Loading...
Pre-Application - 2003September 16, 2003 Mr. John C. Miller 188 Sunnyside Avenue Campbell, CA 95008 Re: Preliminary Application Comments File No.: PRE2003-00045 188 Sunnyside A venue Dear Mr. Miller: Thank you for your submittal of a preliminary application for the construction of a new second residential dwelling unit located at 188 Sunnyside Avenue. The subject property is presently zoned P-D (Planned Development) and is designated as Low-Medium Density Residential (6-13 units per gross acre) on the City's General Plan Land Use Map. The construction of a new second residential dwelling unit would require the following application approval: Planned Development Permit In order to construct a new second residential dwelling unit, the project will require the approval of a Planned Development Permit. This will require consideration by the Planning Commission and City Council through a public hearing process. Planning Division fees associated with this application include the Planned Development Permit application fee, which is currently $235 and the Park In Lieu fee, which is currently $7,035. Fees from the other departments will be required for this project and each department should be contacted for the specific amounts. The Planning Division completed the review of your pre-application and has the following comments regarding your proposal: Site Design The site currently is developed with a two-story single-family residence and attached garage. The site plan indicates that you would like to add a new residence in the rear portion of the property. The development standards for the R-1-6 Zoning District should be followed when looking at the site design for this project. The side and rear setbacks should be the greater of five feet or half the height of the building wall adjacent to the property line. Please consult the enclosed handout for how wall height is calculated in determining setbacks as it appears that the minimum of five feet on the side yards will be too little. The lot coverage for the subject property should not exceed 40 percent and the floor area ratio should not exceed 0,55. 70 North First Street. Campbell, California 95008-1436 . TEL 408.866.2140 . FAX 408.866.8381 . TDD 408.866.2790 PRE2003-00045 - 188 Su.__.jside Avenue Page 2 of 2 Parking The proposed project will require a total of four parking spaces, a minimum of two covered and two uncovered. The minimum dimensions for each parking space is 10 feet by 20 feet. Open Space Single-family residences require a minimum of 750 square feet of open space per unit for recreational purposes. This area is typically not contained in the front yard setback area and can be occupied with patios, porches, playground equipment etc. Staff recommends that a greater amount of private open space be provided in the rear part of the proposed unit for the future tenants. Please also be aware that there is a minimum requirement for distance between buildings which is a distance equal to the taller of the two buildings. Your application was distributed to the Public Works Department, Building Division, Planning Division and the County Fire Department. In addition to the Planning . Division's comments contained in this letter, please find enclosed comments from the Building Division, County Fire Department and Public Works Department. Please note that these comments are meant to be preliminary. Conditions of approval from each department will be developed when the formal application is submitted. Thank you for the opportunity to review these plans. Please do not hesitate to contact me at (408) 866-2193 or via email at stephaniew@cityofcampbell,com to schedule a meeting to discuss these comments and the application process. Sincerely, ~ ÚJI'II~ Stephanie Willsey Planner I end: Planned Development Permit Application Calculating Wall Height Handout Building Division's Comments, 9/12/03 Public Works Department Comments, 9/12/03 Fire Department Comments, 9/15/03 cc: Geoff Bradley, Senior Planner CITY OF CAMPBELL BUILDING INSPECTION DMSION - COMMENTS TO THE DEVELOPMENT REVIEW COMMITTEE DRC: September 12, 2003 ADDRESS: 188 Sunnyside Ave, Project Application: PRE-2003-00045 RECOMMENDATION: Note: No building code issue has been reviewed at Development Review Committee; it will be reviewed in the Building Penn it process, Please be aware that building codes are changing constantly; plans submitted for building penn it shall comply with the code in effect at that time. Submit pennit application together with required documents to the Building Inspection Division to obtain a building penn it. No construction can be commenced without an appropriate building pennit, It is recommended that this item be forwarded to the Planning Commission for review, with the following conditions. TO THE SA TISF ACTION OF THE BUILDING DIVISION MANAGER/BUILDING OFFICIAL: 1. PERMITS REQUIRED: A building permit application shall be required for each proposed new structure. The building permit shall include ElectricallPlumbinglMechanical fees when such work is part of the permit. 