Loading...
HomeMy WebLinkAboutENC2013-00044 r f • Print Form Irr CITY OF CAMPBELL ,P""' ,t , ENCROACHMENT PERMIT Permit No G N C?Q\ At-0c DEPT.OF PUBLIC W (K5 (for working within the public X-Ref.File 70 North First Street e�013 right-of-way) Application Date Campbell,CA 95008 `'AR Q 4 L 3 15' It Application Expiration Date 3-14— Ph. (408)866-2150 i`1f'� Issuedn 7 ` APN Fx. (408)376-0958 Ad fn.\SlatU *II j 1 C \NUCVS Permit Expiration Date 7 j 7 APPLICATION-Application is hereby made for a Public Works Permit in accordance with Campbell Municipal Code,Section 11.04. (Application expires in six (6) months if the permit is not issued. Application Fee is non-refundable.) I , r� A. Work Address or Tract No.: ,�lts S , w/A3 � 'S [�� v' 4/40. Utility Trench Location: R t� � V" 6 , B. Nature of Work: ' ,2pa (mot Qy j C — . VAuL /T C. Attach four(4)copies of an engineered plan showing the location and extent of the" work,and four(4)copies of the preliminary Engineer's Estimate of work. The plans shall show the relation of the proposwork to existing surface and underground improvements. When approved by the City Engineer,said plan becomes a part of this permit. / 7s2z7 D. All work shall conform to the City of Campbell Standard Specifications and Details for Public Works Construction;the General Permit Conditions listed on the reverse side;and the Special Provisions for this permit,listed below. Failure to abide by these conditions and provisions may result in job shutdown and/or forfeiture of Faithful Performance Sureties and cash deposits. (See General Permit Conditions 1 and 2.) E. The Contractor must have this permit and approved plans at the site and must notify the Public Works Department at least two days before starting work. Notice must be given to Public Works at least 24 hours before restarting any work. Name of Applicant: �- `-eg :mo d.Qi t F C 4j-7 Telephone: (707) 0,o— CAI/ Address: Z -2) A4-'00 A `�% S1^H1-. ��-�./�jiQ/�S- Q.4 9 2 S E-Mail Address: /� `S C eAbk L, `/c 24-HOUR EMERGENCY PHONE NUMBER: (-2Z1?) gapIs this work being done byy the property owners at their own residence? E YES <NO The Applicant/Permittee hereby agrees by affixing their signature to this permit to hold the City of Campbell,its officers,agents,and employees free,safe and harmless from any claim or demand for damages resulting from the work covered by this permit. The Applicant/Permittee hereby acknowledges that they have read and understand both the front and back of this permit,and they will inform their contractor(s) of the information. Applicant is advised that upon issuance of this permit, property owner, or property owner's successors, shall be responsible for any and all damages arising out of the condition of an priva mprovements in the public right-of-way. Accepted: 4/4/43 (Applicant Permittee) ign Date Xi4A5"i (Contractor) (Print Name) Date SPECIAL PROVISIONS: 1. Street shall not be open cut for underground installations. Minimum cuts may be allowed for connections or exploration holes. Such cuts may be specifically approved by the Inspector prior to cutting. ___2. Pavement may be cut for underground installations and must be restored in accordance with the Standard Details Trench Restoration Method "A",unless otherwise approved by the Engineer. 