Loading...
Site & Arch - Lot 2 - 2005April 6, 2005 Ms. Sukkin Fong 13132 Delson Court Los Altos, CA 94022 Re: Building Permit No: BLD2005-444 1141 San Tomas Aquino Road (Parcel 2) Dear Ms. Fong: The Planning Division has reviewed your plan submittal for a new single-family home located at the above referenced address. Per Planning Commission Resolution No. 3638 the following conditions of approval/issues need to be addressed prior to the issuance of a building permit: 1. Final Parcel Map: The Site and Architectural Review Permit approval is contingent upon recordation of the Final Parcel Map to divi~e the subject property. The Final Parcel Map shall be recorded prior to the issuance of building permits. 2. Park Impact Fee: A park impact fee, based on a density range of less than six units per gross acre, is due upon development of the site. Credit shall be given for any existing single-family residence to be demolished. Prior to recordation of the Parcel Map, 75% of this fee is due. The remaining 25% is due prior to issuance of a certificate of building occupancy. 3. Fences: Any existing or new fencing shall comply with Section 21.18.060 of the Campbell Municipal Code. Fencing along the property lines shall be replaced with a six-foot high "good neighbor" wood fence by the applicant, unless it is determined to be in good condition by the Community Development Director. Indicate the location, type and material for any new fences on the plans. 4. Exterior Building Colors: The applicant shall submit a revised color/material board to the Planning Division, prior to the issuance of building permits, which depicts a modified exterior building color from the proposed pink/peach color to an earth tone color. The proposed colors shall be subject to review and approval by the Community Development Director. 5. Parking and Driveways: The applicant shall provide a decorative paving treatment within the driveway for the home. The design and materials used for the decorative pavement shall be indicated on the building permit plans and shall be reviewed and approved by the Community Development Director prior to the issuance of building permits. 70 North First Street. Campbell, California 95008-1436 . TEL 408.866.2140 . FAX 408.871.5140 . TOD 408.866.2790 Building Permit No: BLD2\. r444 1141 San Tomas Aquino Road (Parcel 2) Page 2 of2 6. Tree Protection Plan: The applicant shall submit a tree protection plan for the protected trees to be retained on site and shall contain specific information about the preservation of the trees during any grading or building on site. The tree protection plan shall be submitted to the Planning Division for review and approval by the Community Development Director prior to the issuance of building permits. Such tree protection measures shall be installed prior to any demolition, grading, or building on the project site. No construction or trenching shall take place within the drip line of trees and a fence constructed of temporary cyclone fencing or wire mesh securely attached to poles driven into the ground shall be installed around the dripline of the tree. All trimming or branch removal from protected trees shall be completed by a certified arborist. 7. Utilities: All new on-site utilities shall be installed underground per section 21.18.140 of the Campbell Municipal Code. Please indicate on the plans that all the utilities will be undergrounded. 8. Contractor Contact Information Posting: Prior to the issuance of building permits, the project site shall be posted with the name and contact number of the lead contractor in a location visible from the public street. 9. Wood Trellis: The front elevation on Sheet A-4 lists a new wood trellis. Please depict the location and design of this wood trellis on the elevation. Thank you for the opportunity to review these plans. If you should have any questions regarding these comments or the requested information, please feel free to contact me at (408) 866-2193 or by email atstephaniew@cityofcampbell.com. . Sincerely, Stephanie Willsey Planner I cc: Frank Mills, Senior Building Inspector GeoffBradley, Senior Planner March 23,2005 Ms. Sukkin Fong 13132 Delson Court Los Altos, CA 94022 Re: PLN2005-05-l141 S. San Tomas Aquino Road (Parcel 2) Site and Architectural Review Permit Dear Applicant: Please be advised that at its meeting of March 22, 2005, the Planning Commission adopted Resolution No. 3638 approving a Site and Architectural Review Permit (PLN2005-05) to allow the construction of a new single-family residence on the above referenced property. This action is effective in ten calendar days, unless appealed in writing to the City Clerk by 5 p.m. on Friday, April 1, 2005. The time within which judicial review of this action must be sought is governed by Section 1094.6 of the California Code of Civil Procedure, unless another statute (such as California Government Code Section 65009 or some other applicable provision) sets forth a more specific time period. If you have any questions, please do not hesitate to contact me at (408) 866-2140. Sincerely, 9YtephlL~ L0 \ ~ Stephanie Willsey Planner I Cc: Ed Arango, Public Works Frank Mills, Building Chris Veargason, County Fire 70 North First Street . Campbell, California 95008-1436 . TEL 408.866.2140 . FAX 408.871.5140 . TOD 408.866.2790 RESOLUTION NO. 3638 BEING A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF CAMPBELL GRANTING A SITE AND ARCHITECTURAL REVIEW PERMIT (PLN2005-05) TO ALLOW THE CONSTRUCTION OF A NEW TWO-STORY SINGLE-FAMILY RESIDENCE ON PROPERTY OWNED BY MS. SUKKIN FONG LOCATED AT 1141 S. SAN TOMAS AQUINO ROAD (PARCEL 2) IN AN R-I-9 (SINGLE FAMILY RESIDENTIAL) ZONING DISTRICT. APPLICATION OF MS. SUKKIN FONG. FILE NO. PLN2005-05. After notification and public hearing, as specified by law and after presentation by the Community Development Director, proponents and opponents, the hearing was closed. After due consideration of all evidence presented, the Planning Commission did find as follows with respect to application PLN2005-05: 1. The density of the proposed project will result in a density of 3.7 units per gross acre, which is consistent with the General Plan land use designation of Low Density Residential (less than 4.5 units per gross acre). 2. The proposed project is consistent with the R-1-9 (Single-Family Residential, 9,000 square foot minimum lot size) zoning district and meets the minimum setbacks, height restriction, building coverage, floor area ratio, and parking requirements of the R-I-9 Zoning District. 3. The project is consistent with the development standards and design guidelines of the San Tomas Area Neighborhood Plan. 4. The proposed home on Parcel 2 consists of a new 4,255 square foot, two-story single-family residence with a building coverage of28% and Floor Area of 0.42. 5. The height of the proposed home is 26 feet, 2 inches where the maximum height limit is 28 feet. 6. The front of the house faces Turner Way to provide consistency with the other homes along Turner Way and takes vehicular access from a private driveway from South San Tomas Aquino Road. 7. The proposed project is surrounded by single-family residential uses on all sides. 8. The project provides three covered and three uncovered parking spaces where a minimum of one covered and one uncovered parking space are required. 9. The applicant is not proposing to remove any protected trees. There is one mature tree on site that is a protected tree under the City's Tree Protection Ordinance and is being incorporated into the site design and layout. Planning Commission Resc,. -ion No. 3638 PLN2005-05 -1141 S. San Tomas Aquino Road - New Single-Family Residence (Parcel 2) Page 2 10. The project qualifies as a Categorically Exempt project per Section 15303, Class 3, of the California Environmental Quality Act (CEQA). Based upon the foregoing findings of fact, the Planning Commission further finds and concludes that: 1. The proposed project is consistent with the City of Campbell General Plan and Zoning Ordinance. 2. The proposed project, as conditioned, will aid m the harmonious development of the immediate area. 3. The proposed project is well designed and is architecturally compatible with the surrounding neighborhood. 4. No substantial evidence has been presented from which a reasonable argument could be made that shows that the project, as currently presented and subject to the required conditions of approval, will have a significant adverse impact on the environment. 5. The proposed development will not be detrimental to the health, safety or welfare of the neighborhood or the City as a whole. 6. The proposed project will contribute to the housing stock in the City of Campbell and serve the housing needs of the community. 7. There is a reasonable relationship between the use of the fees imposed upon the project and the type of development project. 