Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENC2013-00103
• Y _ �( � Print Form 3 bROA I Permit No r1�ZJ13'r0C/03 CITY OF CAMPBELL ENCROACHMENT PERMIT DEPT.OF PUBLIC WORKS (for working within the public X-Ref.File 70 North First Street right-of-way) Application Date Campbell,CA 95008 Application Expiration Date Ph. (408)866-2150 Issued APN Fx. (408)376-0958 Permit Expiration Date APPLICATION-Application is hereby made for a Public Works Permit in accordance with Campbell Municipal Code,Section 11.04. (Application expires in six (6) months if the permit is not issued. Application Fee is non-refundable.) C.A.) Work Address or Tract No.: t—1( SV V. Q Utility Trench Location: 0 Nature of Work: JD2t1!>na O . C. Attach four(4)copies of an engineered plan showing the location and extent of the work,and four(4)copies of the preliminary Engineer's Estimate of work. The plans shall show the relation of the proposed work to existing surface and underground improvements.When approved by the City Engineer,said plan becomes a part of this permit. D. All work shall conform to the City of Campbell Standard Specifications and Details for Public Works Construction;the General Permit Conditions listed on the reverse side;and the Special Provisions for this permit,listed below. Failure to abide by these conditions and provisions may result in job shutdown and/or forfeiture of Faithful Performance Sureties and cash deposits. (See General Permit Conditions 1 and 2.) cE. The Contractor must have this permit and approved plans at the site and must notify the Public Works Department at least two days before ___, starting work. Notice must be given to Public Works at least 24 hours before restarting any work. Name of Applicant: ‘7)�u 1 11 ' S Co A Telephone: ![O E._ F..._, , 3 c z Address: V _jr/'ba, E6 -` f _ C. f CA. _6a5 i_. E-Mail Address: S&OA()I p sLD „ 1 Q 6 Ala 24-HOUR EMERGENCY PHONE NUMBER: V Is this work being done by the property owners at their own residence? r YES NO The Applicant/Permittee hereby agrees by affixing their signature to this permit to hold the City of Campbell,i s officers,agents,and employees free,safe and harmless from any claim or demand for damages resulting from the work covered by this permit. The Appl' t/Permittee hereby acknowledge t they have read and understand both the front and back of this permit, and they will inform their co ctor(s) of in tion pp'cant s dvised that upon issuance of this permit, property owner, or property owner's successors, shall be re onsible for any n all da es arisi g ou f the condition of any private improvements in the public right-of-way. Accepted: S" v 3v /'3 (App'cant Permittee) (sign) Date (Contractor) (Print Name) Date SPECIAL PROVISIONS: 1. Street shall not be open cut for underground installations. Minimum cuts may be allowed for connections or exploration holes. Such cuts may be specifically approved by the Inspector prior to cutting. 