Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENC2014-00056
Print Form 1.CITY OF CAMPBELL ENCROACHMENT PERMIT Permit No 14 0 CJG 5(a DEPT.OF PUBLIC WORKS (for working within the public X-Ref.File 70 North First Street right-of-way) Application Date 3/ti/I Lf Campbell,CA 95008 Issued L..� I t Application Expiration Date liltf I-t Ph. (408)866-2150 APN (---O--Lk '13,l 7 CI Fx. (408)376-0958 Permit Expiration Date I / (5 APPLICATION-Application is hereby made for a Public Works Permit in accordance with Campbell Municipal Code,Section 11.04. (Application expires in six (6) months if the permit is not issued. Application Fee is non-refundable.) A. Work Address or Tract No.: 200 E Hacienda Ave Campbell,CA • Utility Trench Location: Hacienda Ave B. Nature of Work: PLACEMENT OF 1 LOW PROFILE ALP 4485 VRAD CABINET AND ASSOCIATED CONDUi C. Attach four(4)copies of an engineered plan showing the location and extent of the work,and four(4)copies of the preliminary Engineer's Estimate of work. The plans shall show the relation of the proposed work to existing surface and underground improvements. When approved by the City Engineer,said plan becomes a part of this permit. D. All work shall conform to the City of Campbell Standard Specifications and Details for Public Works Construction;the General Permit Conditions listed on the reverse side;and the Special Provisions for this permit,listed below. Failure to abide by these conditions and provisions may result in job shutdown and/or forfeiture of Faithful Performance Sureties and cash deposits. (See General Permit Conditions 1 and 2.) E. The Contractor must have this permit and approved plans at the site and must notify the Public Works Department at least two days before starting work. Notice must be given to Public Works at least 24 hours before restarting any work. Name of Applicant: MARLANA TELFER Telephone: 408-635-8879 Address: 870 N MC CARTHY BLVD MILPITAS 95035 E-Mail Address: MT2183@ATT.COM 24-HOUR EMERGENCY PHONE NUMBER: Is this work being done by the property owners at their own residence? r YES r NO The Applicant/Permittee hereby agrees by affixing their signature to this permit to hold the City of Campbell,its officers,agents,and employees free,safe and harmless from any claim or demand for damages resulting from the work covered by this permit. The Applicant/Permittee hereby acknowledges that they have read and understand both the front and back of this permit, and they will inform their contractor(s) of the information. Applicant is advised that upon issuance of this permit, property owner, or property owner's successors, shall be responsible for any and all damages arising out of the condition of any private improvements in the public right-of-way. Accepted: 3/11/2014 (sign) Date (Contractor) (Print Name) Date SPECIAL PROVISIONS: 1. Street shall not be open cut for underground installations. Minimum cuts may be allowed for connections or exploration holes. Such cuts may be specifically approved by the Inspector prior to cutting. 2. Pavement may be cut for underground installations and must be restored in accordance with the Standard Details Trench Restoration Method "A",unless otherwise approved by the Engineer. 3. Work to be staked by a licensed Land Surveyor or Civil Engineer and two(2)copies of the cut sheets sent to the Public Works Department before starting work. 4. Per Section 4216 of the Government Code this permit is not valid for excavations until Underground Service Alert(USA)has been notified and the inquiry identification number has been entered hereon. USA Phone: 1-800-227-2600. USA TICKET NO. 5. Prior to any work,the property owner shall execute an Agreement for Private Improvements in the Public Right-of-Way,which shall be recorded. 