8. There is a reasonable relationship and a rough proportionality between the conditions of approval and the impacts of the project. NOW, THEREFORE, BE IT RESOLVED that the Planning Commission approves a Site and Architectural Review Permit (PLN2005-05) to allow the construction of a new two-story single- family residence on property owned by Ms. Sukkin Fong located at 1141 S. San Tomas Aquino Road (Parcel 2) in an R-I-9 (Single Family Residential) Zoning District, subject to the following conditions: Where approval by the Director of Community Development, City Engineer, Public Works Director, City Attorney or Fire Department is required, that review shall be for compliance with all applicable conditions of approval, adopted policies and guidelines, ordinances, laws and regulations and accepted engineering practices for the item under review. Additionally, the applicant is hereby notified that he/she is required to comply with all applicable Codes or Ordinances of the City of Campbell and the State of California that pertain to this development and are not herein specified. Planning Commission Resc, .Ion No. 3638 PLN2005-05 -1141 S. San Tomas Aquino Road - New Single-Family Residence (Parcel 2) Page 3 COMMUNITY DEVELOPMENT DEPARTMENT Plannin!! Division: 1. Approved Proiect: Approval is granted for a Site and Architectural Review Permit (PLN2005-05) to allow the construction of a new two story single-family residence located at 1141 S. San Tomas Aquino Road (Parcel 2). The building design and site design shall substantially conform to the project exhibits listed below, except as may be modified by the conditions of approval herein: a. Project plans stamped as received by the Planning Division on February 15, 2005 including a site plan, floor plans, elevations, and a landscape plan. b. Color/material board stamped as received by the Planning Division on February 15, 2005. c. Colored elevations stamped as received by the Planning Division on February 15, 2005. 2. Approval Expiration: The Site and Architectural Review Permit approval shall be valid for a period of one year from the date of final approval. Within this one-year period, a building permit must be obtained and construction completed one year thereafter or the Site and Architectural Review Permit shall be void. 3. Fences: Any existing or new fencing shall comply with Section 21.18.060 of the Campbell Municipal Code. Fencing along the property lines shall be replaced with a six-foot high "good neighbor" wood fence by the applicant, unless it is determined to be in good condition by the Community Development Director. 4. Property Maintenance: The property is to be maintained free of any combustible trash, debris and weeds until the time that actual construction commences. All existing structures shall be secured by having windows boarded up and doors sealed shut, or demolished or removed from the property. 5. Parking and Driveways: a. All parking and driveway areas shall be developed in compliance with the approved plans and Chapter 21.28 (parking and Loading) of the Campbell Municipal Code. b. The applicant shall provide a decorative paving treatment within the driveway for the home. The design and materials used for the decorative pavement shall be indicated on the building permit plans and shall be reviewed and approved by the Community Development Director prior to the issuance of building permits. 6. Final Parcel Map: The Site and Architectural Review Permit approval is contingent upon recordation of the Final Parcel Map to divide the subject property. The Final Parcel Map shall be recorded prior to the issuance of building permits. Planning Commission Reso. .Ion No. 3638 PLN2005-05 -1141 S. San Tomas Aquino Road - New Single-Family Residence (Parcel 2) Page 4 7. Exterior Building Colors: The applicant shall submit a revised color/material board to the Planning Division, prior to the issuance of building permits, which depicts a modified exterior building color from the proposed pink/peach color to an earth tone color. The proposed colors shall be subject to review and approval by the Community Development Director. 8. Park Impact Fee: A park impact fee, based on a density range of less than six units per gross acre, is due upon development of the site. Credit shall be given for any existing single- family residence to be demolished. Prior to recordation of the Parcel Map, 75% of this fee is due. The remaining 25% is due prior to issuance of a certificate of building occupancy. 9. Landscape Plan: The applicant shall submit a final landscape and irrigation plan to the Planning Division, prior to the issuance of building permits, for review and approval by the Community Development Director. The required trees and landscaping shall be installed prior to the issuance of a Certificate of Building Occupancy. The landscape and irrigation plan shall substantially conform with the approved conceptual landscape plan and the City's Water Efficient Landscaping Standards (WELS) and shall include the following: a. A minimum of five trees on Parcel 2. b. Landscaping in the front yard area of the home. 10. Tree Protection Plan: The applicant shall submit a tree protection plan for the protected trees to be retained on site and shall contain specific information about the preservation of the trees during any grading or building on site. The tree protection plan shall be submitted to the Planning Division for review and approval by the Community Development Director prior to the issuance of building permits. Such tree protection measures shall be installed prior to any demolition, grading, or building on the project site. No construction or trenching shall take place within the drip line of trees and a fence constructed of temporary cyclone fencing or wire mesh securely attached to poles driven into the ground shall be installed around the drip line of the tree. All trimming or branch removal from protected trees shall be completed by a certified arborist. 11. Utilities: All new on-site utilities shall be installed underground per section 21.18.140 of the Campbell Municipal Code. 12. On-Site Lighting: On-site lighting shall be shielded away from adjacent properties and directed on site. The design and type of lighting fixtures and lighting intensity of any proposed exterior lighting for the project shall be reviewed and approved by the Community Development Director prior to installation of the lighting for compliance with all applicable Conditions of Approval, ordinances, laws and regulations. Lighting fixtures shall be of a decorative design to be compatible with the residential development and shall incorporate energy saving features. Planning Commission ReSOL.lon No. 3638 PLN2005-05 -1141 S. San Tomas Aquino Road - New Single-Family Residence (Parcel 2) Page 5 13. Construction Hours: Construction activities shall be limited to the hours of 8:00 a.m. to 5:00 p.m. weekdays and 9:00 a.m. to 4:00 p.m. Saturdays. Construction is prohibited on Sundays and Holidays unless an exception is granted by the Building Official. 14. Contractor Contact Information Posting: The project site shall be posted with the name and contact number of the lead contractor in a location visible from the public street prior to the issuance of building permits. Buildin2 Division: 15. Permits Required: A building permit application shall be required for the proposed new dwelling structure. The building permit shall include Electrical/Plumbing/Mechanical fees when such work is part of the permit. 16. Construction Plans: The conditions of approval shall be stated in full on the cover sheet of construction plans submitted for building permit. 17. Size of Plans: The size of construction plans submitted for building permits shall be 24 inches by 36 inches. 18. Plan Preparation: This project requires plans prepared under the direction and oversight of a California licensed Engineer or Architect. Plans submitted for building permits shall be "wet stamped" and signed by the qualifying professional person. 19. Soils Revort: The applicant shall submit two copies of a current soils report containing foundation and retaining wall design recommendations, prepared to the satisfaction of the Building Official, with the building permit application. This report shall be prepared by a licensed engineer specializing in soils mechanics. 20. Site Plan: Application for building permit shall include a competent site plan that identifies property and proposed structures with dimensions and elevations as appropriate. Site plan shall also include site drainage details. 21. Foundation Inspection: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project building inspector upon foundation inspection. This certificate shall certify compliance with the recommendations as specified in the soils report and the building pad elevation and on-site retaining wall locations and elevations are prepared according to approved. Plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered civil engineer for the following items: a. pad elevation b. finish floor elevation (first floor) c. foundation comer locations Planning Commission Reso._.lOn No. 3638 PLN2005-05 -1141 S. San Tomas Aquino Road - New Single-Family Residence (Parcel 2) Page 6 22. Title 24 Energy Compliance: California Title 24 Energy Compliance forms CF-IR and MF- lR shall be blue-lined on the construction plans. 8% X 11 calculations shall be submitted as well. 23. Special Inspections: When a special inspection is required by U.B.C. Section 1701, the architect or engineer of record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the building permits, in accordance with U.B.C Section 106.3.5. Please obtain City of Campbell, Special Inspection forms from the Building Inspection Division Counter. 24. Non-Point Source Pollution Control: The City of Campbell standard Santa Clara Valley Non-point Source Pollution Control Program specification sheet shall be part of plan submittal. The specification sheet (size 24 inches by 36 inches) is available at the Building Division service counter. 25. P.G.&E.: The applicant is advised to contact P.G.&E. as early as possible in the approval process. Service installations, changes and/or relocations may require substantial scheduling time and can cause significant delays in the approval process. The applicant should also consult with P.G.&E. concerning utility easements, distribution pole locations and required conductor clearances. 