2. Pavement may be cut for underground installations and must be restored in accordance with the Standard Details Trench Restoration Method "A",unless otherwise approved by the Engineer. 3. Work to be staked by a licensed Land Surveyor or Civil Engineer and two(2)copies of the cut sheets sent to the Public Works Department before starting work. 4. Per Section 4215 of the Government Code this permit is not valid for excavations until Underground Service Alert(USA)has been notified and the inquiry identification number has been entered hereon. USA Phone: 1-800-227-2600. USA TICKET NO. 5. Prior to any work,the property owner shall execute an Agreement for Private Improvements in the Public Right-of-Way,which shall be recorded. 6. Public Notification Requirements: 7. SEE PUBLIC WORKS FEE SCHEDULE FOR CURRENT FEES AMOU T RECEIPT NO. PERMIT APPLICATION FEE $ .00 2 4 74 PLAN CHECK DEPOSIT $ SECURITY FOR FAITHFUL PERFORMANCE/LABOR&MATERIALS $ CONSTRUCTION CASH DEPOSIT $ `L Q PLAN CHECK&INSPECTION FEE $ '3o' 433 EMERGENCY PERMIT FEE $ APPROVED FOR ISSUANCE For City Engineer Date Permit Expires 12 Months After Date of Issuance GENERAL PERMIT CONDITIONS 1. A Construction Cash Deposit is required. Charges will be made against this deposit if there is an emergency call-out,overtime inspection or when City ordered barricading is required. Any such costs in excess of the deposit will be billed to the Permittee. 2. A one-year maintenance period and surety are required. Such period will begin on date of written acceptance by the City. 3. Refund or the cash deposit balance and refund or cancellation of the Faithful Performance Surety will be initiated by the written acceptance of the work by the City. 4. Submit project schedule 10(ten)days prior to proposed start of work.Special provisions may be required for work within City facilities and downtown Campbell. 5. The Permittee must request in writing a final inspection and acceptance of the work upon completion. Acceptance by the City will be made in writing to the Permittee. 6. Maintain safe pedestrian and vehicular crossings and free access to private driveways,bus stops,fire hydrants,and water valves. 7. A Construction Traffic Control Plan and a Construction Schedule are required for all lane closures,detours,and street closures.This plan must be reviewed and approved prior to any lane closures. 8. A Construction Traffic Control Plan shall conform to the Caltrans Manual of Traffic Controls for Construction and Maintenance Work Zones,dated 1990,available at Caltrans.Traffic control equipment shall include Type II flashing arrow signs if required. 9. Replace as directed by the City Engineer any damaged or removed improvements in accordance with City Standards and Specifications at the sole expense of the Permittee. 10. Sawcut for all PCC or AC removals.All PCC removals shall be to the nearest scoremark and shall be doweled to existing improvements. 