6. Public Notification Requirements: 7. SEE PUBLIC WORKS FEE SCHEDULE FOR CURRENT FEES AMOUNT RECEIPT NO. PERMIT APPLICATION FEE $ 31 1 PLAN CHECK DEPOSIT $ SECURITY FOR FAITHFUL PERFORMANCE/LABOR&MATERIALS $ CONSTRUCTION CASH DEPOSIT $ PLAN CHECK&INSPECTION FEE $ 54 EMERGENCY PERMIT FEE $ APPROVED FOR ISSUANCE For City Engineer Date Permit Expires 12 Months After Date of Issuance Insprehc4-, ' 317 13 pad) GENERAL PERMIT CONDITIONS 1. A Construction Cash Deposit is required. Charges will be made against this deposit if there is an emergency call-out,overtime inspection or when City ordered barricading is required. Any such costs in excess of the deposit will be billed to the Permittee. 2. A one-year maintenance period and surety are required. Such period will begin on date of written acceptance by the City. 3. Refund or the cash deposit balance and refund or cancellation of the Faithful Performance Surety will be initiated by the written acceptance of the work by the City. 4. Submit project schedule 10(ten)days prior to proposed start of work.Special provisions may be required for work within City facilities and downtown Campbell. 5. The Permittee must request in writing a final inspection and acceptance of the work upon completion. Acceptance by the City will be made in writing to the Permittee. 6. Maintain safe pedestrian and vehicular crossings and free access to private driveways,bus stops,fire hydrants,and water valves. 7. A Construction Traffic Control Plan and a Construction Schedule are required for all lane closures,detours,and street closures.This plan must be reviewed and approved prior to any lane closures. 8. A Construction Traffic Control Plan shall conform to the Caltrans Manual of Traffic Controls for Construction and Maintenance Work Zones,dated 1990,available at Caltrans.Traffic control equipment shall include Type II flashing arrow signs if required. 9. Replace as directed by the City Engineer any damaged or removed improvements in accordance with City Standards and Specifications at the sole expense of the Permittee. 10. Sawcut for all PCC or AC removals. All PCC removals shall be to the nearest scoremark and shall be doweled to existing improvements. 11. Prior approval of inspector is required for any work done after normal working hours,on weekends or holidays and may require reimbursement of inspection costs at the current overtime rate. 12. Adequate signing and barricading is required on the job site. Failure to provide such signing and barricading may result in the City's providing signing and barricades and charging the cost(including all labor and materials)against the cash deposit. 13. Compaction testing of subgrade,base rock,and asphalt concrete by Permittee is required unless otherwise stated by the City Engineer. 14. The Contractor or Permittee will have a supervisory representative available for contact on the project at all times during construction. Contractor or Permittee shall provide a phone number at which they can be contacted outside the hours of 8:00 a.m.to 4:00 p.m. 15. No storage of materials or equipment will be allowed near the edge of pavement,the traveled way,or within the shoulderline which would create a hazardous condition to the public. 16. This permit shall not be construed as authorization for excavation and grading on private property adjacent to the work or any other work for which a separate permit may be required,nor does it relieve the Permittee of any obligation to obtain any other permit required by law. 17. This permit does not release the Permittee from any liabilities contained in other agreements or contracts with the City and any other public agency. 18. This permit is not transferable. Work must be performed by the Permittee or his designated agent or contractor as specified thereon. 19. Call back(call out)due to emeregencies regarding this permit shall be at the current overtime rate with a three(3)hour minimum charge per occurrence. 20. Pursuant to Chapter 14.02 of the Campbell Municipal Code,applicant shall not cause to be discharged any material into the municipal storm drain system other than storm water. Applicant shall adhere to the BEST MANAGEMENT PRACTICES established by the Santa Clara Valley Urban Runoff Pollution Prevention Program. 21. If the public interest requires a modification of,or a departure from the plans and specifications,the City shall have the authority to require or approve any modification or departure and to specify the manner in which the same is to be made for City-owned or maintained facilities. 