3. Work to be staked by a licensed Land Surveyor or Civil Engineer and two(2)copies of the cut sheets sent to the Public Works Department before starting work. 4. Per Section 4215 of the Government Code this permit is not valid for excavations until Underground Service Alert(USA)has been notified and the inquiry identification number has been entered hereon. USA Phone: 1-800-227-2600. USA TICKET NO. 5. Prior to any work,the property owner shall execute an Agreement for Private Improvements in the Public Right-of-Way,which shall be recorded. _6. Public Notification Requirements: 7. SEE PUBLIC WORKS FEE SCHEDULE FOR CURRENT FEES AMOUNT RECEIPT NO. PERMIT APPLICATION FEE $ 3 7a Q PLAN CHECK DEPOSIT $ SECURITY FOR FAITHFUL PERFORMANCE/LABOR&MATERIALS $ CONSTRUCTION CASH DEPOSIT $ /' PLAN CHECK&INSPECTION FEE $ S 7O EMERGENCY PERMIT FEE S APPROVED FOR ISSUANCE 31 5J t 3 For City Engi eer Date Permit Expires 12 Months After Date of Issuance r S GENERAL PERMIT CONDITIONS I. A Construction Cash Deposit is required. Charges will be made against this deposit if there is an emergency call-out,overtime inspection or when City ordered barricading is required. Any such costs in excess of the deposit will be billed to the Permittee. 2. A one-year maintenance period and surety are required. Such period will begin on date of written acceptance by the City. 3. Refund or the cash deposit balance and refund or cancellation of the Faithful Performance Surety will be initiated by the written acceptance of the work by the City. 4. The Permittee must request in writing a final inspection and acceptance of the work upon completion. Acceptance by the City will be made in writing to the Permittee. 5. Maintain safe pedestrian and vehicular crossings and free access to private driveways,bus stops,fire hydrants,and water valves. 6. A Construction Traffic Control Plan and a Construction Schedule are required for all lane closures,detours,and street closures. This plan must be reviewed and approved prior to any lane closures. • 7. A Construction Traffic Control Plan shall conform to the Caltrans Manual of Traffic Controls for Construction and Maintenance Work Zones,dated 1990,available at Caltrans. Traffic control equipment shall include Type II flashing arrow signs if required. 8. Replace as directed by the City Engineer any damaged or removed improvements in accordance with City Standards and Specifications at the sole expense of the Permittee. 9. Sawcut for all PCC or AC removals. All PCC removals shall be to the nearest scoremark and shall be doweled to existing improvements. 10. Prior approval of inspector is required for any work done after normal working hours,on weekends or holidays and may require reimbursement of inspection costs at the current overtime rate. 11. Adequate signing and barricading is required on the job site. Failure to provide such signing and barricading may result in the City's providing signing and barricades and charging the cost(including all labor and materials)against the cash deposit. 12. Compaction testing of subgrade,base rock,and asphalt concrete by Permittee is required unless otherwise stated by the City Engineer. 13. The Contractor or Permittee will have a supervisory representative available for contact on the project at all times during construction. Contractor or Permittee shall provide a phone number at which they can be contacted outside the hours of 8:00 a.m.to 4:00 p.m. 14. No storage of materials or equipment will be allowed near the edge of pavement,the traveled way,or within the shoulderline which would create-a hazardous condition to the public. 