Loading...
PC Res 3720 RESOLUTION NO. 3720 BEING A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF CAMPBELL APPROVING SITE AND ARCHITECTURAL REVIEW PERMITS (PLN2006-03 & PLN2006- 04) TO ALLOW THE CONSTRUCTION TWO NEW TWO-STORY SINGLE FAMILY RESIDENCES ON PROPERTY OWNED BY MR. BASHEER AHMED LOCATED AT 1690 & 1692 WESTMONT AVENUE IN AN R-1-9 (SINGLE FAMILY RESIDENTIAL) ZONING DISTRICT. APPLICATION OF MR. BASHEER AHMED. FILE NO.: PLN2006-03 & PLN2006-04. After notification and public hearing, as specified by law and after presentation by the Community Development Director, proponents and opponents, the hearing was closed. After due consideration of all evidence presented, the Planning Commission did find as follows with respect to application PLN2006-03 & PLN2006-04: 1. The density of the residential project will result in a density of 3.5 units per gross acre for the front lot and 3.2 units per gross acre for the rear lot, which is consistent with the General Plan land use designation of Low Density Residential (less than 3.5 units per gross acre). 2. The project is consistent with the R-1-9 (Single-Family Residential, 9,000 square foot minimum lot size) zoning district and meets the minimum setbacks, height restriction, building coverage, floor area ratio, and parking requirements of the R-1-9 Zoning District. 3. The project is consistent with the development standards and design guidelines of the San Tomas Area Neighborhood Plan. 4. The residence on the front parcel consists of a new 4,842 square foot, two-story single-family residence with a building coverage of 33%, and a Floor Area of 44.6%. 5. The residence on the rear parcel consists of a new 5,144 square foot, two-story single-family residence with a building coverage of 31 %, and a Floor Area of 42.2%. 6. The height of the residence on the front parcel is 24 feet, 8 inches where the maximum height limit is 28 feet. 7. The height of the residence on the rear parcel is 27 feet where the maximum height limit is 28 feet. 8. The residence on the front parcel incorporates representative architectural features of the San Tomas Neighborhood including simple rectangular shaped forms, simple hipped roofJines, front porch, three-car attached garage, composition shingle roofing material, and an exterior of horizontal siding and brick veneer wainscoting. Planning Commission Resolution No. 3720 PLN2006-03 & PLN2006-04 -- 1690 & 1692 Westmont Avenue Site and Architectural Review Permits - Two New Two-Story Single-Family Residences Page 2 9. The residence on the rear parcel incorporates representative architectural features of the San Tomas Neighborhood including simple rectangular shaped forms, simple hipped and gabled roofJines, front porch, three-car attached garage, composition shingle roofing material, and exterior of stucco siding and cultured stone wainscoting. 10. The proposed project is surrounded by single-family residential uses on the north, south, east, and west. 11. The project provides three covered and two uncovered parking spaces on the front parcel and three covered and three uncovered on the rear parcel where a minimum of one covered and one uncovered parking space is required on each parcel. 12. The project qualifies as a Categorically Exempt project per Section 15303, Class 3, of the California Environmental Quality Act (CEQA). Based upon the foregoing findings of fact, the Planning Commission further finds and concludes that: 1. The proposed project is consistent with the City of Campbell General Plan and Zoning Ordinance. 2. The proposed project, as conditioned, will aid in the harmonious development of the immediate area. 3. The proposed project is well designed and is architecturally compatible with the surrounding neighborhood. 4. No substantial evidence has been presented from which a reasonable argument could be made that shows that the project, as currently presented and subject to the required conditions of approval, will have a significant adverse impact on the environment. 5. The proposed development will not be detrimental to the health, safety or welfare of the neighborhood or the City as a whole. 6. The proposed project will contribute to the housing stock in the City of Campbell and serve the housing needs of the community. 7. There is a reasonable relationship between the use of the fees imposed upon the project and the type of development project. There is a reasonable relationship and a rough proportionality between the conditions of approval and the impacts of the project. Planning Commission Resolution No. 3720 PLN2006-03 & PLN2006-04 -- 1690 & 1692 Westmont Avenue Site and Architectural Review Permits - Two New Two-Story Single-Family Residences Page 3 THEREFORE, BE IT RESOLVED that the Planning Commission approves Site and Architectural Review Permits (PLN2006-03 & PLN2006-04) to allow the construction of two new two-story single-family residences on property owned by Mr. Basheer Ahmed located at 1690 & 1692 Westmont Avenue in an R-1-9 (Single Family Residential) Zoning District, subject to the following conditions: Where approval by the Director of Community Development, City Engineer, Public Works Director, City Attorney or Fire Department is required, that review shall be for compliance with all applicable conditions of approval, adopted policies and guidelines, ordinances, laws and regulations and accepted engineering practices for the item under review. Additionally, the applicant is hereby notified that he/she is required to comply with all applicable Codes or Ordinances of the City of Campbell and the State of California that pertain to this development and are not herein specified. COMMUNITY DEVELOPMENT DEPARTMENT Planning Division: 1. Approved Proiect: Approval is granted for a Site and Architectural Review Permit (PLN2006-03 & 04) to allow the construction of a two new two-story single-family residences located at 1690 & 1692 Westmont Avenue. The building design and site design shall substantially conform to the project exhibits listed below, except as may be modified by the conditions of approval herein: a. Project plans stamped as received by the Planning Division on May 1, 2006 including a site plan, floor plan, and elevations. b. Color/material board stamped as received by the Planning Division on May 1, 2006. c. Color front elevations stamped as received by the Planning Division on May 15, 2006. 