22. Permitttee must provide advance notification to all parties that may be affected by the permit activities. Notification shall be reviewed by the City prior to distribution and include dates of work and a contact name and phone number. Applicant shall be responsible for ensuring that all those providing services under the applicant are aware and understand all of the above conditions. 3/11/2014 Applicant Date: Contractor (Print Name) Date: J:\FORMS\Templates\Encroachment Permits\Encroachment Permit STATIC form2.pdf Rev.02/14 AT&T PROJECT LIGHTSPEED-SPECIAL PROVISIONS 1. AT&T shall provide the City of Campbell a current map indicating all SAI cabinet locations. 2. All proposed facilities shall be of consistent materials, fmish and color(except where otherwise agreed, existing cabinets will be painted to match paired Lightspeed cabinet). Pedestal numbering shall be consistent and as inconspicuous as possible.New Lightspeed cabinets shall have an anti-graffiti fmish. 3. Plans shall be accurately dimensioned,clearly showing the proposed location,size,and shape of all existing and proposed facilities,including all existing and proposed right-of-way lines and any existing or proposed easements. 4. Applicant shall submit photos of the proposed location both pre-construction and post construction(with proposed structure(s)and all related service pedestals,bollards,landscaping,screening,etc.shown). 5. Plans shall reflect that the following guidelines whenever possible.The proposed facilities should be: a. located outside of any future sidewalk area b. located outside and beyond the back of walk(existing or future)wherever possible,with a minimum clearance of 18"from the sidewalk c. in park strip locations(only considered if beyond the back of walk location is not feasible),located with a minimum clearance of 18"from the face of curb to any part of the facility(if bollards are proposed,bollards must be located a minimum of 18"from face of curb),and a minimum of 18"from existing sidewalk d. in sidewalk locations (only considered if beyond the back of walk locations are not feasible), located to accommodate the required ADA specifications,with no less than a 4' clear path around the proposed facilities and with a minimum clearance of 18"from the face of curb to any part of the proposed facility(including bollards) e. located 5'from any existing public improvements such as,trees(tree wells if applicable),light poles,sign poles,etc. f. located with adequate clearance from existing fire hydrants g. located with adequate line of sight clearances 6. All contractors working under the permit shall have a valid City business license. 7. Applicant shall obtain approval from other agencies(Caltrans,Santa Clara Valley Water District,VTA,etc.)as needed. 8. After the City has reviewed and conditionally approved each permit location, the applicant shall proceed with the public/property owner notification process as follows: a. Following the City's preliminary approval of a site,AT&T shall mail a preliminary notice to all property owners that are adjacent to,or abut,the proposed location,as well as to those across the street from the location. In some cases,the City may request notifications be sent to additional properties or parties. The preliminary notice, which shall be approved by the City prior to mailing, shall be mailed to the property owners, with a copy to the City, not less than four (4) weeks prior to anticipated construction date, and shall give the property owner a two (2) week period in which to respond with questions or concerns. Should the notified property owner have concerns regarding the location of the facilities, AT&T shall work with the property owner(s)toward a mutually acceptable location. b. AT&T shall provide a final notice to the property owners at least 48 hours before the commencement of the proposed construction. 9. Applicant shall ensure that all property owner notifications have been completed prior to construction. 