26. Construction Fencing: This project shall be properly enclosed with construction fencing to prevent unauthorized access to the site during construction. The construction site shall be secured to prevent vandalism and/or theft during hours when no work is being done. All protected trees shall be fenced to prevent damage to root systems. 27. Proiect Approvals: The project requires the following agency approval prior to issuance of the building permit: a. West Valley Sanitation District (378-2407) b. Santa Clara County Fire Department (378-4010) c. Bay Area Air Quality Management District (Demolitions Only) c. School District: i. Campbell Union School District (378-3405) ii. Campbell Union High School District (371-0960) Hi. Moreland School District (379-1370) iv. Cambrian School District (377-2103) Note: To determine your district, contact the offices identified above. Obtain the School District payment form from the City Building Division, after the Division has approved the building permit application. Planning Commission Reso.__.iOn No. 3638 PLN2005-05 -1141 S. San Tomas Aquino Road - New Single-Family Residence (parcel 2) Page 7 PUBLIC WORKS DEPARTMENT 28. Parcel Map: Prior to issuance of any building permits for the project, the applicant shall have a completed parcel map as required for the proposed two-lot subdivision Tentative Parcel Map File No. PLN2004-146. 29. Street Improvements: Prior to recordation of the parcel map, the applicant shall execute a street improvement agreement, cause plans for public street improvements to be prepared by a registered civil engineer, pay various fees and deposits, post security and provide insurance necessary to obtain an encroachment permit for construction of the standard public street improvements, as required by the City Engineer. The plans shall include the following: a. Removal of all existing driveway approaches and necessary sidewalk, curb, and gutter to accommodate the new driveway approaches. b. Installation of City standard curb, gutter, sidewalk, and ADA compliant driveway approaches. c. Construction of conforms to existing public and private improvements, as necessary. 30. Occupancy: Prior to allowing occupancy for any and/or all buildings, the applicant shall have the required street improvements installed and accepted by the City. 31. Water Meter(s) and Sewer Cleanout(s): Existing and proposed water meter(s) and sewer cleanout(s) shall be relocated or installed on private property behind the public right-of-way 32. Utilities: All on-site utilities shall be installed underground per Section 21.18.140 of the Campbell Municipal Code for any new or remodeled buildings or additions. Applicant shall comply with all plan submittals, permitting, and fee requirements of the serving utility companIes. 33. Utility Coordination Plan: Prior to issuance of building permits for the site, the applicant shall submit a utility coordination plan and schedule for approval by the City Engineer for installation and/or abandonment of all utilities. The plan shall clearly show the location and size of all existing utilities and the associated main lines; indicate which utilities and services are to remain; which utilities and services are to be abandoned, and where new utilities and services will be installed. Joint trenches for new utilities shall be used whenever possible. 34. Pavement Restoration: Based on the utility coordination plan, the applicant shall prepare a pavement restoration plan for approval by the City Engineer prior to any utility installation or abandonment. Streets that have been reconstructed or overlaid within the previous five years will require boring and jacking for all new utility installations. San Tomas Aquino Road was overlaid in 1999 and reconstructed in FY 2000/01. The pavement restoration plan shall indicate how the street pavement shall be restored following the installation or abandonment of all utilities necessary for the project. 35. Grading and Drainage Plan: Prior to issuance of any grading or building permits for the site, the applicant shall conduct hydrology studies based on a ten-year storm frequency, prepare Planning Commission Reso.. .ton No. 3638 PLN2005-05 -1141 S. San Tomas Aquino Road - New Single-Family Residence (Parcel 2) Page 8 and engineered grading and drainage plan, and pay fees required to obtain necessary grading permits. The plans shall comply with the 1998 edition of the California Building Code including Chapters 10, 11, 18,33, and Appendix Chapter 33. 36. Stormwater Pollution Prevention Measures: Prior to issuance of any grading or building permits, the applicant shall comply with the National Pollution Discharge Elimination System (NPDES) permit requirements, Santa Clara Valley Water District requirements, and the Campbell Municipal Code regarding stormwater pollution prevention. The primary objectives are to improve the quality and reduce the quantity of stormwater runoff to the bay. Resources to achieve these objectives include Storm water Best Management Practices Handbook for New Development and Redevelopment ("CA BMP Handbook") by the California Stormwater Quality Association (CASQA), 2003; Start at the Source: A Design Guidance Manual for Stormwater Quality Protection ("Start at the Source") by the Bay Area Stormwater Management Agencies Association (BASMAA), 1999; and Using Site Design Techniques to Meet Development Standards for Stormwater Quality: A Companion Document to Start at the Source ("Using Site Design Techniques") by BASMAA, 2003. COUNTY FIRE DEPARTMENT 37. Formal Plan Review: Review of this development proposal is limited to accessibility of site access and water supply as they pertain to fire department operations, and shall mot be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall make application to, and receive from, the Building Division all applicable construction permits. 38. Required Fire Flow: The required fire flow for this project is 1,750 gpm at 20 psi residual pressure. The required fire flow is available from area water mains and fire hydrant(s), which are located at the required spacing. If a sprinkler system is installed the fire flow will be reduced to 1,000 gallons per minute. 39. Required Access to Water Supply (Hydrants): Portions of the structure(s) are greater than 150 feet of travel distance from the centerline of the roadway containing public fire hydrants. Provide an on-site fire hydrant OR provide an approved fire sprinkler system throughout all portions of the building. Revise general notes to reflect compliance with this requirement. 40. Fire Apparatus (Engine) Access Roads Required: Provide an access driveway with a paved all weather surface, a minimum unobstructed width of 12 feet, vertical clearance of 13 feet 6 inches, minimum circulating turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 15%. Installations shall conform to Fire Department Standard Details and Specifications sheet D-l. 41. Timing of Required Roadwav Installations: Required driveway installations shall be constructed and accepted by the Fire Department, prior to the start of construction. Bulk combustible materials shall not be delivered to the site until installations are complete. Note that building permit issuance may be withheld until installations are completed. Planning Commission Resolution No. 3638 PLN200S-0S -1141 S. San Tomas Aquino Road - New Single-Family Residence (Parcel 2) Page 9 42. Premises Identification: Approved numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their background. PASSED AND ADOPTED this 22nd day of March, 2005, by the following roll call vote: AYES: NOES: ABSENT: ABSTAIN : Commissioners: Commissioners: Commissioners: Commissioners: Doorley, Ebner, Francois, Rocha and Roseberry None Alderete and Gibbons None APPROVED. Geo MEMORANDUM To: Planning Commission Date: March 22, 2005 From: Stephanie Willsey, Planner I ~ Added Condition of Approval Subject: Consistent with department policy, staff proposes to add the following condition of approval to the three items on the agenda (file numbers PLN2005-04, PLN2005-05, and PLN2004-142): Contractor Contact Information Posting: The project site shall be posted with the name and contact number of the lead contractor in a location visible from the public street prior to the issuance of building permits. CITY OF CAMPBELL' PLANNING COMMISSION Staff Report. March 22, 2005 PLN2005-05 Fong, S. Public Hearing to consider the application of Ms. Sukkin Fong for a Site and Architectural Review Permit (PLN2005-05) to allow the construction of a new two-story single-family residence on property owned by Ms. Sukkin Fong located at 1141 S. San Tomas Aquino Road in an R-I-9 (Single- Family Residential) zoning district. STAFF RECOMMENDATION That the Planning Commission take the following action: 1. Adopt a Resolution incorporating the attached findings, approving a Site and Architectural Review Permit to allow the construction of a new two-story single-family residence, subject to the attached conditions of approval. ENVIRONMENTAL DETERMINATION Staff recommends that the Planning Commission find that this project is Categorically Exempt under Section 15303, Class 3, of the California Environmental Quality Act (CEQA) pertaining to the construction of a single-family residence in a residential zone. PROJECT DATA Catel!:Orv Proposed ReQuired! Allowed Gross Lot Area: 11,747 sq. ft. (0.27 acres) N/A Net Lot Area: 9,980 sq. ft. (0.23 acres) 9,900 sq. ft. Density: 3.7 units/gross acre Less than 4.5 units/gross acre Floor Area Ratio: 4,201 sq. ft. (0.42) 4,491 sq. ft. maximum (0.45) Building Coverage: 2,842 sq. ft. (28%) 3,493 sq. ft. maximum (35%) Building Area: 1 st Floor: 1,963 sq. ft. N/A 2nd Floor: 1,413 sq. ft. N/A Garage: 825sq. ft. 200 sq. ft. minimum Covered Porch: 54 sq. ft. N/A Total: 4,255 sq. ft. N/A Building Height: 26 ft. 