15. This permit shall not be construed as authorization for excavation and grading on private property adjacent to the work or any other work for which a separate permit may be required,nor does it relieve the Permittee of any obligation to obtain any other permit required by law. 16. This permit does not release the Permittee from any liabilities contained in other agreements or contracts with the City and any other public agency. 17. This permit is not transferable. Work must be performed by the Permittee or his designated agent or contractor as specified thereon. 18. Call back(call out)due to emeregencies regarding this permit shall be at the current overtime rate with a three(3)hour minimum charge per occurrence. 19. Pursuant to Chapter 14.02 of the Campbell Municipal Code,applicant shall not cause to be discharged any material into the municipal storm drain system other than storm water. Applicant shall adhere to the BEST MANAGEMENT PRACTICES established by the Santa Clara Valley Urban Runoff Pollution Prevention Program. 20. If the public interest requires a modification of,or a departure from the plans and specifications,the City shall have the authority to require or approve any modification or departure and to specify the manner in which the same is to be made for City-owned or maintained facilities. 21. Permitttee must provide advance notification to all parties that may be affected by the permit activities. Notification shall be reviewed by the City prior to distribution and include dates of work and a contact name and phone number. Applicant shall be responsible for ensuring that all those providing services under the applicant are aware and understand all of the above conditions. 344/3 Applicant Date: Contractor (Print Name) Date: J:\FORMS\Templates\Encroachment Permits\Encroachment Permit STATIC form2.pdf Rev.09/10 . z 0 U ce MIMI omcast ,.... 0 Lil g CO -O da Z Z . 2 Cr s.-- N E ' L o o m CALIFORNIA DIVISION C) BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT > o 3055 COMCAST PLACE LIVERMORE CA 94551 Cr O O CL a. -Q Q M BORE AND PLACE NEW VAULT 2105 S WINCHESTER BLVD CAMPBELL , CALIFORNIA PROJECT ID: 103637 DRAWING INDEX SHT NO. DESCRIPTION 1 TITLE PAGE 2 LEGEND & GENERAL NOTES 3 LAYOUT PLAN 4 TRAFFIC CONTROL PLAN 5 DETAIL 6 STORM WATER PROTECTION PLAN 7 TRAFFIC CONTROL SIGNS AND NOTES IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2105 S WINCHESTER BLVD omcast DESIGN: REV DESCRIPTION DATE TITLE PAGE Section # 4216/4217 of the Government Code requires a i'�` Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 02/28/2013 DRAWN BY: JUR PROJ#: CAM-2105 S WINCHESTER BLVD —BORE—WP "Permit to Excavate" will be valid For your Dig Alert I.D. llll�� I CALL TOLL FREE APPROVED: CONSTRUCTION TYPE: BORE AND PLACE NEW VAULT CALIFORNIA DIVISION 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL SYMBOLS WORK SITE MAP A TRANSFORMER GENERAL NOTES AREA SCALE: NONE , z. +f L 4 y. i '1S. NEW COMCAST POWER SUPPLY � ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS. +i I. STREET LIGHT �' 1- i .� NEW COMCAST LOW PROFILE �, 8 POWER SUPPLY W/ METER 2. CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 ! _ t _ It 0 TRAFFIC SIGNAL COMBINATION HOURS (AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION ''` `" ` e'I 0 NEW COMCAST VAULT BY CALLING (800) 227-2600. 