurement locations are shown on Figure 2 on page 7. The sound level measurements were made on August 8-9, 2016 and were recorded and processed for a continuous 24 hour period using Larson-Davis Model 812 Precision Integrating Sound Level Meters. The microphones were placed at a height of 8 ft. above the site to eliminate the noise shielding effect of the existing property line barrier. The meters yield, by direct read-out, a series of descriptors of the sound levels versus time, as described in Appendix B. The measured descriptors include the L1, L10, L50, and L90, i.e., those levels exceeded for 1%, 10%, 50%, and 90% of the time. Also measured were the maximum and minimum levels and the continuous equivalent-energy levels (Leq), which are used to calculate the CNEL. The results of the sound measurements are shown in Appendix C. The results of the measurements reveal that the Leq’s at measurement Location 1, 80 ft. from the centerline of Camden Avenue, ranged from 65.5 to 67.7 dBA during the daytime, from 64.5 to 67.0 dBA during the evening and from 54.6 to 65.8 dBA at night. . The Leq’s at measurement Location 2, 169 ft. from the centerline of Camden Avenue and 38 ft. from the rear façade of the Jiffy Lube, ranged from 58.3 to 61.4 dBA during the daytime, from 57.8 to 6.09 dBA during the evening and from 46.2 to 57.1 dBA at night. - 7 - FIGURE 2 – Noise Measurement Locations Traffic noise dissipates at the rate of 3-6 dB for each doubling of distance from the source to the receiver. Other locations on the site at greater distances from the roadway will have lower noise levels. Additional noise reduction will be provided by interposed buildings of the project. Vehicular traffic noise contains a wide spectrum of frequency components (from 100 to 10,000 Hz), which is associated with engine, tire, drive-train, exhaust and other sources. These frequency components are centered primarily in the 250 and 500 octave bands, and were used in determining the noise control measures recommended for this project. - 8 - B. Future Noise Levels Future traffic volume data for Camden Avenue were not available from the City of San Jose. We are estimating, for the purposes of this study, that the annual average traffic growth rate is 1% per year. Over the course of 20 years, this growth rate is equivalent to a 22% increase in the traffic volumes. Thus, the estimated existing traffic volume of 48,000 ADT is expected to increase to 58,560 vehicles ADT for year 2036. This increase in the traffic volume yields a 1 dB increase in the traffic noise levels. V. Evaluation of the Noise Exposures A. Exterior Noise Exposures To evaluate the on-site noise exposures against the City of Campbell standards the CNEL’s for the survey locations were calculated by decibel averaging of the Leq's as they apply to the daily time periods of the CNEL index. A 10 dB penalty was added to noise created at night to account for the increased human sensitivity to noise during nighttime hours and a 5 dB penalty was added to noise created during the evening hours. The CNEL is a 24-hour noise descriptor that uses the measured Leq values to calculate a 24- hour time-weighted average noise exposure. Adjustments were made to the measured traffic noise levels to account for the various setback distances from the measurement locations to the receptor locations using methods established by the Highway Research Board, Ref. (c). The formula used to calculate the CNEL is described in Appendix B. The results of the calculations indicate that the exterior noise exposures at measurement Location 1, 80 ft. from the centerline of Camden Avenue, is 69 dB CNEL. Under future traffic conditions, the noise exposure is expected to increase to 70 dB CNEL. At the minimum planned setback of the home on Lot 4 97 ft. from the centerline of Camden Avenue the noise exposures were calculated to be 67 and 68 dB CNEL at first and second floors under existing and future traffic conditions, respectively. - 9 - At measurement Location 2, 169 ft. from Camden Avenue and 38 ft. from the rear façade of the Jiffy Lube facility, the noise exposure was calculated to be 62 dB CNEL. The property line barrier behind the Jiffy Lube provided 5 dB of Camden Avenue traffic noise reduction. Noise from Jiffy Lube was not shielded. At this location, the shielded noise exposure from Camden Avenue traffic was calculated to be 61 dB CNEL. The unshielded noise exposure from Camden Avenue traffic was calculated to be 66 dB CNEL. The noise exposure from Jiffy Lube operations was calculated to be 52 dB CNEL. Of this 62 dB, 61 dB is due to Camden Avenue traffic (shielded by existing barrier) and 52 dB is due to Jiffy Lube