2. Architectural Details: Prior to issuance of building permits, the applicant shall provide details of the building materials including, but not limited to, a decorative garage door to the Community Development Director for review and approval. Additional architectural details include: a. The applicant shall reduce the size of the second floor deck on the front parcel (1690 Westmont Avenue) to eliminate privacy impacts on the adjacent properties. The revised deck design shall be indicated on the building permit plans and shall be reviewed and approved by the Community Development Director prior to the issuance of building permits. b. The applicant shall increase the diameter of the front porch columns on the front parcel (1690 Westmont Avenue). The design shall be indicated on the building Planning Commission Resolution No. 3720 PLN2006-03 & PLN2006-04 -- 1690 & 1692 Westmont Avenue Site and Architectural Review Permits - Two New Two-Story Single-Family Residences Page 4 permit plans and shall be reviewed and approved by the Community Development Director prior to the issuance of building permits. c. The applicant shall eliminate the small arched window above the garage on the rear parcel (1692 Westmont Avenue) and provide a small arched attic vent. The attic vent shall be indicated on the building permit plans and shall be reviewed and approved by the Community Development Director prior to the issuance of building permits. d. The applicant shall modify the large window on the left elevation proposed for a second-floor closet so it does not offer views onto the adjacent residence in order to preserve that neighbor's privacy. 3. Approval Expiration: The Site and Architectural Review Permit approval shall be valid for a period of one year from the date of final approval. Within this one-year period, a building permit must be obtained for each new residence or the Site and Architectural Review Permit shall be void. 4. Fences: Any existing or new fencing shall comply with Section 21.18.060 of the Campbell Municipal Code. Fencing along the property lines shall be replaced with a new fence at the expense of the applicant, unless it is determined to be in good condition by the Community Development Director. 5. Property Maintenance: The property is to be maintained free of any combustible trash, debris and weeds until the time that actual construction commences. All existing structures shall be secured by having windows boarded up and doors sealed shut, or be demolished or removed from the property (Section 11.201 and 11.414,1985 Ed. Uniform Fire Code.) 6. Parkinq and Drivewavs: a. All parking and driveway areas shall be developed in compliance with the approved plans and Chapter 21.28 (Parking and Loading) of the Campbell Municipal Code. b. The applicant shall provide a decorative paving treatment within the driveway for the front parcel and within the flag lot stem and driveway for the rear parcel. The design and materials used for the decorative pavement shall be indicated on the building permit plans and shall be reviewed and approved by the Community Development Director prior to the issuance of building permits. 7. Final Parcel Map: The Site and Architectural Review Permit approval is contingent upon recordation of the Final Parcel Map to divide the subject property. The Final Parcel Map shall be recorded prior to the issuance of building permits. Planning Commission Resolution No. 3720 PLN2006-03 & PLN2006-04 -- 1690 & 1692 Westmont Avenue Site and Architectural Review Permits - Two New Two-Story Single-Family Residences Page 5 8. Park Impact Fee: A park impact fee, based on a density range of less than six units per gross acre, is due upon development of the site. Credit shall be given for any existing single-family residence to be demolished. Prior to recordation of the Parcel Map, 75% of this fee is due. The remaining 25% is due prior to issuance of a certificate of building occupancy. 9. Landscape Plan: Prior to the issuance of building permits, the applicant shall submit a final detailed landscape and irrigation plan to the Planning Division for review and approval by the Community Development Director. The landscape and irrigation plan shall substantially conform to the approved conceptual landscape plan and the City's Water Efficient Landscaping Standards (WELS) and shall include the replacement tree as required for the Tree Removal Permit (PLN2006-32). All landscaping and trees shall be installed prior to the issuance of a Certificate of Occupancy for the homes. 10. Tree Protection Plan: The applicant shall submit a tree protection plan for all protected trees to be retained on site and shall contain specific information about the preservation of the trees during and grading or building on site. Such tree protection measures shall be installed prior to any demolition, grading, or building on the project site. No construction or trenching shall take place within the drip line of trees and a fence constructed of temporary cyclone fencing or wire mesh securely attached to poles driven into the ground shall be installed around the dripline of the tree. All trimming or branch removal from protect trees shall be completed by a certified arborist. The tree protection plan shall be submitted to the Planning Division for review and approval by the Community Development Director prior to the issuance of building permits. 