10. AT&T agrees to maintain the facilities in an attractive and clean manner. AT&T will make commercially reasonable efforts to remove graffiti within 48 hours of notification that the facilities have been tagged. AT&T shall provide the City with contact information for graffiti removal. 11. The City of Campbell will bill AT&T if its contractor leaves any site in such a manner requiring City forces to mobilize and mediate an unsafe situation. 12. If and only to the extent required by State or federal law, should a public project arise that requires the relocation of existing facilities, the facilities shall be removed/relocated to accommodate the scope,alignment and schedule of the public project,in accordance with state or federal legal or regulatory requirements. 13. As required by State statues,and unless otherwise preempted by State or Federal Law,abandoned facilities shall be completely removed from the site and the site restored to its original condition. 14. The parties agree to fully reserve their rights as to the applicability and interpretations of California Public Utilities Code Section 7901 and other related local, state or federal laws, and the City reserves the right to contend that future permits will not be issued without AT&T obtaining a franchise or other agreement prior to providing video services,and AT&T reserves it's right to contend that City is required to issue the encroachment permits without first obtaining such franchise or agreement. Applicant shall be responsible for ensuring that all those providing services under the applicant are aware of and understand all of the above conditions. 3/13/2014 Date Contractor (Print Name) Date Rev.2/2/07 -.. .. .._—. O L 1 3/14 �J,/ ISSUE DATE ,. „...„,- -.,---z•47,.., ..7., ., ....-1,?r,•;;.,--r-.:.,:-.4i eat, i ` 1' � •,�. -PGE PRELIMINARY qtr FS Na. c Jig .. \ 4 '. ■� -[{• '7 r. I I AF -NO LATERAL BLOCKAGES �' ,, v I _.... - 111 \irerkr':.. - P •••.E1A - :SCA:NET .. - * _ ,S'.," - VIEW OF PROPOSED ALP-448S CABINET VIEW FROM PROPOSED ALP-448S CABINET LOOKING SOUTHWEST ACROSS E HACIENDA AVE. LOOKING NORTHEAST ACROSS E HACIENDA AVE. ". N' ... ."' •,... tit, WORK LOCATION 7 \ t >s DA#316801 j z � r• �� - -�• rya.. : u„n,... *libleitif , Consulting,LLC r.•Stan so Sant c a mw Law)EMw-aow/rw<(aw)ao-ooae 'w.. L P ..�.na,m.o.wr.,.anau.mme mum i _ GEOASO N.-10 y _� } A ... - EXCH. SNJSCAI2 `• .__ .._5 "" E HACIENDA AVE ENGR. ALLAN RG&ELGS TEL.IMSI 6.35-6689 ENGR ARC V0NDJW2310 SAI ADDRESS:200X E HACIENDA AVE CAMPBELL,CA 95008 VIEW OF PROPOSED ALP 448S CABINET TYPE OF CGN:T. PROJECT METERED VRAD ADDRESS:200 E HACIENDA AVE CAMPBELL,CA 95008 LOOKING WEST ALONG E HACIENDA AVE. OA#316801 RO/EST.NO. 1261841 DWG. 1 OF 1 P30. SIGN LEGEND REQUIREMENTSGTME ROAD BACKAL UnNFACTORD NCECONDMONWITH WHICH INCLUDES,BUT IS NOT LIHIIED To, PAVING,STRIPPING,MARKINGS,SIGNING,AND LOOP DETECTION.ALL PEARS SHALL BE IN ACCORDANCE WITH 3032 G.MUTCD. 2. THE Y RESERVES THE GHT TO FIC®®®8,<><>...<0, ( BE E6 HEY WONT R K-FIAND OR GN POSTEE ESF T HE PL CONTROL PEAKS IN E CONTR N AXD TO MAKE CHANGES AS FlELD CONDITIONS WAREUD DURING XON�WORK HOURS.STEEL PEAlE5 SHALL HAVE AN ASPHALT MMP OX ALL EDGES,SKURELv EPT NEPOE 3.SUPPORTEDTRENCHES CHES SO SHA WORT ROCK BACK-FILLED OR SIGN EL-RA D DURING PNON.WOATES K TIFYINGHOU..S E EL PLATS SHALL ME HAVE AN 24 HOUR RA.OEMERGENCYALL EDGES,E NUMBER.ALL DIRT,,DUST,AND DEBRIS SHALL BE REMOVED FROM THE STREET AT THE END OF EACH DAY AND AT THE END OF THE JOB.THE STREET SHALL Nao-2 :E rag NI- I�1 CM(M) III-1 III4,* 1 ADRYBLE NDInDNATALLnMEB MAT(M OO `� B. APPROVARLOFTH SPIATX BDOE70 E�SAF MSNORTWITCREATES.;II COX AtEN WILL BE SHUT DOWN BY THE AGENCY. _ S. A COPY OF ALL TMFFIC REQUIPEMENTS AND TMFFlC CONTROL PEARS ISSUED BY TIE AGENCY MUST BE KEPT OX THE JOB SITE. NNFRNE LNIFS YIOR[ (]JSfD AX OFFlCWL PERMn.CONTACT THE AGENCY FOR Ix FORMATION ON OBTAINING APERMR. NJ-B NIB- NN-11 NXS-1 NF) N11A 41-tA C21(CA) N21-! 