11. Prior approval of inspector is required for any work done after normal working hours,on weekends or holidays and may require reimbursement of inspection costs at the current overtime rate. 12. Adequate signing and barricading is required on the job site. Failure to provide such signing and barricading may result in the City's providing signing and barricades and charging the cost(including all labor and materials)against the cash deposit. 13. Compaction testing of subgrade,base rock,and asphalt concrete by Permittee is required unless otherwise stated by the City Engineer. 14. The Contractor or Permittee will have a supervisory representative available for contact on the project at all times during construction.Contractor or Permittee shall provide a phone number at which they can be contacted outside the hours of 8:00 a.m.to 4:00 p.m. 15. No storage of materials or equipment will be allowed near the edge of pavement,the traveled way,or within the shoulderline which would create a hazardous condition to the public. 16. This permit shall not be construed as authorization for excavation and grading on private property adjacent to the work or any other work for which a separate permit may be required,nor does it relieve the Permittee of any obligation to obtain any other permit required by law. 17. This permit does not release the Permittee from any liabilities contained in other agreements or contracts with the City and any other public agency. 18. This permit is not transferable.Work must be performed by the Permittee or his designated agent or contractor as specified thereon. 19. Call back(call out)due to emeregencies regarding this permit shall be at the current overtime rate with a three(3)hour minimum charge per occurrence. 20. Pursuant to Chapter 14.02 of the Campbell Municipal Code,applicant shall not cause to be discharged any material into the municipal storm drain system other than storm water. Applicant shall adhere to the BEST MANAGEMENT PRACTICES established by the Santa Clara Valley Urban Runoff Pollution Prevention Program. 21. If the public interest requires a modification of,or a departure from the plans and specifications,the City shall have the authority to require or approve any modification or departure and to specify the manner in which the same is to be made for City-owned or maintained facilities. 22. Permitttee must provide advance notification to all parties that may be affected by the permit activities. Notification shall be reviewed by the City prior to distribution and include dates of work and a contact name and phone number. Applicant shall be responsi. -for nsuring that all those providing services under the applicant are aware and understand all of the above conditions. C )6t. Applicant Date: Contractor (Print Name) Date: J:\FORMS\Templates\Encroachment Permits\Encroachment Permit STATIC form2.pdf Rev.03/13 t 0 1 in m 0 • 3 d . .F I . 0 m cDn° 3 n r a W e ELECRITCAL BOX > ° 3 I m(END JOINT TRENCH) 2 ,,, 1 UTILITY TRENCH CONTAINING • '� GAS, ELEC, CAN, AND TELE. ON-SITE STORM DRAIN W/ OVERFLOW SDI ELECRITCAL BOX MIN. 1' BEHIND WALK >. ' 3 I lv m - - - - P.O.C. GAS n ,J - - - - - - - UT T UT UT UT UT I :;r 15.00 INGRESS/EGRESS SEE SHEET C 1.0 - momm. ® O. FOR CONTINUATION D'• m 3 W m EASEMENT FOR THE NEW WATER METER v 1 BENEFIT OF PARCEL B FOR PARCEL "B" • "' D v •, (n v e 17 W l W W W W w l FIRE SPRINKLER °lq D .: 26'31NIDE DWY BOX 7 .