operations (unshielded). Thus, the noise exposure generated by Jiffy Lube operations adds 1 dB to the noise exposures at ground floor elevations and 0 dB to upper floor elevations. The Jiffy Lube noise exposure is within the 65 dB CNEL limit of the City of Campbell Noise Element standards for stationary noise sources. B. Interior Noise Exposures To determine the interior noise exposures, a 25 dB reduction was applied to the exterior noise exposures at the building setbacks to represent the attenuation provided by a typical building shell under a closed window condition. The closed window condition assumes the installation of standard dual-pane, thermal insulating windows and glass doors. The closed window condition is used in this study as the Mechanical Code will require adequate mechanical ventilation that allows the residences to keep windows and door closed at all times for noise control, as desired. The interior noise exposure in the most impacted living spaces closest to Camden Avenue will be 42 and 43 dB CNEL under existing and future traffic conditions, respectively. Thus, the noise exposures will be within the 45 dB CNEL limit of the City of Campbell Noise Element standards. - 10 - As shown by the above evaluations, exterior noise exposure excesses occur at the site and mitigation measures will be required. The recommended mitigation measures are described in Section II. The interior noise exposures will be within the limits of the standards. Mitigation measures for the interior spaces will not be required. This report presents the results of a noise assessment study for the planned 4-lot subdivision at 1323 Parsons Avenue in Campbell. The study findings and recommendations for current conditions are based on field measurements and other data and are correct to the best of our knowledge. The future noise exposures are based on estimates made by Edward L. Pack Associates, Inc. However, significant changes in future traffic volumes, or changes motor vehicle technology, speed limits, noise regulations, or other future changes beyond our control may produce long-range noise results different from our estimates. If you have any questions or would like an elaboration on this report, please call me. Sincerely, EDWARD L. PACK ASSOC., INC. Jeffrey K. Pack President Attachments: Appendices A, B, and C APPENDIX A References: (a) Site Plan, 1323 Parsons Avenue, by Bassal Architecture, May 23, 2016 (b) City of Campbell General Plan, Conservation and Natural Resources Element (Noise), Chapter CNR-7, Adopted November 6, 2001 (c) Highway Research Board, “Highway Noise - A Design Guide for Highway Engineers”, Report 117, 1971 B-1 APPENDIX B Noise Standards, Terminology, Instrumentation and Building Shell Controls 1. Noise Standards A. City of Campbell Noise Element Standards The City of Campbell General Plan, adopted on November 8, 2001, contains a Conversation and Natural Resources Element which includes a chapter on noise. The “Noise Element” utilizes the Community Noise Equivalent Level (CNEL) to define acceptable noise exposures for various land uses. The Noise Element limits exterior noise exposures at new residential developments to 65 dB CNEL from stationary noise sources and to 60 dB CNEL from traffic-related noise sources. In addition, the Noise Element specifies that residential interiors are limited to 45 dB CNEL. The Noise Element specifies conformance to the California Building Code (Title 24) standard of 45 dB CNEL for multi-family residences and transient lodging. B-2 2. Terminology A. Statistical Noise Levels Due to the fluctuating character of urban traffic noise, statistical procedures are needed to provide an adequate description of the environment. A series of statistical descriptors have been developed which represent the noise levels exceeded a given percentage of the time. These descriptors are obtained by direct readout of the Sound Level Meters. Some of the statistical levels used to describe community noise are defined as follows: L1 - A noise level exceeded for 1% of the time. L10 - A noise level exceeded for 10% of the time, considered to be an "intrusive" level. L50 - The noise level exceeded 50% of the time representing the "mean" sound level. L90 - The noise level exceeded 90 % of the time, designated as a "background" noise level. Leq - The continuous equivalent-energy level is that level of a steady-state noise having the same sound energy as a given time-varying noise. The Leq represents the decibel level of the time-averaged value of sound energy or sound pressure squared and is used to calculate the DNL and CNEL. B-3 B. Community Noise Equivalent Level (CNEL) The CNEL is a measure of the