11. Utilities: All new on-site utilities shall be installed underground per section 21.18.140 of the Campbell Municipal Code. 12. On-Site Liqhtinq: On-site lighting shall be shielded away from adjacent properties and directed on site in compliance with Section 21.18.090 of the Campbell Municipal Code. Lighting fixtures shall be of a decorative design to be compatible with the residential development and shall incorporate energy saving features. 13. Construction Hours: Construction activities shall be limited to the hours of 8:00 a.m. to 5:00 p.m. weekdays and 9:00 a.m. to 4:00 p.m. Saturdays. Construction is prohibited on Sundays and Holidays unless an exception is granted by the Building Official. 14. Roof Vents: The applicant shall coordinate mechanical and equipment improvement plans to minimize the number of roof vents that are visible from the street frontage. The applicant shall submit detailed mechanical plans demonstrating the clustering of Planning Commission Resolution No. 3720 PLN2006-03 & PLN2006-04 -- 1690 & 1692 Westmont Avenue Site and Architectural Review Permits - Two New Two-Story Single-Family Residences Page 6 mechanical venting and the routing of ventilation systems within the building when possible to the satisfaction of the Community Development Director, prior to the issuance of building permits. 15. Contractor Contact Information Postinq: Prior to the issuance of building permits, the project site shall be posted with the name and contact number of the lead contractor in a location visible from the public street. Building Division: 16. Permits Required: A building permit application shall be required for the proposed new single-family dwelling structure. The building permit shall include Electrical/Plumbing/Mechanical fees when such work is part of the permit. 17. Construction Plans: The conditions of approval shall be stated in full on the cover sheet of construction plans submitted for building permit. 18. Size of Plans: The size of construction plans submitted for building permits shall be 24 inches by 36 inches. 19. Plan Preparation: This project requires plans prepared under the direction and oversight of a California licensed Engineer or Architect. Plans submitted for building permits shall be "wet stamped" and signed by the qualifying professional person. 20. Soils Report: The applicant shall submit two copies of a current soils report containing foundation and retaining wall design recommendations, prepared to the satisfaction of the Building Official, with the building permit application. This report shall be prepared by a licensed engineer specializing in soils mechanics. 21. Site Plan: Application for building permit shall include a competent site plan that identifies property and proposed structures with dimensions and elevations as appropriate. Site plan shall also include site drainage details. 22. Foundation Inspection: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project building inspector upon foundation inspection. This certificate shall certify compliance with the recommendations as specified in the soils report and the building pad elevation and on-site retaining wall locations and elevations are prepared according to approved. Plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered civil engineer for the following items: e. pad elevation f. finish floor elevation (first floor) g. foundation corner locations Planning Commission Resolution No. 3720 PLN2006-03 & PLN2006-04 -- 1690 & 1692 Westmont Avenue Site and Architectural Review Permits - Two New Two-Story Single-Family Residences Page 7 23. Title 24 Enerav Compliance: California Title 24 Energy Compliance forms CF-1 R and MF-1 R shall be blue-lined on the construction plans. 8Yz X 11 calculations shall be submitted as well. 24. Special Inspections: When a special inspection is required by U.B.C. Section 1701, the architect or engineer of record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the building permits, in accordance with U.B.C Section 106.3.5. Please obtain City of Campbell, Special Inspection forms from the Building Inspection Division Counter. 25. Non-Point Source Pollution Control: The City of Campbell standard Santa Clara Valley Non-point Source Pollution Control Program specification sheet shall be part of plan submittal. The specification sheet (size 24 inches by 36 inches) is available at the Building Division service counter. 26. P.G.&E.: The applicant is advised to contact P.G.&E. as early as possible in the approval process. Service installations, changes and/or relocations may require substantial scheduling time and can cause significant delays in the approval process. The applicant should also consult with P.G.&E. concerning utility easements, distribution pole locations and required conductor clearances. 27. Construction Fencinq: This project shall be properly enclosed with construction fencing to prevent unauthorized access to the site during construction. The construction site shall be secured to prevent vandalism and/or theft during hours when no work is being done. All protected trees shall be fenced to prevent damage to root systems. 