Loading...
ENC2017-00269V CITYCIF CAMPBELL DEPT.OFPUBLICWORKS 70 North First Street Campbell, CA 95008 Ph. (4o8),866-2150 Print Form ENCROACHMENTPERMIT Permit Now (forworkingwithinthepubiic. X-Ref; File right -of way) Application Date l t11041 Issued ((� kc. A 7 Application Expiration Date s f o APN.--2F)21.006'3 L-k2--If Fx. (408.) 376-0958. P:erniif Expiration Date � � G l$, APPLICATION -Application is hereby made fora PublicW6rks Permit In accordance with Campbell'Mu Icipal Code; Section 11.0,4. (Application expires in six (6) months if the permit is not issued., Application Fee is`non-refundable.) A. Work Address or Tract No.: if(�eJ Utility Trench Location- B.. Nature of Work: r t C e• `C. Attach four,(4)copiesof'ane.ngineeredplanshow] ngthe location and extent oftheWork, andfour(4) cop! asofthaprelimina ry Engine er's Estimate of'work.. The plans shall show the relation of the proposed Work to existing surface.and underground Improvements, When approved. by the CityEngineer, said plan becomes a part of this'permit. D. All Work shall conform totheCltyofCampbeiiStandard SpecificationsandDetails for PubiicWorks'Construction,•,theGeneral.Permit.Conditions listed on the reverse side; and the Special -Provisions for this permit;, listed below.. Failure --to abide by these conditions and provisions may result injob shutdown and/or forfeiture"of Faithful Performance Sureties and. cash deposits. E. The Contractor must have this permit and approved plans at, the site and must ,notify the Public Works Departm1.ent at leas two days before startingwork. Notice, must be given toPtiblicWorksatleast24hoursbeforerestarianganywork. Name of Applicant:. t j2C irY1 Q.1 �7- _ _ @, Telephone: O Address: ' E MailAddress;l �- 0@eA� HOUR M RGENCYPHONENUMBER: Is this work being done b the property ���^ ��— g y p p rtyowners atth.eir own residence'? ®`YES ❑ NO The Applicant/Permittee hereby agrees by affixing their signature to, this permit to hold the .City of Campbell; Its officers; agents; and'employees free, safe and harmless from any claim or demand for damages resulting from the work covered by this permit,• The Applicant/Permittee„hereby acknowledges that they have read, and understand both the front and back of this permit;. and they will'inform their contractor(s) of the information, Applicant is 'advised that upon issuance of this' permit, property owner; or property owner's successors, shall be responsible ;for any and all damages arising out of improvements'completed in the pubiic:rigfit-of-way. Accepted: _// ��% 11-7 Permittee). (sign) SPECIAL PROVISIONS:. El 1: Streetshall not be open cut for underground installations. Minimumcutsma_y beallowed for connections or.ezplorationFioles:Such cuts maybe . specifically approved by the Inspector prior to cuttine:, 0 2. Pavement may be;cut for underground installations and must be restored In accordance with the Standard Details Trench Restoration Method, "A", unless otherwise approved by the Engineer. 