cumulative noise exposure over a 24 hour period. The CNEL index divides the 24 hour day into three subperiods, i.e., the daytime (7:00 am to 7:00 pm), the evening period (7:00 pm to 10:00 pm), and the nighttime period (10:00 pm to 7:00 am). Also, weighting factors of 5 and 10 dBA are applied to the evening and nighttime periods, respectively, to account for the greater sensitivity of people to noise during those periods. The CNEL values are calculated from the measured Leq values in accordance with the following mathematical formula: CNEL = [[(10log10(10ΣLeq(7-7))) x 12] + [((10log10(10ΣLeq(7-10))))+5) x 3] +[((10log10(10ΣLeq(10-7))))+10) x 9]]/24 C. A-Weighted Sound Level The decibel measure of the sound level utilizing the "A" weighted network of a sound level meter is referred to as "dBA". The "A" weighting is the accepted standard weighting system used when noise is measured and recorded for the purpose of determining total noise levels and conducting statistical analyses of the environment so that the output correlates well with the response of the human ear. B-4 3. Instrumentation The on-site field measurement data were acquired by the use of one or more of the sound analyzer listed below. The instrumentation provides a direct readout of the L exceedance statistical levels including the equivalent-energy level (Leq). Input to the meters was provided by microphones extended to a height of 5 ft. above the ground. The “A” weighting network and the “Fast” response setting of the meters were used in conformance with the applicable standards. The Larson-Davis meters were factory modified to conform to the Type 1 performance standards of ANSI S1.4. All instrumentation was acoustically calibrated before and after field tests to assure accuracy. Bruel & Kjaer 2231 Precision Integrating Sound Level Meter Larson Davis LDL 812 Precision Integrating Sound Level Meter Larson Davis 2900 Real Time Analyzer Larson Davis 831 Precision Integrating Sound Level Meter B-5 4. Building Shell Controls The following additional precautionary measures are required to assure the greatest potential for exterior-to-interior noise attenuation by the recommended mitigation measures. These measures apply at those units where closed windows are required.  Unshielded entry doors having a direct or side orientation toward the primary noise source must be 1-5/8" or 1-3/4" thick, insulated metal or solid-core wood construction with effective weather seals around the full perimeter. Mail slots should not be used in these doors or in the wall of a living space, as a significant noise leakage can occur through them.  If any penetrations in the building shell are required for vents, piping, conduit, etc., sound leakage around these penetrations can be controlled by sealing all cracks and clearance spaces with a non- hardening caulking compound.  Ventilation openings shall not compromise the acoustical integrity of the building shell. APPENDIX C On-Site Noise Measurement Data and Calculation Tables CNEL CALCULATIONS CLIENT: THE RIDGECREST GROUP FILE:48-049 PROJECT: PARSONS AVE. SINGLE-FAMILY DATE:8/8/-9/2016 SOURCE: CAMDEN AVE., JIFFY LUBE LOCATION 1 Camden Ave.LOCATION 2 Camden Ave, Jiffy Lube Dist. To Source 80 ft. Dist. To Source 169 ft., 38 ft. TIME Leq 10^Leq/10 TIME Leq 10^Leq/10 7:00 AM 66.8 4786300.9 7:00 AM 58.3 676083.0 8:00 AM 67.5 5623413.3 8:00 AM 60.7 1174897.6 9:00 AM 67.7 5888436.6 9:00 AM 60.8 1202264.4 10:00 AM 66.5 4466835.9 10:00 AM 59.7 933254.3 11:00 AM 66.7 4677351.4 11:00 AM 60.8 1202264.4 12:00 PM 65.9 3890451.4 12:00 PM 59.2 831763.8 1:00 PM 66.2 4168693.8 1:00 PM 59.8 954992.6 2:00 PM 67.1 5128613.8 2:00 PM 60.4 1096478.2 3:00 PM 67.7 5888436.6 3:00 PM 61.4 1380384.3 4:00 PM 65.7 3715352.3 4:00 PM 60.1 1023293.0 5:00 PM 65.5 3548133.9 5:00 PM 60.6 1148153.6 6:00 PM 66.5 4466835.9 SUM=56248855.8 6:00 PM 60.9 1230268.8 SUM=12854097.9 7:00 PM 67.0 5011872.3 Ld=77.5 7:00 PM 60.0 1000000.0 Ld= 71.1 8:00 PM 65.9 3890451.4 8:00 PM 57.8 602559.6 9:00 PM 64.5 2818382.9 SUM=11720706.7 9:00 PM 56.3 426579.5 SUM=2029139.1 10:00 PM 63.5 2238721.1 Le=70.7 10:00 PM 54.3 269153.5 Le= 63.1 11:00 PM 60.8 1202264.4 11:00 PM 51.9 154881.7 12:00 AM 58.6 724436.0 12:00 AM 50.1 102329.3 1:00 AM 56.0 398107.2 1:00 AM 47.3 53703.2 2:00 AM 54.6 288403.2 2:00 AM 46.2 41686.9 3:00 AM 55.1 323593.7 3:00 AM 47.6 57544.0 4:00 AM 57.9 616595.0 4:00 AM 49.5 89125.1 5:00 AM 61.7 1479108.4 5:00 AM 52.9 194984.5 6:00 AM 65.8 3801894.0 SUM=11073122.9 6:00 AM 57.1 512861.4 SUM=1476269.5 Ln=70.4 Ln= 61.7 Daytime Level=77.5 Daytime Level=71.1 Evening Level=75.7 Evening Level=68.1 Nighttime Level=80.4 Nighttime Level=71.7 CNEL=69 CNEL=62 24-Hour Leq=65.2 24-Hour Leq=58.3