`21 • � } o a Q NEW WATER METER I Q I FOR PARCEL "A" �..�."' 'I• .. . . o w (RELOCATE ONLY FOR • � I • I• L CONSTRUCTION) a° �to. • • 3 = r1 ` O OHE t1J �OHE w OH 1 OHE :1 � � W I EX. WATER METER • W FOR PARCEL "A" O EXISTI\G EXTEN EX. JOINT f V) (n LESIDE\CE pROPE TYTRENC L�RONTAGENG }- I PARCEL A I (NOIN CONTRACT z T a� ovi Z w D 3 cn CI) _ _ — i 'a a w 17" X30" D ELECRITCAL BOX 3 (TYP) yv% i- -F <7,I • i , D 3 n I r . A. DUPLICATE RECEIPT CITY OF CAMPBELL RECVIt BY: CASHIER 01000248433 PAYOLA: DAVID SLOAN TODAY'S DATE: 05/30/13 REGISTER DATE: 05:30/13 TINE: 14:54 DESCRIPTION AMOUNT ENGR 8 SUBDIV FILING F $370.00 CUST ID: 196 SUNNYSIDE AVE ENGR R SUIBDIV FILING F $370.00 COST ID: 196 SUNNYSIDE AVE TOTAL DUE: $740.00 CHECK PAID: $740.00 CHECK NO: 1293 TENDERED: $740.,20 CHANGE: [v 1 PUBLIC WORKS DEPARTMENT UTILITY ENCROACHMENT, TRAFFIC & MISCELLANEOUS RECEIPT Effective July 1, 2012 o� TO: City Clerk / I • PUBLIC WORKS FILE NO. `��"��� 3 PROPERTY ADDRESS L s Please collect& receipt for the following monies: ACCT. ITEM I AMOUNT ENCROACHMENT PERMIT 4722 Utility Encroachment Permit Application Fee $370.00 - R-1 Encroachment Permit N/C Emergency Permits $105.00 Plan Check& Inspection Fee Minimum Charge Per Location $370.00 31-C.00 Conduits/Pipelines up to 500 Feet $2.45/ft Above 500 Linear Feet $1.50/ft ManholesNaults/Etc. $160.00/ea Pole Set/Removal $160.00/ea 4760 Storage Container Permit $150.00 4760 Project Plans&Specifications Project No. 4760 Standard Specifications & Details $1/Pg$15.50/Bk 4760 Engineering Maps&Plans Aerial Plot 24"x 36" $58.00 Aerial Print 8 1/2"x 11" $27.00 Map Research (includes max of two 24"x36"copies) $27.00 Maps and Plans 24"x 36" $13.00 4722 Penalties: Failure to restore public improvements $100/Calendar Day(Muni Code Sec. 11.34.010) 4722 Penalties: Failure to correct unsafe conditions $100/Calendar Day 4722 Work Without Permits 4 Times Applicable Fee TRAFFIC 47281 Traffic Flow Map (Daily Traffic Volumes) $34.00 4728 Signal Timing Information $72.00/Hr 4271 Truck Permits $16.00 per trip 4728 No Parking Signs $1 each or$25/100 MISCELLANEOUS 511.7424 Postage Other(Please Specify) TOTAL 14-Q op NAME OF APPLICANT Q NAME OF PAYOR S& aC � PHONE L -6O7 -Oa IL ADDRESS i ZIP 93 f FOR RECEIVED B CITY CLERK e. ONLY Date r c Receipt# 3 13 JI7 Y OF ;AMP 3ELL Electric Substructure Handout Package ESTIMATOR NATALIE GOLLOB PHONE # 408/725-2072 PROJECT 196 SUNNYSIDE DRIVE ELECTRIC PM 30945323 GAS PM 30944884 DATE 10/11/2012 UNDERGROUND CONSTRUCTION CHECK LIST Residential — Single Family CUSTOMER: DAVID SLOA CONTRACTOR: LOCATION: 196 SUNNYSIDE DRIV PM # 30945323 Explained material and workmanship must meet PG&E standards and be inspected. Deficient material or workmanship must be corrected. Explained the immediate shading of PG&E