3. Workto be staked by a licensed Land Surveyor or Civil Engineer and two (2) copies of the cutsheetssent to the Public Works'Department before starting work. ry 4. Per Section 4216 of the Government Code this permit -is not valid for excavations until Underground Service Alert(USA) has been notified and r� the inquiry. identification number has been entered hereon, USA Phone: 1-800-227-2600. USA TICKET NO'. AMOUNT PERMIT APPLICATION FEE $ PLAN CHECK DEPOSIT $ SECURITY FDA FAITHFUL PERFORMANCE/LABOR & MATERIALS $ CONSTRUCTION CASH, DEPOSIT $. PLAN CHECK '&•INSPECTION FEE" EMERGENCY PERMIT FEE, $ APPROVED FOR ISSUANCE - \ For City Engineer Expires 12 Months After:Date'of Issuance 278 V x $ 2.q5/(p) i- V4rt_uN 19a) RECEIPT NO, Q. Date 3 GENERAL PERMIT CONDITIONS 1. The Permittee must provide evidence of insurance and Additional Insured Endorsements as required by City. Insurance shall be maintained for the duration of the permit work. 2. A Construction Cash Deposit is required. Changes will be made against this deposit if there is an emergency call -out, overtime Inspection or when City ordered barricading is required. Any such costs in excess of the deposit will be billed to the Permittee. 3. Refund of the construction cash deposit balance and refund or cancellation of the Faithful Performance Surety will be initiated by the written acceptance of the work by the City. 4. A one-year maintenance period and surety are required. Such period will begin on date of written acceptance by the City. Surety posted shall be equal to 25%of the original Faithful Performance Security. S. Submit project schedule 10 (ten) days prior.to proposed start of work. Additional lead time may be required for work within City facilities and downtown Campbell. 6. The Permittee must request in writing a finalinspection and acceptance of the work upon completion. Acceptance by the City will be made in writing to the Permittee. 7. Maintain safe pedestrian and vehicular crossings and free access to private driveways,.bus stops, fire hydrants, and water valves. 8. A Construction Traffic Control P1an.and a Construction Schedule are required for all lane closures, detours, and street.closures. This plan must be reviewed and approved prior to any lane closures. 9. A Construction Traffic Control Plan shall conform to the2006 California Manual on Uniform Traffic Control Devices (MUTCD). 10. Replace, as directed by the City Engineer, any damaged or removed improvements in accordance with City Standards and Specifications at the sole expense of the Permittee as expeditiously as possible. 11. Sawcut for all PCC or AC removals. All PCC removals shall be to the nearest scoremark and new PCC shall be doweled to existing improvements. 12. Prior approval of inspector Is required for anywork proposed after normal working hours, on weekends or holidays and may require reimbursement of inspection costs at the current overtime rate. 13. Work on arterials and collectors may require the use of changeable message boards. Adequate signing and barricading is required on the job site. Failure to provide such signing and barricading may result in the Ci.ty's providing signing and barricades and charging the cosb(inciuding all labor and materials) againstthe construction cash deposit. 