Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENC2013-00037
rSIC L q Print Form CITY OF CAMPBELL ENCROACHMENT PERMIT Permit No O k2, -0OC 37 DEPT.OF PUBLIC WORKS (for working within the public X-Ref.File /' 70 North First Street right-of-way) Application Date Z( 71 1 Campbell,CA 95008 / I Application Expiration Date el7 I J3 Ph. (408)866-2150 Issued `-1 APN Fx. (408)376-0958 2/� ' I y. kD4 'oS y Permit Expiration Date I APPLICATION-Application is hereby made for a Public Works Permit in accordance with Campbell Municipal Code,Section 11.04. (Application expires in six (6) months if the permit is not issued. Application Fee is non-refundable.) A. Work Address or Tract No.: I(( V// i'J/A4 �) Utility Trench Location: B. Nature of Work: 73 € '2( 1 OF Z'( Cc›Aio vt7, SET 33� !/qvL� C. Attach four(4)copies of an engineered plan showing the location and extent of the work,and four(4)copies of the preliminary Engineer's Estimate of work. The plans shall show the relation of the proposed work to existing surface and underground improvements. When approved by the City Engineer,said plan becomes a part of this permit. D. All work shall conform to the City of Campbell Standard Specifications and Details for Public Works Construction;the General Permit Conditions listed on the reverse side;and the Special Provisions for this permit,listed below. Failure to abide by these conditions and provisions may result in job shutdown and/or forfeiture of Faithful Performance Sureties and cash deposits. (See General Permit Conditions 1 and 2.) E. The Contractor must have this permit and approved plans at the site and must notify the Public Works Department at least two days before starting work. Notice must be given to Public Works at least 24 hours before restarting any work Name of Applicant: nn - Telephone: ) O LC �vr,� �v�4 Cs�yG'�EST (7 '?JO —• �lg Address: &5 ) D /T�� Srz Cam 9 E-Mail Address: ��� ,� ,. C 24-HOUR EMERGENCY PHONE NUMBER: j Is this work being done by the property owners at their own residence? YES NO The Applicant/Permittee hereby agrees by affixing their signature to this permit to hold the City of Campbell,its officers,agents,and employees free,safe and harmless from any claim or demand for damages resulting from the work covered by this permit. The Applicant/Permittee hereby acknowledges that they have read and understand both the front and back of this permit,and they will inform their contractor(s) of the information. Applicant is advised that upon issuance of this permit, property owner, or property owner's successors, shall be responsible for any and all damages arising out of the condition of any private im ments i public right-of-way. Accepted: 2/7/3 (Applicant Permittee)__ (sign) Date ^^ - (Contractor) (Print Name) Date SPECIAL PROVISIONS: 1. Street shall not be open cut for underground installations. Minimum cuts may be allowed for connections or exploration holes. Such cuts may be specifically approved by the Inspector prior to cutting. __2. Pavement may be cut for underground installations and must be restored in accordance with the Standard Details Trench Restoration Method "A",unless otherwise approved by the Engineer. 