facilities: manpower, tools, and equipment must be provided by the customer/contractor. Informed to contact Underground Service Alert (USA) at 1-800-227-2600, at least two working days in advance of digging. Explained customer-owned service terminating facilities. Explained the following requirements as shown on the attached PG&E sketch. Trench configuration, locations, depth, and separation requirements. Backfill requirements, minimum cover, rock-free soil, and compaction. The use of conduit in paved and planted (difficult) areas. Conduits size and type specified by PG&E. The above information and attached drawing were discussed with me and understand the requirements for installing facilities for PG&E on the job. CUSTOMER SIGNATURE: DATE: PG&E REPRESENTATIVE: DATE: • APPLICANT CHECKLIST ❑ CONTACT UNDERGROUND SERVICE ALERT 'USA" AT 1-800-227-2600 (OR '811' BY LANDUNE), AT LEAST 2 BUSINESS DAYS BEFORE EXCAVATION, TO HAVE EXISTING UNDERGROUND UTILITIES MARKED IN FIELD D OBTAIN CITY/COUNTY EXCAVATION PERMIT (IF APPLICANT TO TRENCH) ❑ FOLLOW TRENCH INSTRUCTIONS (IF APPLICANT TO TRENCH) O THE TOTAL NUMBER OF SWEEPS (BENDS) IN ANY ONE CONDUIT RUN NOT TO EXCEED 300', INCLUDING THE SWEEP AT THE FLED-IN LOCATION. ❑ MAINTAIN 3' MINIMUM PARALLEL SEPARATION FROM WET FACILITIES (I.E. WATER, SEWER, STORM), RD-ER TO UO STANDARD S5453, EXHIBIT B O HAVE SUFFICIENT SAND ONSITE PRIOR TO FINAL INSPECTION, REFHR TO GREENBOOK SECTION 2.3.4 ❑ COORDINATE INSTALLATION OF TELEPHONE AND CABLE TV FACILITIES PER THEIR CONSTRUCTION REQUIREMENTS O CALL (408) 725-2202 OR FAX (408) 725-7773 FOR PG&E TRENCH INSPECTION - AT LEAST 2 BUSINESS DAYS ADVANCE NOTICE ❑ PLUMB GAS HOUSELINE TO NEW LOCATION AND HAVE MUNICIPALITY NOTIFY PG&E THAT GAS HOUSEUNE HAS PASSED INSPECTION ❑ GAS MLILR GUARDS PER GAS STANDARDS AND SPECIFICATIONS MANUAL SECTION J-95 ❑ PAYMENT MUST BE RECEIVED BY PG&E, BEFORE CONSTRUCTION WORK CAN BE SCHEDULED TYPICAL JOINT GAS TYPICAL N Y TRENCH SERVICE TRENCH MINIMUM SEPARATION AND F-- 18' MIN -I I- 12° MINI CLEARANCE REQUIREMENTS / GTTCSP MINIMUM COVER m G GAS — 12' 12' 12' 6' 12° 24'; 30" in street m to i T TELEPHONE 12' — 1' 1' 12' 12' 24'; 30' in street m o TELEPHONE (DB) 12' 1' — 1' 12' 12' 24'; 30' in street M .T C M 6° SAND =o C CAT/ 12' 1' 1' — 12' 12° 24'; 30° in street N (OVER c' S ELECTRIC SECONDARY 6° 12' 12' 12' — 3° 24'; 30' in street © N' P ELECTRIC PRIMARY 12' 12' 12' 12' 3' — 30'; 36° in street BEDDING MATERIAL G.; SL STREETLIGHT 6' 12' 12' 12' 1' 3' 24'; 30' in street S ---6' MIN G BEDDING MATERIAL PER UO STANDARD S5453, EXHIBIT B ,--Electric Meter Electric Meter O - \O Consult the PG&E GreenBook for further information. 