14. Compaction testing of subgrade, base rock, and asphalt concrete by Permittee is required unless otherwise stated by the City Engineer, 15. The Contractor or Permittee will have a supervisory representative available for contact on the project at all times during construction. Contractor orPermittee shall provide a phone numberat which they can be contacted outside the hours of 8:00 a.m. to 4:00 p.m. and on weekends. 16. No storage of materials or equipment will be allowed near the edge ofthe pavement, the traveled way, or within the shoulderline which would create a hazardous condition to the public. 17. This permit shall not be construed as authorization for excavation and grading on private property adjacent to the work or any other work for which a separate permit may be required, nor does it relieve the Permittee of anyobligation to obtain any other permit required by law. 18. This permit does not release the Permittee from any liabilities contained in other agreements or contracts with the City and any other public agency. 19. This permit is not transferable. Work must be performed by the Permittee or his designated agent or contractor as specified thereon. 20. Cali back (call out) due to emergencies regarding this permit shall beat the current overtime rate with a three (3) hour minimum charge per occurrence... 21, Pursuant to Chapter 14.02 of the Campbell Municipal Code, applicant shall not cause to be discharged any material into the municipal storm drain system other than storm water. Applicant shall adhere to the BEST MANAGEMENT PRACTICES established by the Santa Clara Valley Urban Runoff Pollution Prevention Program. 22. If the public interest requires a modification of, or a departure from the permit, plans, special provisions and/or specifications, the City shall have the authority to require or approve any modification or departure and to specify the manner in which the same is to be made. 23. Permittee must provide advance notification to all parties that may be affected by the permit activities. Notification shall be reviewed by the City prior to distribution and include dates of work and a contact name and a phone number. 24. Applicant shall remove water from utility vaults in accordance with the requirements of State Water Resources Control Board Water Quality Order WQ 2014-0174- DW4 Said vault water shall not be discharged into the City of Campbell's storm drain system. See http://anmv.waterboards.ca.gov/water issues/programs/nodes/utilitvvaults shtml for more information, Applicant is hereby responsible for ensuring that all those providing services under the applicant are aware of and abide by all of the above conditions. :Fkkv Kfk. _2AVVLO rct Contractor (Print Name) 1:\FORMS\Templates\Encroachment Permits\Encroachment Permit STATIC form2.pdf Rev.03/17 1C--(:)q-1 j' Date: 1_7 Date: mcast CALIFORNIA DIVISION BAY AREA PLANNING & ARCHITECTURE . PERMIT DEPT 3055 COMCAST