Loading...
Tank - Denied - 2004 0' . CA1t ..: 1>& i-. '" o j: CAMPBELL " , 0;' (JI/CH 1\\1.0 CITY OF CAMPBELL 'v Community Development Department February 6, 2004 Mr. Danny Sullivan VBS Industries, Inc. 599 B McGlincy Lane Campbell, CA 95008 Re: Preliminary Application Comments File No.: PRE2004-03 - 599 B McGlincy Lane Dear Mr.Sullivan: Thank you for your submittal of a preliminary application for the installation of a liquid nitrogen tank and enclosure adjacent to an existing industrial building located at 599 McGlincy Lane. The subject property is presently zoned M-l-S (Light lndustrial) and is designated as Light Industrial on the City's General Plan Land Use Map. The proposed project would require approval of a Modification to a Site and Architectural Review Permit to allow this installation. The Site and Architectural Review Permit approves the site plan, elevations, and floor plans for the subject property. The Community Development Department is not supportive of the construction of an exterior enclosure to accommodate this tank and would recommend that the tank be accommodated within the interior of the building. An interior installation will require Building Division and Fire Department review only, except for the screening of roof mounted equipment and venting. Your application was distributed to the Public Works Department, Building Division, Planning Division, and County Fire Department. In addition to the Planning Division's comments contained in this letter, please find enclosed comments from the Building Division and County Fire Department. Please note that these comments are meant to be preliminary. Conditions of approval from each department will be developed when the formal application is submitted. You may contact me at (408) 866-2144 or via email at timh@citvofcamobell.com to schedule a meeting to discuss these comments or the application process. ~o/- Tim Haley Associate Planner encl: Building Division Comments, 1/21/04 Fire Department Comments, 2/4104 cc: Geoff Bradley, Senior Planner Arthur R. Burton, 879 McGlincy Lane, Campbell, CA 95008 70 North First Street CIlT1phelL California 9500S-l4 ~6 III 408.H6fi.'2 I 40 l'I\X 408.871. ') I 40 TI)I) 408.866.'2790 CITY OF CAMPBELL BUILDING INSPECTION DIVISION - COMMENTS TO THE DEVELOPMENT REVIEW COMMITTEE DRC: January 21,2004 ADDRESS: 599 McGlincy Lane Project Application: PRE-2004-00003 RECOMMENDATION: Note: No building code issue has been reviewed at Development Review Committee; it will be reviewed in the Building Permit process. Please be aware that building codes are changing constantly; plans submitted for building permit shall comply with the code in effect at that time. Submit permit application together with required documents to the Building Inspection Division to obtain a building permit. No construction can be commenced without an appropriate building permit. It is recommended that this item be forwarded to the Planning Commission for review, with the following conditions. TO THE SA TISF ACTION OF THE BUILDING DIVISION MANAGER/BUILDING OFFICIAL: I. PERMITS REQUIRED: A building permit application shall be required for the proposed installation of the new nitrogen tank system in the (e) commercial structure. The building permit shall include Electrical/Plumbing/Mechanical fees when such work is part of the permit. 2. CONSTRUCTION PLANS: The conditions of Approval shall be stated in full on the cover sheet of construction plans submitted for building permit. 3. SIZE OF PLANS: The minimum size of construction plans submitted for building permits shall be 24 in. X 36 in. 4. PLAN PREPARATION: This project requires plans prepared under the direction and oversight of a California licensed Engineer, Architect or Licensed Mechanical Contractor doing the installation. Plans submitted for building permits shall be "wet stamped" and signed by the qualifYing professional person. 