7s, ; e ' I 0 FIRE HYDRANT '+` fi : A M NEW COMCAST PEDESTAL 3. CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES ri• it A MONUMENT PRIOR TO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON PLANS ARE "ff 'R ; BORE PIT �Tr APPROXIMATE, CONTRACTOR MUST VERIFY. - ;. P 1..°4, ,•+ + • � V I I I ! , pl $' I"`I CATCH BASIN 4. CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OF 1 ' �' ,TCr '�" h" 0> NEW RISER ATTACHED TO POLE CONSTRUCTION. ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE. r '. "7'.- it v _ ;• STORM DRAIN MANHOLE . ; T , r i , ¢ ® EXISTING POLE 5. CONTRACTOR SHALL KEEP A COPY OF APPROVED PLAN(S) AND PERMIT(S) AT THE .� ® WATER MANHOLE JOB SITE AT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY 5 61 EXISTING COMCAST VAULT OF CAMPBELL AND/OR LAW ENFORCEMENT UPON REQUEST. F ® SANITARY SEWER MANHOLEWIE ��7 ® EXISTING COMCAST PEDESTAL 6. CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED V �=, SEWER CLEAN OUTs' rSHALL BE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO .3. o EXISTING IRRIGATION VAULT ® REPLACING EXISTING STRIPING AND REMOVING UNNECESSARY "USA" MARKINGS. ? ® ELECTRIC MANHOLE 7. CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISE ' "' 4, 7 x ''' , r3 I= EXISTING UTILITY VAULT/PEDESTAL k ,: .: _ n. C. � ® APPROVED IN WRITING BY THE "CITY ENGINEER." UNIDENTIFIED MANHOLE �� GAS/WATER VALVE 8. CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE • , ; TREE/BUSHES ® WATER METER WITH THE CITY OF CAMPBELL AND STATE OF CALIFORNIA STANDARD PLANS AND CAMPBELL, CALIFORNIA N - SPECIFICATIONS, AND CURRENT CALIFORNIA DEPARTMENT OF TRANSPORTATION .7i ". ® GAS METER "MANUAL OF TRAFFIC CONTROLS AND MAINTENANCE OF HAZARD ZONE" AND "MANUAL OF WARNING SIGNS, LIGHTS AND DEVICES" FOR USE IN PERFORMANCE OF WORK UPON HIGHWAYS. FLASHING ARROW SIGNS SHALL BE REQUIRED FOR ALL LANE CLOSURES. ABBREVIATIONS PROPOSED 9. CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITH REGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVING THIS PROJECT PROPOSES TO BORE 60' L.F AND COMCAST COMCAST PL PROPERTY LINE JURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE STATE OF PLACE A NEW B-36 VAULT. CONTACTS Y_ CENTER LINE PUE PUBLIC UTILITY EASEMENT CALIFORNIA PUBLIC UTILITY COMMISSION (CPUC), THE STATE OF CALIFORNIA INSTALLATION OF TWO (2) 2" HDPE CONDUIT, (E) EXISTING R/W RIGHT OF WAY OCCUPATIONAL SAFETY AND HEALTH ACT (CAL OSHA), THE SANTA CLARA COUNTY, PLACE AND INSTALL FIBER OPTIC AND COAX CABLE FOC FACE OF CURB SD EXISTING STORM DRAIN AND THE CITY OF CAMPBELL. INTO CONDUIT. JEAN LEE MIN MINIMUM SS EXISTING SANITARY SEWER PERMIT MANAGER MAX MAXIMUM T EXISTING TELEPHONE 10. ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TO INSPECTION BY CITY ENGINEER CABLECOM CDT CONDUIT W EXISTING WATER AND/OR AN AUTHORIZED AGENT OF COMCAST. THIS PROJECT IS NECESSARY TO MAINTAIN THE (408) 569-4016 LINETYPES COMCAST CABLE SYSTEM OPERATIONAL AND TO 11. CONTRACTOR SHALL "RED-LINE" ALL LAYOUTS, PLANS AND DETAILS, ON THE DAY OF UPGRADE OUR SERVICES OF DIGITAL CABLE KEVIN SMITH CONSTRUCTION AND SUBMIT A COMPLETE SET OF "AS-BUILT" PLANS TO COMCAST TELEVISION, DIGITAL TELEPHONE, AND HIGH SPEED PERMIT COORDINATOR CATV PROPOSED OVERLASH/OVERRIDE ROUTE UPON COMPLETION OF THE PROJECT. DATA FOR OUR CUSTOMERS IN THE CITY OF (707) 580-4418 CAMPBELL. - --- PROPOSED TRENCH/BORE ROUTE 12. CONTRACTOR SHALL NOTIFY RESIDENTS AFFECTED BY