PLACE, LIVERMORE, CA 94551 BORE ��® 9?g Q of 2045 S. BASCOM "E 10 , so CAMPBELLCALIFORMI �' ` G 1° ;om PROJECT ID: 256966 ®� ,06 y ®$ ®'� @elm � 91►c • DRAWING INDEX SHT NO. DESCRIPTION 1 TITLE PAGE 2 LEGEND & GENERAL NOTES 3 STORM WATER PROTECTION PLAN 4 LAYOUT 5 TRAFFIC CONTROL 6 TRAFFIC CONTROL LEGEND 7 VAULT DETAILS 8 BORE PIT DETAILS Ccomcast IMPORTANT NOTICE a Section $ 4216/4217 of the Government Code requires a Dig Alert Identification Number to be issued before a 'Permit to Excavate' will. he volid For your Dig Alert I.D. THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2045 S. BASCOM AVE TITLE PAGE DESIGN: DRAWN BY: JC REV DESCRIPTION DATE 0 ISSUE FOR PERMIT 11/06/2017 PROJ#: 256966—WORKPLACE RE CALIFORNIA DIVISION BAY AREA PLANNING & ARCHITECTURE — PERMIT DEPT 3055 COMCAST PUCE. LIVERMORE, CALIFORNIA 94551 CALL TOLL FREE 48 HOURS BEFORE YOU DIG UNDERGROUND SERVICE ALERT 1-800-227-2600 APPROVED: APPROVED: APPROVED: CONSTRUCTION TYPE: BORE SYSTEM: CAMPBELL NODE: SHEET: 1 OF 8 -ZVX4RC)T Q 0 TRANSFORMER ® NEW COMCA5T POWER SUPPLY STREET LIGHT ME] NEW COMCAST LOW PROFILE POWER SUPPLY W/ METER TRAFFIC SIGNAL COMBINATION 0 NEW COMCAST VAULT O FIRE HYDRANT ® NEW COMCAST PEDESTAL _ ® BORE PIT � MONUMENT ® CATCH BASIN EXISTING RISER POLE ® STORM DRAIN MANHOLE ® EXISTING POLE Qw WATER MANHOLE � EXISTING COMCAST VAULT ® SANITARY SEWER MANHOLE ® EXISTING COMCAST PEDESTAL ® SEWER CLEAN OUT 0 EXISTING IRRIGATION VAULT Q ELECTRIC MANHOLE 0 EXISTING UTILITY VAULT/PEDESTAL ® UNIDENTIFIED MANHOLE LuJ GAS/WATER VALVE ® WATER METER TREE/BUSHES 0 GAS METER ABBREVIATIONS COMCAST COMCAST PL PROPERTY LINE G. CENTER UNE PUE PUBLIC UTILITY EASEMENT (E) EXISTING ROW RIGHT OF WAY FOC FACE OF CURB SO EXISTING STORM DRAIN MIN MINIMUM SS EXISTING SANITARY SEWER MAX MAXIMUM T EXISTING TELEPHONE CDT CONDUIT W EXISTING WATER S /R OFFSET BOW BACK OF OF WALK RAY REMOVAL -REPAIR T TATT7TV1)VQ — CATV — NEW STRAND/CABLE ROUTE — — — — — — — — PROPOSED BORE/TRENCH ROUTE TV EXISTING COMCAST ROUTE T EXISTING TELEPHONE SYSTEM E EXISTING ELECTRICAL SYSTEM a EXISTING GAS SYSTEM TV EXISTING TV SYSTEM IRR EXISTING IRRIGATION SYSTEM 3T EXISTING JOINT BORE ss EXISTING SANITARY SEWER so EXISTING STORM DRAIN IN EXISTING WATER LINE x x x EXISTING FENCELINE — - — - — - — - — - — - — - — - — - — ROADWAY CENTER LINE — — — — PROPERTY LINE (P/L) — — — — RIGHT OF WAY (ROW) GENERAL NOTES 1. ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS. 2. CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 HOURS (AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION BY CALLING (800) 227-2600. 3. CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES PRIOR TO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON PLANS ARE APPROXIMATE, CONTRACTOR MUST VERIFY. 4. CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OF CONSTRUCTION. ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE. 5. CONTRACTOR SHALL KEEP A COPY OF APPROVED PLAN(S) AND PERMITS) AT THE JOB SITE AT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY OF CAMPBELL AND/OR LAW ENFORCEMENT UPON REQUEST. 6. CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED SHALL BE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO REPLACING EXISTING STRIPING AND REMOVING UNNECESSARY 'USA' MARKINGS. 7. CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISE APPROVED IN WRITING BY THE 'CITY ENGINEER.' 8. CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE WITH THE CITY OF CAMPBELL AND STATE OF CALIFORNIA STANDARD PLANS AND SPECIFICATIONS, AND CURRENT CALIFORNIA DEPARTMENT OF TRANSPORTATION 'MANUAL OF TRAFFIC CONTROLS AND MAINTENANCE OF HAZARD ZONE' AND 'MANUAL OF WARNING SIGNS, LIGHTS AND DEVICES' FOR USE IN PERFORMANCE OF WORK UPON HIGHWAYS. FLASHING ARROW SIGNS SHALL BE REQUIRED FOR ALL LANE CLOSURES. S. CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITH REGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVING JURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE STATE OF CALIFORNIA PUBLIC UTILITY COMMISSION (CPUC), THE STATE OF CALIFORNIA OCCUPATIONAL SAFETY AND HEALTH ACT (CAL OSHA), THE COUNTY OF SANTA CLARA. ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TO INSPECTION BY CITY ENGINEER AND/OR AN AUTHORIZED AGENT OF COMCAST. 10. CONTRACTOR SHALL 'RED-UNE' ALL LAYOUTS, PLANS AND DETAILS, ON THE DAY OF CONSTRUCTION AND SUBMIT A COMPLETE SET OF 'AS -BUILT' PLANS TO COMCAST UPON COMPLETION OF THE PROJECT, AND TO CITY. 11. CONTRACTOR SHALL NOTIFY RESIDENTS AFFECTED BY THE WORK IN LANDSCAPED AREA IN ADVANCE OF CONSTRUCTION. 12. CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE CF WORK COMMENCING. 13. LANE CLOSURES ARE PROHIBITED BEFORE 8:30 AM AND AFTER 4:00 PM (3:00 PM CF FRIDAYS AND ON DAYS PRECEEDING DESIGNATED LEGAL HOLIDAYS). NO LANE CLOSURES ARE PERMTTED ON WEEKENDS AND HOLIDAYS. CAMPBELL, CALIFORNIA PROPOSED �PR41E4°T' PROIYiS TO BO$E `78 TO ~ IISiAON C?P ;(2) 2'1i�[14P„„ _ CQ]OUITs' RAT€TG 4TROl CONTACTS THIS PROJECT IS NECESSARY TO MAINTAIN THE KEVIN SMITH COMCAST CABLE SYSTEM OPERATIONAL AND TO PERMIT MANAGER UPGRADE OUR SERVICES OF DIGITAL CABLE TELEVISION, CABLECOM DIGITAL TELEPHONE, AND HIGH SPEED DATA FOR OUR (707) 580-4418 CUSTOMERS IN THE CITY OF CAMPBEH FALYNN ZAMORA PERMIT COORDINATOR CAB LECOM (408) 206-1647 Ccomcast IMPORTANT NOTICE Section # 4216/4217 of the Government Code requires a o Dig Alert Identification Number to be issued before a 'Permit to Excavate` will be valid For your Dig Alert I.D. THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2045 S. BASCOM AVE LEGEND &GENERAL NOTES DESIGN: DRAWN BY: JC REV DESCRIPTION DATE 0 ISSUE FOR PERMIT 11/06/2017 PROD#: 256966-WORKPLACE RE CALIFORNIA DIVISION BAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT 3U55COMCAST PLACE. LIVERMORE, CAUFORNIA 96551 CALL TOLL FREE 48 HOURS BEFORE YOU DIG UNDERGROUND SERVICE ALERT 1-800-227-2600 APPROVED: APPROVED: APPROVED: CONSTRUCTION TYPE: BORE SYSTEM: CAMPBELL - NODE: SHEET: 2 OF 8 STORM WATER PROTECTION PLAN GRAVEL BAG(S) OR OTHER ACCEPTED SEDIMENT CONTROL BMP. PLACE BAGS TIGHT AGAINST FACE OF CURB. BACKOFCURB NOTE 2 FLOW �e SLIP OF GUTTER DRAINAGE INLET WITH FILTER BAG NOTES: PLAN VIEW 1.) SEDIMENT TRAPPED UPSTREAM OF SEDIMENT CONTROL BMP SHALL BE REMOVED WEEKLY AND PRIOR TO RAINFALL EVENT. 