Pre-App - PD - 2006August 2, 2006 Phil Nicholls & Meredith Emmons 1161 Virginia Avenue Campbell, CA 95008 Re: Preliminary Application Comments File No: PRE2006-33 1161 Virginia Avenue Dear Applicant: Thank you for your submittal of a preliminary application for a new four-unit single-family home, planned development project located at the above referenced addresses. The subject property is presently zoned R-D-S (Two-Family District) and is designated as Low-Medium Density Residential (6-13 units per gross acre) on the City's General Plan Land Use Map. The proposed project will require the following application approvals which can be processed concurrently and will require approval from the Planning Commission and City Council through the public hearing process: 1. Zone Change: A Zone Change from R-D-S (Two-Family District) to P-D (Planned Development). 2. Planned Development Permit: A Planned Development Permit will be required to allow the construction of the new homes. The Planned Development Permit approves the site plan, floor plans, elevations, and landscape plan for the subject property. 3. Tentative Parcel Map: In order to subdivide the property with four units, the project will require the approval of a Tentative Parcel Map to subdivide the property into four individual lots and one common lot for common guest parking spaces, driveway, and landscaping. 4. Tree Removal Permit: Any protected trees that are proposed to be removed as part of the project will require the approval of a Tree Removal Permit. The City has Tree Protection Regulations which stipulate that any tree over 12-inches in diameter, measured four feet above grade, is a protected tree. Existing on-site trees that are healthy and can be 70 North First Street Campbell, California 95008-14.36 ~ r~1 408.866.2140 Fnx 408.866.8381 i'[x> 408.866.2790 PRE2006-33 -1161 Virginia Avenue Page 2 of 3 accommodated with a proposed development should be preserved. It is recommended that to the extent possible, you preserve the existing trees on site to better integrate the new project with the neighborhood. The Planning Division completed the review of your preliminary application and has the following comments regarding your proposal: 1. Site Layout & Architecture: The following site layout issues should be incorporated into the project: a. All buildings shall have a minimum 15-foot setback along all property lines, except that garages shall have a minimum 25-foot setback from the public right-of-way. b. For detached units, a side yard setback of five feet should be provided for each unit, for a total of 10 feet total between units. The proposed six-foot separation between the rear units is not adequate. Please provide a minimum of 10 feet between units or attach the units. c. The maximum height in this area is 28 feet, as measured from natural grade, not finished grade. Please ensure that when working with your project engineer on a preliminary grading plan that the height of the units takes into consideration grading for the project site. This may require lowering the height of the units to meet this height limitation. d. Staff recommends using varied exterior building materials and colors for each home to provide architectural interest and variation within the development. 2. Parkin :The Parking and Loading Ordinance requires 3.5 parking spaces per unit for this type of development. All required parking spaces shall be provided on-site and cannot include any on-street parking. Please provide a minimum of 14 spaces for the proposed project, four of which must be covered. 3. Driveway: Please see the enclosed Fire Department comments which stipulate that the minimum paved width for the shared driveway shall be 20 feet. 4. Common Lot: The City will be requiring that the Tentative Parcel Map be designed to have one lot for each unit and one common lot for the shared access driveway, shared guest parking spaces, and common landscaping areas. 5. Dedication: Please see the enclosed Public Works Department comments which require dedication along the project frontage for public street purposes and public street improvements that will be required for development of the project. 6. Park Impact Fee: A park impact fee for each new unit, based on a density range of six to thirteen units per gross acre, shall be paid to the City for the development of the project. PRE2006-33 -1161 Virginia Avenue Page 3 of 3 Credit for one unit shall be given for the existing single-family home on the property to be demolished. The current fee is $9,415 per unit. 7. Open Space: Projects should provide a minimum of 500 square feet of useable private open space per unit. Useable open space shall have a minimum depth of 10 feet. The open space for each unit should be delineated and quantified on the plans. Your pre-application was distributed to the Public Works Department, Building Division, Planning Division, and the Fire Department. In addition to the Planning Division comments contained in this letter, please find enclosed comments from the Building Division, Fire Department, and Public Works Department. Please note that all comments are meant to be preliminary and that conditions of approval from each department will be developed at the time the formal applications are submitted. If you have any questions regarding these comments or the application process, please contact me at (408) 866-2193 or by email at stephaniew@cityofcampbell.com. Sincerely, e~ ~illsu~-- Stephanie Willsey, AICP Planner II Encl: Fire Department Comments, 7/19/06 Building Division Comments, 7/12/06 Public Works Department Comments, 8/2/06 Zone Change Application Planned Development Permit Application Tentative Parcel Map Application Tree Removal Permit Application cc: Jackie Young Lind, Senior Planner David Pruitt, 2185 Rosswood Drive, San Jose, CA 95124