3. Work to be staked by a licensed Land Surveyor or Civil Engineer and two(2)copies of the cut sheets sent to the Public Works Department before starting work 4. Per Section 4215 of the Government Code this permit is not valid for excavations until Underground Service Alert(USA)has been notified and the inquiry identification number has been entered hereon. USA Phone: 1-800-227-2600. USA TICKET NO. 5. Prior to any work,the property owner shall execute an Agreement for Private Improvements in the Public Right-of-Way,which shall be recorded. _ _6. Public Notification Requirements: 7. SEE PUBLIC WORKS FEE SCHEDULE FOR CURRENT FEES AMOUNT RECEIPT PERMIT APPLICATION FEE S 3 7U PLAN CHECK DEPOSIT S SECURITY FOR FAITHFUL PERFORMANCE/LABOR&MATERIALS S CONSTRUCTION CASH DEPOSIT S PLAN CHECK&INSPECTION FEE S '7O EMERGENCY PERMIT FEE S APPROVED FOR ISSUANCE 2t7 ( 13 For City Engineer Date Permit Expires 12 Months After Date of Issuance GENERAL PERMIT CONDITIONS • A Construction Cash Deposit is required. Charges will be made against this deposit if there is an emergency call-out,overtime inspection or when City ordered barricading is required. Any such costs in excess of the deposit will be billed to the Permittee. 2. A one-year maintenance period and surety are required. Such period will begin on date of written acceptance by the City. 3. Refund or the cash deposit balance and refund or cancellation of the Faithful Performance Surety will be initiated by the written acceptance of the work by the City. 4. The Permittee must request in writing a final inspection and acceptance of the work upon completion. Acceptance by the City will be made in writing to the Permittee. S. Maintain safe pedestrian and vehicular crossings and free access to private driveways,bus stops,fire hydrants,and water valves. 6. A Construction Traffic Control Plan and a Construction Schedule are required for all lane closures,detours,and street closures. This plan must be reviewed and approved prior to any lane closures. 7. A Construction Traffic Control Plan shall conform to the Caltrans Manual of Traffic Controls for Construction and Maintenance Work Zones,dated 1990,available at Caltrans. Traffic control equipment shall include Type II flashing arrow signs if required. 8. Replace as directed by the City Engineer any damaged or removed improvements in accordance with City Standards and Specifications at the sole expense of the Permittee. 9. Sawcut for all PCC or AC removals. All PCC removals shall be to the nearest scoremark and shall be doweled to existing improvements. 10. Prior approval of inspector is required for any work done after normal working hours,on weekends or holidays and may require reimbursement of inspection costs at the current overtime rate. 11. Adequate signing and barricading is required on the job site. Failure to provide such signing and barricading may result in the City's providing signing and barricades and charging the cost(including all labor and materials)against the cash deposit. 12. Compaction testing of subgrade,base rock,and asphalt concrete by Permittee is required unless otherwise stated by the City Engineer. 