THE WORK IN LANDSCAPED EXISTING COMCAST ROUTE AREA IN ADVANCE OF CONSTRUCTION. T EXISTING TELEPHONE SYSTEM 13. CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE E EXISTING ELECTRICAL SYSTEM OF WORK COMMENCING. G EXISTING GAS SYSTEM 14. LANE CLOSURES ARE PROHIBITED BEFORE 8:3C AM AND AFTER 4:00 PM (3:00 PM TV EXISTING TV SYSTEM OF FRIDAYS AND ON DAYS PRECEEDING DESIGNATED LEGAL HOLIDAYS). NO LANE APPROVED 1 r CONSTRUCTION' CLOSURES ARE PERMITTED ON WEEKENDS AND HOLIDAYS. IRR EXISTING IRRIGATION SYSTEM City of Campbell JT EXISTING JOINT TRENCH ss EXISTING SANITARY SEWER Public Works Permit No. et Zol,-( 9I-1 SD EXISTING STORM DRAIN w EXISTING WATER LINE Contractor must have these plans x x x EXISTING FENCELINE an the job site during construction: rt ROADWAY CENTER LINE — — — — PROPERTY LINE IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2105 S WINCHESTER BLVD c o I' Y1 c a s DESIGN: REV DESCRIPTION DATE LEGEND AND GENERAL NOTES 4 Section # 4216/4217 of the Government Code requires a l'� Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 02/28/2013 /// ` "Permit to Excavate" will be valid For your Dig Alert I.D. DRAWN BY: JUR PROJ#: CAM-2105 S WINCHESTER BLVD -BORE-WP �!r(� I APPROVED: CONSTRUCTION TYPE: BORE AND PLACE CONDUIT i CALL TOLL FREE CALIFORNIA DIVISION v 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CAUFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBC SHEET: 2 OF 7 i I • M,� 3,c.., ,, ' 2105 � � " ` ti) 0 c M w NEW CAN B-36 VAULT 0/S 20' f:4w 0 r g WATER VALVE 0/S 4' W At e CtiBORE PIT 3'X3' VH g BORE ROUTE W t... 2 m BORE PIT 3'X3' x r 8 1 1 4 tt c UTILITY POLE 0/S 2' Z ( L o '--I .4...I (i) c ` U ..:e. W t` I c0 — 0 w DRIVEWAY + + + {i (`1 I Co I ]3 33 I MJ 33 3 SS --- SS SS S` SS ' , ' + r T I o ono CO n N I ) DRIVEWAY DRIVEWAY _ ......40.- (0 M 0) M M N 0) + + + + \ o PG&E VAULT 0/S 1' «----- --- UTILITY POLE 0/S 2' o AT&T MANHOLE 0/S 9' o (E) ANCHORS WATER METER 0/S 1' 4.) t t (E) ANCHOR RINCON AVENUE 6.4,,-) z4. SCALE 1:30 • IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2105 S WINCHESTER BLVD O DESIGN: REV DESCRIPTION DATE LAYOUT PLAN 4 Section # 4216/4217 of the Government Code requires a /'�� Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 02/28/2013 "Permit to Excavate" will be valid For your Dig Alert I.D. DRAWN BY: JUR PROJ#: CAM-2105 S WINCHESTER BLVD -BORE-WP ,, I APPROVED: CONSTRUCTION TYPE: BORE AND PLACE CONDUIT •.i I CALL TOLL FREE CALIFORNIA DIVISION v 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBC SHEET: 3 OF 7 • i An IS- p 0 O i Pa C) r c5 it KEEP DRIVEWAY 2105 J Y 07 a OPEN AT ALL TIMESQ 0p o < 0 N ' ` P 1"Ye 9.. e. ARROW FLASHING BOARD �"'" ' ' c c a ♦INSTALL TEMPORARY NO PARKING SIGNS 4 0 FLAGGER USED o FOR TRAFFIC CONTROL j1 ' tt u W L.. /--- G20-2 W21-5 W20-1 O Y7 0 350' � U I 0 ■ SIDEWALK 0 AWAY ■ ■ SIDEWALKCL. WWI .Q FOC • FOC • I -.4ii � SIDEWALK FOC I 1 I FOC SIDEWALK 1 >->- ® r- — o FOC DRIVEWAY' DRIVEWAY SIDEWALK _ .. FOC SIDEWALK RINCON AVENUE 0 0 0 h t t Y W -J n O O p pv, I (7) N W�•I z ,N; SCALE: NTS IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2105 S WINCHESTER BLVD C O n DESIGN: REV DESCRIPTION DATE TRAFFIC CONTROL PLAN Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 02/28/2013 "Permit to Excavate" will be valid For your Dig Alert I.D. DRAWN BY: JUR PROJ#: CAM-2105 S WINCHESTER BLVD -BORE-WP APPROVED: CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALL TOLL FREE CALIFORNIA DIVISION 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBC SHEET: 4 OF 7 MEETS N0. 