2) PLACE BMPS TIGHTLY TOGETHER AT JOINTS TO PREVENT OR MINIMIZE SEEPAGEAT JOINTS. INLETSEDIMENT CONTROL 3B GA (141 MIN. ' L 25 MM 111 MIN STRAW BALES _ STRAWSALES 450 AB4 WMB POLYETHYIFNE (1B1 WN L50 ADA (1r)MIN. 50X50 MM lY%2'1 A Mum SiAXE5ORtl4 J-BARS MIN - 2PERBALETYP. AREA 7 SECTION A -A --- SIGN 6DO MM (241 MIN BALE CONFIGURATION F, - THIS SECTION REMOVED FOR GRAPNCAL REPRESENTATION NOTES: ONLY. STRAWBAIEPEROAEIER 1.1FACE SIGN TOWARD NEAREST STREET OR SHAU.BECONTINUOUS " ACCESSPOINT. CONCRETE WASHOUT 2)CONCRETE WASHOUT SHALL BE LOCATED BEHIND THECURBAND 15 M (SOFT.) - MINIMUM FROM DRAINAGE INLETS OR WATERCOURSES FILTER BAG FILTER BAG PLACEMENT AT TYPE PLACEMENT AT TYPE NOTES B AND E DROP INLETS A, C, D, & F DROP INLETSL�;,a,E„u,,,Eo AND PARKING LOTS "+ EXISTING OPEN 5 CM <2'> 2,*xEr�Lhae+o suueE wwurAc}ua® HACK HOD DETAIL A EXISTING DROP ovnExE: xnox, MINIMUM INLET GRATE F5v P DAM DETAIL A CURB � ru�axsvinuT�rr. a. .. 3.TxE LTEa ana Luv BE susaExom NvoN MINIMUMa w,tE(rn oiHERMPFw®YwEII IReTWD} BAG vIDTH ooxeatT�ocaAresx+u �eEE 5 CM (a.?: (BACK OF rCONTACT a io AEsruoeenux(auu(5T MINIMUM GRATE) AT FRONT AawETxE�xui FlaME(sEEOErAaA} AT BACK — CONTACT, (PLOD AND SI➢ES ALL SIDE 4.—ErERancuArM m� m RELEASE) aTrtET PPE isurwasla g o. ra MINIM 5 PLoxsaw.L xoT�AU.enmiO-0 THE IE— BAG DEPTH Ex :l sxavm Pox noaoaa�si OUTLET PIPE bIHIET FllTE3 GosaxxueEiNSPccTm OUTLET PIPE DETAIL A Eaeiss�uuE EXISTING DROP T—I.3 CM (.5') xAve INLET GRAT + MAXIMUM saaxAsauaceoccuas EPunmAs y STORM DRAIN INLET FILTER B FILTER BAG FRAME E%ISTING DROP (OPTIONAL5 INLET FRAME IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2045 S. BASCOM AVE . Ccomcast DESIGN: REV DESCRIPTION DATE STORM WATER PROTECTION PLAN Section # 4216/4217 of the Government Code requires a 0 ISSUE FOR PERMIT 11/O6/2017 Dig Alert Exca ficdlian Number to be Issued before I. DRAWN BY: JC 'Permit to Ezcavale' will be valid For your Dig Alert I.D. PROJ#: 256966—WORKPLACE RE CALL TOLL FREE APPROVED: CONSTRUCTION TYPE: BORE CALIFORNIA DIVISION 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE — PERMIT DEPT UNDERGROUND SERVICE ALERT - SYSTEM: CAMPBELL 3055 CONICAST PLACE LIVERMORE, CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: SHEEL• 3 OF 8 61 W O O W ® U SCALE: 1:40 o 0 O o W aw 1S J - LANDSCAPING D1w SIDEWALK BIKE LANE FOC ........................ a ir O O + + O 0 C` O O 00 Cl E92 + i+ +-4— --1•— _ M' N N +_ _ O N N aanL= 0- - W V N m N N S BASCOM AVE ,dam N• W BIKE LANE LANDSCAPING \ DAV BUS DAN STOP SIDEWA -+ DAV DAY SIDEWALK y\ BORE B 3' X 3' BORE PR O/S 4' BOW STREET UGHT O/S 2 {' ,WATER METER O S 2' PACBELL VAULVAULTT O/S 6 fS 2' l - 8' , SEWER VAULT O/S 10' BORE TO TARGET I PG&E VAULT O/S 9' WATER METER O/S 2' HYDRANT O/S 2' WATER METER O/S 2' W aW WATER VAULT O/S 12' I Q� TRAFFIC SIGNAL 0/S 2' DRAIN INLET TwFrT3 SIGNAL O/S 2' a (q. CAN VAULT O/S 3' PG&E VAULT O/S 8' 3' X 3 BORE PIT O/S 4' IW WATER VAULT 0/S 12' TELEPHONE VAULT O/S 8' �° I1 m