13. The Contractor or Permittee will have a supervisory representative available for contact on the project at all times during construction. Contractor or Permittee shall provide a phone number at which they can be contacted outside the hours of 8:00 a.m.to 4:00 p.m. 14. No storage of materials or equipment will be allowed near the edge of pavement,the traveled way,or within the shoulderline which would createa hazardous condition to the public. 15. This permit shall not be construed as authorization for excavation and grading on private property adjacent to the work or any other work for which a separate permit may be required,nor does it relieve the Permittee of any obligation to obtain any other permit required by law. 16. This permit does not release the Permittee from any liabilities contained in other agreements or contracts with the City and any other public agency. 17. This permit is not transferable. Work must be performed by the Permittee or his designated agent or contractor as specified thereon. 18. Call back(call out)due to emeregencies regarding this permit shall be at the current overtime rate with a three(3)hour minimum charge per occurrence. 19. Pursuant to Chapter 14.02 of the Campbell Municipal Code,applicant shall not cause to be discharged any material into the municipal storm drain system other than storm water. Applicant shall adhere to the BEST MANAGEMENT PRACTICES established by the Santa Clara Valley Urban Runoff Pollution Prevention Program. 20. If the public interest requires a modification of,or a departure from the plans and specifications,the City shall have the authority to require or approve any modification or departure and to specify the manner in which the same is to be made for City-owned or maintained facilities. 21. Permitttee must provide advance notification to all parties that may be affected by the permit activities. Notification shall be reviewed by the City prior to distribution and include dates of work and a contact name and phone number. Applicant shall be responsible for ensuring that all those providing services under the applicant are aware and understand all of the above conditions. Applicant Date: 7// a//A) cm/�7 Contractor (Print Name) Date: 1:\FORMS\Templates\Encroachment Permits\Encroachment Permit STATIC form2.pdf Rev.09/10 , , olleicast 0.„.,, ,,,,,-:0:,,,--o ,Gt,, Gz.09� �� CALIFORNIA DIVISION p��S • di •�, No' PFt Gib r�� es BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT PP peg �" ^���`' 3055 COMCAST PLACE, LIVERMORE, CA 94551 • V�or�Lo��o�obe d���o vol Ove BORE AND PLACE CONDUIT 1161 VIRGINIA AVE CAMPBELL , CALIFORNIA PROJECT ID: 108550 DRAWING INDEX SHT NO. DESCRIPTION 1 TITLE PAGE 2 LEGEND & GENERAL NOTES 3 LAYOUT PLAN 4 TRAFFIC CONTROL PLAN 5 DETAIL 6 STORM WATER PROTECTION PLAN 7 TRAFFIC CONTROL SIGNS AND NOTES THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 1161 VIRGINIA AVE omcast IMPORTANT NOTICE n DESIGN: REV DESCRIPTION DATE TITLE PAGE PROJ#: CAM-1161 VIRGINIA AVE—BORE—WP Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 2/7/2013 DRAWN BY: JUR "Permit to Excavate" will be valid For your Dig Alert I.D. APPROVED: CALL TOLL FREE CALIFORNIA DIVISION 48 HOURS BEFORE YOU DIG APPROVED: CONSTRUCTION TYPE: BORE AND PLACE CONDUIT BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBF SHEET: 1 OF 7 SYMBOLS WORK SITE MAP AREA SCALE: NONE A GENERAL NOTES TRANSFORMER • NEW COMCAST POWER SUPPLY ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS. V-, t1. ia'" G e-1G ' STREET LIGHT ., NEW COMCAST LOW PROFILE m 8 POWER SUPPLY W/ METER 2. CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 tip ` ,. «.c•• .r.;s ■ ' ' TRAFFIC SIGNAL COMBINATION HOURS (AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION �� 4 • ,ei;� , r BY CALLING (800) 227-2600. • u7.Q NEW COMCAST VAULT i tiw �'• °" O FIRE HYDRANT , 7 1- ; � , X NEW COMCAST PEDESTAL 3 CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES t ' Ili- t }I .,k p :,, A MONUMENT PRIOR TO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON PLANS ARE ! #'i, ( I 1, M BORE PIT APPROXIMATE, CONTRACTOR MUST VERIFY. . - ,� !' ' i' 1 ; i a w "-,,,,,:n. : FM CATCH BASIN 4. CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OF - • k Cgo NEW RISER ATTACHED TO POLE CONSTRUCTION. ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE. j x ® STORM DRAIN MANHOLE a ® EXISTING POLE 5. CONTRACTOR SHALL KEEP A COPY OF APPROVED PLAN(S) AND PERMIT(S) AT THE 1,7•;n4-;;•-,.2„ t'''• : i -, ^�- 0 WATER MANHOLE JOB SITE AT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY L','-- :sf ,' zrr" '= ° ,,i -,,1 ; ..... „ ISI EXISTING COMCAST VAULT OF CAMPBELL AND/OR LAW ENFORCEMENT UPON REQUEST. " V .• -_ , :' t ; �"'" �' ® SANITARY SEWER MANHOLE i....-OW„ 47 * • 1 g.aa- ® EXISTING COMCAST PEDESTAL 6. CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED 7"v 1 .< aa • SHALL BE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO �4 • ?' 1 Q - i ` '�' ® SEWER CLEAN OUT x _ �3 o EXISTING IRRIGATION VAULT REPLACING EXISTING STRIPING AND REMOVING UNNECESSARY "USA" MARKINGS. " ,' �° c 5` ® ELECTRIC MANHOLE 7. CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISE .�:--.._..r_�. -' m , . CI EXISTING UTILITY VAULT/PEDESTAL APPROVED IN WRITING BY THE "CITY ENGINEER." ® UNIDENTIFIED MANHOLE " , -L)-(1--- GAS/WATER VALVE 8. CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE , AI Q TREE/BUSHES ® WATER METER WITH THE CITY SPECIFICATIONS,OF ANDAMPBELL AND STATE CURRENT CALFORNIAOF CALIFORNIA STANDARD PLANS DEPARTMENT OF TRANSPORTATION CAMPBELL, CALIFORNIA ' yolk If © GAS METER "MANUAL OF TRAFFIC CONTROLS AND MAINTENANCE OF HAZARD ZONE" AND "MANUAL OF WARNING SIGNS, LIGHTS AND DEVICES" FOR USE IN PERFORMANCE OF WORK UPON HIGHWAYS. FLASHING ARROW SIGNS SHALL BE REQUIRED FOR ALL LANE CLOSURES. ABBREVIATIONS PROPOSED 9. CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITH REGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVING THIS PROJECT PROPOSES TO BORE 121' L.F. COMCAST COMCAST PL PROPERTY LINE JURISDICTION AT THIS WORK SITE, INCLUDINC BUT NOT LIMITED TO THE STATE OF PLACE (1) NEW B-36 VAULTS. INSTALLATION OF CONTACTS CENTER LINE PUE PUBLIC UTILITY EASEMENT CALIFORNIA PUBLIC UTILITY COMMISSION (CPUC), THE STATE OF CALIFORNIA ONE (2) - 2" HDPE CONDUIT, PLACE AND INSTALL (E) EXISTING R/W RIGHT OF WAY OCCUPATIONAL SAFETY AND HEALTH ACT (CAL OSHA), THE COUNTY OF SANTA CRUZ FIBER OPTIC AND COAX CABLE INTO CONDUIT. FOC FACE OF CURB SD EXISTING STORM DRAINJEAN LEE AND THE CITY OF MIN MINIMUM SS EXISTING SANITARY SEWER CAMPBELL. THIS PROJECT IS NECESSARY TO MAINTAIN THE PERMIT MANAGER MAX MAXIMUM T EXISTING TELEPHONE 10. ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TO INSPECTION BY CITY ENGINEER COMCAST CABLE SYSTEM OPERATIONAL AND TO CABLECOM CDT CONDUIT W EXISTING WATER AND/OR AN AUTHORIZED AGENT OF COMCAST. UPGRADE OUR SERVICES OF DIGITAL CABLE (408) 569-4016 LINETYPES TELEVISION, DIGITAL TELEPHONE, AND HIGH SPEED KEVIN SMITH 11. CONTRACTOR SHALL "RED-LINE" ALL LAYOUTS, PLANS AND DETAILS, ON THE DAY OF DATA FOR OUR CUSTOMERS IN THE CITY OF PERMIT COORDINATOR CAP/ PROPOSED OVERLASH OVERRIDE ROUTE CONSTRUCTION AND SUBMIT A COMPLETE SET OF "AS-BUILT" PLANS TO COMCAST CAMPBELL. (7O7) 58O-4418 / UPON COMPLETION OF THE PROJECT. - - - - PROPOSED TRENCH/BORE ROUTE 12. CONTRACTOR SHALL NOTIFY RESIDENTS AFFECTED BY THE WORK IN LANDSCAPED EXISTING COMCAST ROUTE AREA IN ADVANCE OF CONSTRUCTION. T EXISTING TELEPHONE SYSTEM 13. CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE E EXISTING ELECTRICAL SYSTEM OF WORK COMMENCING. - G EXISTING GAS SYSTEM 14. LANE CLOSURES ARE PROHIBITED BEFORE 8:30 AM AND AFTER 4:00 PM (3:00 PM TV EXISTING TV SYSTEM OF FRIDAYS AND ON DAYS PRECEEDING DESIGNATED LEGAL HOLIDAYS). NO LANE CLOSURES ARE PERMITTED ON WEEKENDS AND HOLIDAYS. IRR EXISTING IRRIGATION SYSTEM JT EXISTING JOINT TRENCH ss EXISTING SANITARY SEWER SD EXISTING STORM DRAIN - w -- EXISTING WATER LINE x x x EXISTING FENCELINE Ct ROADWAY CENTER LINE - - - - PROPERTY LINE IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 1161 VIRGINIA AVE omcast REV DESCRIPTIONDATELEGEND AND GENERAL NOTES T Section # 4216/4217 of the Government Code requires a DESIGN: '� Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 2/7/2013 �) ` DRAWN BY: JUR PROJ#: CAM-1161 VIRGINIA AVE—BORE—WP //` "Permit to Excavate" will be valid For your Dig Alert I.D. t0 I APPROVED: i CALL TOLL FREE CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALIFORNIA DIVISION 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 1-800-227-2600 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 APPROVED: NODE: GNBF SHEET: 2 OF 7 40' 6' 20' cl. 1 t FOC Siz E O 2+5 a w a -► 2+34 0 2+37 FOC PARK STRIP SIDEWALK BORE PIT 3'X3' -, NEW CAN B-36 VAULT 0/S 1' a FAIRLAND AVENUE UTILITY POLE 0/S 2' 1+95 1+90 'z 1+85 w o BORE ROUTE I N o <3 ` a --� , in - u_ o BORE PIT 3'X3' ' a/ 1+20 44- ,►'- -a- - • 1+11 Y� UTILITY POLE ANCHOR HACIENDA AVENUE SCALE 1:40 a HACIENDA AVENUE SIDEWALK PARK STRIP FOC Z Z +00 FOC a i. IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 1161 VIRGINIA AVE r"i" i n DESIGN: REV DESCRIPTION DATE LAYOUT PLAN OIMCICISt TSection # 4216/4217 of the ber torrent Code requires o i'� Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 2/7/2013 .I ` DRAWN BY: JUR PROJ#: CAM-1161 VIRGINIA AVE—BORE—WP //' "Permit to Excavate" will be valid For your Dig Alert I.D. �lr•(, I APPROVED: i CALL TOLL FREE CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALIFORNIA DIVISION Y 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CAUFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBF SHEET: 3 OF 7 W20-1 IIINU i T O G20-2 in t W21-5 �p s,....... , (-7) T FOC FLAGGER USED FOR Q TRAFFIC CONTROL w -� C ARROW FLASHING BOARD oPARK cr STRIP SIDEWALK e---- + • FAIRLAND AVENUE N • W 25 MPH Z (7 0 Z I • W Y a_ cr I • I-J Q ^ ,. O ,_ I I . o F+� Z I : D QN n CD I • 11 La H J I J Q I I- (i) f' "" OD • Y �A � 25 MPH ..44P.