6 STATE SPECIFICATIONS, CALIFORNIA DIVISION OF HIGHWAYS .NastsaNa. .SNNr•riiiiUi YarrrNrNNrRfwA aistrrr•-'.ruwarR. AE�war` �t.rwtly, swaww' '��a 22-1/4" Z 0 f �Ittw00 35-1/4 ......... , .iaaafrrr •arsrrrra. • �anararw. r s*siu aR• of rrrraa. �. M iufr■w- �rarfu►. � r.iNrsrNar• .�qNr. riwwarr ruRrn. rirwwr •rtrrur. •ii rwiwrw•� •frrrN_. frwwr �a\a!a\ u�aNrriar RrNwas �y' �artsaNfr rNfsr■ (,� .�.� N::ai:is�r• .111., T Rarrrt iurwra n` ra+rNNN1• ^ wRISNhI i rrraffrr■ 1 1/4 ssarNrta• « h w:wiii�r o c rhhharrr+ altar\Nr' AN��f�rt� / 211 gziriOr 6 �{I .h.�rrti Nr /M_ar Rf• I O SL > C ■Narrrr■ O lrraNtrNa rtNl�lV O b �rr_Nfr. •rrrrMw'" ' t ?n �rNr RNara ` .M ue 5 d rfrwar 7arNN■N■. tt 0) •�. `rf Maaw Rt. 511 ,• \ t 7,7"." i..C.. 77umafh6ww '2y t�NrrN■■r• V 7a Na1IUN \� .•✓') rrt C L 29-1/4V.• 4 "4 •$� O �• 1' W 4 #' `,ems 2-1/4" > 1y' ' • . 17-1/4" �• 0 k,� ,, Cr O • ' " L >'... LL .a• \\,..s....N. .6, �• •4 30r� .a•. 17-1 2" • 30-1/2" Cl_1-�/2" 7< 2-1/4• rt• N' N, ■r A HIGH DENSITY REINFORCED CONCRETE BOX, WITH NON-SETTLING ' SHOULDERS POSITIONED TO IVAINTAIN GRADE AND FACILITATE BACKFILLING. • ,, ,N• • .a •9 a••.9. •;.1:r. APPROXIMATE DIMENSIONS SHOWN. -.., -.0...i...'t%-:• •4..•a . N.'s...4N B36 VAULT DETAIL 2" SCALE: N.T.S. t _ IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2105 S WINCHESTER BLVD orencast DESIGN: 0 DESCRIPTION DATE 2013 DETAIL 4 Section # 4216/4217 of the Government Code requires a 0 ISSUE FOR PERMIT 02/28/E'�` Dig Alert Identification Number to be issued before a DRAWN BY: JUR ((� I "Permit to Excavate" will be valid For your Dig Alert I.D. PROJ#: CAM-2105 S WINCHESTER BLVD -BORE-WP i CALL TOLL FREE APPROVED: CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALIFORNIA DIVISION Y 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBC SHEET: 5 OF 7 0 H U p 1- 1 h = V3 -C) Oa ; Z Z V STORM WATER O as b t PROTECTION PLAN 5 at CO 111 %.' > o O Ct U CL = CL -O Q Cl- GRAVEL BAG(S)OR OTHER ACCEPTED SEDIMENT CONTROL BMP.PLACE BAGS PLACEMENT AT TYPE PLACEMENT AT TYPE NOTES TIGHT AGAINST FACE OF CURB. B AND E DROP INLETS A, C, D, & F DROP INLETS SHALL BE NO MORE THAN SM HECTARED(2 AND PARKING LOTS ACRES} BACK OF CURB EXISTING OPEN 5 CM (2') 2.THE FILTER BAG SHALL BE MANUFACTURED BACK HOOD DETAIL A EXISTING DROP FROM UV RESISTANT POLYPROPYLENE,NYLON. MINIMUM INLET GRATE POLYESTER.OR ETHYLENE FABRIC WITH A MINIMUM TENSILE STRENGTH OF 50 LBS PER FACE OF CURB SEE NOTE 2 DAM DETAIL A LINEAL FOOT,AN EQUIVALENT OPENING SIZE CURB NOT GREATER THAN 20 SIEVE AND WITH A MINIMUM FLOW RATE OF 40 /' ' GALLONS/MINUTEISQ FT. 1 1 N. 1...i .'/L '����'I■ 3,THE FILTER BAG MAY BE SUSPENDED FROM / .• t; OR HELD IN PLACE BY THE EXISTING INLET !/ I MINIMUM ,\,' , �/ GRATE(OR OTHER APPROVED METHOD)�` PROVIDING NO MODIRCATION OR DAMAGE 1 I /) � FLOW .•� BAG WIDTH SHALL BE DONE TO THE INLET GPPTE OR S CM C2 ' BBACK OF FRAME.THE INLET GRATE SHALL NOT BE CONTACT CAUSED TO REST MORE THAN 13MM 51 1 ~- AT BACKAT FRONT ABOVE THE INLET FRAME(SEE DETAIL A). --iIFL� AND SIDES CONTACT,I I ALL SIDE4THE FILTER BAG MAY EXTENDTO THE RELEASE) BOTTOM OF THE INLET BOX PROVIDED THE OUTLET PIPE IS UNOBSTRUCTED. MAXIMUM LIP OF GUTTER BAG DEPTH 5 FLOWS SHALL NOT BE ALLOWED TO BYPASS THE BAG.THE BAG OR ITS FRAME SHALL CATCH FLOWS AT ALL SIDES OF THE INLET, EXCEPT AS SHOWN FOR FLOOD RELEASE. DRAINAGE INLET OUTLET PIPE 6 INLET FILTER BAGS SHALL BE INSPECTED WITH FILTER BAG OUTLET PIPE WEEKLY AND AFTER EACH RAINFALL DURING THE WET SEASON AND MONTHLY DURING THE DETAIL A DRY SEASON.SEDIMENT AND DEBRIS SHALL EXISTING DROP 1,3 CM (.5') BE REMOVED BEFORE ACCUMULATIONS HAVE NOTES: INLET GRAT _j I MAXIMUM BAGS SHALL BE REPAIRED OR REPLACED AS G _ SOON AS DAMAGE OCCURS. 