12'Min. to OutsideI 36 Minimum Building Corner 30'Min. to 36• Minimum ) (www.pge.com/greenbook) I From Center of 6'Min. to Inside Building Corner From Center of No buildin9 vent or Riser to Edge Building Corner Gas House Line to 75" Max. of Panels Meter Edge of Panels opening window within 66' Preferred Applicants 36 of the Gas Regulator 4t3' Min. ouseline Applicant's Vent unless over 10' Gas Regulator Gas Regulator ouseline above the Regulator Vent Vent o VTent ,% O Communications Enclosuni ations �f,1 0, Enclosures No sourc of ignition within 36" of the Gas ri Eli`— 26° — ■ 26' Regulator Vent (including I I 9"Min. Gas } 12' Electric Meter panels) 9'Min.l I \L..36' r' Finish I Meter 111 Typ. Min. I Finish Grade 36" Grade *Gas Valve must be 9" Min. above finish grade and I —2-ji \ r Location of the Building Vent \ r Openings Must be Below the P / 9" out from the finished I wall Gas Riser Level of the Gas Regulator Gas Riser Electric Service Raceway Vent Termination. Electric Service Raceway Meter Set Separation Dimensions and Clearances ADE: Applicant Trenching Checklist CO: SUPV: PPNOTIF: REP: OTHER: PLNR: SHT: SHEETS SCALE:T DATE: PM:I PACIFIC GAS AND ELECTRIC COMPANY 1 c 2012 SUNNYSIDE DR PROPERLY LINE FACE OF CURB H to - TAP HOLE J 4' X 4' X 18" UNDER GAS PIPE Q -- FACE OF CURB TIED-,G" c c c 2" HP .1,C1969 TIED PROPERTY LINE Z L 190 SUNNYSIDE DR P► -.15'PUE L 196 SUNNYSIDE DR NOTES: * BUILDING CONTRACTOR TO TRENCH AND BACKFILL ALL. * BUILDING CONTRACTOR TO DIG GAS TAP HOLE AS SHOWN 4' X 4' X 18" UNDER GAS MAIN * BUILDING CONTRACTOR TO TRENCH APPROX. 100' TO GAS METER LOCATION * PG&E TO INSTALL PIPE * SEE ELECTRIC SUBSTRUCTURE PACKAGE FOR ELECTRIC TRENCH ` SAFETY PM 30944884 MAP 3412-15 CPA 3412-27 MAW 60 PSIG CAMPBELL EST: John Gambucci CO: ADE: John Gambucci Gas Construction Drawing SD: SUPV: Danny Miller 196 Sunnyside Dr, Campbell MOTIF: 106138820 REP: Rachel F. McMillan OTHER: PLNR: Applicant Copy---PG&E Inspector Copy SHT: SHEETS SCALE: DATE: PACIFIC GAS AND ELECTRIC COMPANY PM: REV. 30944884 1 =4D 09/26/12 _ _ __ 7939-8837/\50 25 55'PT6165-H 50'PT6165 4 3-1/0 TAC 7958-8835i \ _ _ _ _ _ 3 1/0 TAC _ _ -0- --lbw- CONTACT NUMBER: ,F� Y N W 3��i ,\ 2 4AR 12KV 2-4AR 12KV DAVID SLOAN O A NSOFFN PUNE w 18 0' 200' (40 8) 889-3052 ALWAYS PUT SAFETY FIRST. _ I LOOK FOR AND ACT TO N RESOLVE UNSAFE SITUATIONS. SUNNYSIDE I ' I HELP AND ENCOURAGE AVENUE �, OTHERS TO ACT SAFELY C> �J Q N_ _ LO , 200' TO FIRST STREET LC) 'v "' IN L LsJ ' F— 2 I. O D O � _ U (n Z O N 0_8801 ( 1 > Z I m COORDINATE # a_ APPLICANT TO IrN SV SV SV SV SV 1 315795828835 O Q INSTALL SPLICE BOX Lk 2 LOADING DISTRICT a CL 3 2 105'/1 1 9' -- k SUMMER COASTAL z TX SIZE - 25 KVA = 0 La a KVA LOAD- 20.6 CO >- 0 # OUST. 3 w = U PHASE 10 o v > MAX ASYM 6784 m c� < U 190 SUNNYSIDE M 202 SUNNYSIDE 0 x Q W EXISTING RESIDENCE 0 EXISTING RESIDENCE > CL w J I a ', I '— CI (-.) III O W I-4 � > I-- 70724'/104' a —I Z c 7 = QV) Q Z V) CO J LEGEND U E-4Z c' w — -- co < INSTALL DESCRIPTION Q M C.-- O Q Sv PG&E TO INSTALL 4/0 AXLP 600V TRIPLEX UG SERVICE CABLE I C-..) U U IN APPLICANT INSTALLED 3" DUCT N NT PG&E TO INSTALL NEW ELECTRIC METER N �n Q [zJ APPLICANT TO INSTALL 17"X30"X30" FVT SPLICE BOX .