7. ALLTMVEL LANES WILL TYPICALLY BE A MINIMUM OF 12 FEET WIDE,II FEET IF ADIKENT TO BIKE LANES,UNLESS OTJIERWISE SPKIFlUEIY APPROVED BY TIE AGENCY. $IIRYEY E3>sio ®, , ' FLASHING ARROW BS RDS AS SIGNS IRED BYIN ZONESHAL HE.ENCY. 4 1YDRKER5 ''11,^r" CREW E L. ' 9. WARNING(W)SERIES SIGNS USED IN WORK ZONES SHALL BE BLACK ON AN ORANGE BACKGROUND. TGIA(vJ 0A(CAN 021-1 - A31-6 -• R1-1 RI-2 RS-t NDr P/OME 10. CONES AND PYLONS SHALL THE HAVE YELLOW REFLECIORIZED SLEEVES WHEN PLACED ALONG E CENTERLINE AND WHITE REFLECT...ED SLEEVES ALONG HE T OUTSIDE SHOULDER. •7...7 . [ 1 O Q© I ® ® 11. IF PARING IS ALLOWED IN THE ADVANCE WORKING AREA,ADVANCE WARNING SIGNS SHALL BE MOUNTED ON HIGH LEVEL DEVICES. _ti(l1 _11L1 M-10 0A-S r.:4U w-Bo Ilk; - I At2 R0-1 2. THE CONTRACTOR SHALL POST TOW-AWAY/xO PAR..SIGNS SEVENTY-TWO(72)HOU.IN ADVANCE,WITH DAY OF WEEK,DATE,AND WORK HOURS Rn (FlFl PDV MR) MM9O R)- NOTED,AND SHALL BAG PARKING METERS(WH E.APPLICABLE). /`�� RAMP ROAD ...,re [DETOUR] tDETOUR CANE DO NOT 13. OPEN CUT WORK SHALL BE DONE IN_-PHASES. •J ® > CLOSED CLOSED nPN name ,, SJ(W CLOSED PASS MEM �_� RI1 F Rtl 3 Mi♦ Y R11 3 11. WORKERS SHALL WEAR HARD HATS AND ORANGE VESTS AT ALL TIMES. NI-B nW - - - W� 11 ILK %1](Gy 15 COUNTY TRANSIT DISTRICT oo Ho, HALL BE NOTIFIED(S)WORKING DAYS PRIOR TO ANY WORK THAT AFFKTS BUS STOPS. CAUTION DETOUR END f0 lit V :44sroF 16. CONSTRUCTION SIGNS SHALL NOT OBSTRUCT SIGHT VISIBILITY AT DRIVEWAYS. QIN(CA) M4-8 DETOUR N`Bx R R4-7 R4-B °B' LEGEND R'- 17.' "-',' TRACKS CONTRACTOR SHALL NOTIFY ALL LOCAL BUSINESS OWNERS/OCCUPANTS TWO DAYS IN ADVANCE PRIOR TO ANY CONSTRUCTION ADJACENT TO BUSINESSES.CALIECRJOB LOCATION WORK HOURS R8-8 -TABLE Ka 3013 WARNING Murm- -STOPPING SORT 2isiln WD OS O arnw�DF SPEED- E HACIENDA AVE. B WC',E -TABLE MIMOHADVANCE xIxG3IG5sPAaxG- 7:g. x T.PERLENG„CRMSUR FOR TM,TR.RY,IIAMIC°ONTRDL=oH1 FROM: RE TANS LENGTH BEGIN CROSS STREET END CROSS STREET NP'®v®x - WINCHESTER DELL AVE. v"" -� 33 40 ;� norm- BLVD. ,!.,,--;,,---',.r.- ..... 'R O05 M ORD ERxWI TAP EA PERMIT NO. j •..••••.. lmorffr I000 FEEr Imo rtET 355 495 0 .3s wM LI I��,�_�1" �� 60 570 .v em .o.,,..a< - Rs(FEED WORK TO BE DONE "^"" ' HTrsTweMTxe THRFe.vw vvez Ex�wxT.x.o F..Pxmx...o.cmxe..rc zaxy ex rs'N Nxnv..mwsA ws.eeR WHERE, _ _F6Ei IX S-(PFAET) esm.PEA LE TRENCHING ,, goy,, p I W I CITY O F: CAMPBELL �TEo IX NOW.WIUM OF NTIEAID�PATEDD�ATING aw AIOTr BMW Reda START DATE END DATE POST®RATED APPROACH TAPER LENGTH S•d 'of SIGN SPACING LIMIT SPEED0GSO TRAFFIC CONTROL PLAN JOB NUMBER E:NONE 4 30 MPH 30 MPH 60 Ff. 30 FT. 250 FT. SCALE:NONE DP 7 GENERAL RAND ACCEPTED BY: FlANS MAPPED BY: PERMIT WORK EXTENSIONS MUST BE OBTAINED FOR HOURSop OAANXESS,WOW CONES TO VERTICAL BARRICADES WMISTREAY BURN at sit BY THE END OF PERMIT DATE COTNOTHING R.c.e. ilICEIVoroAsNIA Fs11DATE DAVID LOWERYNAME rornFrlxG,anxGING,DR ADOPrWG xEw sPECDIGnovs celBl6o lKgarxr. pK1N76O-3OO.O285 THERrEEREOFGUIDA.."'`g EG RDODYEPKICCETR WCCCRNISSRNS. -- EPP,DALE BATE 03-14 •SEND NOTIFICATION TO THE dt&t FOLLOWING ADDRESSES: 1) 200 HACIENDA AVE: 2) 221 HACIENDA AVE 3) 1315 DELL AVE GRASS 221 E HACIENDA AVE. GRASS FENCE CONCRETE SW lrei" CONCRETE SW k Y,# Mi 4 r' II 7 -� NCONCRETE SW Y 0 7 CONCRETE SW \ iCSW n 5 GRASS III L CSW GRASS - ' - ® GRASS PLACE NEW CABINET ON A I RETAINING WALL / DC / p-6O E HACIENDA 1315 DELL AVE. AVE, PARKING LOT JOB#9268644 at&t March 11, 2014 Regarding Property at: 200 Hacienda Ave, Campbell, CA AT&T Job#: 9268644 (Dear Mr. and Mrs. Resident,) Or (Dear Resident,) This is to notify you that AT&T California is upgrading the telecommunications network in your neighborhood. The new network will be capable of delivering enhanced DSL, internet- based telephone service, as well as new video services. In order to bring this new technology to your neighborhood, it will be necessary to place an above-ground cabinet. The cabinet is shown on the attached drawing and will be placed according to applicable City guidelines. Although the cabinet will not be on your property, we are sending this information to you as a courtesy. The cabinet will be installed in the public right-of-way as indicated by the enclosed map. After the upgrade of our network is complete, your neighborhood will have the most advanced and reliable communication services available. We expect to be moving forward with construction in your neighborhood soon. For more information on these services,please visit our website at www.att.com. If you have concerns about the project or the placement of this cabinet, we encourage you to call our special hot line number 408-635-8963. We welcome the opportunity to discuss our plans with you. Sincerely, AT&T t�!