2. CONSTRUCTION PLANS: The conditions of Approval shall be stated in full on the cover sheet of construction plans submitted for building permit. 3. SIZE OF PLANS: The minimum size of construction plans submitted for building permits shall be 24 in. X 36 in. 4. PLAN PREP ARA TION: This project requires plans prepared under the direction and oversight of a California licensed Engineer or Architect. Plans submitted for building permits shall be "wet stamped" and signed by the qualifying professional person. 5. SOILS REPORT: Two copies of a current soils report, prepared to the satisfaction ofthe Building Official, containing foundation and retaining wall design recommendations shall be submitted with the building permit application. This report shall be prepared by a licensed engineer specializing in soils mechanics. 6. SITE PLAN: Application for building permit shall include a competent site plan that identifies property and proposed structures with dimensions and elevations as appropriate. Site plan shall also include site drainage details. J:\Building ORC Comments\188sunnysideave.doc 7, FOUNDATION INSPECTIONS: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project building inspector upon foundation inspection. This certificate shall certify compliance with the recommendations as specified in the soils report and the building pad elevation and on-site retaining wall locations and elevations are prepared according to approved plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered civil engineer for the following items: a. pad elevation b. finish floor elevation (first floor) c. foundation comer locations 8. TITLE 24 ENERGY COMPLIANCE: California Title 24 Energy Compliance forms CF-IR and MF-IR shall be blue-lined on the construction plans. 8% X 11 calculations shall be submitted as well. 9. SPECIAL INSPECTIONS: When a special inspection is required by U.B.C. Section 1701, the architect or engineer of record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the building permits, in accordance with U.B.C Section 106.3.5. Please obtain City of Campbell, Special Inspection forms from the Building Inspection Division Counter. 10. The City of Campbell, standard Santa Clara Valley Non-point Source Pollution Control Program specification sheet shall be part of plan submittal. The specification sheet (size 24" X 36") is available at the Building Division service counter. 11. APPROV ALS REQUIRED: The project requires the following agency approval prior to issuance of the building permit: a. b. West Valley Sanitation District (378-2407) Santa Clara County Fire Department (378-4010) School District: i) Campbell Union School District (378-3405) ii) Campbell Union High School District (371-0960) iii) Moreland School District (379-1370) iv) Cambrian School District (377-2103) c. Note: To Determine your district, contact the offices identified above. Obtain the School District payment form from the City Building Division, after the Division has approved the building permit application, 12. P.G.& E.: Applicant is advised to contact Pacific Gas and Electric Company as early as possible in the approval process. Service installations, changes and/or relocations may require substantial scheduling time and can cause significant delays in the approval process. Applicant should also consult with P.G. and E. concerning utility easements, distribution pole locations and required conductor clearances. J:\Building ORC Comments\188sunnysideave.doc MEMORANDUM CITY OF CAMPBELL TO: Stephanie Willsey, Project Planner DA TE: 09/12/03 FROM: Ed Arango, Associate Enginee&/ DRC APPLICATION SUBJECT: Site Address: 188 Sunnyside Avenue For File No(s): PRE 2003-045 Project Description: New second residential dwelling unit Applicant: John C. Miller PUBLIC WORKS DEPARTMENT PRELIMINARY CONDITIONS OF APPROVAL 1. Preliminary Title Report: Prior to issuance of any grading or building permits for the site, the applicant shall provide a current Preliminary Title Report. 2. Public Service Easement and Sidewalk Easement: Prior to issuance of any grading or building permits for the site, the applicant shall grant a 10 foot Public Service and Sidewalk Easement on private property contiguous with the public right-of-way along the Sunnyside A venue frontage, The applicant shall cause all documents to be prepared by a registered civil engineer/land surveyor, as necessary, for the City's review and recordation. 