IN57AL►� Nb`w 905 TOST (3E+H (ND IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2045 S. LiASCOM AVE Ccomcast DESIGN: REV DESCRIPTION DATE LAYOUT Section # 4216/4217 of the Government Code requires a 0 ISSUE FOR PERMIT 11 /06/2017 Dig Alert Identification Number to be issued before I. DRAWN BY: JC PROJ : 256966—WORKPLACE RE 'Permit to Excavate will be valid For your Dig Alert I.D. CALL TOLL FREE APPROVED: CALIFORNIA DIVISION 48 HOURS BEFORE YOU DIG CONSTRUCTION TYPE: BORE BAY AREA PLANNING & ARCHITECTURE — PERMIT DEPT UNDERGROUND SERVICE ALERT APPROVED: SYSTEM: CAMPBELL 3055 COMCAST PLACE. LIVERMORE, CALIFORNIA 94551 1-800-227-2600 APPROVED: - NODE: SHEET: 4 OF 8 y NOTE 3 W INSTALL TEMPORARY NO PARKING y SIGNS 48 HOURS PRIOR TO START OF WORK. - ROAD WORK ACCESS TO DRIVEWAYS WILL BE GIVEN AT ALL TIME DURING CONSTRUCTION W20-1 ALL LANES SHOULD BE A MINIMUM OF 10' IN WIDTH AS MEASURED TO THE NEAR FACE OF THE CHANNELIZING DEVICES. v® V BOW DAN DAN SIDEWALK \ a PIKFI N� FOC 10' MIN. 250, .. �. I ANI1Gf:APINr. N W y DAY o w • W o w o y IMP - SCALE: N.T.S DM W� dOiS BOW LANDSCAPING DMr SIDEWALK BIKELANE FOC S. BASCOM AVE 35 MPAU BUS _.., Tuff I — ® I ..... I..... M p VAHEAD I W 0 3 I NI IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT. PROPRIETARY h CONFIDENTIAL 2045 S. BASCOM AVE Ccomcast DESIGN: REV DESCRIPTION DATE TRAFFIC CONTROL Section # 4216/4217 of the Government Code requires a 0 ISSUE FOR PERMIT 11/06/2017 Dig Alert Identification Number to be issued before a DRAWN BY: JC 'Permit to Excavate' will be valid For your Dig. Alert LD, PROD#: 256966-WORKPLACE RE CALL TOLL FREE APPROVED: CALIFORNIA DIVISION 48 HOURS BEFORE YOU DIG CONSTRUCTION TYPE: BORE BAY AREA PLANNING dr ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT APPROVED: SYSTEM: CAMPBELL 3055 COMCAST PUCE LIVERMORE, CALIFORNIA94551 1-800-227-2600 APPROVED: NODE: SHEET: 5 OF 8 LEGEND • Traffic Cone or Delineator' �- Sign Direction of Travel ( Not a pavement marking ) Flashing Arrow Sign (Where Required) Refer to. Page 7 of Caltrans manual Type A, Type I , or Type II . Y High Level Warning Device (Flogtree) Barricade (For Excavation Only) Refer to Page 12 of Caltrans manual to select for Details on Type I , Type II , or Type III . it Flogger NOTES: 1. Flaggers will be used to control traffic at non —signalized intersections. Flaggers Will use 2 way radios when a 24' (min) roadway cannot be maintained. 2. No Parking/Tow Away signs will be posted 48 hours in advance to clear work zone. 3. All construction zone signs/directional signs will conform to Caltrans specs. Signs will be spaced 150 feet apart where applicable. 4. Some traffic control plan will apply at other similar locations and opposite side of street. 