2 in. 28 ft. maximum Parking: 3 covered, 3 uncovered 1 covered, 1 uncovered Staff Report - Planning Commission - Meeting of March 22,2005 PLN2005-05 -1141 S. San Tomas Aquino Road (Parcel 2) Page 2 of 4 DISCUSSION Applicant's Proposal: The applicant is requesting approval of a Site and Architectural Review Permit to allow the construction of a new two-story single-family residence on property located at 1141 S. San Tomas Aquino Road (Parcel 2). Background: The subject property is currently developed with a single-story residence and three detached accessory structures. The Community Development Director approved a Tentative Parcel Map on January 13, 2005 to subdivide the property into two residential parcels. The approved lot configuration consists of one standard lot (Parcell) facing San Tomas Aquino Road and one rear flag-lot (Parcel 2). The existing residence and accessory structures will be demolished prior to recordation of the final parcel map. The applicant is requesting approval of a Site and Architectural Review Permit application for the construction of a new house on Parcel 2 at this time. Property Location: The subject property is a flag lot located on the west side of South San Tomas Aquino Road, adjacent to Turner Way, between Munro Avenue and West Hacienda Avenue. The property is surrounded on all sides by single-family residences. ANALYSIS General Plan Designation: The General Plan land use designation for the project site is Low Density Residential (less than 4.5 units per gross acre). The proposed project has a density range of 3.7 units per gross acre, which is within the density range allowed for the site. The proposed project complies with the following General Plan Land Use Element Strategies: Strategy LUT-5.2a: Neighborhood Compatibility: Promote new residential development and substantial additions that are designed to maintain and support the existing character and development pattern of the surrounding neighborhood, especially in historic neighborhoods and neighborhoods with consistent design characteristics. Strategy LUT - 7 .2n: Consistency With Plans: Ensure that new development and substantial remodeling projects are consistent with Specific Plans, Area Plans, City Standard Details and adopted Streetscape Standards to create a cohesive design. Strategy LUT -17.1 b: Landscaping: Ensure that new developments provide new tree plantings, shrubs, greenery and other landscaping materials, and preserve existing trees and shrubs. San Tomas Area Neighborhood Plan: The project site is located in the San Tomas Neighborhood and is subject to the San Tomas Area Neighborhood Plan (STANP). Staff finds that the proposed project is consistent with the development standards and design guidelines of the STANP. Zoning Designation: The zoning designation for the project site is R-1-9 (Single-Family Residential, 9,000 square foot minimum lot size). Flag lots require a minimum lot area of 9,900 square feet exclusive of a l5-foot wide access way. The proposed project is consistent with this Staff Report - Planning Commission - Meeting of March 22,2005 PLN2005-05 -1141 S. San Tomas Aquino Road (Parcel 2) Page 3 of4 zoning designation and meets the minimum lot size, lot width, setbacks, height, building coverage, floor area ratio, and parking requirements of the R-1-9 Zoning District. Site Layout and Architecture: The proposed site plan shows the construction of a new two-story residence with an attached three-car garage. The front of the house faces Turner Way to provide consistency with the other homes along Turner Way and takes vehicular access from a private driveway from South San Tomas Aquino Road. The proposed residence incorporates representative architectural features of other homes in the San Tomas Neighborhood including simple rectangular shaped building forms, hipped and gabled roof forms, a and a smooth stucco exterior. Additional architectural features include a defined entry porch and decorative garage doors. The proposed residence incorporates a consistent window style on all elevations. The proposed colors for the house consist of a pink/peach body color and white trim. The proposed roof material is a grey colored composition shingle. Landscaping/Trees: Pursuant to the STANP, the applicant is required to provide one tree per each 2,000 square feet of net lot area; for a total of five trees. The conditions of approval require that the applicant submit a landscape plan indicating the required trees and landscaping in the front yard area. The applicant is not proposing to remove any protected trees as part of this development. One 24- inch in diameter tree is located on the site and is a protected tree under the City's Tree Protection Regulations. The conditions of approval require that the applicant submit a tree protection plan for this protected tree to be retained on site. Site and Architectural Review Committee: The Site and Architectural Review Committee reviewed this application at its meeting of March 8, 2005. The Committee was supportive of the project, subject to the following recommended changes: . The exterior body color be modified from the proposed pink/peach color to an earth tone color; and . A decorative pavement material should be used for the driveway. Staff has added these two recommendations as conditions of approval for the project. Attachments: 1. Findings for Approval of File No. PLN2005-05 2. Conditions of Approval for File No. PLN2005-05 3. Project Exhibits 4. Location Map Staff Report - Planning Cummission - Meeting of March 22,2005 PLN2005-05 -1141 S. San Tomas Aquino Road (Parcel 2) Page 4 of 4 Prepared by: Approved by: ~e{Jh~ Wi \~ Stephanie Willsey, Planner 1 ~~ ",. Sharon Fierro, Community Development Director Attachment # 1 FINDINGS FOR APPROVAL OF FILE NO. PLN2005-05 SITE ADDRESS: APPLICANT: DATE: 1141 S. San Tomas Aquino Road (Parcel 2) Ms. Sukkin Fong March 22, 2005 Findings for approval of a Site and Architectural Review Permit to allow the construction of a new two story single-family residence on property located at 1141 S. San Tomas Aquino Road (Parcel 2). The Planning Commission finds as follows with regard to File No. PLN2005-05: 1. The density of the proposed project will result in a density of3.7 units per gross acre, which is consistent with the General Plan land use designation of Low Density Residential (less than 4.5 units per gross acre). 2. The proposed project is consistent with the R-I-9 (Single-Family Residential, 9,000 square foot minimum lot size) zoning district and meets the minimum setbacks, height restriction, building coverage, floor area ratio, and parking requirements of the R-1-9 Zoning District. 3. The project is consistent with the development standards and design guidelines of the San Tomas Area Neighborhood Plan. 4. The proposed home on Parcel 2 consists of a new 4,255 square foot, two-story single-family residence with a building coverage of 28% and Floor Area of 0.42. 5. The height of the proposed home is 26 feet, 2 inches where the maximum height limit is 28 feet. 6. The front of the house faces Turner Way to provide consistency with the other homes along Turner Way and takes vehicular access from a private driveway from South San Tomas Aquino Road. 7. The proposed project is surrounded by single-family residential uses on all sides. 8. The project provides three covered and three uncovered parking spaces where a minimum of one covered and one uncovered parking space is required. 9. The applicant is not proposing to remove any protected trees. There is one mature tree on site that is a protected tree under the City's Tree Protection Ordinance and is being incorporated into the site design and layout. 10. The project qualifies as a Categorically Exempt project per Section 15303, Class 3, of the California Environmental Quality Act (CEQA). Attachment # 1 Page 2 of2 Based upon the foregoing findings of fact, the Planning Commission further finds and concludes that: 1. The proposed project is consistent with the City of Campbell General Plan and Zoning Ordinance. 2. The proposed project, as conditioned, will aid In the harmonious development of the immediate area. 3. The proposed project is well designed and is architecturally compatible with the surrounding neighborhood. 4. No substantial evidence has been presented from which a reasonable argument could be made that shows that the project, as currently presented and subject to the required conditions of approval, will have a significant adverse impact on the environment. 5. The proposed development will not be detrimental to the health, safety or welfare of the neighborhood or the City as a whole. 6. The proposed project will contribute to the housing stock in the City of Campbell and serve the housing needs of the community. 7. There is a reasonable relationship between the use of the fees imposed upon the project and the type of development project. 