3. Street Improvements: Prior to issuance of any grading or building permits for the site, the applicant shall execute a street improvement agreement, cause plans for public street improvements to be prepared by a registered civil engineer, pay various fees and deposits, post security and provide insurance necessary to obtain an encroachment permit for construction of the standard public street improvements, as required by the City Engineer. The fee for a non-utility encroachment permit application is currently $260.00. The plans shall include the following: a, Removal of existing curb, gutter, sidewalk, and driveway approach related to the driveway approach. b. Construction of new curb, gutter, sidewalk, and separated ADA compliant dri veway approach. c. Installation of street trees and irrigation at 40 feet on center. d. Construction of conforms to existing public and private improvements, as necessary , 4, Water Meter(s) and Sewer Cleanout(s): Proposed water meter(s) and sewer cleanout(s) shall be installed on private property behind the public right-of-way line. J:\LandDev\Conditions\Sunnyside 188 Pre.DOC Page 1 of 2 188 Sunnyside Avenue 5. Utilities: All new on-site utilities shall be installed underground per Section 20.36.150 of the Campbell Municipal Code for any new or remodeled buildings or additions. Applicant shall comply with all plan submittals, permitting, and fee requirements of the serving utility companIes. 6, Utility Coordination Plan: Prior to issuance of building permits for the site, the applicant shall submit a utility coordination plan and schedule for approval by the City Engineer for installation and/or abandonment of all utilities. Streets that have been resurfaced within the previous five years will require boring and jacking for all new utility installations. Applicant shall also prepare pavement restoration plans for approval by the City Engineer prior to any utility installation or abandonment. 7, Storm Drain Area Fee: Prior to issuance of any grading or building permits for the site, the applicant shall pay the required Storm Drain Area fee of $2,000.00 per net acre, which is $400,00. Rev. 09/03 J:\LandDev\Conditions\Sunnyside 188 Pre.DOC Page 2 of 2 FIRE DEPARTMENT SANTA CLARA COUNTY PLANREVIEWNUMBER 03 1998 BLDG PERMIT NUMBER 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 . (408) 378-9342 (fax) . www.sccfd.org CONTROL NUMBER ~---_._~--_.._----~.__.__._-- --.-.-.--..--..-----.----- --.-.---.. FILE NUMBER PRE2003-00045 DEVELOPMENT REVIEW COMMENTS CODE/SEC. I SHEET n REQUIREMENT Pre-application review for a proposed new 1,637 square foot secondary living unit on a residential property. UFC Appendix III-A 1 Review of this Developmental proposal is limited to acceptability of site access and water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall make application to, and receive from, the Building Department all applicable construction permits. 2 Required Fire Flow: The fire flow for this project is 1,000 gpm at 20 psi residual pressure. The required fire flow is available from area water mains and fire hydrant(s) which are spaced at the required spacing. 3 The site plan provided does not list the parcel dimensions. To establish travel distance for fire department response, an assessor's parcel map was used for the determination. It appears that the development of the parcel does not create a fire department access issue. No fire department conditions or requirements based upon this submittal. City PLANS SPECS NEW RMDL AS OCCUPANCY CONST.TYPE ApplicantName DATE PAGE CBL 0 0 0 0 0 DREAM HOME SOURCE 9j15/2003 ~OF~ SECJFLOOR AREA LOAD DESCRIPTION BY ---- --- -.. Residential Development SFR I ~;;TION Sunnyside Av Organized as the Santa Clara County Central Fire Protection District Serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and Saratoga Hokanson, Wayne NAME OF PROJECT RECE~V~D SEP 0 4 2003 CITY OF CAMPBELL PLANNING DEPT. dream home source Plan Specifications Plan #32357 3 bedrooms 2 baths 0 car none garage 40'0" wide x 32'0" deep Roof height: 22'6" Main roof pitch: 1 1/12 Exterior wall framing: 2x4 FoundationCs): Crawlspace, slab, basement main: 1040 bonus: 597 The country flavor of the nostalgic porch and charming interior create a won- derfully warm and welcoming home. It is also affordable and expandable. A wide archway opens joins the formal living room to the dramatic angled kitch- en and dining room. An island in the kitchen greatly simplifies your food prepa- ration efforts. A design option included with the blueprints of this home substitutes one main- floor bedroom for a greatly expanded master bedroom with an amenity-laden private bath. The second floor can be finished at any time; it provides for two bedrooms and a bath. Order online or call now to purchase your dream home plan! 1.800'447'0027 6600 SW 92nd Avenue, Suite 180, Portland, Oregon 97223