1.)SEDIMENT TRAPPED UPSTREAM OF INLET SEDIMENT SEDIMENT CONTROL BMP SHALL BE PLAN VIEW REMOVED WEEKLY AND PRIOR TO A CONTROL RAINFALL EVENT. STORM DRAIN INLET 2.)PLACE BMP'S TIGHTLY TOGETHER AT FILTER B FILTER BAG JOINTS TO PREVENT OR MINIMIZE FRAME EXISTING DROP SEEPAGE AT JOINTS. (OPTIONAL) INLET FRAME IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2105 S WINCHESTER BLVD @omcast DESIGN: REV DESCRIPTION DATE STORM WATER PROTECTION PLAN viii. Section # 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a 0 ISSUE FOR PERMIT 02/28/2013 DRAWN BY: JUR PROJ#: CAM-2105 S WINCHESTER BLVD —BORE—WP e�� I "Permit to Excavate" will be valid For your Dig Alert I.D. # •„r I CALL TOLL FREE APPROVED: CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALIFORNIA DIVISION Y 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE,LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBC SHEET: 6 OF 7 LEGEND • Traffic Cone or Delineator T Sign Direction of Travel W W21-5 20_1 ( Not a pavement marking ) c<9 Flashing Arrow Sign (Where Required) END ROAD SHOULDER WORK WORK Refer to Page 7 of Caltrans manual ROAD WORK AHEAD Type A, Type I , or Type II . 020-2 c9A Y High Level Warning Device (Flagtree) TABLE A I—i Barricade (For Excavation Only) Refer to Page 12 of Caltrans manual APPROCH TAPER NO. OF SPACING OF CONES SIGN SPACING (S) to select for Details on SPEED LENGTH CONES ALONG TAPER ADVANCE OF TAPER Type I Type II or r Type III (L) PER TAPER (FEET) &BETWEEN SIGNS 25 MPH 125 FT. 6 25FT. 150 FT. 30 MPH 180 FT. 7 SOFT. 200 FT. !iiill 35 MPH 245 FT. 8 35FT. 250 FT. Flogger 40 MPH 320 FT. 9 4OFT. 350 FT. 45 MPH 540 FT. 13 45FT. 550 FT. 50 MPH 600 FT. 13 SOFT. 600 FT. 55+MPH 1000 FT. 21 55FT. 1000 FT. NOTES: 1 . Flaggers will be used to control traffic at non—signalized intersections. Flaggers Will use 2 way radios when a 24' (min) roadway cannot be maintained. 2. No Parking/Tow Away signs will be posted 48 hours in advance to clear work zone. 3. All construction zone signs/directional signs will conform to Caltrans specs. PPROVED t� ST RUCTION Signs will be spaced 150 feet apart where applicable. b, . . C mp:I'- � 4. Same traffic control plan will apply at other similar locations and opposite City side of street. — public Works permit N(). 06041.4 5. Use flag trees on all C-18/C-23 signs. Contractor must have those puns on the job site during construction IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2105 S WINCHESTER BLVD @OMCaSt DESIGN: REV DESCRIPTION DATE 2013 TRAFFIC CONTROL NOTES AND SIGNS i Secion4216/4217of heGovernmentCode requires a0 ISSUE FOR PERMIT 02/28/E'� Dig Alert Excavate" Nbmval to be issued bAlere a DRAWN BY: JUR PROJ#: CAM-2105 S WINCHESTER BLVD —BORE—WP ` "Permit to Excavate" will be valid For your Dig Alert I.D. CALL TOLL FREE APPROVED: CONSTRUCTION TYPE: BORE AND PLACE CONDUIT CALIFORNIA DIVISION •• Y 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3055 COMCAST PLACE.LIVERMORE,CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: GNBC SHEET: 7 OF 7