8. There is a reasonable relationship and a rough proportionality between the conditions of approval and the impacts ofthe project. Attachment #2 CONDITIONS OF APPROVAL FOR FILE NO. PLN2005-05 SITE ADDRESS: APPLICANT: DATE: 1141 S. San Tomas Aquino Road (Parcel 2) Ms. Sukkin Fong March 22, 2005 The applicant is hereby notified, as part of this application, that (s)he is required to meet the following conditions in accordance with the ordinances of the City of Campbell and the State of California. The lead department with which the applicant will work is identified on each condition where necessary. Where approval by the Director of Community Development, City Engineer, Public Works Director, City Attorney, or Fire Department is required, that review shall be for compliance with all applicable conditions of approval, adopted policies and guidelines, ordinances, laws and regulations, and accepted engineering practices, for the items under review. Additionally, the applicant is hereby notified that (s)he is required to comply with all applicable Codes or Ordinances of the City of Campbell and the State of California that pertains to this development and are not herein specified: COMMUNITY DEVELOPMENT DEPARTMENT Planning Division: 1. Approved Proiect: Approval is granted for a Site and Architectural Review Permit (PLN2005-05) to allow the construction of a new two story single-family residence located at 1141 S. San Tomas Aquino Road (Parcel 2). The building design and site design shall substantially conform to the project exhibits listed below, except as may be modified by the conditions of approval herein: a. Project plans stamped as received by the Planning Division on February 15, 2005 including a site plan, floor plans, elevations, and a landscape plan. b. Color/material board stamped as received by the Planning Division on February 15,2005. c. Colored elevations stamped as received by the Planning Division on February 15,2005. 2. Approval Expiration: The Site and Architectural Review Permit approval shall be valid for a period of one year from the date of final approval. Within this one-year period, a building permit must be obtained and construction completed one year thereafter or the Site and Architectural Review Permit shall be void. 3. Fences: Any existing or new fencing shall comply with Section 21.18.060 of the Campbell Municipal Code. Fencing along the property lines shall be replaced with a six-foot high "good neighbor" wood fence by the applicant, unless it is determined to be in good condition by the Community Development Director. 4. Property Maintenance: The property is to be maintained free of any combustible trash, debris and weeds until the time that actual construction commences. All existing structures shall be secured by having windows boarded up and doors sealed shut, or demolished or removed from the property. Attachment #2 Page 2 of6 5. Parking and Drivewavs: a. All parking and driveway areas shall be developed in compliance with the approved plans and Chapter 21.28 (Parking and Loading) of the Campbell Municipal Code. b. The applicant shall provide a decorative paving treatment within the driveway for the home. The design and materials used for the decorative pavement shall be indicated on the building permit plans and shall be reviewed and approved by the Community Development Director prior to the issuance of building permits. 6. Final Parcel Map: The Site and Architectural Review Permit approval is contingent upon recordation of the Final Parcel Map to divide the subject property. The Final Parcel Map shall be recorded prior to the issuance of building permits. 7. Exterior Building Colors: The applicant shall submit a revised color/material board to the Planning Division, prior to the issuance of building permits, which depicts a modified exterior building color from the proposed pink/peach color to an earth tone color. The proposed colors shall be subject to review and approval by the Community Development Director. 8. Park Impact Fee: A park impact fee, based on a density range of less than six units per gross acre, is due upon development of the site. Credit shall be given for any existing single- family residence to be demolished. Prior to recordation of the Parcel Map, 75% of this fee is due. The remaining 25% is due prior to issuance of a certificate of building occupancy. 9. Landscape Plan: The applicant shall submit a final landscape and irrigation plan to the Planning Division, prior to the issuance of building permits, for review and approval by the Community Development Director. The required trees and landscaping shall be installed prior to the issuance of a Certificate of Building Occupancy. The landscape and irrigation plan shall substantially conform with the approved conceptual landscape plan and the City's Water Efficient Landscaping Standards (WELS) and shall include the following: a. A minimum of five trees on Parcel 2. b. Landscaping in the front yard area of the home. 10. Tree Protection Plan: The applicant shall submit a tree protection plan for the protected trees to be retained on site and shall contain specific information about the preservation of the trees during any grading or building on site. The tree protection plan shall be submitted to the Planning Division for review and approval by the Community Development Director prior to the issuance of building permits. Such tree protection measures shall be installed prior to any demolition, grading, or building on the project site. No construction or trenching shall take place within the drip line of trees and a fence constructed of temporary cyclone fencing or wire mesh securely attached to poles driven into the ground shall be installed around the drip line of the tree. All trimming or branch removal from protected trees shall be completed by a certified arborist. 11. Utilities: All new on-site utilities shall be installed underground per section 21.18.140 of the Campbell Municipal Code. Attachment #2 Page 3 of6 12. On-Site Lighting: On-site lighting shall be shielded away from adjacent properties and directed on site. The design and type of lighting fixtures and lighting intensity of any proposed exterior lighting for the project shall be reviewed and approved by the Community Development Director prior to installation of the lighting for compliance with all applicable Conditions of Approval, ordinances, laws and regulations. Lighting fixtures shall be of a decorative design to be compatible with the residential development and shall incorporate energy saving features. 13. Construction Hours: Construction activities shall be limited to the hours of 8:00 a.m. to 5:00 p.m. weekdays and 9:00 a.m. to 4:00 p.m. Saturdays. Construction is prohibited on Sundays and Holidays unless an exception is granted by the Building Official. Building Division: 14. Permits Required: A building permit application shall be required for the proposed new dwelling structure. The building permit shall include Electrical/Plumbing/Mechanical fees when such work is part of the permit. 15. Construction Plans: The conditions of approval shall be stated in full on the cover sheet of construction plans submitted for building permit. 16. Size of Plans: The size of construction plans submitted for building permits shall be 24 inches by 36 inches. 17. Plan Preparation: This project requires plans prepared under the direction and oversight of a California licensed Engineer or Architect. Plans submitted for building permits shall be "wet stamped" and signed by the qualifying professional person. 18. Soils Report: The applicant shall submit two copies of a current soils report containing foundation and retaining wall design recommendations, prepared to the satisfaction of the Building Official, with the building permit application. This report shall be prepared by a licensed engineer specializing in soils mechanics. 19. Site Plan: Application for building permit shall include a competent site plan that identifies property and proposed structures with dimensions and elevations as appropriate. Site plan shall also include site drainage details. 20. Foundation Inspection: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project building inspector upon foundation inspection. This certificate shall certify compliance with the recommendations as specified in the soils report and the building pad elevation and on-site retaining wall locations and elevations are prepared according to approved. Plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered civil engineer for the following items: a. pad elevation b. finish floor elevation (first floor) c. foundation comer locations Attachment #2 Page 4 of6 21. Title 24 Energv ComDliance: California Title 24 Energy Compliance forms CF-IR and MF- lR shall be blue-lined on the construction plans. 8% X 11 calculations shall be submitted as well. 22. Special Inspections: When a special inspection is required by U.B.c. Section 1701, the architect or engineer of record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the building permits, in accordance with D.B.C Section 106.3.5. Please obtain City of Campbell, Special Inspection forms from the Building Inspection Division Counter. 23. Non-Point Source Pollution Control: The City of Campbell standard Santa Clara Valley Non-point Source Pollution Control Program specification sheet shall be part of plan submittal. The specification sheet (size 24 inches by 36 inches) is available at the Building Division service counter. 24. P.G.&E.: The applicant is advised to contact P.G.&E. as early as possible in the approval process. Service installations, changes and/or relocations may require substantial scheduling time and can cause significant delays in the approval process. The applicant should also consult with P.G.&E. concerning utility easements, distribution pole locations and required conductor clearances. 25. Construction Fencing: This project shall be properly enclosed with construction fencing to prevent unauthorized access to the site during construction. The construction site shall be secured to prevent vandalism and/or theft during hours when no work is being done. All protected trees shall be fenced to prevent damage to root systems. 