5. SITE PLAN: Application for building permit shall include a competent site plan that identifies property and proposed structures with dimensions and elevations as appropriate. Site address and parcel numbers shall also be clearly called out. Site parking and path of travel to public sidewalks shall be detailed. J:\Building ORC Comments\599mcglincylnyre.doc 6. SPECIAL INSPECTIONS: When a special inspection is required by U.B.C. Section 1701, the architect or engineer of record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the building permits, in accordance with U.B.C Section 106.3.5. Please obtain City of Campbell, Special Inspection forms from the Building Inspection Division Counter. 7. The City of Campbell, standard Santa Clara Valley Non-point Source Pollution Control Program specification sheet shall be part of plan submittal. The specification sheet (size 24" X 36") is available at the Building Division service counter. 8. TITLE 24 ACCESSIBILITY - COMMERCIAL: On site general path of travel shall comply with the latest California Title 24 Accessibility Standards. Work shall include but not be limited to accessibility to building entrances from parking facilities and sidewalks. 9. TITLE 24 ACCESSIBILITY - COMMERCIAL: Projects seeking to use the Title 24 Hardship exemption clause shall blue-line completed, City of Campbell "20%" exemption form on submitted construction plans. Form is available at Building Division service counter. 10. APPROVALS REQUIRED: The project requires the following agency approval prior to issuance ofthe building permit: a. Santa Clara County Fire Department J:\Building DRe Comments\599mcglincylnyre.doc FIRE ...,EPARTMENT SANTA CLARA COUNTY PLAN REVn::W No. 04 0155 BLOG PERMIT No. 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 . (408) 378-9342 (tax) . www.sccfd.org CONTROL No. PLAN REVIEW COMMENTS CODE/SEC. SHEET NO. REQUIREMENT This installation shall comply with the following: 1. 2001 California Fire Code (CFC), as adopted by the City of Campbell, 2. Chapter 17.06 of the Campbell Municipal Code (CMC) DISAPPROVED: Notified by the City of Campbell Planning Department that plans will not be approved as submitted. Please resubmit plans after approval has been granted by the City of Campbell. City PLANS SPECS NEW RMDl AS OCCUPANCY CONST. TYPE I APOl'oanlName OAT< PAGE CBL 0 0 0 0 0 Danny Sullivan 2/4/2004 1 1 -OF SECJFLOQR AREA LOAD DESCRIPTION BY AG HazMat Installation Baker. Richard NAME OF PROJECT VBS INDUSTRIES I LOCAT'ON 599 Mcglincey Ln Organized as the Santa Clara County Central Fire Protec~i~n[)~stri~_ ____u_ ___.0 Serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los GItos, Monte Sereno, Morgan Hill, and Saratoga Pre-Application Written Description - Proposed Use This tank will be used to supply LN2 to specified work areas throughout the building. - Square Footage We will be adding approximately a 6' x 6' chain link fence that will be attached to the existing outside storage facility. This will be temporary until we vacate facility. - Number of employees 9 total employees at 5998 McGlincy Ave. - Hours of Operation 5:00 am to 5:00 pm Monday thru Friday - Adjacent Uses Twin Glass Technology - 599A McGlincy Ave. Residence - 607 McGlincy Ave. , i i ! ~~.o~. C'i1l1/.l~ !::: ~ u ,... o 0 '"' >. $ " (' ,-' . ORCH ,,'1..:0. File No. ~ .10t71 ~ tJ Y. 711 n~6.t..I" d Pre-Application Review I ({~( d1 Application Planning Division - 70 North First Street, Campbell, California 95008 ~ (408) 866.2140 APN(S): ZONING: PROPERTY ADDRESS: 5118 TYPE OF APPLICATlONd..JJ2- 412-30-041 DATE Fll..ED: GENERAL PLAN: WlJl.ltH~ AV~ I Mt'\P~L.L.I Ur .,..." 1500l-! 4D{)~"wJtt. - Ovr~IDE- IJJsrJ\1...L.A-nON.. APPLICANT: DANklY hJU-Illitl4 - vas 1Nl>li~nl.l~.sj IAu. ADDRESS: ~ ItIC6L..IIll.c'/ ,+v~. TELEPHONE: (ilYJ) ~7J (j}..#f I CITY/STATE: I1Mp~) & ZIP:. CELL ~"'3~~7 EMAll..:~i1ny@vbsfle)'. FAXNUMBER:~)3715t15" &m PROPERTY OWNER: Arthur R. Burton ADDRESS: 879 McGlincey CITY/STATE: Campbell, Ca 95008 TELEPHONE: (408- 377-4280 ZIP: 95008 AFFIDA VITfSIGNATURE(S): The undersigned person(s), having an interest in the above-described property, herehy make . application in accordance with the provisions of the Campbell Municipal Code; and, hereb certif)l e information given herein is true and correct to the best of my/our knowle ge nd beli \I 1.2.. D Dte QJL ~.U Nc" 13, ,<,0<1 J Property Owner's Signature Date The proposed exterior storage of the LN 2 tank, in a steel chain link fenced area, (a tenant improvementl is acceptable and approved by the owner. owner: Arthur R. Burton a8 Rvsd,9/22/03 .