♦� Proud Sponsor of PP-U.S.Olympic Te n. at&t March 13, 2014 AT&T Job#: 9268644 Regarding the Property: 3000 Winchester BLVD., Campbell, CA 95008 Cloud Stephen R(TE)& Stephen Ronald (TE) PO BOX 6078, Fresno, CA 93703 Dear Property Owners, This is to notify you that AT&T California is upgrading the telecommunications network in your neighborhood. The new network will be capable of delivering enhanced DSL, internet- based telephone service, as well as new video services. In order to bring this new technology to your neighborhood, it will be necessary to place an above-ground cabinet. The cabinet is shown on the attached drawing and will be placed according to applicable City guidelines. Although the cabinet will not be on your property, we are sending this information to you as a courtesy. The cabinet will be installed in the public right-of-way as indicated by the enclosed map. After the upgrade of our network is complete, your neighborhood will have the most advanced and reliable communication services available. We expect to be moving forward with construction in your neighborhood soon. For more information on these services, please visit our website at www.att.cont/shop/u-verse. If you have questions about our project we encourage you to call our special hot line number (408) 635-8963. We welcome the opportunity to discuss our plans with you. Sincerely, AT&T Reference# 9268644 LINE OF SIGHT COMMUNICATION WORKSHEET FIELDER: mt DATE MAILED: 3/13/2014 NOTIFIER: kw JOB#: 9268644 DA: 316801 PAGE: 1 of 2 CABINET/VRAD LOCATION: 200 E Hacienda Ave., Campbell, CA 95008 SAI LOCATION: 200X E Hacienda Ave., Campbell, CA 95008 PRIMARY ADDRESS: ADJACENT PROPERTY-WHERE THE VRAD WILL BE PLACED. (I.E. IN FRONT OF, SIDE OF, REAR OF, ETC.) (C-Certified, R-Regular) PDR LTR HSE APT BU PRIMARY ADDRESS: 200 E Hacienda Ave., Campbell, CA 95008 1 C X PRIMARY OWNER'S NAME: Hines Vaf No Cal Properties/ Hines Interests LTD Partnership MAILING ADDRESS: 101 California Street, #1000, San Francisco, CA 941 1 1 ADDRESS: 210 E Hacienda Ave., Campbell, CA 95008 2 C X OWNER'S NAME Hines Vaf No Cal Properties/ Hines Interests LTD Partnership MAILING ADDRESS: 101 California Street, #1000, San Francisco, CA 94111 ADDRESS: 1315 Dell Ave., Campbell, CA 95008 7 C X OWNER'S NAME: Hines Vaf No Cal Properties/Hines Interests LTD Partnership MAILING ADDRESS 101 California Street, #1000, San Francisco, CA 94111 ADDRESS: 221 E Hacienda Ave., Campbell, CA 95008 3 R X OWNER'S NAME: Silicon Valley Center For Sports MED LLC MAILING ADDRESS: 221 E Hacienda Ave., Campbell, CA 95008 ADDRESS: 251 E Hacienda Ave., Campbell, CA 95008 4 R X OWNER'S NAME: Hamm Anita R (TE) MAILING ADDRESS: 1627 Fruitwood Ct., San Jose, CA 95125 ADDRESS: 1261 Dell Ave., Campbell, CA 95008 5 R X OWNER'S NAME: Hacienda Investors/Cooper& CO MAILING ADDRESS: 718 University Ave., #217, Los Gatos, CA 95032 LINE OF SIGHT COMMUNICATION WORKSHEET FIELDER: mt DATE MAILED: 3/13/2014 NOTIFIER: kw JOB#: 9268644 DA: 316801 PAGE: 2 of 2 CABINET/VRAD LOCATION: 200 E Hacienda Ave., Campbell, CA 95008 SAI LOCATION: 200X E Hacienda Ave., Campbell, CA 95008 PRIMARY ADDRESS: ADJACENT PROPERTY-WHERE THE VRAD WILL BE PLACED. (I.E. IN FRONT OF, SIDE OF, REAR OF, ETC.) (C-Certified, R-Regular) PDR LTR HSE APT BU PRIMARY ADDRESS: 271 E Hacienda Ave., Campbell, CA 95008 6 R X PRIMARY OWNER'S NAME: Hamm Family LP MAILING ADDRESS: 271 E Hacienda Ave., Campbell, CA 95008 ADDRESS: 3000 Winchester BLVD., Campbell, CA 95008 8 R X OWNER'S NAME: Cloud Stephen R(TE) & Stephen Ronald (TE) MAILING ADDRESS: PO BOX 6078, Fresno, CA 93703 ADDRESS: OWNER'S NAME: MAILING ADDRESS ADDRESS: OWNER'S NAME: MAILING ADDRESS: ADDRESS: OWNER'S NAME: MAILING ADDRESS: ADDRESS: OWNER'S NAME: MAILING ADDRESS: f Y. �, ty dt&t s . gyp, ::!'4 ''• e. / *i•• ,:' ' —,a,' '" '. . -k -.'' ''. o�' yam,, �• A. ' //,I ' I illa4 .19411114D:.. .. ,_ 446. 