26. Project Approvals: The project requires the following agency approval prior to issuance of the building permit: a. West Valley Sanitation District (378-2407) b. Santa Clara County Fire Department (378-4010) c. Bay Area Air Quality Management District (Demolitions Only) c. School District: i. Campbell Union School District (378-3405) ii. Campbell Union High School District (371-0960) iii. Moreland School District (379-1370) iv. Cambrian School District (377-2103) Note: To determine your district, contact the offices identified above. Obtain the School District payment form from the City Building Division, after the Division has approved the building permit application. PUBLIC WORKS DEPARTMENT 27. Parcel Map: Prior to issuance of any building permits for the project, the applicant shall have a completed parcel map as required for the proposed two-lot subdivision Tentative Parcel Map File No. PLN2004-146. Attachment #2 Page 5 of6 28. Street Improvements: Prior to recordation of the parcel map, the applicant shall execute a street improvement agreement, cause plans for public street improvements to be prepared by a registered civil engineer, pay various fees and deposits, post security and provide insurance necessary to obtain an encroachment permit for construction of the standard public street improvements, as required by the City Engineer. The plans shall include the following: a. Removal of all existing driveway approaches and necessary sidewalk, curb, and gutter to accommodate the new driveway approaches. b. Installation of City standard curb, gutter, sidewalk, and ADA compliant driveway approaches. c. Construction of conforms to existing public and private improvements, as necessary. 29. Occupancy: Prior to allowing occupancy for any and/or all buildings, the applicant shall have the required street improvements installed and accepted by the City. 30. Water Meter(s) and Sewer Cleanout(s): Existing and proposed water meter(s) and sewer cleanout(s) shall be relocated or installed on private property behind the public right-of-way 31. Utilities: All on-site utilities shall be installed underground per Section 21.18.140 of the Campbell Municipal Code for any new or remodeled buildings or additions. Applicant shall comply with all plan submittals, permitting, and fee requirements of the serving utility companIes. 32. Utilitv Coordination Plan: Prior to issuance of building permits for the site, the applicant shall submit a utility coordination plan and schedule for approval by the City Engineer for installation and/or abandonment of all utilities. The plan shall clearly show the location and size of all existing utilities and the associated main lines; indicate which utilities and services are to remain; which utilities and services are to be abandoned, and where new utilities and services will be installed. Joint trenches for new utilities shall be used whenever possible. 33. Pavement Restoration: Based on the utility coordination plan, the applicant shall prepare a pavement restoration plan for approval by the City Engineer prior to any utility installation or abandonment. Streets that have been reconstructed or overlaid within the previous five years will require boring and jacking for all new utility installations. San Tomas Aquino Road was overlaid in 1999 and reconstructed in FY 2000/01. The pavement restoration plan shall indicate how the street pavement shall be restored following the installation or abandonment of all utilities necessary for the project. 34. Grading and Drainage Plan: Prior to issuance of any grading or building permits for the site, the applicant shall conduct hydrology studies based on a ten-year storm frequency, prepare and engineered grading and drainage plan, and pay fees required to obtain necessary grading permits. The plans shall comply with the 1998 edition of the California Building Code including Chapters 10, 11, 18,33, and Appendix Chapter 33. 35. Stormwater Pollution Prevention Measures: Prior to issuance of any grading or building permits, the applicant shall comply with the National Pollution Discharge Elimination System (NPDES) permit requirements, Santa Clara Valley Water District requirements, and the Campbell Municipal Code regarding stormwater pollution prevention. The primary Attachment #2 Page 6 of6 objectives are to improve the quality and reduce the quantity of stormwater runoff to the bay. Resources to achieve these objectives include Storm water Best Management Practices Handbook for New Development and Redevelopment ("CA BMP Handbook") by the California Stormwater Quality Association (CASQA), 2003; Start at the Source: A Design Guidance Manual for Storm water Quality Protection ("Start at the Source") by the Bay Area Stormwater Management Agencies Association (BASMAA), 1999; and Using Site Design Techniques to Meet Development Standards for Storm water Quality: A Companion Document to Start at the Source ("Using Site Design Techniques") by BASMAA, 2003. COUNTY FIRE DEPARTMENT 36. Formal Plan Review: Review of this development proposal is limited to accessibility of site access and water supply as they pertain to fire department operations, and shall mot be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall make application to, and receive from, the Building Division all applicable construction permits. 37. Required Fire Flow: The required fire flow for this project is 1,750 gpm at 20 psi residual pressure. The required fire flow is available from area water mains and fire hydrant(s), which are located at the required spacing. If a sprinkler system is installed the fire flow will be reduced to 1,000 gallons per minute. 38. Required Access to Water Supply (Hydrants): Portions of the structure(s) are greater than 150 feet of travel distance from the centerline of the roadway containing public fire hydrants. Provide an on-site fire hydrant OR provide an approved fire sprinkler system throughout all portions of the building. Revise general notes to reflect compliance with this requirement. 39. Fire Apparatus (Engine) Access Roads Required: Provide an access driveway with a paved all weather surface, a minimum unobstructed width of 12 feet, vertical clearance of 13 feet 6 inches, minimum circulating turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 15%. Installations shall conform to Fire Department Standard Details and Specifications sheet D-l. 40. Timing of Required Roadway Installations: Required driveway installations shall be constructed and accepted by the Fire Department, prior to the start of construction. Bulk combustible materials shall not be delivered to the site until installations are complete. Note that building permit issuance may be withheld until installations are completed. 41. Premises Identification: Approved numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their background. March 11, 2005 NOTICE OF PUBLIC HEARING Notice is hereby given that the Planning Commission of the City of Campbell has set the time of 7:30 p.m., or shortly thereafter, on Tuesday, March 22, 2005, in the City Hall Council Chambers, 70 North First Street, Campbell, California, for a Public Hearing to consider the application of Ms. Sukkin Fong for a Site and Architectural Review Permit (PLN2005-05) to allow the construction of a new two-story single-family residence on property owned by Ms. Sukkin Fong located at 1141 S. San Tomas Aquino Road in an R-I-9 (Single Family Residential) Zoning District. Staff is recommending that this project be deemed Categorically Exempt under CEQA. Interested persons may appear and be heard at this hearing. Please be advised that if you challenge the nature of the above project in court, you may be limited to raising only those issues you or someone else raised at the Public Hearing described in this Notice, or in written correspondence delivered to the City of Campbell Planning Commission at, or prior to, the Public Hearing. Questions may be addressed to the Community Development Department at (408) 866-2140. Decisions of the Planning Commission may be appealed to the City Council. Appeals must be submitted to the City Clerk in writing within 10 calendar days of an action by the Commission. In compliance with the Americans with Disabilities Act, listening assistive devices are available for all meetings held in the Council Chambers. If you require accommodation, please contact the Community Development Department at (408) 866-2140, at least one week in advance of the meeting. PLANNING COMMISSION CITY OF CAMPBELL SHARON FIERRO SECRETARY PLEASE NOTE: When calling about this Notice, please refer to File No. PLN2005-05 Address: 1141 S. San Tomas Aquino Road 70 North First Street. Campbell, California 95008-1436 . TEL 408.866.2140 . FAX 408.871.5140 . TDD 408.866.2790 Community Development Department March 1, 2005 Re: PLN2005-05 -1141 S. San Tomas Aquino Road - Site & Architectural Review Permit Dear Applicant: Please be advised that the above-referenced application has been scheduled for the following meeting(s): Site and Architectural Review Committee Meeting Date: Tuesday, March 8, 2005 Time: 6:40 p.m. Location: Doetsch Conference Room, City Hall, 70 N. First Street, Campbell Planning Commission Meeting Date: Tuesday, March 22, 2005 Time: 7:30 p.m. Location: City Hall Council Chambers, 70 N. First Street, Campbell Should you have any questions or comments, please do not hesitate to contact me at (408) 866- 2140. Sincerely, ~~ UJ{((~ Stephanie Willsey () Planner I . cc: Sukkin Fong (Applicant & Property Owner) 13132 De1son Court Los Altos, CA 94022 70 North First Street. Campbell, California 95008-1436 . TEL 408.866.1140 . FAX 408.871.5140 . TDO 408.866.1790 To: Site and Architectural Review Committee Stephanie Willsey, Planner I ~ Date: March 8, 2005 From: Subject: 1141 S. San Tomas Aquino Road (parcel 2) - Site and Architectural Review Permit PROPOSAL The applicant is requesting approval of a Site and Architectural Review Permit to allow the construction of a new two-story single-family residence on property located