- G20-2 N HACIENDA AVENUE SCALE : NTS ■ HACIENDA AVENUE SIDEWALK PARK STRIP FOC Z Z FOC IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 1161 VIRGINIA AVE omcast EV DESCRIPTION DATE 4 TRAFFIC CONTROL PLAN Section # 4216/4217 of the Government Code requires a DESIGN: '� Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 2/7/2013 •� ` DRAWN BY: JUR PROJ#: CAM-1161 VIRGINIA AVE—BORE—WP �, I "Permit to Excavate" will be valid For your Dig Alert I.D.ID i CALL TOLL FREE APPROVED: Y 48 HOURS BEFORE YOU DIG CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALIFORNIA DIVISION APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBF SHEET: 4 OF 7 MEETS NO. 6 STATE SPECIFICATIONS, CALIFORNIA DIVISION OF HIGHWAYS r t:.. 22-1/4" i 35-1/4" ..w. ,..www.�w waaaasar •�aaaaar .i..wu• wa.AlM„• .��..M •aa/.a M• a� •i„wa.r /a ...N.M'• a• ��I, •i.....a• •iiii '�• Vf .:.usu• s yr 16-1/4" 1 .:�..... ......•.. 1211 w,w.ar.,• Is--R- Sir '!�� ' cosiiii—Ditiro. t . .. ..w.r..r• i J ' I w..aw.r. • ''O�awiaii. 1.\ I 777,72(7 5H• 29-1/4" 9-3/4" ' 1 el 'o• • v, , " .,. 2-1/4" 9. v,. ,, 1 r - -' z-1/4" - F. 17-1/2" �rt •,;l,.,,.. 1-1/2" - •1s s•t -....%.......N>7 A HIGH DENSITY REINFORCED CONCRETE BOX, WITH NON-SETTLING SHOULDERS POSITIONED TO MAINTAIN GRADE AND FACILITATE BACKFILLING. s •.a .Y,•4, .V.. .�,*.• APPROXIMATE DIMENSIONS SHOWN. ';'3 -y .,•a`,: ......*N4. B36 VAULT DETAIL 't SCALE: N.T.S. f IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 1161 VIRGINIA AVE n REV DESCRIPTION DATE DETAIL omcast Section # 4216/4217 of the Government Code requires a DESIGN: Dig Alert Identification Number f to be issued before a 0 ISSUE FOR PERMIT 2/7/2013 DRAWN BY: JUR PROD{/: CAM-1161 VIRGINIA AVE—BORE—WP l/// ` "Permit to Excavate" will be valid For your Dig Alert I.D. lr`0 APPROVED: i CALL TOLL FREE CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALIFORNIA DIVISION 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBF SHEET: 5 OF 7 STORM WATER PROTECTION PLAN GRAVEL BAG(S)OR OTHER ACCEPTED SEDIMENT CONTROL BMP.PLACE BAGS PLACEMENT AT TYPE PLACEMENT AT TYPE NOTES TIGHT AGAINST FACE OF CURB. B AND E DROP INLETS, A, C, D, & F DROP INLETS I's"F,AL'L"B°NO OREI HANOABEH CTARES(2 AND PARKING LOTS ACRES} EXISTING (PEN 2,THE FILTER BAG SHALL BE MANUFACTURED BACK OF CURB BACK HOOD 5 CM (2') DETAIL A EXISTING DROP FROM UV RESISTANT POLYPROPYLENE.NYLON. MINIMUM INLET GRATE POLYESTER OR ETHYLENE FABRIC WITH A MINIMUM TENSILE STRENGTH OF 50 LBS PER FACE OF CURB SEE NOTE 2 DAM DETAIL A NOT GREATER THAN 20 SSIEVEAND WITH A� CURB MINIMUM FLOW RATE OF 40 1 GALLONS FT. • r. • 4 •••■ 3,THE HELD IN PLACE FILTER BAG MAY D FROM Y THE EXISTING OR f • : GRATE(OR OTHER APPROVED METHOD), r .' 1, BAG WIDTH .Y PROVIDING NO MODIFICATION OR DAMAGE FLOW / FRAME.THE INLETOGRATE THE SHAL ET GRATE BE /hII ......IIIIIIIIIIIIIIIII. 