28. Proiect Approvals: The project requires the following agency approval prior to issuance of the building permit: a. West Valley Sanitation District (378-2407) b. Santa Clara County Fire Department (378-4010) c. Bay Area Air Quality Management District (demolitions only) d. School Districts: i. Campbell Union School District (378-3405) ii. Campbell Union High School District (371-0960) iii. Moreland School District (379-1370) iv. Cambrian School District (377-2103) Note: To determine your district, contact the offices identified above. Obtain the school district payment form from the City Building Division, after the Division has approved the building permit application. Planning Commission Resolution No. 3720 PLN2006-03 & PLN2006-04 -- 1690 & 1692 Westmont Avenue Site and Architectural Review Permits - Two New Two-Story Single-Family Residences Page 8 PUBLIC WORKS DEPARTMENT 29. Previouslv Conditioned Parcel Map: This site has an existing approval for a tentative parcel map (PLN 2005-050). Prior to issuance of any grading or building permits for either site, the applicant shall have complied with all conditions of approval set with the existing approval (PLN 2005-050) and all of the conditions set forth with this application. 30. Proof of Ownership: Prior to issuance of any grading, drainage, or building permits for the site, the applicant shall provide a current Preliminary Title Report, grant deed, or other satisfactory proof of ownership. 31. Street Improvements: Prior to issuance of any grading or building permits for the site, the applicant shall execute a street improvement agreement, cause plans for public street improvements to be prepared by a registered civil engineer, pay various fees and deposits, post security and provide insurance necessary to obtain an encroachment permit for construction of the standard public street improvements, as required by the City Engineer. The plans shall include the following: a. Removal of 2.5" of existing asphalt concrete via grinding over entire frontage to centerline, or as required by the City Engineer. b. Installation of asphalt concrete overlay per street pavement restoration plan for utility installation and/or abandonment, as required by the City Engineer. c. Installation of traffic control, stripes and signs. d. Construction of conforms to existing public and private improvements, as necessary. 32. Occupancy: Prior to allowing occupancy for any and/or all buildings, the applicant shall have the required pavement restoration installed and accepted by the City, and the design engineer shall submit as-built drawings to the City. 33. Water Meter(s) and Sewer Cleanout(s): Existing and proposed water meter(s) and sewer c1eanout(s) shall be relocated or installed on private property behind the public right-of-way line. 34. Utilities: All new on-site utilities shall be installed underground per Section 21.18.140 of the Campbell Municipal Code for any new or remodeled buildings or additions. Applicant shall comply with all plan submittals, permitting, and fee requirements of the serving utility companies. 35. Utility Coordination Plan: Prior to issuance of building permits for the site, the applicant shall submit a utility coordination plan and schedule for approval by the City Engineer for the installation and/or abandonment of all utilities. The plan shall clearly show the location and size of all existing utilities and the associated main lines; indicate which utilities and services are to remain; which utilities and services Planning Commission Resolution No. 3720 PLN2006-03 & PLN2006-04 -- 1690 & 1692 Westmont Avenue Site and Architectural Review Permits - Two New Two-Story Single-Family Residences Page 9 are to be abandoned, and where new utilities and services will be installed. Joint trenches for new utilities shall be used whenever possible. 36. Pavement Restoration: Based on the utility coordination plan, the applicant shall prepare a pavement restoration plan for approval by the City Engineer prior to any utility installation or abandonment. Streets that have been reconstructed or overlaid within the previous five years will require boring and jacking for all new utility installations. Westmont Avenue was overlaid in 2003. The pavement restoration plan shall indicate how the street pavement shall be restored following the installation or abandonment of all utilities necessary for the project. COUNTY FIRE DEPARTMENT 37. Formal Plan Review: Review of this Developmental proposal is limited to acceptability of site access and water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall make application to, and received from, the Building Department all applicable construction permits. 38. Required Fire Flow: The fire flow for this project is 1750 gpm at 20 psi residual pressure. The required fire flow is available from area water mains and fire hydrant(s) which are spaced at the required spacing. 39. Rear Parcel: Fire Apparatus (Enqine) Access Drivewav Required: Provide an access driveway with a paved all weather surface, a minimum unobstructed width of 12 feet, vertical clearance of 13 feet 6 inches, minimum circulating turning radius of 35 feet outside and 23 feet inside, and a maximum slope of 15%. Installations shall conform to Fire Department Standard Details and Specifications sheet D-1. 40. Rear Parcel: Timinq of Required Drivewav Installations: Required driveway installations shall be constructed and accepted by the fire Department, prior to the start of combustible construction. Planning Commission Resolution No. 3720 PLN2006-03 & PLN2006-04 -- 1690 & 1692 Westmont Avenue Site and Architectural Review Permits - Two New Two-Story Single-Family Residences Page 10 PASSED AND ADOPTED this 23rd day of May, 2006, by the following roll call vote: AYES: NOES: ABSENT: ABSTAIN: Commissioners: Commissioners: Commissioners: Commissioners: Alderete, Ebner, Francois, Rocha and Roseberry None Doorley and Gibbons None APPROVED:~~q r~ ~ /? BobAde7ete, Chair ATTEST: j ~ Sharon Fierro, Secretary --'1