4 - PROP,ED ALP 448S CA — VIEW OF PROPOSED ALP-448S CABINET VIEW FROM PROPOSED ALP-448S CABINET LOOKING SOUTHWEST ACROSS E HACIENDA AVE. LOOKING NORTHEAST ACROSS E HACIENDA AVE. , WORK LOCATION �_4' �-„� ^ i \ "°" w. y . I . r ''Is r... e v s` ..f' �p l oy E HACIENDA AVE 11 SAI ADDRESS:200X E HACIENDA AVE CAMPBELL.CA 95008 VIEW OF PROPOSED ALP-448S CABINET VRAD ADDRESS:200 E HACIENDA AVE CAMPBELL,CA 95008 LOOKING WEST ALONG E HACIENDA AVE. .JOB#9268644 DA#316801 LOCATION MAP ISSUE o,,, at&t oa-14 SAI IS+/-450'EAST OF THE C/L / OF WINCHESTER BLVD. ", 3o E HACIENDA AVE. • DO 8� �R0/0 WORK 210-1 020-2 In „ SIDEWALK IFIIII N 12' Q �o.e� -.--- 26' 14' -.. — 361 1-51 — 26' MAX //// rMAXZ 12'_ 20 / SIDEWALK I^ a SIIDEWALK LIMEN ROAD / 1 I WORK SHOULDER\ J SIDEWALK SIDEWALK I SD AHEAD WORK ��JJ CLOSED l CLOSED G20-2 R9-9 R9-9 W20-1 W21-5 - j I ESCORT PEDESTRIANS THROUGH WORK AREA. 25' -- - _-_---ENTRANCE/EXIT TECHNOLOGY PARK 6O -.--ti-25O--f1,---25O SHOULDER I I 5' - TAPER T.A.N.S. LEGEND Z: v yy .."s m IT ROWS ON+° N ® swum mess TYR OP CONSTRUCTION TINS W. _ _p-' TRENCHING TAW.RRMMNWNO",MNERa TRENCHING ®o.m.,,,. ,o,„u,„, 9268644 m► Me.....F WW. pwe,7 or 7 SCALE:NONE 4..0ISSUE DATE at&t 1 3/14 LEGEND MEASUREMENTS ARE TAKEN FROM THE INTERSECTION OF E HACIENDA AGE sN CABINET AND DELL AGE iffl VRADCABINEE 3 ED sue sox a 0 a ; 11 yE HJ �y I �i .-�; STREETUGHT $ EI S i p n B E Z „ E .4 (STATICAL ) a R _ B 8 a R A ® MONUMENT t i 1 t f i if f O FIRE HyDRAJrt a i V A JOINT POLE ® MANHOLE 221 E HACIENDA 1261 E HACIENDA v ROAD SIGN AVE. AVE • BOLLARD �— I POTHOLE NOW _ - FFAN'PI BF I CRASS GRASS• tea. 1EHCE TREE CONDEIE SW ' p CdIDEIE SW t ROW RIGHT OF WAY JI_TOO G FOCI FACE OF CURB 3 I BOC BACK OF CURB /�+I C 12FLI ADC Gr]DLa L [ I LOG ;T OF WALK j0————51CRN DRAIN——ASP—— — _-_ST_- —S� _ S L ppp BOW BACK OFWALX $ CA _____—__—__—__—__—__—__—__—__—__—__—________—_____—__—___ ___—�—I I'�I EOD EDGE OF DRIVEWAY 5———5— SEWER —— —__—6___ S S S— 5— 5— —--——--——— ——— _—— —— 1 WOO M N*6 A ICE M $ EOW EDGE of wAucwnr SW sDEwALx R IX K I.Y R m.O7C RR POOR \ \ !.w - I li PS PARKS/RP n 4:f :u'-- \N _ OW DRIVEWAY V roC "}Ty' T• COI \ I El C/L CENTERLINE EAETE SW 1p At \ COERCE SW / E=g UTILITIES 1 60Y /® ® 'I I IN —W— WATER GRASS CSW CRASS m I �-CRASS Q —T— TELEPHONE q6W— — \ _— —E—ELECTRIC / 4•Q Ryl 1110:1 —SS— wormy SEWER UMWA EATER OR Ill COMA SDI' sD we p OF/� /� 00 1-HI CO m p Oft \-:,...",,......... —SD—STORM DRAIN I G GAS I I I I I I I�J_� I I I al I� WV WATER VALVE GMg.0 H f i I g' b s i^ 6 Te " A 1 I WM WATER METER s = i i I $ '" 1-6 s A M ; ; .S i , DA 8316801 is8 A x x .. .. arro.OM••EUTIKKnHur . .1 200 E HACIENDA 6 1315 ORL AYE. AVE FARAD LOT GEO/CO NB-10 GENERAL CONSTRUCTION NOTES EXCH. SNJSCAI2 •EXTRA CAUTION SHOULD E TRIES MEN DICUBIG AND PLACING THE FAWURE5 FOR OTT CAMP..AS OTHER ENGR. ALVIN ROBIELOS TEL.HOB)8354889 UTILITIES MAY E N PROXMTY OF THE WRIT COCA'S.. ENGR MC Y01(0.1WSA10 •TUNNEL CORBS AND 0 A RADIUS AT&T TRUASSUMES NN RESPONINFORMATION HEREIN FOR PROVIDEHE D. THE Y OF THE CAUTION CALL TOLL FREE ALL BENDS MR E O A RApU5 OF N.UNLESS SUBSTRUCTURE INFORMATION HEREIN PROVgED.THE USER ASSUMES i g� •OTHERWISE NOTED. RESPONSIBLITY FOR VERIFYING SUBSTRUCTURE LOCATIONS BEFORE 48 HRS PRIOR TO DIGGING TYPE OF CONST. PROJECT •RESTORE AREA TO UNE OR BETTER CONDITION EXCAVATING AND ASSUMES ALL LIABILITY FOR DAMAGE TO TELEPHONE OTHER LIMB.THAT ARE NOT FOR ALL SUBSTRUCTURE SCALE 1•-20 L10HTSPEED •NORFTCI Tr OF CAI/ELLR6 HOURS BEFORE STARTING FACILITIES AS A RESULT OF SUCH EXCAVATION.CALL UNOERGROUND SHOWN MAY EAST IN WORK AREA LOCATIONS D TI? I. WORK OPERATIONS,ADHERE TO ALL SERVICE ALERT OHM(600)227.2500 TWO DAYS BEFORE DIGGING IN PERMIT ECUWEMENTS. PROXIMITYTOTELEPHONERANT. SWTTRUCTURION I EENOTGUARA T OF EED. 800-227-2600 or 811 D ROAST.No. 9268644 DWG, 2 OF 7 P501 IpN.CRVC-,� F oR CON bell , U° 0� � i\ Ge Qfi +C�mP �, c 4 • N • 0 or Ks l,errn1 ,, p,Ons put) l� vs/o ,rw� h°Y° „, . contract -in. 1.m.• ..