5. Use flag trees on all C-18/C-23 signs. ROAD SHOULDER END tROAD WORK1-1AHEADW20-1 W21-5 G20-2 6-1P 6H-3 ROAD TYPE DISTANCE. BETWEEN SIGNS ** A B C URBAN- 25MPH OR LESS-- 100 FEET 100 FEET 100 FEET URBAN- MORE THAN 25 MPH TO 40 MPH- 250 FEET 250 FEET 250 FEET URBAN- MORE THAN 40 MPH*" 350 FEET 350 FEET 350 FEET •RURAL, 500 FEET 500 FEET _ 500 FEET EXPRESSWAY/FREEWAY 1,000 FEET 1.500 FEET 2,640 FEET (*«) THE COLUMN HEADINGS A, B, AND C ARE THE DIMENSIONS SHOWN IN FIGURES 6H-1 THROUGH 6H-46. THE A DIMENSION IS THE DISTANCE FROM THE TRANSITION OR POINT OF RESTRICTION TO THE FIRST SIGN. THE B DIMENSON S THE DSTANCE BETWEEN THE FIRST AND SECOND SIGNS. THE C DIMENSION IS THE DISTANCE BETWEEN THE SECOND AND THIRD SIGNS. (THE "FIRST SIGN" IS THE SIGN IN A THREE -SIGN SERIES THAT IS CLOSEST TO THE TTC ZONE. THE "THIRD SIGN" IS THE SIGN THAT IS FURTHEST UPSTREAM FROM THE TTC ZONE.) ('«*) POSTED SPEED LIMIT, OFF PEAK 85TH-PERCENTILE SPEED PRIOR TO WORK STARTING, OR OTHER OPERATING SPEED IN MPH 6H-4 SPEED LIMIT(S) TAPELENGTH (L) SPEED LIMITS) LENGTH (L) METERS FEET 60 km/h OR LESS L=WS' 40 MPH OR LESS L=WS- 70 km/h OR MORE i55 L=WS, 45 MPH OR MORE 60 L=WS 1.6 WHERE: L= TAPER LENGTH IN METERS (FEET) W=WIDTH OF OFFEST IN METERS (FEET) S=POSTED SPEED LIMIT, OR OFF—PEAK 85TH PERCENTILE SPEED PRIOR TO WORK STARTING, OR THE ANTICIPATED OPERATING SPEED IN KM/H (MPH) IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY &. CONFIDENTIAL 2045 S. BASCOM AVE Ccomcast DESIGN: REV DESCRIPTION DATE TRAFFIC CONTROL LEGEND Section $ 4216/4217 of the Govemment Code requires a 0 ISSUE FOR PERMIT 11/O6/2017 Dig Alert Identification Number to be Issued before a DRAWN BY: JC. "Permit to Excavate" will be valid For your Dig Alert I.D. PRWjj: 256966-WORKPLACE RE CALL TOLL FREE APPROVED: CAUFORNIA DIVISION 48 HOURS BEFORE YOU DIG CONSTRUCTION TYPE BORE DIVISIONBAY AREA PLANNING & ARCHITECTURE - PERMIT DEPT UNDERGROUND SERVICE ALERT APPROVED: SYSTEM: CAMPBELL 3055 COMCAST PUCE LIVERMORE, CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: SHEET: 6 OF 8 A HIGH DENSITY REINFORCED CONCRETE BOX, WITH NON —SETTLING SHOULDERS POSITIONED TO MAINTAIN GRADE AND FACILITATE BACKFI W NG. APPROXIMATE DIMENSIONS SHOWN. SCALE N.T.S. ^ IMPORTANT NOTICE THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2045 S. BASCOM AVE CC O C DESIGN: REV DESCRIPTION DATE VAULT DETAILS `V- J Section # 4216/4217 of the Government Code requires a 0 ISSUE FOR PERMIT 11/06/2017 Dig Alert Identification Number to be issued before I. -DRAWN BY: JC 'Permit to Excavate` will TO valid For your Dig Alert I.D. PR0,1$: 256966—WORKPLACE RE CALL TOLL FREE APPROVED: CONSTRUCTION TYPE BORE CALIFORNW DIVISION 48 HOURS BEFORE YOU DIG APPROVED: BAY AREA PLANNING & ARCHITECTURE — PERMIT DEPT UNDERGROUND SERVICE ALERT SYSTEM: CAMPBELL 3065 COMCAST PLACE. LIVERMORE. CALIFORNIA 94551 1-800-227-2600 APPROVED: NODE: SHEET: 7 OF 8 E) CURB & SIDEWALK BORE DEPTH SHALL BE BELOW SANITARY SEWER MAIN TO CLEAR ALL UTILITY 11x3' BORE/ ;ECEIVING PIT FRENCH ZESTORATION PER ;ITY OF CAMPBELL -2" CONDUIT BORE PIT DETAIL SCALE: N.T.S. Ccomcast o IMPORTANT NOTICE Section # 4216/4217 of the Government Code requires a �P Dig F--+^tioWi1Number iw irbe issued, before a THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL 2045 S. DASCOM AVE DORE PIT DETAILS DESIGN: DRAWN BY: JC REV DESCRIPTION DATE 0 ISSUE FOR PERMIT 11/O6/2017 PROJB: 256966-WORKPLACE RE