- CL - 4 120/240V 3W #206 w DEM 10.8 KVA (SC) VD 3.6V IF. VF 5.3V o 196 SUNNYSIDE 2041 SQ FT PROJECT CONDITIONS STAMP o Z 3TON A/C Type(s) of Work: n I-- )( New Business —1 Q 0 PG&E Mointenonce & Construction r=1 U Project Conditions: M ❑X NONE APPARENT (if project design changes,=mod ADE) BLOCK MAP 11 16 16 J NOTES TO JOB: 0 CONDm0NS APPLY: EL PATIO I 114; BANK 3 N u-) <o Cr = 1. PG&E TO INSTALL 4/0A IPX UG SVC FROM BOX TO 200A MSS. ❑PERMITS ❑TAILBOARD ❑OTHER SSD; FUSE 12951 Q oN (Provide additional information on line dos) CLASS 3 VOLTAGE AREA z C C I I 2.APPLICANT TO TRENCH AND INSTALL SUBSTRUCTURES. L_,i 3. JT=E,G,T,CATV INSULATION DIST "B" 6Y, SIGNATURE.NAME,[CORPORATE D).DAIS CAMPBELL () '' = w -I U LiJ Q (n CY a_ (n NOTIFIED U.S.A. Underground Service Alert IMPORTANT! > W TICKET j s•-+�ky CONTRACTOR, ELECTRICAL CONTRACTOR W - BY: w�wA� ♦1 Before Beginning Substructure Work Please Contact w Call: TOLL FREE PG&E Underground Trench Inspector at least two = SUNNYSIDE AVENUE T 7 Y T ,/�, 1-800-227-2600 business f days prior aft inspection. N r/\1 V _\ U Request for inspections received after 12:OOPM will not be inspected until the 3rd working day. VD o 200' Call at (408) 725-2202 N TO FIRST STREET TWO WORKING DAYS BEFORE YOU DIG •-- Li) (WORK NOT PROPERLY INSPECTED, MAY BE REJECTED.) M �- 0 O O LI soot=- z � U V) Z © V) O NOTES >- z APPLICANT TO c� D D D D D ExLSTING PG&E 1. APPLICANT TO TRENCH JOINT WITH ELEC, GAS, TELCO AND CATV Q INSTAL SPLICE BOX 105' 'SEE DEFNL' 1 2 I SPLICE BOX 2. APPLICANT IS TO PROVIDE ALL ELECTRIC SUBSTRUCTURES AS SHOWN 0 3. APPLICANT IS TO PROVIDE MANDREL AND PERFORM MANDREL TEST WITH PG&E INSPECTOR STANDBY > 0 0 4. THE TOTAL NUMBER OF SWEEPS INSTALLED IN ANY DUCT RUN SHALL U NOT EXCEED 300 DEGREES INCLUDING THE SWEEP AT FEED IN LOCATION LO U Cr 5. APPLICANT IS RESPONSIBLE TO ENSURE TRENCHING AND SUBSTRUCTURE r < U Z 190 SUNNYSIDE 202 SUNNYSIDE INSTALLATION MEET PG&E GREENBOOK STANDARDS. GREENBOOKS ARE Q Q W EXISTING RESIDENCE EXISTING RESIDENCE AVAILABLE AT YOUR LOCAL PG&E HEADQUARTERS OR CAN BE FOUND w p 0 U ON THE INTERNET ® WWW.PGE.COM/GREENBOOK Li 94' 0 Q APPLICANT IS RESPONSIBLE TO COORDINATE WITH TELCO AND CATV c, z i- 6. n FOR THEIR CONSTRUCTION REQUIREMENTS >,.. Cr) ..,:c Q:� I:14 co J Q� W UD '- m Q Q CY-3 C.) U SPLICE BOX DETAIL EXIS11NG UG CABLE TO RISER NEW UG SERVICE TO MINIMUM RADIUS BENDS U • 196 SUNNYISIDE -- O 0 O EXISTING UG SVC 3" SERVICE CONDUIT LGI36"-R HORIZONTAL, 24"-R VERTICAL y PROPOSED ELEC L SPLICE BOX r oo #2 MINIMUM AND MAXIMUM COVER µLItR LOCATION SVC. R OO 3" SERVICE CONDUITIW-,. Nt I # 2 C) PRIVATE PROPERTY = 24" MIN FRANCHISE = 30" MIN 196 SUNNYSIDE EXISTING UG SVC 200A MSS -- - - - - � 120/240V 3W o AF 2041 SO FT 3TON A/C �'-I �WIN R sa=10,000A LEGEND S a -- I ALWAYS PUT SAFELY FIRST I LOOK FOR AND ACT T T0. INSTALL DESCRIPTION BLOCK MAP HI 6 16 _, RESOLVE UNSAFE SITUATIONS HELP AND ENCOURAGE EL PATIO 1114; BANK 3 ,.. OTHERS TO ACT SAFELY - D APPLICANT - INSTALL (I)-3" DB 120 PVC CONDUIT 550; FUSE 1295 I CD <-)u-, m � Q o CLASS 3 VOLTAGE AREA z oc o c II RI [2] APPLICANT - INSTALL 1 7"X30"X30" FULL TRAFFIC BOX INSULATION DIST "B" w ____ ___ CAMPBELL c) il = w 64 Z cam.) � W Q V) CC O V)