at 1141 S. San Tomas Aquino Road. The residence consists of 1,963 square feet of living space on the first floor, 1,413 square feet of living space on the second floor, a 825 square foot attached garage, and a 54 square foot covered porch. The subject property is a flag lot located on the west side of South San Tomas Aquino Road, adjacent to Turner Way, between Munro Avenue and Hacienda Avenue. The property is surrounded by single- family residences on the north, south, east, and west. The site is currently developed with a single- story, single-family residence. The Community Development Director approved a Tentative Parcel Map on January 13, 2005 to subdivide the property into two residential parcels. The applicant is requesting approval of a Site and Architectural Review Permit application for the construction of a new house on Parcel 2 (rear parcel) at this time. The project site is located in the San Tomas Neighborhood and is subject to the San Tomas Area Neighborhood Plan (STANP). The zoning designation for the project site is R-1-9 (Single-Family Residential, 9,000 square foot minimum lot size). The proposed project is consistent with the zoning designation and meets the minimum setbacks, height restriction, building coverage, floor area ratio, and parking requirements of the R-1-9 Zoning District. ST AFF ANALYSIS Staff is recommending the second floor bay window on the rear elevation be eliminated to provide consistency with the design guidelines outlined in the STANP. Staff is also recommending that the exterior body color be modified to an earthtone or beige color rather than the proposed peach color. Staff does not have any other outstanding issues and is generally supportive ofthe proposed project. Attachment: Reduced Plans Location Map February 1,2005 Ms. Sukkin Fong 13132 Delson Court Los Altos, CA 94022 Re: Site and Architectural Review Permit Application File No.: PLN2005-00005 1141 S. San Tomas Aquino Road (Parcel 2) Dear Ms. Fong: Thank you for your Site and Architectural Review application for the construction of a new two- story single-family residential on Parcel 2 (rear lot) located at 1441 S. San Tomas Aquino Road. The subject property is currently zoned R-1-9 and is located in the San Tomas Neighborhood and subject to the development standards and design guidelines of the San Tomas Area neighborhood Plan (ST ANP). The granting of a Site and Architectural Review Permit will require approval by the Planning Commission and will be decided upon at a public hearing. Your application has been deemed incomplete. The following additional information and details are needed in order to deem your application complete and schedule it for meetings with the Site and Architectural Review Committee (a sub-committee of the Planning Commission) and the Planning Commission: 1. Colored Elevation: Please provide a colored elevation for the proposed home. Please submit 10 colored copies of the colored elevation. 2. Sample Board: Please provide a sample board to include samples of the exterior building materials, roof material, and paint colors. The maximum size shall not exceed 11" x 17". 3. Site Plan: The following information needs to be provided on the site plan: a. Show the street right-of-way and dimension to centerline of street. b. Provide the location for all proposed utility connections. All new utility services will be required to be placed underground per section 21.18.140 of the Campbell Municipal Code. c. Please include the proposed driveway material on the Site Plan. d. The minimum setback to the garage is 25'-0". The proposed one-car garage encroaches into the required 25' -0" setback. Please revise the plans to provide a minimum 25' -0" garage setback. 70 North First Street. Campbell, California 95008-1436 . TEL 408.866.2140 . FAX 408.871.5140 . TlJIl 408.866.2790 PLN2005-00005 -1441 S. S.. lomas Aquino Road PaIle 2 of 2 e. Provide the location and uses of all structures on the adjacent properties. Describe the height, setbacks, and type of these structures. f. Provide a front yard paving calculation in the project data area. A minimum of 50 percent of the required front yard setback shall remain unpaved. 4. Architecture and Design: The following requests are intended to ensure compliance with the San Tomas Area Neighborhood Plan (ST ANP). a. The ST ANP requires that new homes minimize the use of two story vertical design elements such as turrets. This may be accomplished by eliminating the bay window on the second floor of the rear elevation. b. The ST ANP requires that new homes minimize the use of vertical design features that emphasize the height of the structure. Staff recommends reducing the depth and width of Bedroom #4 on the second floor of the front elevation to eliminate the vertical design feature. This will provide a "stepped-in" appearance above the proposed study/bedroom on the first floor. c. New homes should avoid design features no commonly found in the San Tomas Neighborhood, such as stucco with heavy moldings. Staff recommends reducing the size of the fascia boards on all elevations. d. Please provide a consistent window style and design on all elevations. Please find enclosed recommended conditions of approval from the Building Division, County Fire Department, and Public Works Department for your project. Please resubmit 10 reduced size set of plans at 11" x 17" and 2 full size set of plans at 24" x 36". Thank you for the opportunity to review these plans. If you should have any questions regarding these comments or the requested information, please feel free to contact me at (408) 866-2142 or by email atmelindad@cityofcampbell.com. Sincerely, Melinda M. Denis Planner I End: Building Division Conditions of Approval, 1/31/05 County Fire Department Conditions of Approval, 1/18/05 Public Works Department Conditions of Approval, 1/14/05 cc: GeoffBradley, Senior Planner CITY OF CAMPBELL BUll..DING INSPECTION DIVISION - COMMENTS TO THE DEVELOPMENT REVIEW COMMITfEE DRC: January 31, 2005 ADDRESS: 1141 N San Tomas Aquino Rd. Project Application: PLN2005-00005 RECOMMENDATION: Note: No building code issue has been reviewed at Development Review Committee; it will be reviewed in the Building Pennit process. Please be aware that building codes are changing constantly; plans submitted for building permit shall comply with the code in effect at that time. Submit pennit application together with required documents to the Building Inspection Division to obtain a building permit. No construction can be commenced without an appropriate building permit. It is recommended that this item be forwarded to the Phmning Commission for review, with the following conditions. TO THE SATISFACTION OF THE BUILDING DMSION MANAGER/BUILDING OFFICIAL: 1. PERMITS REQUIRED: A building permit application shall be required for the proposed new dwelling structure. The building permit shall include Electrical/Plumbing/Mechanical fees when such work is part of the permit. 2. CONSTRUCTION PLANS: The conditions of Approval shall be stated in full on the cover sheet of construction plans submitted for building permit. 3. SIZE OF PLANS: The minimum size of construction plans submitted for building permits shall be 24 in. X 36 in. 4. PLAN PREPARATION: This project requires plans prepared under the direction and oversight of a California licensed Engineer or Architect. Plans submitted for building permits shall be "wet stamped" and signed by the qualifying professional person. 5. SOILS REPORT: Two copies of a current soils report, prepared to the satisfaction of the Building Official, containing foundation and retaining wall design recommendations shall be submitted with the building permit application. This report shall be prepared by a licensed engineer specializing in soils mechanics. 6. SITE PLAN: Application for building permit shall include a competent site plan prepared by a licensed engineer that identifies property and proposed structures with dimensions and elevations as appropriate. Site plan shall also include site drainage details. 7. FOUNDATION INSPECTIONS: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project building inspector upon foundation inspection. This J:\BuildiIur DRC Commeuts\1141nstar.doc certificate shall certify compliance with the recommendations as specified in the soils report and the building pad elevation and on-site retaining wall locations and elevations are prepared according to approved plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered civil engineer for the following items: a. pad elevation b. finish floor elevation (first floor) c. foundation comer locations 8. TITLE 24 ENERGY COMPLIANCE: California Title 24 Energy Compliance forms CF-IR and MF-IR shall be blue-lined on the construction plans. 8% X 11 calculations shall be submitted as well. 9. SPECIAL INSPECTIONS: When a special inspection is required by V.B.C. Section 1701, the architect or engineer of record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the building permits, in accordance with U.B.C Section 106.3.5. Please obtain City of Campbell, Special Inspection forms from the Building Inspection Division Counter. 10. The City of Campbell, standard Santa Clara Valley Non-point Source Pollution Control Program specification sheet shall be part of plan submittal. The specification sheet (size 24" X 36") is available at the Building Division service counter. 