PC Res 1690RESOLUTION N0. 1690 PLANNING COMMISSION CITY OF CAMPBELL, CALIFORNIA After notification and public hearing as specified by law on the application of Mr. Barry Swenson for a use permit and approval of plans to construct a racquet club on property known as 70 S. San Tomas Aquino Road in a C-2-S (General Commercial) Zoning District, as per application filed in the office of the Planning Department on April 5, 1978, and after presentation by the Planning Director, proponents, and opponents, the hearing was closed (UP 78-6). After due consideration of all evidence presented, the Commission did find as follows: That the establishment, maintenance, and operation of the proposed use will not be detrimental to the health, safety, peace, morals, comfort, or general welfare of persons residing or working in the neighborhood of such use, or be detrimental or injurious to the property and improve- ments in the neighborhood or the general welfare of the City. Based on the above findings, the Planning Commission does hereby grant the requested use permit subject to the following conditions: 1. Revised elevations to be approved by the Planning Director upon recommendation of the Architectural Advisor. 2. Property to be fenced and landscaped as indicated and/or added in red on plans. 3. Landscaping plan indicating type and size of plant material, and location of hose bibs or sprinkler system to be submitted for approval of the Planning Director prior to application for building permit. 4. Fencing plan indicating location and design details of fencing to be submitted for approval of Planning Director prior to application for building permit. 5. Landscaping and fencing shall be maintained in accordance with the approved plan. 6. Applicant to either (1) post a faithful performance bond in the amount of $5,000 to insure landscaping, fencing, striping of parking areas within three months of completion of con- struction, or (2) file written agreement to complete land- scaping, fencing and striping of parking areas prior to final Building Department clearance. 7. All mechanical equipment located on roofs to be screened as approved by the Planning Director. The applicant is notified as part of this application that he/she is required to meet the following conditions in accordance with Ordinances of the City of Campbell and Laws of the State of California. A. All parking and driveway areas to be developed in compliance with Section 21.50 of the Campbell Municipal Code. All parking spaces to be provided with appropriate concrete curbs or bumper guards. B. Underground utilities to be provided as required by Section 20.16.070 of the Campbell Municipal Code. C. Plans submitted to the Building Department for plan check shall indicate clearly the location of all connections for underground utilities including water, sewer, electric, telephone and television cables, etc. D. Sign application to be submitted in accordance with provisions of the sign ordinance for all signs. No sign to be installed until application is approved and permit issued by the Building Department. (Section 21.68.070 of the Campbell Municipal Code.) E. Ordinance No. 782 of the Campbell Municipal Code stipulates that any contract for the collection and disposal of refuse, garbage, wet garbage and rubbish produced within the limits of the City of Campbell shall be made with Green Valley Disposal Company. This requirement applies to all single-family dwellings, multiple apartment units, to all commercial, business, industrial, manufacturing, and construction establishments. F. Trash container(s) of a size and quantity necessary to serve the development shall be located in area(s) approved by the Fire Department. Unless otherwise noted, enclosure(s) shall consist of a concrete floor surrounded by a solid wall or fence and have self-closing doors of a size specified by the Fire Department. All enclosures to be constructed at grade level. G. Applicant shall comply with all appropriate State and City require- ments for the handicapped. BUILDING DEPARTMENT H. South exterior wall covering not shown: Shall be min. 1 hr. Table 5-A. 1. Roof covering not shown shall be fire retardant Section 1603(a) and Section 3203(e). J. Occupancy classification is B-3. FIRE DEPARTMENT K. Locate trash enclosure on plans. L. Type occupancy is B-3, not F-2 as indicated on plans. M. Provide 2A-IOBC fire extinguishers. FIRE DEPARTMENT - Continued N. Obtain a permit to operate a place of assembly. 0. Provide emergency lighting system. P. Relocate existing hydrant to behind curb tine. PUBLIC WORKS DEPARTMENT Q. Dedicate right of way to a 45-foot half-street on San Tomas Aquino Road. R. Pay storm drainage area fee at 5765 per net acre. S. Enter into an agreement and post a bond to install street improvements across the frontage. T. Pay the plan examination and construction inspection fee. U. Provide a grading and drainage plan for the approval of the City Engineer. V. Relocate the existing power pole to behind the future curb. The applicant is notified that he shall comply with all applicable Codes or Ordinances of the City of Campbell which pertain to this develop- ment and are not herein specified. PASSED AND ADOPTED this 2nd day of May 1978 by the following roll call vote: AYES: Commissioners: Hebard, Campos, Dickson, Samuelson, Vierhus, Pack NOES: Commissioners: None ABSENT: Commissioners: None APPROVED: _ Margaret M. Pack Chairman ATTEST: Arthur A. Kee Secretary