5 CM (2 ° •'45° ' MINIMUM GRATE) CONTACT CAUSED TO REST MORE THAN 13MM(.5')U AT BACKAT FRONT CONTACT, ABOVE THE INLET FRAME(SEE DETAIL A} (FLED \ ALL SIDEAND SIDES 4,THEFILTERBAGMAYEXTENDTOTHE U U --� BOTTOM OF THE INLET BOX PROVIDED THE • URELEASE) OUTLET PIPE IS UNOBSTRUCTED. V MAXIMUM 5 FLOWS SHALL NOT BE ALLOWED TO BYPASS LIP OF GUTTER BAG DEPTH THE BAG.THE BAG OR ITS FRAME SHALL CATCH FLOWS AT ALL SIDES OF THE INLET, EXCEPT AS SHOWN FOR FLOOD RELEASE. DRAINAGE INLET OUTLET PIPE 6 INLET FILTER BAGS SHALL BE INSPECTED OUTLET PIPE WEEKLY AND AFTER EACH RAINFALL DURING WITH FILTER BAG DETAIL A DRY SEASON.SO SEDIMENT AND Po L DEBRIS SHALL BE REMOVED BEFORE ACCUMULATIONS HAVE EXISTING DROP 1,3 CM (.5') REACHED ONE THIRD THE DEPTH OF THE BAG. NOTES: INLET GRAT MAXIMUM BAGS SWILL BE REPAIRED OR REPLACED AS SOON AS DAMAGE OCCURS. 1.)SEDIMENT TRAPPED UPSTREAM OF INLET SEDIMENT SEDIMENT CONTROL BMP SHALL BE PLAN VIEW REMOVED WEEKLY AND PRIOR TO A CONTROL RAINFALL EVENT. STORM DRAIN INLET 2.)PLACE BMP'S TIGHTLY TOGETHER AT FILTER B FILTER BAG JOINTS TO PREVENT OR MINIMIZE FRAME EXISTING DROP SEEPAGE AT JOINTS. (OPTIONAL) INLET FRAME IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 1161 VIRGINIA AVE omcast REV DESCRIPTIONDATE DESIGN: 013 STORM WATER PROTECTION PLAN 4 Section # 4216/4217 of the Government Code requires a 0 ISSUE FOR PERMIT 2/7/2E /I'� Dig Alert Identification Number to be issued before a DRAWN BY: JUR PROJ#: CAM-1161 VIRGINIA AVE—BORE—WP /� "Permit to Excavate" will be valid For your Dig Alert I.D. l(�, I APPROVED: •.,i CALL TOLL FREE CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALIFORNIA DIVISION v 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBF SHEET: 6 OF 7 LEGEND • Traffic Cone or Delineator -r Sign , Direction of Travel ( Not a pavement marking ) W20-1 W3-4 C9A ic<KJ Flashing Arrow Sign (Where Required) ROAD BE Refer to Page 7 of Caltrans manual WORK PREPARED END Type A, Type I , or Type II . AHEAD TO ROAD WORK STOP Y High Level Warning Device (Flagtree) G20-2 TABLE A 1----i 3arricade (For Excavation Only) TAPER NO. OF SPACING OF CONES SIGN SPACING (S) Refer to Page 12 of Caltrans manual APPROCH LENGTH CONES ALONG TAPER ADVANCE OF TAPER to select for Details ,o n SPEED (L) PER TAPER (FEET) 8 BETWEEN SIGNS Type I , Type 11 , or Type III 25 MPH 125 FT. 6 25FT. 150 FT. 30 MPH 180 FT. 7 30FT. 200 FT. !MI 35 MPH 245 FT. 8 35FT. 250 FT. Flagg e r 40 MPH 320 FT. 9 40FT. 350 FT. 45 MPH 540 FT. 13 45FT. 550 FT. 50 MPH 600 FT. 13 SOFT. 600 FT. 55+MPH 1000 FT. 21 55FT. 1000 FT. NOTES: 1 . Flaggers will be used to control traffic at non—signalized intersections. Flaggers Will use 2 way radios when a 24' (min) roadway cannot be maintained. 2. No Parking/Tow Away signs will be posted 48 hours in advance to clear work zone. 3. All construction zone signs/directional signs will conform to Caltrans specs. Signs will be spaced 150 feet apart where applicable. 4. Same traffic control plan will apply at other similar locations and opposite side of street. 5. Use flag trees on all C-18/C-23 signs. IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 1161 VIRGINIA AVE omcast REV DESCRIPTION DATE TRAFFIC CONTROL NOTES AND SIGNS Section # 4216/4217 of the Government Code requires o DESIGN: '� Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 2/7/2013 �� ` DRAWN BY: JUR PROJ#: CAM-1161 VIRGINIA AVE—BORE—WP //// "Permit to Excavate" will be valid For your Dig Alert I.D. �`�, I APPROVED: i CALL TOLL FREE CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALIFORNIA DIVISION v 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBF SHEET: 7 OF 7