11. APPROVALS REQUIRED: The project requires the following agency approval prior to issuance of the building permit: a. West Valley Sanitation District (378-2407) b. Santa Clara County Fire Department (378-4010) c. School District: i) Campbell Union School District (378-3405) ii) Campbell Union High School District (371-0960) iii) Moreland School District (379-1370) iv) Cambrian School District (377-2103) Note: To Determine your district, contact the offices identified above. Obtain the School District payment form from the City Building Division, after the Division has approved the building permit application. d. Bay Area Air Quality Management District (Demolitions Only) 12. P.G.& E.: Applicant is advised to contact Pacific Gas and Electric Company as early as possible in the approval process. Service installations, changes and/or relocations may require substantial scheduling time and can cause significant delays in the approval process. Applicant should also consult with P.G. and E. concerning utility easements, distribution pole locations and required conductor clearances. J:\Buildine: ORe Comment8\1141Jllltar.doc 13. CONSTRUCTION FENCING: This project shall be properly enclosed with construction fencing to prevent unauthorized access to the site during construction. The construction site shall be secured to prevent vandalism and/or theft during hours when no work is being done. All protected trees shall be fenced to prevent damage to root systems. J:\Buil~ DRe Comments\11411lStar.doc FIR~ DEPARTMENT SANTA CLARA COUNTY PL..... REVIEW NUMBER 05 0093 BLDG PERMIT NUMBER 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 · (408) 378-9342 (fax) · www.sccfd.org CONTROL NUMBER PLN 2005-05 FILE NUMBER DEVELOPMENT REVIEW COMMENTS CODE/SEC. I SHEET FI REQUIREMENT Review of site plan for a proposed new 4,218 square foot single family residence with an attached garage. UK Appendix III-A UFC 903.2 UK 902.2.2 Review of this Developmental proposal is limited to acceptability of site access and water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall make application to, and receive from, the Building Department all applicable construction permits. 1. Required Fire Flow: The fire flow for this project is 1,750 gpm at 20 psi residual pressure. The required fire flow is available from area water mains and fire hydrant(s) which are spaced at the required spacing. If a sprinkler system is installed the fire flow will be reduced to 1000 gallons per minute. 2. Required Access to Water Supply (Hydrants): Portions of the structure(s) are greater than 150 feet of travel distance from the centerline of the roadway containing public fire hydrants. Provide an on-site fire hydrant OR, provide an approved fire sprinkler system throughout all portions of the building. Revise general notes to reflect compliance with this requirement. 3. Fire Apparatus (Engine)Access Driveway Required: Provide an access driveway with a paved all weather surface, a minimum unobstructed width of 12 feet, vertical clearance of 13 feet 6 inches, minimum circulating turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 15%. Installations shall conform to Fire Department Standard Details and Specifications sheet D-l. CBL City PLANS SPECS NEW RMDL AS OCCUPANCY CONST. TYPE JLK ASSOCIATES SECJFLOOR NAME OF PROJECT AppllcantName DATE PAGE 00000 1/18/2005 ~ OF ~ BY AREA LOAD DESCRIPTION Residential Development I LOCATION SFR- FaNG 1141 San Tomas Aquino Rd Organized as the Santa Clara County Central Fire Protection District Serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos. Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and Saratoga Rucker, Ryan CODE/SEC. UK Appendix III-A UK 901.4.4 PL..."REVIEWNUMBER 05 0093 FIR.... DEPARTMENT SANTA CLARA COUNTY BLDG PERMIT NUMBER 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 · (408) 378-9342 (fax) · www.sccfd.org CONTROL NUMBER PLN 2005-05 FILE NUMBER DEVELOPMENT REVIEW COMMENTS SHEET PI REQUIREMENT 4. Timing of Required Driveway Installations: Required driveway installations shall be constructed and accepted by the Fire Department, prior to the start of construction. Bulk combustible materials shall not be delivered to the site until installations are complete. Note that building permit issuance may be withheld until installations are completed. 5. Premises Identification: Approved numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their background. To prevent plan review and inspection delays, the above noted Developmental Review Conditions shall be restated as "notes" on all pending and future plan submittals and any referenced diagrams to be reproduced onto the future plan submittal. eBL City PLANS SPECS NEW RMDL AS OCCUPANCY CONST. TYPE AppllcantName JLK ASSOCIATES SECJFLOOR NAME OF PROJECT DATE PAGE 00000 1/18/2005 ~OF~ AREA LOAD DESCRIPTION BY Residential Development LOCATION Rucker, Ryan SFR- FONG 1141 San Tomas Aquino Rd Organized as the Santa Clara County Central Fire Protection District Serving Santa Clara County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos, Monte Sereno, Morgan Hill, and Saratoga MEMORANDUM CITY OF CAMPBELL TO: 117~linda Denis, Project Planner FROM: ~I Oxonian, Senior Civil Engineer , DATE: 1/14/05 RECEIVED SUBJECT: DRC -APPLICA TION k Lx......:. JAN 2 1 Z005 CITY OF CAMPBJ:ll PLANNING DEPT. Site Address: For File No: Project Description: 1141 S San Tomas Aquino Road PLN 2005-05 Site and Architectural Review for the construction of a new two-story single-family residence located on the rear lot of a proposed two lot subdivision (Tentative Parcel Map File No. PLN 2004-146). Sukkin Fong Applicant: PUBLIC WORKS DEPARTMENT CONDITIONS OF APPROVAL 1. Parcel Map: Prior to issuance of any building permits for the project, the applicant shall have a completed parcel map as required for the proposed two-lot subdivision Tentative Parcel Map File No. PLN 2004-146. 2. Street Improvements: Prior to recordation of the parcel map, the applicant shall execute a street improvement agreement, cause plans for public street improvements to be prepared by a registered civil engineer, pay various fees and deposits, post security and provide insurance necessary to obtain an encroachment permit for construction of the standard public street improvements, as required by the City Engineer. The plans shall include the following: a. Removal of all existing driveway approaches and necessary sidewalk, curb and gutter to accommodate the new driveway approaches. b. Installation of City standard curb, gutter, sidewalk and ADA compliant driveway approaches. c. Construction of conforms to existing public and private improvements, as necessary. 3. Occupancy: Prior to allowing occupancy for any and/or all buildings, the applicant shall have the required street improvements installed and accepted by the City. 4. Water Meter(s) and Sewer Cleanout(s): Existing and proposed water meter(s) and sewer cleanout(s) shall be relocated or installed on private property behind the public right-of-way line. J:\LandDev\Conditions\Plng\STAR S 1141 PLN 200S.DOC Page 1 of 2 1141 .:>. San Tomas Aquino Road 5. Utilities: All on-site utilities shall be installed underground per Section 21.18.140 of the Campbell Municipal Code for any new or remodeled buildings or additions. Applicant shall comply with all plan submittals, permitting, and fee requirements of the serving utility compames. 6. Utility Coordination Plan: Prior to issuance of building permits for the site, the applicant shall submit a utility coordination plan and schedule for approval by the City Engineer for installation and/or abandonment of all utilities. The plan shall clearly show the location and size of all existing utilities and the associated main lines; indicate which utilities and services are to remain; which utilities and services are to be abandoned, and where new utilities and services will be installed. Joint trenches for new utilities shall be used whenever possible. 7. Pavement Restoration: Based on the utility coordination plan, the applicant shall prepare a pavement restoration plan for approval by the City Engineer prior to any utility installation or abandonment. Streets that have been reconstructed or overlaid within the previous five years will require boring and jacking for all new utility installations. San Tomas Aquino Road was overlaid in 1999 and reconstructed in FY 2000/0 I. The pavement restoration plan shall indicate how the street pavement shall be restored following the installation or abandonment of all utilities necessary for the project. 8. Grading and Drainage Plan: Prior to issuance of any grading or building permits for the site, the applicant shall conduct hydrology studies based on a ten-year storm frequency, prepare and engineered grading and drainage plan, and pay fees required to obtain necessary grading permits. The plans shall comply with the 1998 edition of the California Building Code including Chapters 10, 11, 18,33, and Appendix Chapter 33. 10. Stormwater Pollution Prevention Measures: Prior to issuance of any grading or building permits, the applicant shall comply with the National Pollution Discharge Elimination System (NPDES) permit requirements, Santa Clara Valley Water District requirements, and the Campbell Municipal Code regarding stormwater pollution prevention. The primary objectives are to improve the quality and reduce the quantity of stormwater runoff to the bay. Resources to achieve these objectives include Stormwater Best Management Practices Handbook for New Development and Redevelopment ("CA BMP Handbook") by the California Stormwater Quality Association (CASQA), 2003; Start at the Source: A Design Guidance Manual for Stormwater Quality Protection ("Start at the Source") by the Bay Area Stormwater Management Agencies Association (BASMAA), 1999; and Using Site Design Techniques to Meet Development Standards for Stormwater Quality: A Companion Document to Start at the Source ("Using Site Design Techniques") by BASMAA, 2003. Rev. 11/03 J:\LandDev\Conditions\Plng\STAR S 1141 PLN 200S.DOC Page 2 of 2