��}} ISSUE DATE at&t 1 3114 DETAILED VIEW OF THE PROPOSED Right of Way Vertlicatlon ALP-448S VRAD CABINET 200E HACIENDA AVE,CAMPBELL APN:424-33.120 The franchise area/street right of way of e hacienda ave is 33 feet from center4ne,centerline to face of curb is 19 feet.the street T6.5033 right of way extends 14 feet from 0a face of curb �t�r, roc—f 3 © CONCRETE SW 'S o a 2ref—, / °�� Q }— t l� � .?''-0 0 Y —T DIRT il �_ — — �In, .i 1 L RT M v+ 36 a0" 109" I 110"-4] 8" 1 PL(N) GREEN ALP-448S O TRENCH FR(N)VRAD TO SN -6)EXISTING MEN SAl ON CONCRETE NOT TO SCALE CABINET W/SIDE MOUNTED PL(N) 19' 1- CPC 4C - PAD POWER METER 9257C FOR TE4'LCO DA 816801 ON CONCRETE PAD FOUNDATION SEE DWG 4 OF 7. @ REMJAE AND RDPUCE 60 SOFT OF 7>NEW SEE RE RETAINING OF 7 FOR DETAILS CONCRETE SIDEWAWALL LK PL(N) 72'X 14-4°CONCRETE RESTORE TO BETTER OR UKE CONDITION. GEaw N4-to PAD FOUNDATION FOR EXCH. SNJRGw52 CABINET PLACEMENT 5O NEW 1-30 PC FOR POWER ENDS. ALAINRoe,eLos TEl.tawst03seeea PM ON DWG j 2 OF 7 ENGR ARC V0NDM9M0 TYPE OF CONS, PROJECT U0IITDPEED RO/EST.NO. 9268644 DWG. 3 OF 1 P504 ISSUE DATE CONCRETE PAD DIMENSION at&t 1 3/14 ____•.----- \ 3'CPC For 48.5" ,......"'N, 3. deal fr.' Conduit toeledric OM (See Detail owc, 10.8. Det w... o .E,Eow I — O Conduit for • Power pedestal. copper and Solid n LNG. EMT cable •\ 1'CPC copper qma wln: (Me(Mad DWG) Power O veered \--�� ALP-MSS �elYl CABINET I I Main cabinet solid Y2 AVG OM Ba copper ground win. OM Bar t.....„0 .S' Y Itp AC ground wile .. Ground REAR VIEW ring 24-IR.n maximum / fromedge ol comete pad Ground rang w ALP-448S CABINET DIMENSIONS 'Mom.Solid S ft.ground cads. Y2 ANC copper minimum of ground. SCALE no/to auks located r oppoposite ends of the cabinet v ^-•r m.. 46L CONSTRUCTION NOTES: --- .IN EXCAVATE OF CIE PACT DG DEEP ENOUGH TO PUCE/ .'. PLACES XF4-W5COM WELDED GRAVEL -CONCRETE SHOULD BE A MINIMUM OF 5.5 INCHES. ,---� -PUCE1X4W5 NELCED HARE FABRIC APPROX.2INGHE5 r}f`" /\ %D 3 01111 21 7:BOX SPLICE • BELOW E CONCRETE SURFACE FOR THE CONCRETE PAD. PLASTIC ROUND 4510. • -W NOT TISECl1RE MOUTING BRACKET UNM THE DHFORCEMENTNIRE la IN PU HM CE.WHEN PLACED KE BRURS THE BMCKEF IS LEVEL r -FORG CONDUIT FRAME AROUNDAND THE SECURE IT WITH Y��_ FOR THE CONDUIT TEMPLATE AND SECURE IT WITH WOOD SLREWFOOT '�� HE II -PCREWS,iGROUND RODS ON EACH SIDE CABINET .n.-,,,Y DA ft318801 JUST OUTSIDE OF TIE FORM.THE TOP OF THE GROUND RODS MUST BE AT LEAST 6 INCHES BELOW GRADE. I USING GROUND CLAMPS ATTACHED 52 NAG GROUND anar ve.eRLr.o,,„..r • A WIRE MO RUN THEM UNOEWEATH THE PAD AND HAVE I THEM COME 1A INSIDE OF THE CONDUIT TEMPLATE. GEOCO NLIS FRONT LEAVE APPROX.A 5 FT.COL FOR EACH. EXCL sNsul2 r DOOR -THE SAI LEAVING",EAGE NSUE ANT FROMTHE EW IMJw RING TO COIL MADE. ENDR. µVW ROBIELOS TEL.(401)O06a11s -ENSURE THAT THE TOP SURFACE MALL BE APPROX.2 SIDE \ INCHESPIA ABOVE THE SURROUNDINGORABUTTING AFTER CONCRETE AND O. ENGR ARC VONDNrgap ODOR -WHEN LTAREA,ENSURE NNE T SURFA E CONCRETE AND OR ASPHALT AREA,ENSURE THE TOP SURFACE IS FLUSH MATH TYPE K CONS, PROJECT THE HE SURFACE MOUNTING SURROUNDING GRADE. UGHTSPEED i - E TOP TOP SURFACE OF TIE BRACKET SHOULD BE VISIBLE AHD FREE OF CONCRETE 1MEN THE FRONT VIEW PAD IS COMPLETE. ROEST.ND. 9268644 DWG. 4 OF 7 P504 6" 132" 1 6"E- 1 ISSUE DATE Oat8a l 1 3/14 holey • • CONTRUCTION NOTES: NP 1 2" 1) CAST IN PLACE. • SPACING-_ 2"CLR • (TYP) ____„_� 2) FORMED WALL - APPROX. 1' TO 4' TALL O x 6" WIDE On • • O ALP-448S I 3) REBAR PLACED APPROX. EVERY 12" O CO (VERTICALLY) O I • 4) REBAR PLACED APPROX. EVERY 12" (HORIZONTALLY) • 5) BACKFILL TYPICALLY 4" BELOW TOP OF - WALL. 6) CONSTRUCT WITH CLASS A CONCRETE. 14 0 12"0C 7) FOOTING APPROX. 6" A-A _1'-6" I 42" #4 REBAR (TYP) 1"CLR (TYP) ^' 1 I I A n i ji " ` , 1.(O .......,___________,.........._______..... 60. ..., .�,...,.�., .. ,9,.P.• . :. .,..Ii.1..1.1%..„.�I.•I...13 NOT TO SCALE �fi •'• ;octi .too sett SECTION B-B �- DA 8318801 SECTION A-A GIASS I Una, - AGGREGATE BASE .0.0 "`1° (COMPACTED 95%) EXCH. SN' 13 ENGR. ALLAN R0SIEL0S TEL 1{08153541,19 ENGR ARC VO(0.1.9Ap TYPE OF CONST. PROJECT LDrtWEED REINFORCED RETAINING WALL DETAIL ROES'.NO. 9263844 DNC. 9 OF T PSU